Claim Missing Document
Check
Articles

Found 3 Documents
Search

Development of a Web-Based Hazard Reporting Prototype as a Learning Aid for Occupational Safety Mayati Isabella; Rizky Amelia; Arini Anestesia Purba; Tri Hardiyanti Asmaningrum; Muhammad Azka Yunastio; Archangela Adelina; Athaya Nur Khayyirah; Elvira Rahmadhani Setyaningrum
G-Tech: Jurnal Teknologi Terapan Vol 10 No 4 (2026): G-Tech, Vol. 10 No. 4 October 2026
Publisher : Universitas Islam Raden Rahmat, Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.70609/gtech.v10i4.115432

Abstract

Hazard reporting is an essential part of occupational safety management because it helps in identifying and communicating conditions and actions that have the potential to give rise to risk. The digital hazard reporting systems used in industrial settings can be adapted as instructional media to give students experience of the occupational safety reporting process. This study aims to produce a web-based occupational safety hazard reporting prototype as a learning aid and to examine its functionality, the change in students’ knowledge, and students’ perceptions of its use. The study employed the Research and Development (R&D) method with the ADDIE model. Functional testing was conducted using black-box testing, while use of the prototype was evaluated by comparing pre-test and post-test results and administering a student perception questionnaire. Black-box testing confirmed 14 of the 15 scenarios (93.33%) as designed, the mean knowledge score rose from 80.96 to 99.65 (N-Gain 0.98, high category), and student perceptions averaged 4.86 (strongly agree). These results indicate that the Safety Report prototype can serve as a learning aid that provides simulated experience of hazard reporting in occupational safety instruction. The contribution of this study is a prototype for reporting occupational safety and health hazards, ranging from the identification of unsafe conditions and unsafe actions to the monitoring of follow-up actions on such reports, within a learning context. This pilot study involved a single group of 57 students without a comparison group; therefore, these findings should be viewed as an initial indication of the prototype’s usability, rather than as evidence of its effectiveness.
Designing a Safety Induction Video as an OSH Communication Medium for Public Facilities (Auditorium) in Building A, ITK Campus Mayati Isabella; Tri Hardiyanti Asmaningrum; Arini Anestesia Purba; Andre Saputra Pata’dungan; Archangela Adelina; Athaya Nur Khayyirah; Helmi Asril Rayhandi Putra; Kholifata Ar Rahmaana
G-Tech: Jurnal Teknologi Terapan Vol 10 No 4 (2026): G-Tech, Vol. 10 No. 4 October 2026
Publisher : Universitas Islam Raden Rahmat, Malang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.70609/gtech.v10i4.11431

Abstract

User safety in public facilities, particularly in a high-occupancy auditorium, requires structured, consistent, and easily understandable safety communication media. This study aims to design and conduct an initial evaluation of a safety induction video as an Occupational Safety and Health (OSH) communication tool at the Auditorium of Building A, Institut Teknologi Kalimantan. The analysis phase involved observing facility conditions and identifying potential hazards, which provided the basis for scriptwriting, storyboard creation, production, editing, and video revisions. The trial involved 30 students selected using purposive sampling, utilizing a 20-question multiple-choice pre-test and post-test instrument. The resulting video covers essential safety information, including safety facilities, fire procedures, fire extinguisher operation using the PASS method, evacuation routes, assembly points, earthquake safety actions, and an integrated sign language interpreter. Evaluation results showed an increase in the respondents' average knowledge score, rising from 79.67 on the pre-test to 98.00 on the post-test. Concurrently, the standard deviation dropped from 18.520 to 2.491. Descriptively, these findings demonstrate that respondents gained a higher and more consistent understanding of safety protocols after watching the video, confirming that the developed media is viable for OSH communication in the auditorium.
Development of an AI-Based Awkward Working Posture Detection System Using the REBA Method with Edge Computing and Deep Learning Approaches in Industrial Workshops Anis Rohmana Malik; Novita Lizza Anggraini; Putri Gesan Prabawa Anwar; Ridho Mufrih Jazil; Andre Saputa Pata’dungan; Athaya Nur Khayyirah; Archangela Adelina; Muhammad Fatwa Al Choiri
JTI: Jurnal Teknik Industri Vol 12 No 2 (2026): December 2026
Publisher : Universitas Islam Negeri Sultan Syarif Kasim Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24014/jti.v12i2.40725

Abstract

Awkward working postures pose ergonomic risks in industrial workshops, particularly when combined with force, repetition, or prolonged exposure. This study implements a human-in-the-loop ergonomic assessment system integrating MediaPipe Pose, Rapid Entire Body Assessment (REBA), and edge computing. A Jetson Orin Nano processes uploaded media and Real Time Streaming Protocol (RTSP) camera streams. MediaPipe estimates 33 body landmarks to calculate six segment angles, while HSE personnel verify landmark placement and task factors before final scoring. The system stores assessment records in MySQL and displays them through a web dashboard. Four workshop postures involving low-workpiece handling, pipe maintenance, grinding, and welding demonstrate system functionality. System-derived REBA scores were 5 for squatting (Case A) and conditionally 5 for bending (Case B). Case B's final score was withheld because wrist visibility fell below 0.50. Observer scores were 7 and 5, respectively, with both cases classified as medium risk. Grinding and welding cases were evaluated without observer comparisons. Segment agreement reached 3/5 for Case A and 5/5 for Case B. During a two-hour RTSP test involving 93,729 frames, mean latency was 74.14 ± 19.64 ms, throughput reached 13.04 ± 2.08 FPS, and CPU/GPU utilization averaged 21.35%/57.71%. Findings demonstrate operational feasibility while identifying hip-landmark placement and occlusion as key sensitivity factors. However, these descriptive results neither establish measurement accuracy nor demonstrate reduced musculoskeletal disorder incidence. Further instrument-based validation across diverse postures and operating conditions remains necessary to establish measurement reliability and broader practical applicability.