cover
Contact Name
Dwiprayogo Wibowo
Contact Email
dwiprayogo@umkendari.ac.id
Phone
+6285340122344
Journal Mail Official
j.lingk@umkendari.ac.id
Editorial Address
Jl. KH. Muh. Dahlan No.10, Wowawanggu, Kec. Kadia, Kota Kendari 93127, Sulawesi Tenggara
Location
Kota kendari,
Sulawesi tenggara
INDONESIA
Jurnal TELUK: Teknik Lingkungan UM Kendari
ISSN : 27974049     EISSN : 27975614     DOI : 10.51454
Jurnal TELUK: Teknik Lingkungan UM Kendari merupakan media informasi bagi para dosen, mahasiswa, dan praktisi yang menaruh minat serta perhatian pada pengembangan inovasi dibidang Teknik Lingkungan, meliputi: (1) Perencanaan dan Perancangan Lingkungan; (2) Ilmu dan Teknologi Lingkungan; (3) Geohidrologi dan Hidrologi Lingkungan; (4) Pengelolaan dan Pengolahan Limbah; (5) Pencemaran Udara; (6) Mikrobiologi Lingkungan; (7) Ekologi atau ilmu lingkungan; (8) Kimia Lingkungan
Articles 40 Documents
Pemodelan PM2,5 pada Musim Kemarau menggunakan Software Graz Lagrangian Model di Kecamatan Kota Baru, Kota Jambi Mayra Alviani; Febri Juita Anggraini; Zuli Rodhiyah
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 2 No. 2 (2022): Edisi Desember Tahun 2022 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v2i2.777

Abstract

Particulate Matter 2.5 (PM2.5) is one type of pollutant with a size of less than 2.5 microns which can cause increased mortality due to exposure. PM2.5 can be generated from natural activities, motor vehicles, industrial activities, and household activities. PM2.5 in Jambi City continues to increase from year to year until it is included in the dangerous category in 2019, with a concentration of 39.25 g/m3. Graz Lagrangian Model (GRAL) is an application that can model air pollution by entering meteorological data and pollutant concentrations. This study aims to determine the results of measuring the concentration of PM2.5 in Kota Baru District, Jambi City during the dry season and its comparison with the applicable quality standards and to model the distribution of PM2.5 in the Jambi City area using GRAL. The research was conducted in Simpang Tiga Sipin Village, Kota Baru District, Jambi City. In this study, measurements were carried out 3 times per month on weekdays for 72 hours. It is known that the average concentration of PM2.5 during the months of May, June, July and August 2021, respectively, is 30.32 µg/m3, 63.29 µg /m3, 43.66 µg/m3, and 26.26 µg/m3. The GRAL simulation results show that the areas that are often exposed to PM2.5 are Alam Barajo, Telanaipura, and Danau Sipin Districts.
Analisis Kualitas Air Perusahaan Daerah Air Minum Unit Anduonohu Asnah Junitriani Gani; Rosdiana Rosdiana; Wa Ndibale
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 2 No. 2 (2022): Edisi Desember Tahun 2022 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The quality of clean water is an important factor in all matters, especially for the Regional Drinking Water Company (PDAM) which will distribute clean water to the community. Maintaining the quality of clean water to avoid contaminants is something the needs to be considered. Therefore, it is necessary to periodically test water quality in order to maintain the quality of clean water obtained, such as testing the level of turbidity and Fe (iron). In this study, the result of the analysis of water quality testing parameters of turbidity and Fe (iron) at each point namely point 1, point 2, point 3, and point 4 had different result. The turbidity level obtained at point 1 (reservoir) was 0,8 NTU, increased at point 2 to 0,81 NTU and again increased at point 3 to 0,82 NTU. Then at point 4, the result obtained are back to 0,8 NTU. While the result of the analysis of the content of iron (Fe) obtained at point 1 (reservoir) is 0,006 mg/L, while at point 2 and point 3 the same results are obtained, namely 0,0052 mg/L, then at point 4 it is much increased to 0,02 mg/L. Things that effect the result of the analysis obtained at each point, including the difference in distance and contours of the soil at each point.
Analisis Pencemar PM10 Pada Udara Ambien Akibat Aktivitas Kendaraan Bermotor : (Studi Kasus: Jalan Poros Puuruy-Morosi, Desa Puuruy, Kecamatan Morosi, Kabupaten Konawe) Nanda Nurhalifa; Ilham Ilham; Sumarlin Sumarlin
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 2 No. 2 (2022): Edisi Desember Tahun 2022 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Indoor and outdoor air pollution (indoor and outdoor pollution), Dust is often used as an indicator of environmental pollution indicating the level of danger to the environment, Particulate Matter PM10 is one of the air pollutants classified as primary pollutant, Pollutants Released Directly into Air from Pollution Sources Such as motor vehicle activity. PM10 particulate matter levels were measured using an Air Quality Monitor. This study shows the concentration of PM10 on Jalan Poros Puuruy Morosi in the morning reached 51.63 g/Nm3, 39.91 g/Nm3, and was still in safe levels for humans. However, in the afternoon the concentration of PM10 particulate matter increased and reached 97.83 µg/Nm3 exceeding the quality standard of 75 µg/Nm3.
Optimalisasi Pelayanan Pemenuhan Kebutuhan Air Bersih Masyarakat Wakorumba Utara, Kabupaten Buton Utara : Studi Kasus Program Penyediaan Air Minum dan Sanitasi Berbasis Masyarakat Labora Anisah; Surya Baskara; Aryani Adami
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The need for clean water each year generally increases, while the availability of clean water is increasingly limited. At first, local people at North Wakorumba used dug wells, river water, and rainwater to meet their needs for clean water. Along with the development to drill wells and river water, the government provided clean water, although only in certain villages in the sub-district. This type of research is descriptive-quantitative, a study to determine the clean water needs of the people at North Wakorumba, North Buton Regency, and reviewing spring discharge. The primary data are from the people of the North Wakorumba District, North. The secondary data used in population and customer data at PAMSIMAS Labora. Service optimization occurs at the PAMSIMAS Labora discharge and the intake and reservoir basins. The population projection for the next 10 years is 5,199 people, with the community's need for clean water in the research area for the next 10 years in 2031, which is 14.389 liters/second. With a total water debit of 18 liters/second.
Estimasi Emisi Kendaraan Bermotor untuk Memprediksi Beban Pencemar Udara CO dan NOx di Tempat Pelelangan Ikan Kota Kendari Arisman Arisman; Rosdiana Rosdiana; Aryani Adami
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Transportation has a positive impact in supporting community activities and helps determine regional development through the distribution of goods and services, besides that it also has a negative impact on the environment, especially air quality in urban areas. Fish Auction Place is a place that is usually located in a port or fish landing base and in that place, there is a sale of fish and marine products either by auction or not. This study aims to observe the prediction of motor vehicle emission load by using analytical prediction studies and simple statistical data about the possible estimates of vehicle emissions produced by motorized vehicles at the Kendari City Fish Auction Place. Based on the results of the study, the volume of vehicle traffic passing at the Kendari City Fish Auction Place was 1,774 vehicles/hour, 8,517 vehicles/day, and 3,100,664 vehicles/year. The type of motorcycle vehicle is the vehicle that passes the most while the bus is the vehicle that passes the least at the research location. It is known that the largest CO emission load is produced by motorcycle vehicles, which is 3.8981 tons/year, and the smallest is produced by buses at 0.0011 tons/year. While the largest NOx emission load is generated by diesel-fueled cars, which is 0.1369 tons/year and the smallest is generated by bus vehicles, which is 0.0012 tons/year.
Studi Timbulan, Komposisi dan Potensi Daur Ulang Sampah di Kompleks Perumahan BTN Gemilang 2 Residence dwi saputra; Wa Ndibale; Moch. Assiddieq
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v3i1.965

Abstract

The Watubangga Subdistrict is the second most densely populated area in the Baruga District. However, the sanitation and waste management in the subdistrict are still inadequate. Waste management facilities and waste collection points in the area need to be improved. BTN Gemilang 2 Residence, which is part of the subdistrict, was selected as the research and sampling location. It consists of 62 Type 36 buildings occupied by approximately 162 residents, and it is expected to experience an increase of around 148 residents. This research aims to analyze the generation, composition, and recycling potential of waste in the residential area. Data were obtained through sampling in the residential area, which were then measured and analyzed. The analysis involved sorting the waste into eight components and determining the recyclable waste potential. The research results indicate that the daily waste generation in the residential area amounts to 41.85 kg. Food waste is the most dominant component, followed by hazardous waste, plastic, paper, glass, textiles, and metal. The recycling potential of the waste is estimated to be 57.7% of the total waste generated, consisting of PET and PP plastics, bond paper, glass, metal, and food waste. This research is expected to provide valuable information and data for policy-making and stakeholders involved in waste management in the residential area.
Analisis Nitrogen Dioksida (NO2) terhadap Penurunan Kualitas Udara Ambien: (Studi Kasus: Desa Puuruy, Kecamatan Morosi, Kabupaten Konawe, Provinsi Sulawesi Tenggara) nooraisya asrudin; Moch. Assiddieq; Rosdiana Rosdiana
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v3i1.973

Abstract

Outdoor air pollution comes from moving sources, namely exhaust fumes from burning vehicles such as motorbikes, cars, buses, trucks. Morosi sub-district is an industrial area inhabited by several mineral refining companies. The company certainly has a lot of human resources, in this case there are many jobs that use vehicles to optimize working time the mobility of workers is one of the contributors to air pollution because of incomplete combustion residue from transportation equipment known as Nitrogen Dioxide (). Efforts to monitor the amount of pollutant ) need to be carried out considering the impacts that will arise in the future. Measurenment of content () was carried out using measurement procedures referring to SNI 19-71196-2005, using an impinge and a spectrophotometer. This study shows the concentration ) on the Puuruy-Morosi road in the morning reached 85.90 µg/m³,70.30µg/m³ afternoon and 106.20µg/m³ in the afternoon and is still within safe levels for humans because it has not exceeded the air quality standard of 200 µg/m³.
Analisis Kualitas Air Sungai Lasolo di Kecamatan Kendari Barat Kota Kendari maharani maharani; Rosdiana Rosdiana; Wa Ndibale
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v3i1.974

Abstract

This study aims to analyze the quality of the Lasolo River water, compare it with the quality standard for class I PP Number 22 of 2021, and determine the Status of Water Quality using the Pollution Index (IP) method according to the Minister of Environment Decree Number 115 of 2003. Water quality measurements were carried out at 4 points while the parameters measured were pH, TSS, and Fecal Coliform. Based on the data, it was found that the water pH parameter fluctuated between 7.0 to 7.8 obtained at points ST1 to ST4 under normal conditions, which explained that Lasolo River water met the established quality standards. An increase in the TSS parameter is shown at each point with an average of 70-74 mg/L range, which explains that the TSS value exceeds the maximum water quality standard limit of 40 mg/L. In contrast, the Fecal Coliform parameter at each sampling point has a measurement value of 0 MPN/100 mL, which means it is below the standard quality limit of 100 MPN/100 mL. The water quality status of the Lasolo River was determined using the Pollution Index (IP) method and found that all sampling points were in "lightly polluted" conditions with a range of pollution values between 1.0 < Plj ≤ 5.0 according to Ministerial Decree No. LH. 115 of 2003.
Pengaruh Kebisingan Terhadap Kelelahan Dalam Pekerjaan Pembangunan SUTT 150 kV Raha Bau-bau Section 1 Jaka Adiprasetya Wiraantaka; Ilham Ilham; Sumarlin Sumarlin
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v3i1.975

Abstract

The construction of transmission line is one of the national strategic projects to even out development, especially with regard to the need for electric power. The construction of transmission line Raha – Baubau will connect two islands in Southeast Sulawesi Province, namely Muna Island and Buton Island. PT PLN (Persero) UPP Sulawesi Tenggara as the project director on this project is very concerned about K3 (Occupational Safety and Health) starting from the planning, work, testing and operation stages. Measurements of the work environment have been routinely carried out every semester but there has never been a study on the impact of noise on worker fatigue in the field. The sources of noise during this construction work include breakers, concrete mixers, ironworks, erection towers and stringing machines. With a total workforce of ±80 people and work intensity/noise exposure of 8 hours/day and the impact of noise risks that are not yet known, it is necessary to conduct research to identify and mitigate the risks of fatigue due to noise in the construction work of transmission line Raha-Baubau Section 1.
Desain Perencanaan Instalasi Pengolahan Air Limbah Domestik : Studi Kasus : Pondok Pesantren Attabiyatussakilah Kendari Muh. Alminsyah; Ilham Ilham; Wa Ndibale
Jurnal TELUK: Teknik Lingkungan UM Kendari Vol. 3 No. 1 (2023): Edisi Juni Tahun 2023 Jurnal TELUK: Teknik Lingkungan UM Kendari
Publisher : Program Studi Teknik Lingkungan, Universitas Muhammadiyah Kendari

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51454/teluk.v3i1.977

Abstract

This research aims to understand the existing condition of domestic wastewater treatment at Pondok Pesantren Attabiyatussakilah Kendari. It aims to identify the characteristics of wastewater generated at Pondok Pesantren Attabiyatussakilah Kendari. It also aims to design a domestic wastewater treatment installation for Pondok Pesantren Attabiyatussakilah Kendari. The methods used in this research are quantitative, qualitative, and experimental. The research findings indicate that the existing domestic wastewater treatment installation at Pondok Pesantren Attabiyatussakilah Kendari is currently absent. Generally, the wastewater is discharged into the drainage system without undergoing any treatment process. The calculated wastewater flow rate is 19.75 m3/day. The planned dimensions of the wastewater treatment plant (IPAL) consist of a sedimentation tank (settler) with dimensions of 3.35 m × 3.30 m × 3.54 m and an Anaerobic Filter (AF) tank with dimensions of 1 m × 3.32 m × 2.40 m.

Page 4 of 4 | Total Record : 40