STUDI EKSPERIMENTAL PEMBAKARAN SERBUK BATUBARA PADA PEMBAKAR SIKLON; EXPERIMENTAL STUDY ON COAL POWDER COMBUSTION IN A CYCLONE BURNER Gunawan, Yohanes; Setiadanu, Guntur Tri; Nafis, Subhan
Ketenagalistrikan dan Energi Terbarukan Vol 14, No 2 (2015): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Studi ekperimen pembakaran serbuk batubara kalori rendah menggunakan Pembakar Siklon telah dilakukan untuk  mempelajari pengaruh variasi aliran massa udara dan bahan bakar terhadap karakteristik pembakaran yang terjadi, dimana titik-titik temperatur diukur pada sepanjang badan Pembakar Siklon yang dibagi menjadi 4 titik pengukuran. Peningkatan suplai udara mengakibatkan konsentrasi gas hasil pembakaran cenderung naik dan mengakibatkan nilai equivalent ratio (ER) melebihi 1, dimana dengan nilai ER lebih dari 1 pembakaran akan kaya udara (lean). Emisi CO2, CO, NO dan NOx yang mempunyai nilai terendah dihasilkan dari campuran udara dan bahan bakar dengan nilai ER 1,09 atau nilai air fuel ratio (AFR) 7,6. Temperatur tertinggi untuk semua variasi campuran udara dan bahan bakar terjadi pada area inlet udara dan bahan bakar (T1). Pembakaran stabil terjadi pada komposisi emisi gas (O2 dan CO) terendah, dan nilai temperatur yang hampir sama pada setiap titik pengukuran, yaitu pada variasi feeder batubara 0,78 kg/menit dan blower udara 4,323 m3/menit dengan nilai AFR = 6,6 dan ER = 0,95. Experimental studies burning low calorie coal powder in a cyclone burner have been conducted to study the effect of variations in the mass flow of air and fuel to the combustion characteristics that occurred, where the temperature points measured at the whole body of the cyclone burner is divided into four  measurement points. Increased air supply result in  concentrations of combustion gases tend to rise and result in ER exceeds 1, where if the value of ER more than 1 combustion air would be rich (lean). Emissions of CO2, CO, NO and NOx which have the lowest value resulted from the mixture of air and fuel by the ER value is 1.09 or the value of AFR 7.6. The highest temperature for all variations of a mixture of air and fuel occurs in the area of air and fuel inlet (T1). The most stable combustion occurs on lowest gas emission composition(O2 and CO) and the temperature at each measurement point are almost the same, it's reached on variation of coal feeder 0.78 kg/min and air blower 4.323 m3/min with AFR value = 6.6 and ER = 0.95.
ANALISIS PEMANFAATAN PANAS BUANG PLTG UNTUK MENINGKATKAN DAYA OUTPUT MENGGUNAKAN SISTEM PENDINGIN ABSORPSI STUDI KASUS: PLTG PESANGGARAN BALI Suntoro, Dedi; Firmansyah, Arfie Ikhsan; Setiadanu, Guntur Tri; Gunawan, Yohanes
Ketenagalistrikan dan Energi Terbarukan Vol 17, No 2 (2018): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

PLTG mengalami penurunan daya output jika beroperasi di daerah yang memiliki suhu dan kelembaban udara tinggi seperti di daerah tropis. Tulisan ini membahas analisis termodinamika dan analisis finansial pemanfaatan panas buang PLTG Pesanggaran Bali untuk meningkatkan daya output dengan cara mendinginkan udara masuk menggunakan sistem absorpsi. Metode analisis temodinamika dilakukan dengan menggunakan bantuan software EES, sedangkan analisis kelayakan finansial menggunakan perhitungan NPV, IRR dan payback period. PLTG Pesanggaran Bali terdiri dari PLTG 1 dan PLTG 2 dengan kapasitas daya 20 MW dan PLTG 3 dan PLTG 4 dengan kapasitas daya 40 MW. Semua PLTG Pesanggaran Bali tidak beroperasi kontinu dan hanya beroperasi pada saat beban puncak, oleh sebab itu dalam analisis kelayakan finansial diskenariokan beroperasi 4 jam/hari sampai dengan 22 jam/hari. Dari analisis termodinamika didapatkan bahwa daya output PLTG 1 dan PLTG 2 meningkat sebesar 3,36% sedangkan PLTG 3 dan PLTG 4 meningkat 4,76%. Analisis kelayakan investasi menunjukan bahwa pemanfaatan panas buang PLTG untuk meningkatkan daya output dengan menggunakan sistem absorpsi pada PLTG 1 dan PLTG 2 layak jika beroperasi dengan NPV 8,516 milyar rupiah, IRR 15,65% dan payback period 4,33 tahun, sedangkan pada PLTG 3 dan PLTG 4 layak jika beroperasi dengan NPV 19,004 milyar rupiah, IRR 17,4, dan payback period 3,99 tahun.
PENGGUNAAN BIOETANOL (E100) PADA GENSET KAPASITAS 5 KVA ; BIOETHANOL (E100) UTILISATION IN 5 KVA GENERATOR Firmansyah, Arfie Ikhsan; Gunawan, Yohanes; Adilla, Ikrar; Widhiatmaka, Widhiatmaka
Ketenagalistrikan dan Energi Terbarukan Vol 16, No 1 (2017): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sebuah eksperimen dilakukan untuk mempelajari unjuk kerja mesin genset mengunakan bahan bakar bioetanol 100% (E100). Pada eksperimen ini digunakan mesin genset 5 kVA yang dimodifikasi pada saluran masuk bahan bakar dan saluran keluar/gas buang dengan alat penukar kalor, sehingga didapatkan temperatur evaporasi bioetanol yang optimal untuk proses pembakaran. Generator/genset dibebani dengan variasi beban dari 1 kW, 2 kW, 3 kW. 4 kW, dan 5 kW, dengan tujuan untuk mengetahui konsumsi etanol, temperatur penukar kalor, dan gas buang per beban yang divariasikan. Kinerja genset dengan penambahan penukar kalor menunjukkan, saat temperatur gas buang mencapai 460oC, terjadi kenaikan temperatur etanol sebelum masuk ke ruang bakar, yaitu sebesar 40oC dibandingkan temperatur awal. Hasil uji pembebanan menunjukkan bahwa pada beban 5000 watt didapatkan efisiensi termal yang paling optimum, yaitu mencapai 20,6 %, dengan konsumsi bahan bakar etanol sebanyak 2721,2 gr/ kWh bioetanol. Penggunaan bioetanol mampu menekan emisi CO hingga mencapai 0,011%. Bila dibandingkan dengan penggunaan bahan bakar bensin, penggunaan bioetanol pada genset dengan modifikasi pada temperatur saluran suplai udara dan bahan bakar, memiliki efiensiensi termal lebih tinggi dibandingkan bensin.An experiment was conducted to study the performance of engine generator using 100% bioethanol fuel (E100). This experiment employed a 5 kVA generator engine that has been modified in its fuel inlet and outlet / exhaust with a heat exchanger, to obtain an optimal bioethanol evaporation temperature for the combustion process. The generator was loaded with several electrical load variations i.e. 1 kW, 2 kW, 3 kW. 4 kW and 5 kW, in order to to determine ethanol consumption, temperature of the heat exchanger and the flue gas emitted per variation of the loads applied. The addition of heat exchanger showed that when the exhaust gas temperature reaches 460oC, the temperature of ethanol increased for about 40°C from the initial before entering the combustion chamber. Loading test showed that the 5000 watt load obtained optimal thermal efficiency, it reached 20.6%, with ethanol consumption as much as 2721.2 g / kWh. Bioethanol utilisation also able to reduce CO emission up to 0.011%. Compared to the use of gasoline, using bioethanol in modified generator engine by adding heat exchanger, has a higher thermal eficiency number.
ANALISIS KEGAGALAN MECHANICAL SEAL PADA PENGUJIAN KEBOCORAN TURBIN ORC; THE ANALYSIS OF THE MECHANICAL SEAL FAILURE AT ORC TURBINE LEAKAGE TEST Setiadanu, Guntur Tri; Gunawan, Yohanes; Sukaryadi, Didi
Ketenagalistrikan dan Energi Terbarukan Vol 14, No 1 (2015): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Mechanical seal adalah peralatan yang berfungsi untuk mencegah kebocoran pada turbin organic rankine cycle (ORC) yang bekerja dengan menggesekan permukaan o-ring tungsten karbida (WC) dan grafit (C). Terjadi kegagalan pada pengujian kebocoran mechanical seal untuk turbin ORC akibat patahnya ring tungsten karbida. Studi ini melakukan analisis kerusakan ring tungsten kabida yang patah. Hasil yang didapatkan adalah terjadi fenomena panas berlebih ketika gesekan operasi ring tungsten karbida yang tidak mampu didinginkan oleh sistem pendingin menggunakan oli SAE 40 pada saat pengujian. Dari pengujian pada ring tungsten karbida didapatkan bahwa terjadi retak akibat panas yang tinggi pada permukaan gesek ring tungsten pada lokasi dibawah garis tengah permukaan gesek.Retak tersebut diinisiasi oleh kombinasi pelemahan ikatan pada batas butir tungsten karbida, bending momen akibat laju ekspansi termal yang berbeda karena pendinginan yang tidak merata dan getaran pada permukaan gesek. Dengan naiknya temperatur, getaran dan tekanan kerja retak tersebut terpropagasi sehingga ring tungsten menjadi patah. Mechanical seal is an equipment that prevents leakage in an ORC (organic rankine cycle) turbine by utilize surface friction between tungsten carbide (WC) and graphite (C) o-rings. Failure has occurred in the testing of mechanical leakage for ORC turbine caused by tungsten carbide ring fracture. This study conducts a damage analysis of the fractured tungsten carbide ring. The result shows that there is an overheat phenomenon caused by the fraction of o-ring tungsten carbides which unable to cool off using SAE 40 cooling system. From the ring tungsten carbides test, it is known that a heat cracks has occurred below the center line of the tungsten ring friction surface. The crack is initiated by the combination of the bond weakening at the grain boundaries of tungsten carbides, the bending moments from the different rate of thermal expansion cause by unproper cooling system and vibration at friction surface. The increase of the temperature, vibration and work pressure have caused the crackto be propagated so the tungsten ring became broken.
SIMULASI NUMERIK FENOMENA TURBULENSI DI DALAM PEMBAKAR SIKLON ; NUMERICAL SIMULATION OF TURBULENCE PHENOMENA WITHIN CYCLONE BURNER gunawan, yohanes; Ridho, Mohammad; Setiadanu, Guntur Tri
Ketenagalistrikan dan Energi Terbarukan Vol 15, No 2 (2016): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pembakar Siklon adalah tungku berbentuk silinder, dimana serbuk bahan bakar ditiupkan bersama udara pembakar secara tangensial, sehingga serbuk bahan bakar akan berputar dan terbakar dalam ruang siklon tersebut secara intensif. Tingkat homogenitas bahan bakar dengan udara (reaktan), waktu tinggal reaktan, tingkat turbulensi serta energi kinetik turbulensi (TKE) sangat mempengaruhi efisiensi pembakaran. Untuk mengetahui gambaran lebih detail terhadap fenomena turbulensi dan nilai TKE pada pembakar siklon maka dilakukan kajian secara numerik dengan simulasi Computational Fluid Dynamics (CFD). V ariasi kecepatan udara awal yang d igunakan dalam si mulasi ad alah 9,35; 8,45;7,52 m/s. Domain utama untuk simulasi adalah tungku pembakar siklon yang mempunyai panjang 148 cm dengan diameter outlet 42 cm dan diameter pada pangkal interiornya 22 cm. Kecepatan udara awal untuk memvalidasi hasil simulasi diukur menggunakan venturi meter dan kecepatan aliran udara didalam tungku pembakar siklon diukur menggunakan hot wire anemometer. Hasil simulasi tervalidasi menunjukkan bahwa fenomena turbulensi pada setiap plane bervariasi sehingga TKE memiliki nilai yang semakin kecil seiring dengan jarak yang ditempuh setelah memasuki ruang bakar. Sementara itu, kecepatan baru mulai menunjukkan homogenitasnya dan pengurangan kecepatan ketika mendekati plane 3 yang berjarak 122.42 cm dari pusat inlet. Nilai TKE di sepanjang pembakar siklon dapat dijadikan acuan untuk memprediksi pada titik mana suhu tertinggi dan terendah akan terjadi jika eksperimen pembakaran dilakukan. Selain itu, adanya ruang deadzone pada ruang pembakar siklon juga menyebabkan sebagian aliran fluida mengalir dan terperangkap pada wila yah tersebut. A cyclone burner is a cylindrical furnace, where the fuel powder is blown along the air-fuel burners tangentially so that fuel powder is rotated and burned in the cyclone chamber intensively. The level of homogeneity of the fuel with air (reactants), the residence time of the reactants, the degree of turbulence and turbulence kinetic energy (TKE) greatly affect the efficiency of combustion. To find out a more detailed picture of the phenomenon of turbulence and the value of TKE on the cyclone burner, the numerical simulation using Computational Fluid Dynamics (CFD) is examined. Variations in the initial air velocity used in the simulation are 9.35; 8.45; 7.52 m/s. The main domain for simulation is a cyclone burner furnace which have a length of 148 cm with an outlet diameter of 42 cm and an interi-or base diameter of 22 cm. Initial air velocity to validate the simulation results were measured using a venturi meter and air flow velocity inside the cyclone furnaces is measured using a hot wire anemometer. The simulation results show that the phenomenon of turbulence validated on each plane is varied, hence TKE has a value that is smaller along the distance, only after entering the combustion chamber. While the new speed is starting to show homogeneity and reduced speeds when approaching plane 3 within 122.42 cm from the center of the inlet. TKE value along the cyclone burners can be used as a reference for predicting where the highest and lowest temperatures will occur if thecombustion experiments are performed. In addition, the dead zone space of the cyclone burner chamber also causes some fluid stream flows, which then get caught in the region.
PENGARUH PENURUNAN KARAKTERISTIK SUMBER PANAS TERHADAP KINERJA HEAT EXCHANGER DI PLTP BINER DIENG ; THE EFFECT OF DECREASED HEAT SOURCE PROPERTIES ON HEAT EXCHANGER PERFORMANCE AT DIENG BINARY POWER PLANT Setiadanu, Guntur Tri; Gunawan, Yohanes; Sukaryadi, Didi
Ketenagalistrikan dan Energi Terbarukan Vol 15, No 2 (2016): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Fenomena penurunan nilai karakteristik temperatur dan tekanan telah terjadi pada sumber panas PLTP biner Dieng. Pada studi ini dilakukan perhitungan model matematis dan termodinamika menggunakan software Engineering Equation Solver (EES) dan NIST Refprop untuk memprediksi pengaruh penurunan karakteristik sumber panas terhadap kemampuan heat exchanger dan efisiensi total dari sistem biner ORC. Hasil dari perhitungan akan dibandingkan dengan data aktual yang diperoleh dari pengujian sistem PLTP biner. Simulasi menunjukkan bahwa penurunan sumber panas mengakibatkan turunnya semua nilai parameter tekanan, temperatur dan laju alir dari n-pentane yang pada akhirnya akan menurunkan nilai kerja mekanik turbin dan listrik yang dihasilkan dibandingkan dengan desain awal. Laju n-pentane optimal dari simulasi desain adalah 0,9 kg/s, dengan tekanan kerja 6 bar, dan kalor perpindahan panas yang diterima n-pentane dari sumber adalah 419,51 kW dengan potensi untuk menggerakkan turbin sebesar 28,15 kW. Hasil pengujian aktual pada PLTP biner Dieng didapatkan bahwa nilai optimal laju n-pentane adalah 0,5 kg/s, kalor perpindahan panas sebesar 255,39 kW, tekanan kerja 6 bar dan potensi untuk menggerakkan turbin sebesar 12,31 kW. Perbedaan nilai kerja turbin antara hasil simulasi dengan percobaan aktual disebabkan oleh nilai input brine optimal saat percobaan di lapangan tidak bisa mencapai nilai optimal saat disimulasikan, akibat adanya pressure drop dan heat loss pada pipa heat exchanger sehingga laju n-pentane yang teruapkan juga turun. A decreased in temperature and pressure properties of heat source waste brine has occurred at Dieng binary geothermal power plant. This study performed mathematical models and thermodynamic calculations using EES and NIST Refprop software to predict the effect of decreased heat source brine to the heat exchanger capability and the total efficiency of the ORC binary system. Simulation’s results will be compared with actual data obtained from experiment at Dieng binary geothermal power plant. The results showed that a decrease in the heat source resulting values declining in all parameters, i.e. pressure, temperature and flow rate of n-pentane, moreover it will reduced the turbine mechanical work and electricity produced while compared with the initial design. Optimal mass rate of n-pentane from the simulation is 0,9 kg / s, with a working pressure of 6 bar, and heat transfer value received from source brine to n-pentane is 419,51 kW, predicted work turbine is 28,15 kW. Actual experiment on Dieng binary geothermal power plant show the optimal value of n-pentane mass rate is 0,5 kg / s, heat the heat transfer amounted to 255,39 kW, 6 bar working pressure and turbine work that can be produced is 12.31 kW. Those differences were due to the pressure drop and heat loss in the heat exchanger.
ANALISIS KINERJA PLTU INDRAMAYU SEPANJANG TAHUN 2015; PERFORMANCE ANALYSIS OF INDRAMAYU'S COAL-FIRED POWER PLANTS IN YEAR 2015 Widhiatmaka, Widhiatmaka; Gunawan, Yohanes; Simorangkir, Charles Lambok F.; Aman, Mohamad
Ketenagalistrikan dan Energi Terbarukan Vol 16, No 2 (2017): KETENAGALISTRIKAN DAN ENERGI TERBARUKAN
Publisher : P3TKEBTKE

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Subsidi listrik yang semakin besar telah memberatkan pengeluaran Anggaran Pendapatan Belanja Negara (APBN) untuk biaya energi. Salah satu cara untuk mengurangi subsidi tersebut adalah dengan meningkatkan efisiensi pada pembangkit listrik. Pembangkit Listrik Tenaga Uap (PLTU) adalah pembangkit terbesar di Indonesia yang harus ditingkatkan efisiensinya dengan menurunkan heat rate. Tujuan dari penelitian adalah untuk menganalisis kinerja PLTU Indramayu (Jawa Barat) yang mempunyai kapasitas 3x330 MW sepanjang tahun 2015. Metodologi yang digunakan adalah metode heat loss atau metode tidak langsung dan diasumsikan bahwa nilai heat rate yang rendah akan menghasilkan efisiensi yang maksimum. Hasil menunjukkan bahwa dari ketiga unit yang ada, Unit 3 memiliki nilai heat rate terendah yaitu 2.765 kcal/kWh dengan kalori batubara 4.690 kcal/kg dan efisiensi termal tertinggi yaitu 31,1%. Dengan data tersebut dapat dikatakan bahwa PLTU Indramayu tidak efisien yang disebabkan oleh rugi-rugi boiler akibat hilangnya panas pada preheater air. Dua hal penting yang perlu diperhatikan untuk meningkatkan efisiensi PLTU Indramayu adalah kalori batubara dan kebocoran pada komponen-komponen boiler. Kata kunci: heat rate; efisiensi termal; PLTU;  The increasing of electricity subsidy – in terms of energy – has resulted a heavy burden on government spending. One of the key strategies to reduce those burden is generation efficiency. Coal-fired power plant has currently been the largest generating capacity in Indonesia. This paper examines the generation performance in Indramayu’s coal-fired power plant (West Java) in year 2015 which has a total capacity 3x330 MW. The methodology used is the heat loss or indirect method and we assume that the lowest heat rate parameter could produce a maximum efficiency. The results show that among 3 installed units, there was only one units (3rd unit) that the lowest heat rate (2,765 kcal/kWh), using coal callories (4,690 kcal/kg) and highest thermal efficiency about 31.1%. These implies that Indramayu’s power plants in inefficient due to the boiler losses: heat elimination at the water preheater. Two crucial components that are required to increase the Indramayu’s generation capacity, that are coal callories and leakage on boiler components. Keywords: heat rate; thermal efficiency; coal- fired power plan;
KEPEMIMPINAN MGR. I. SUHARYO DI KEUSKUPAN AGUNG SEMARANG PERIODE 1997-2009 DALAM TERANG KEPEMIMPINAN ANTHONY DSOUZA Gunawan, Yohanes
Jurnal Teologi (Journal of Theology) Vol 2, No 2 (2013)
Publisher : P3TK, Sanata Dharma University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24071/jt.v2i2.443

Abstract

By the end of twentieth century, leadership crisis occured in various sectors of life and institutions. In this situation, Christian Leadership associated identically with the leadership model of Jesus Christ is offered to the society. Anthony DSouza formulated the Leadership of Jesus with 3-S formula, namely: Servant, Steward, and Shepherd. The true leadership basically conceived three traits, namely: ennoble, ennable, and empower. This research aims to explore the leadership of Mgr. Ignatius Suharyo in the Archdiocese of Semarang during 1997-2009. He led people of God in the Archdiocese of Semarang during the transition period from the XX century to XXI century. In the transition, two main challenges emerged in the life of society and church, namely: massive stream of globalization and danger of nations disintegration. Mgr. Suharyo wrote 27 letters of shepherd to provide guidance for the people of God. Through these letters, Mgr. Suharyo proposed the idea of Gereja Sebagai Peristiwa (Church as a Happening). This idea reflected his vision of leadership and his ecclesiological perspective to determine the Churchs face. Referring to Anthony DSouzas view of leadership, this research found that Mgr. Suharyo experienced himselfas a leader serving humbly, a steward bearing historical responsibility, and a shepherd having discipline yet gentle nature (fortiter sed suaviter). He also committed his leadership through some ways, namely: giving meaning and inspiring through key words, shifting mindset intelligently, and developing communal sharing (duduk bersama) culture. This leadership model was reflected in his motto: Serviens Domino Cum Omni Humilitate (Acts 20:19). This motto was then realized in his work as the Archbishop of Semarang through words and actions.
Experimental Investigation of Using Thermoelectric Coolers under Different Cooling Methods as An Alternative Air Conditioning System for Car Cabin Sukarno, Ragil; Premono, Agung; Gunawan, Yohanes; Wiyono, Apri; Lubi, Ahmad
Automotive Experiences Vol 7 No 2 (2024)
Publisher : Automotive Laboratory of Universitas Muhammadiyah Magelang in collaboration with Association of Indonesian Vocational Educators (AIVE)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31603/ae.11485

Abstract

The cabin car temperature will increase when parked in direct sunlight, so the energy required to cool cabin space by the air conditioner will be higher. This study aims to investigate using a thermoelectric cooling system as an alternative to a chiller system to supply cold air to the car cabin under different cooling methods for parked cars. Experimental testing of thermoelectric cooling systems was conducted to produce cold air that can be applied to car cabins as an alternative to conventional air conditioners. The thermoelectric cooling system was varied with single and double TEC modules. The double TEC modules are arranged in a series of electrical and parallel thermal arrangements. A cooling water block using a mixture of water and ethylene glycol with variations of 0.4 lpm, 0.5 lpm, and 0.6 lpm was added to the hot side of the thermoelectric module. The result shows that the thermoelectric cooling system can work properly during the 2-hour test, which constantly supplies air to the cabin space between 20-25 °C, depending on the configuration of the cooling system. The highest COP of 0.84 was obtained when using the double TEC with heatsink and added 0.5 lpm water cooling system, while the lowest COP of 0.53 was obtained when using the single TEC module without a cooling water block.
Experimental investigation of a thermoelectric generator assisted with heat pipe sinks for pickup car exhaust waste heat recovery Sukarno, Ragil; Indasyach Moreno, Zavi; Rio Budi Syaka, Darwin; Gunawan, Yohanes; Gama Yoga, Nugroho; Fariz Adzani, Rivaldo; Putra Mustafit, Alvian; Kurniawati, Desy
Communications in Science and Technology Vol 10 No 1 (2025)
Publisher : Komunitas Ilmuwan dan Profesional Muslim Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21924/cst.10.1.2025.1661

Abstract

In internal combustion engine vehicles (ICEV), about 40% of the heat is discharged into the environment as waste heat. This study proposed to develop an energy recovery device to utilize exhaust heat as electrical energy using a thermoelectric generator (TEG) assisted with a heat pipe sink. Six TEG units were installed on the stainless-steel heat block in an exhaust pipe where each TEG unit varied with one-stage TEG and two-stage TEG modules. The results showed that the maximum power generated and TEG efficiency of 1.4 W and 1.14% were obtained under 180oC of exhaust pipe temperature, with a two-stage TEG with a heat pipe sink under forced convection. The use of a heat pipe sink and under-forced convection improves the TEG system's performance by increasing the temperature difference between both sides of the TEG module, which impacts the electric power generated. This research provides some practical guidance for increasing the power and efficiency of TEGs by improving heat transfer performance through heat pipes.