Claim Missing Document
Check
Articles

Found 2 Documents
Search

BUSINESS STRATEGY ASSISTANCE AND TRAINING FOR MICRO, SMALL, AND MEDIUM ENTERPRISES Saut Maruli Tua Pandiangan; Siti Annisa Wahdiniawati; Ratih Pratiwi; Balla Wahyu Budiarto; Ilham Arief
JURNAL PENGABDIAN MANDIRI Vol. 2 No. 10: Oktober 2023
Publisher : Bajang Institute

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The purpose of this community service activity is to socialize business strategy assistance and training for micro, small, and medium enterprises. Based on the problems found and formulated, the problem-solving framework carried out through this community service activity is to socialize digital marketing business strategies in order to help increase sales to micro, small, and medium enterprises. The implementation of this community service activity is carried out using lecture, tutorial, and discussion methods. This socialization activity is very beneficial for micro, small, and medium enterprises who have businesses. Through this outreach activity, it is hoped that it can increase awareness of micro, small, and medium enterprises actors in East Medan District, Medan City, North Sumatra Province to start practicing using Facebook or Instagram for product promotion.
Analysis of the Cooling Load of the CC 206 Locomotive Driver's Cab for Determining the Air Conditioning System Capacity Balla Wahyu Budiarto; Dadang Sanjaya Atmaja; Dimas Adi Perwira
Jurnal Teknik Industri Terintegrasi (JUTIN) Vol. 9 No. 3 (2026): July
Publisher : LPPM Universitas Pahlawan Tuanku Tambusai

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31004/jutin.v9i3.61398

Abstract

The locomotive driver's cabin receives high thermal loads due to solar radiation through the large glass field and heat from the diesel engine room, thus requiring an air conditioning system with the right capacity for the comfort and safety of the operator. This study calculated the cooling load of the CC 206 Locomotive cab and compared it with the installed air conditioning capacity. Calculation using the CLTD/SCL approach heat load method (Hidayat & Restu, 2017; ASHRAE; SNI 03-6572-2001) with data on the structure and material of the casing from the technical data of the facility, at the design conditions of cabin temperature 25.5 °C, outside temperature 32.78 °C, and engine room temperature 40 °C.  The conductance value (U) of each element is calculated from the arrangement of the material layers. The results showed a total cooling load of ± 2,585 W (≈ 2,222 kcal/h; ≈ 0.73 TR), dominated by solar radiation through glass and ventilation latent loads. The capacity of the TERMORAIL TRC-8000 installed air conditioner is 8,000 kcal/hour, approximately 3.6 times the calculated load of tune; The margin is functional for pull-downs and extreme conditions. It was concluded that the installed air conditioning unit is very adequate in a tune-like manner, with the potential for optimization in glass shading and compressor capacity regulation.