Claim Missing Document
Check
Articles

Found 3 Documents
Search

Perbandingan Glukosa Metode Carik Celup Vitamin C 500 Mg pada Penderita Diabetes Melitus Tipe 2 Adriansyah; Didi Irwadi; Nurul Anggrieni
Jurnal Sains & Kesehatan Vol 2 No 2 (2023): Jurnal Sains dan Kesehatan
Publisher : Politeknik Baubau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.57151/jsika.v2i2.262

Abstract

Vitamin C is a water-soluble vitamin and is naturally present in food. Humans cannot synthesize vitamin C, so it must be obtained from outside and food as the main source. However, taking vitamin C before a urine glucose test can cause a false positive result for some people. The purpose of this study was to analyze the comparison of the results of urine glucose levels using the strip dip method before and after consuming 500 mg vitamin C in people with type 2 diabetes mellitus. This type of research is pre-experimental with a One-group pre-post test design that assesses the causal relationship with the intervention, namely the consumption of Vitamin C in urine samples that have previously been examined for urine glucose. The population in this study were type 2 diabetes mellitus patients who were treated at the Harapan Baru Health Center and the sampling technique used purposive sampling with a total sample of 33 samples. This research was conducted at the Clinical Chemistry Laboratory of the East Kalimantan Ministry of Health Polytechnic. The results of the examination of 33 respondents showed that the percentage of results had increased by 84.5%. The normality test using the Shapiro-Wilk statistical test showed that it was significant before and after consuming vitamin C of 0.000. This shows that these values are not normally distributed. The Wilcoxon statistical test showed a significant value of 0.000 with a significance level of 0.05, i.e. 0.000 <0.05, so it can be concluded that there was an increase in glucose results for urine chemistry examination by dipping method after consuming 500 mg of vitamin C in patients with type 2 diabetes mellitus.
Analisis Kadar Glukosa Darah, Alanine Aminotransferase, dan Aspartate Aminotransferase Pada Pasien Tuberkulosis Fase Pengobatan di Puskesmas Baqa Samarinda Alifa Fitri Nazwha; Tiara Dini Harlita; I Gede Andika Sukarya; Didi Irwadi
Jaringan Laboratorium Medis Vol 8 No 2 (2026): November 2026
Publisher : Poltekkes Kemenkes Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31983/jlm.v8i2.15085

Abstract

Tuberculosis (TB) is an infectious disease requiring long-term treatment using anti-tuberculosis drugs (OAT), which may cause side effects, particularly on blood glucose levels and liver function. This study aimed to analyze blood glucose, ALT, and AST levels and to determine their differences based on treatment duration in category 1 tuberculosis patients during the treatment phase at Baqa Primary Health Center, Samarinda. This study employed an analytical observational design with a cross-sectional approach, involving 30 category 1 tuberculosis patients undergoing 1–2 months of OAT therapy with a rifampicin, isoniazid, pyrazinamide, and ethambutol (RHZE) regimen. Blood glucose was measured using a strip-based glucometer, while ALT and AST were examined using the kinetic method. The Shapiro-Wilk normality test showed that the data were not normally distributed; therefore, the Mann-Whitney test was used to analyze differences. The results showed significant differences in blood glucose (p = 0.032) and ALT (p = 0.003) levels based on treatment duration, whereas no significant difference was found in AST levels (p = 0.099). It is concluded that treatment duration significantly affects blood glucose and ALT levels, but not AST levels. These findings indicate the importance of regularly monitoring blood glucose and liver function, particularly ALT, during OAT therapy to enable early detection of metabolic and hepatotoxic side effects. TB patients are advised to undergo periodic laboratory examinations throughout the treatment period to support therapeutic success.
Perbandingan Hasil Activated Partial Thromboplastin Time Menggunakan Metode Manual dan Semi Otomatis (Coatron M1) Rani Angelika Putri Rahmawati; Supri Hartini; I Gede Andika Sukarya; Didi irwadi
Sehat Rakyat: Jurnal Kesehatan Masyarakat Vol. 5 No. 4 (2026): November 2026
Publisher : Yayasan Pendidikan Penelitian Pengabdian Algero

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54259/sehatrakyat.v5i4.8795

Abstract

Activated Partial Thromboplastin Time (APTT) is a hemostasis laboratory test used to evaluate the intrinsic and common coagulation pathways. APTT testing can be performed using either a manual method or a semi-automated instrument, such as the Coatron M1. Differences in the working principles of these methods may lead to variations in test results. This study aimed to analyze APTT test results obtained using the manual method and the semi-automated Coatron M1 method. A comparative analytical study with a cross-sectional design was conducted. Citrated plasma samples were collected from 39 third-year students of the Diploma III Medical Laboratory Technology Study Program, Poltekkes Kemenkes Kalimantan Timur. Venous blood was collected into tubes containing 3.2% sodium citrate with a blood-to-anticoagulant ratio of 9:1. APTT was measured using both methods, and the data were analyzed descriptively. Data normality was assessed using the Shapiro–Wilk test, while differences between the two methods were analyzed using the Wilcoxon Signed-Rank Test. The mean APTT value obtained using the manual method was 30 ± 2 seconds, whereas the semi-automated method (Coatron M1) produced a mean value of 29 ± 3 seconds. Statistical analysis revealed a significant difference between the two methods (p = 0.010), although all results remained within the normal reference range. Therefore, both methods can be used for APTT testing in clinical laboratories.