Widhiatmaka, Widhiatmaka
Prosiding Seminar Nasional Teknik Kimia "Kejuangan"

Published : 3 Documents Claim Missing Document
Claim Missing Document
Check
Articles

Found 3 Documents
Search

PENGUJIAN HARMONISA PADA LAMPU HEMAT ENERGI (LHE) MENURUT STANDAR IEC 61000-3-2 KELAS C, IEEE 512-1992 DAN POWER FACTOR PLN (STUDI KASUS UNTUK LHE 5 WATT) Widhiatmaka, Widhiatmaka; Aman, Mohamad
Ketenagalistrikan dan Energi Terbarukan Vol 11, No 2 (2012): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Telah diuji tingkat harmonisa yang ditimbulkan oleh 6 sampel lampu hemat energi (LHE) 5 watt yang beredar di pasaran. Data individual harmonic distortion (IHD) diukur sampai orde ke-39 untuk setiap LHE, sesuai standar International Electrotechnical Commission (IEC) 61000. Hasil pengujian menunjukkan bahwa ITHD berkisar 69,3-81,72%, power factor (PF) 0,54-0,62, dan IHD tertinggi pada orde ke-3 dan diikuti orde ke-5. Menurut standar Institute of Electrical and Electronics Engineers (IEEE) 519-1992 ITHD < 20%, standar Perusahaan Listrik Negara (PLN) PF ≥ 0,85 dan standard IEC 61000, dapat disimpulkan bahwa 6 sampel LHE tersebut tidak ada yang memenuhi standar performance yang disyaratkan. The level of harmonics generated by the six samples of common market energy-saving lamps (ESL) of 5 watts has been measured up to the 39th order for each ESL, according to IEC 61000. From thetest results of the six samples show ITHD ranged from 69.3 to 81.72%, and power factor (PF) 0.54 - 0.62, with the highest harmonics on the order of the 3rd and 5th. According to the IEEE Standard 519-1992 ITHD has to be less than 20%, PLN standard i.e. PF has to be greater than or equal to 0.85, and the IEC61000. It can be concluded that  the six samples of ESL have not met the required performance standards.
PENGGUNAAN BIOETANOL (E100) PADA GENSET KAPASITAS 5 KVA ; BIOETHANOL (E100) UTILISATION IN 5 KVA GENERATOR Firmansyah, Arfie Ikhsan; Gunawan, Yohanes; Adilla, Ikrar; Widhiatmaka, Widhiatmaka
Ketenagalistrikan dan Energi Terbarukan Vol 16, No 1 (2017): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sebuah eksperimen dilakukan untuk mempelajari unjuk kerja mesin genset mengunakan bahan bakar bioetanol 100% (E100). Pada eksperimen ini digunakan mesin genset 5 kVA yang dimodifikasi pada saluran masuk bahan bakar dan saluran keluar/gas buang dengan alat penukar kalor, sehingga didapatkan temperatur evaporasi bioetanol yang optimal untuk proses pembakaran. Generator/genset dibebani dengan variasi beban dari 1 kW, 2 kW, 3 kW. 4 kW, dan 5 kW, dengan tujuan untuk mengetahui konsumsi etanol, temperatur penukar kalor, dan gas buang per beban yang divariasikan. Kinerja genset dengan penambahan penukar kalor menunjukkan, saat temperatur gas buang mencapai 460oC, terjadi kenaikan temperatur etanol sebelum masuk ke ruang bakar, yaitu sebesar 40oC dibandingkan temperatur awal. Hasil uji pembebanan menunjukkan bahwa pada beban 5000 watt didapatkan efisiensi termal yang paling optimum, yaitu mencapai 20,6 %, dengan konsumsi bahan bakar etanol sebanyak 2721,2 gr/ kWh bioetanol. Penggunaan bioetanol mampu menekan emisi CO hingga mencapai 0,011%. Bila dibandingkan dengan penggunaan bahan bakar bensin, penggunaan bioetanol pada genset dengan modifikasi pada temperatur saluran suplai udara dan bahan bakar, memiliki efiensiensi termal lebih tinggi dibandingkan bensin.An experiment was conducted to study the performance of engine generator using 100% bioethanol fuel (E100). This experiment employed a 5 kVA generator engine that has been modified in its fuel inlet and outlet / exhaust with a heat exchanger, to obtain an optimal bioethanol evaporation temperature for the combustion process. The generator was loaded with several electrical load variations i.e. 1 kW, 2 kW, 3 kW. 4 kW and 5 kW, in order to to determine ethanol consumption, temperature of the heat exchanger and the flue gas emitted per variation of the loads applied. The addition of heat exchanger showed that when the exhaust gas temperature reaches 460oC, the temperature of ethanol increased for about 40°C from the initial before entering the combustion chamber. Loading test showed that the 5000 watt load obtained optimal thermal efficiency, it reached 20.6%, with ethanol consumption as much as 2721.2 g / kWh. Bioethanol utilisation also able to reduce CO emission up to 0.011%. Compared to the use of gasoline, using bioethanol in modified generator engine by adding heat exchanger, has a higher thermal eficiency number.
ANALISIS KINERJA PLTU INDRAMAYU SEPANJANG TAHUN 2015; PERFORMANCE ANALYSIS OF INDRAMAYU'S COAL-FIRED POWER PLANTS IN YEAR 2015 Widhiatmaka, Widhiatmaka; Gunawan, Yohanes; Simorangkir, Charles Lambok F.; Aman, Mohamad
Ketenagalistrikan dan Energi Terbarukan Vol 16, No 2 (2017): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Subsidi listrik yang semakin besar telah memberatkan pengeluaran Anggaran Pendapatan Belanja Negara (APBN) untuk biaya energi. Salah satu cara untuk mengurangi subsidi tersebut adalah dengan meningkatkan efisiensi pada pembangkit listrik. Pembangkit Listrik Tenaga Uap (PLTU) adalah pembangkit terbesar di Indonesia yang harus ditingkatkan efisiensinya dengan menurunkan heat rate. Tujuan dari penelitian adalah untuk menganalisis kinerja PLTU Indramayu (Jawa Barat) yang mempunyai kapasitas 3x330 MW sepanjang tahun 2015. Metodologi yang digunakan adalah metode heat loss atau metode tidak langsung dan diasumsikan bahwa nilai heat rate yang rendah akan menghasilkan efisiensi yang maksimum. Hasil menunjukkan bahwa dari ketiga unit yang ada, Unit 3 memiliki nilai heat rate terendah yaitu 2.765 kcal/kWh dengan kalori batubara 4.690 kcal/kg dan efisiensi termal tertinggi yaitu 31,1%. Dengan data tersebut dapat dikatakan bahwa PLTU Indramayu tidak efisien yang disebabkan oleh rugi-rugi boiler akibat hilangnya panas pada preheater air. Dua hal penting yang perlu diperhatikan untuk meningkatkan efisiensi PLTU Indramayu adalah kalori batubara dan kebocoran pada komponen-komponen boiler. Kata kunci: heat rate; efisiensi termal; PLTU;  The increasing of electricity subsidy – in terms of energy – has resulted a heavy burden on government spending. One of the key strategies to reduce those burden is generation efficiency. Coal-fired power plant has currently been the largest generating capacity in Indonesia. This paper examines the generation performance in Indramayu’s coal-fired power plant (West Java) in year 2015 which has a total capacity 3x330 MW. The methodology used is the heat loss or indirect method and we assume that the lowest heat rate parameter could produce a maximum efficiency. The results show that among 3 installed units, there was only one units (3rd unit) that the lowest heat rate (2,765 kcal/kWh), using coal callories (4,690 kcal/kg) and highest thermal efficiency about 31.1%. These implies that Indramayu’s power plants in inefficient due to the boiler losses: heat elimination at the water preheater. Two crucial components that are required to increase the Indramayu’s generation capacity, that are coal callories and leakage on boiler components. Keywords: heat rate; thermal efficiency; coal- fired power plan;