cover
Contact Name
Benny Hidayat, PhD
Contact Email
bennyhidayat@ft.unand.ac.id
Phone
-
Journal Mail Official
bennyhidayat@ft.unand.ac.id
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
Jurnal Rekayasa Sipil
Published by Universitas Andalas
ISSN : 18582133     EISSN : 24773484     DOI : -
Core Subject : Engineering,
Jurnal Rekayasa Sipil' translated as Civil Engineering Journal, is a scholarly periodical that published by Civil Engineering Departement, Faculty of Engineering, Andalas University (Unand), Padang, West Sumatra, Indonesia. The journal, abbreviated as JRS-Unand, covers recent topics in civil engineering as stated in its focus and scope. JRS-Unand publishes 6-10 articles in each edition with 8-14 pages long for each article. One volume of JRS-Unand divided into two editions, which published in February and October each year. Articles are written in Bahasa Indonesia (Indonesian language) or can be in English.
Arjuna Subject : -
Articles 6 Documents
Search results for , issue "Vol 11, No 1 (2015)" : 6 Documents clear
KINERJA PERKUATAN TEBING SALURAN DENGAN BRONJONG DI BELOKAN 120O AKIBAT BANJIR BANDANG (UJI EKSPERIMENTAL DI LABORATORIUM) Darwizal Daoed; Sunaryo Sunaryo; Bambang Istijono; Wahyu Putra Utama
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1460.972 KB) | DOI: 10.25077/jrs.11.1.11-22.2015

Abstract

Kawasan perbukitan yang mana kemiringan lerengnya sangat tajam dan tajam, yakni lebih dari 30o sangat sering terjadi keruntuhan tebing. Akibat keruntuhan tebing ini akan menyebabkan lembah tertimbun oleh material tanah, batuan dan pohon. Ketika curah hujan besar dan intensitas tinggi lembah akan terisi air, sedangkan debit air yang mengalir relatif kecil. Hal ini disebabkan oleh adanya tumpukan material runtuhan yang berada di lembah yang secara tidak langsung berfungsi sebagai bendung alamiah. Suatu ketika bendung ini akan jebol dan terjadilah banjir bandang (flashflood). Banjir bandang dapat merubah geometri saluran, terutama pada daerah belokan. Trase belokan akan berubah menjadi lurus akibat hantaman banjir. Disamping merubah alur aliran dapat juga memperlebar dasar saluran. Untuk mempertahankan agar saluran tidak berubah secara geometrik, maka dilakukan pembuatan dinding bronjong sebagai perkuatan. Tetapi dari sekian banyak dinding bronjong yang dibuat ada beberapa yang tidak berfungsi dengan baik. Dimana kelihatan dalam jangka waktu kurang dari dua tahun dinding dari bronjong sudah runtuh. Ketidakstabilan bronjong disebabkan oleh daya rusak air yang membentur tebing saluran. Benturan air ke sisi luar dan kembali ke sisi dalam membentuk gerakan spiral menuju ke hilir tikungan. Pada penelitian terdahulu sisi luar tikungan pada bagian hilir dominan tergerus dan pada sisi dalam terjadi penumpukan sedimen (Daoed, Februarman,2008). Untuk itu perlu dilakukan perkuatan pada sisi luar belokan dan dilakukan pengujian terhadap kinerja bronjong pada ujung hilir tikungan dan awal tikungan. Hasil yang diperoleh menunjukkan bahwa, keruntuhan bronjong tejadi pada awal dan akhir tikungan, dan setelah diperkuat dengan perkuatan gabungan arah horizontal dan vertikal (menjadikan elemen struktur lebih kompak), dan kemiringan dasar saluran ekstrim yakni hingga 7%, terlihat hanya bagian hilir tikungan saja yang mengalami keruntuhan. Sebaliknya untuk kemiringan lebih terjal, maka keruntuhan semakin cepat. Ini menunjukan, bahwa bagian hilir tikungan perlu didesain dengan perkutan yang lebih stabil.
PENGARUH PERKUATAN PELAT CFRP TERHADAP PERILAKU TULANGAN TARIK STRUKTUR BALOK BETON BERTULANG Elfania Bastian; Rendy Thamrin; Jafril Tanjung
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (322.663 KB) | DOI: 10.25077/jrs.11.1.23-30.2015

Abstract

Dalam studi ini dilakukan analisis numerik tentang pengaruh perkuatan dengan pelat CFRP (Carbon Fiber Reinforced Polymer) terhadap tegangan tulangan tarik. Tegangan pada tulangan tarik ditinjau pada daerah sekitar perletakan balok sederhana dengan dua tumpuan. Untuk maksud tersebut serangkaian model numerik dipersiapkan dengan jenis tulangan yang berbeda. Dimana panjang penyaluran tambahan divariasikan 100mm dan 250mm. Tulangan yang digunakan adalah tulangan baja dan GFRP (Glass Fiber Reinforced Polymer). Hasil analisis menjelaskan bahwa perkuatan dengan pelat CFRP dapat meningkatkan kapasitas balok dimana tegangan yang diterima oleh tulangan tarik menurun. Disamping itu tulangan tarik GFRP juga terbukti efektif meningkatkan daktilitas balok beton bertulang.
MODEL UNTUK PENETAPAN TARIF ZONA PARKIR (STUDI KASUS KOTA PADANG) Asrizal Asrizal
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (110.955 KB) | DOI: 10.25077/jrs.11.1.31-40.2015

Abstract

Parking problem in Central Business District (CBD) of Padang City is the use of parking space on the roadside, especially on the Pasar Raya street that has exceeded capacities. Meanwhile, request of the parking space on the roads surrounding is still below the available capacity. To balance the demand and supply of the parking space in this area, a research is conducted to make a change of parking management through applying different tariff for different zones of parking. Tariff of parking in zone which have been identified, is calculated with equation of linear regression model which pursuant to probability of Willingness to Pay by service users. The antecedent survey which conducted to some respondent, indicate that factors such as tariff, distance, duration and accessibility, having an effect which enough to influence the probability of service user in choosing of location of parking. All factors did not correlate each other. Then, a research was conducted by collecting samples of data to 100 respondents through questioner survey and interview. The format of questioner was designed by using design of experiment "FULL FACTORIAL" which consisted of 4 attribute and 2 levels at existing condition and hypotheses. The result of survey was processed by using Spreadsheet Software with a multiple linear regression model, where Y is the function of utilities to Tariff (X1), Distance (X2), Duration (X3) and Accessibility (X4). The results of survey show the majority of respondent characteristic are males and the range of age is between 26-43 years. They are commonly private employee, and their average income are about Rp. 2.000.000 – Rp. 3.000.000 per month. From the data analysis of stated preference, an equation model of Y = 2.9123 – 0.0005 (X1) – 0.0133 (X2) 0.0225 (X3) – 0.0208 (X4) was obtained, value of R2 was 0.70 and has qualified the statistical test. The model was more sensitive to change of distance and duration of parking. From the application of model pursuant to Willingness to Pay by service user at the CBD area of Padang, it was obtained that the tariff of parking are Rp. 3.198 for zone 1 and Rp. 2.392 for zone 2.
MODULUS ELASTISITAS DAN KEKUATAN LENTUR BALOK KAYU LAMINASI Fengky S. Yoresta
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (118.293 KB) | DOI: 10.25077/jrs.11.1.41-44.2015

Abstract

Penelitian ini dilakukan untuk menentukan pengaruh penggunaan paku dan perekat serta diameter paku terhadap Modulus Elastisitas (MOE) dan kekuatan lentur (MOR) balok kayu laminasi. Pengujian lentur dilakukan dengan metode pembebanan terpusat di tengah bentang (one-point loading method). Hasil penelitian menunjukkan bahwa posisi penempatan paku dan perekat tidak berpengaruh signifikan terhadap nilai MOR balok, akan tetapi memiliki pengaruh signifikan terhadap nilai MOE. Selain itu, diameter paku tidak berpengaruh signifikan baik terhadap nilai MOE maupun MOR.
STUDI ANALISIS PERILAKURAFT-PILED FOUNDATION BERDASARKAN METODA ELEMEN HINGGA 3D NONLINIER Harpito Harpito; Abdul Hakam; Rina Yuliet
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (622.571 KB) | DOI: 10.25077/jrs.11.1.1-10.2015

Abstract

Simulasi numerik dengan menggunakan metoda elemen hingga 3D non linier SAP2000 pada raft-piled foundation yang dibebani secara vertikal disajikan dalam makalah ini. Untuk studi perbandingan, model numerik raft foundation dan group pile foundation sudah di teliti sebelumnya. Model numerik yang mengadopsi hukum konstitutif elastis non linier untuk bahan. Beban dan perpindahan vertikal dari model yang diamati. Perilaku raft-piled foundation dibandingkan dengan group pile foundation ini kemudian diselidiki. Hasil dengan menggunakan beban eksternal yang sama menunjukkan bahwa raft-piled foundation memiliki penurunan terkecil dibandingkan dengan yang lain. Dalam hal tagangan, raft menunjukkan kontribusi transfer beban ke tanah di bawahnya kemudian juga pile. Dalam satu sistim raft-piled foundation memiliki sinergity impact. Dalam rangka untuk memperkirakan daya dukung sistem raft-piled foundation, disarankan bahwa kontribusi raft harus dimasukkan dalam penambahan pile. Daya dukung total sistim raftpiled foundation merupakan penjumlahan dari kapasitas masing-masing pile ditambah dengan kapasitas dari raft di atas pile.
STUDI PARAMETER MIKROSKOPIK DAN MAKROSKOPIK ARUS LALU LINTAS AKIBAT PENGARUH “RUMBLE STRIPS” TERHADAP PERILAKU PENGEMUDI DI KAMPUS LIMAU MANIS UNIVERSITAS ANDALAS Putri Oktafiani Muchlis; Purnawan Purnawan; Hendra Gunawan
Jurnal Rekayasa Sipil (JRS-Unand) Vol 11, No 1 (2015)
Publisher : Civil Engineering Departement, Andalas University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (756.779 KB) | DOI: 10.25077/jrs.11.1.45-58.2015

Abstract

Kecelakaan lalu lintas sebagian besar disebabkan oleh pelanggaran terhadap peraturan keselamatan lalu lintas, hal ini menunjukan bahwa kesalahan manusia secara mandiri bertanggung jawab terhadap hampir 50% kejadian. Penelitian ini bertujuan untuk mengetahui kecepatan kendaraan ketika melewati rumble strips yang ada di kampus Limau Manis UNAND. Penelitian dilakukan di lima lokasi rumble strips yang ada di kampus Limau Manis UNAND. Pengumpulan data di lapangan yaitu data volume lalu lintas, kecepatan,kepadatan dan time headway. Survei dilakukan di tanggal 14 Juni 2013- 4 juli 2013 pada hari kerja (jam 08.45 WIB sampai jam 17.30 WIB). Pengukuran dilakukan sebelum lokasi Rumble Strips, dilokasi rumble strips, kecepatan kendaraan saat akan meninggalkan lokasi rumble strips, saat meninggalkan lokasi rumble strips. Kecepatan rata-rata kendaraan mengalami penurunan sebayak 10,6% ketika melewati lokasi rumble strips dibandingkan dengan kecepatan rata-rata kendaraan sebelum melewati lokasi rumble strips. Kerapatan ratarata kendaraan dilokasi rumble strips mengalami pertambahan 10,8% dibandingkan lokasi sebelum rumble strips. Time headway rata-rata kendaraan mengalami penurunan 14,3% ketika melewati lokasi rumble strips dibandingkan sebelum melewati lokasi rumble strips. Analisis untuk perbandingan pengujian penurunan kecepatan kendaraan ketika melewati rumble strips dengan menggunakan uji z dan t dengan uji Chi-Square. Hasil analisis pengaruh rumble strips terhadap tingkat kecepatan kendaraan di rumble strips menunjukkan penurunan kecepatan, nilai kerapatan semakin besar ketika melewati rumble strips dibandingkan sebelum atau sesudah rumble strips, time headway ketika melewati rumble strips semakin kecil dibandingkan sebelum melewati rumble strips.

Page 1 of 1 | Total Record : 6