Inovasi Fisika Indonesia (IFI)
ISSN : 23024216     EISSN : 28301765     DOI : https://doi.org/10.26740/ifi
Jurnal Inovasi Fisika Indonesia(IFI) is a peer-reviewed journal, ISSN: 2302-4216, which is managed and published by the Department of Physics, Faculty of Mathematics and Natural Sciences (FMIPA) Universitas Negeri Surabaya (UNESA). This journal is accessible to all readers and covers developments and research in physics (Materials Physics, Earth Physics and Instrumentation Physics).
Articles 415 Documents
korelasi ANTARA AZIMUT STASIUN DENGAN DURASI RUPTURE GEMPA BUMI DI PULAU SUMATERA IRMA FITRIANI
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (602.176 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Pulau Sumatera yang terletak di bagian barat Indonesia, merupakan satu dari beberapa wilayah di negara ini yang rawan gempa bumi. Pulau ini tergolong rawan gempa karena terdapat titik pertemuan antara lempang Eurasia dengan lempeng Indo-Australia yang kemudian menghasilkan trench Sunda. Selain itu, tercatat beberapa gempa berskala lebih dari 5 SR mengguncang pulau ini yang menimbulkan keresahan warga tentang potensi terjadinya gempa susulan. Tujuan penelitian ini adalah menemukan korelasi antara azimut stasiun dengan durasi rupture, dan hubungan antara durasi rupture dengan arah rupture. Metode yang digunakan dalam penelitian ini ialah dengan metode langsung yaitu dengan mengolah durasi rupture (Tdur) menggunakan software Joko Tingkir dimana data tersebut diperoleh dari (https://ds.iris.edu/wilber3/) periode 2007-2012, dan azimut stasiun yang diperoleh dari website yang sama. Kemudian dengan menggunakan sotfware Data Tool didapatkan persamaan korelasi antara durasi rupture (Tdur) dengan azimut stasiun dan pada website plot.ly, didapatkan grafik korelasi antara keduanya. Dari hasil penelitian ini diperoleh korelasi antara azimut stasiun dengan durasi rupture berbentuk sinusoida dengan R-Squared pada masing-masing kejadian gempa sebesar 0.9264, 0.7125, 0.8932, dan 0.9353. Dan pada penelitian ini diperoleh pula bahwa hubungan antara durasi rupture dengan arah rupture menyerupai Efek Doppler, yakni semakin dekat dengan arah rupture, maka durasi rupture akan semakin singkat, begitupun sebaliknya.. Kata kunci: korelasi, gempa bumi, azimut stasiun, durasi rupture, arah rupture Abstract Sumatra island located in the western part of Indonesia, is one of several regions in this country prone to earthquakes. This island classified as prone to earthquakes because there is a meeting point between Eurasia straight forward with the Indo-Australian plate which then generates the Sunda trench. In addition, there were several earthquakes over magnitude 5 SR which shake the island raises concerns of citizens about the potential occurrence of aftershocks. Purpose of this study are found a correlation between the azimuth station with the duration of rupture, and get the relationship between the duration of the rupture with the direction of rupture. The method used in this research is the direct method is to process the duration of rupture (Tdur) using software Joko Tingkir where the data is obtained from (https://ds.iris.edu/wilber3/) in the period 2007-2012, and azimuth station obtained from the same website. Then, using equations obtained sotfware Tool Data correlation between the duration of rupture (Tdur) with azimuth stations and on the website plot.ly, obtained graph the correlation between the two. From the results of this study showed a correlation between the azimuth station rupture duration sinusoidal shape with R-Squared at each occurrence of the earthquake of 0.9264, 0.7125, 0.8932, and 0.9353. And in this study showed also that the relationship between the duration of the rupture with the direction of rupture resembles the Doppler effect, which is closer to the direction of rupture, the rupture will be more brief duration, vice versa. Keywords: correlation, azimuth station, the duration of rupture, the direction of rupture.
PERANCANGAN DAN PENGUJIAN PENAKAR HUJAN TIPE TIPPING BUCKET DENGAN SENSOR PHOTO – INTERRUPTER BERBASIS ARDUINO RYAN GALIH PERMANA
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (352.588 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian ini bertujuan untuk merancang penakar hujan dengan metode tipping bucket yang digunakan untuk memperoleh data curah hujan. Penakar hujan ini menggunakan prinsip dasar dari pengungkit yang terbuat dari 2 buah bucket. Bucket – bucket tersebut akan bergantian menghitung jumlah volume air yang masuk kedalam mulut corong penakar ini, kemudian volume air tersebut dikonversikan kedalam satuan curah hujan yaitu milimeter (mm). Perhitungan curah hujan dilakukan setelah air melewati bucket yang berjungkit sehingga menggerakkan penghalang untuk melewati sensor photo-interrupter yang berfungsi untuk mengaktifkan program perintah counter. Hasil dari perhitungan tersebut ditampilkan kedalam microsoft excel dengan menggunakan software PLX-DAQ. Nilai curah hujan pada penakar hujan ini sebesar 0.35 mm atau 14 ml/tipping. Pengujian penakar hujan ini dengan metode membuat simulasi hujan dan memanipulasi laju aliran air. Kesalahan pengukuran diperoleh dengan cara dibandingkan dengan volume air buangan penakar hujan yang ditampung pada bak penampungan dan diperoleh nilai kesalahan terbesar 1,37% pada simulasi pertama, 0,64% pada simulasi ke-dua, 3,70% pada simulasi ke-tiga, dan 1,56% pada simulasi ke-empat. Nilai kesalahan ini didapatkan dari nilai volume maksimum air pertipping ± 14 ml, tidak selalu tepat pada 14 ml. Kata kunci : curah hujan, tipping bucket, photo-interrupter. Abstract This research aimed to design a rain gauge which use tipping bucket method. This rain gauge is used for gain rain fall data . The rain gauge based on basic principle of a lever that made from 2 pieces of buckets these buckets will count the water volume that come to the mouth of the gauge. Furthermore the water volume was converted into rain fall unit of milimeter (mm). The calculations of rainfall was done after water pass from bucket which tilled up so that the hindrance was moved to pass photo-interrupter sensor, which the function is to activate the program of counter command. The result from the calculation was shown in Microsoft excel using PLX-DAQ software. The rain fall value of gauge is 0,35 mm or 14 ml/tipping. This rain gauge examination with simulated rain and manipulate the flow rate of water. Measurement error is obtained by comparison with the volume of waste water a rain gauge which collected on tanks and obtained the error of 1,37% in the first simulation, 0,64% in the second simulation, 3,70% in the third simulation, and 1,56% in the fourth simulation. The error was got from maximum value water per tipping ± 14 ml, not always acculate in 14 ml. Keyword : rain gauge, tipping bucket, photo-interrupter.
Perancangan kit percobaan untuk pengukuran sudut deviasi dan indeks bias prisma RYANTONO EKA SAPUTRA
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (726.744 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian laboratorium ini bertujuan untuk mengetahui dan mempelajari nilai indeks bias prisma melalui pengukuran sudut deviasi dari tiap-tiap sudut datang cahaya. Kit percobaan yang dirancang menggunakan rotary encoder berbasis mikrokontroler yang menghasilkan data digital untuk mengukur nilai sudut pada lengan sumber cahaya dan lengan penerima cahaya. Hasil pembiasan prisma dan dibandingkan dengan nilai sudut pada busur yang ada pada kit. Data yang didapatkan berupa sudut datang dan sudut deviasi diolah menggunakan microsoft excel. Nilai indeks bias hasil pengukuran didapatkan saat sudut deviasi minimum, dan nilai indeks bias tersebut dibandingkan dengan Spectrometer. Perbandingan nilai kalibrasi sudut dapat diketahui dengan hasil pengukuran yang dilakukan pada busur dan rotary encoder didapat rata-rata kesalahan sebesar 0,65%. Pada pengukuran sudut deviasi didapatkan kesalahan terbesar 0,15% pada prisma sudut pembias 45° dan untuk prisma sudut pembias 60° didapatkan kesalahan terbesar 0,16%, sedangkan nilai indeks bias yang didapatkan untuk prisma sudut pembias 45° didapatkan nilai indeks bias sebesar 1,43 dengan kesalahan 0,07% dan untuk prisma sudut pembias 60° didapatkan nilai indeks bias sebesar 1,49 dengan kesalahan 0,15%. Hasil yang didapatkan lebih akurat dari penelitian sebelumnya dikarenakan alat yang dirancang telah dikalibrasi dengan tingkat keakuratan 99,35%. Kata kunci : sudut deviasi, rotary encoder, indeks bias Abstract This research aims to measure flow of water in form of speed and flow rate by designed and produced venturimeter and water flow sensor. The apparatus is being compared to evaluate the result of measurement, venturimeter with manual data and water flow sensor with digital data. The research is based on laboratory to study about dynamic fluid system in measuring flow rate of water. Calculation conducts after water passed by venturimeter with record the height that shows unit of pressure in each of area manually, then water flow sensor measures with microcontroller. Parralax Data Acquisition (plx-DAQ) is an acquisition microcontroller data for Microsoft Excel. Checking for calibration is done to water flow sensor. It uses to compare result of measurement with venturimeter. Venturimeter gives result of knop angle to get the flow rate of water pump. Flow rate is constantly proportional to the height difference that shows unit of pressure, flow rate is constantly reverse to the surface area. Measurement of flow rate by venturimeter and water flow sensor has error significance 1.75%. The difference gets from result of flow rate reference in venturimeter that has accuracy or appropriate with theory and Water Flow Sensor that has been calibrated in Perusahaan Daerah Air Minum (PDAM) that can measure precisely. Keywords: Flow rate, water flow sensor, pipe venturimeter.
PERANCANGAN KIT PERCOBAAN GERAK LURUS BERUBAH BERATURAN PADA BIDANG MIRING DWI KURNIAWAN
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (759.328 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian dan perancangan KIT percobaan gerak lurus berubah beraturan pada bidang miring bertujuan untuk membuat alat yang digunakan sebagai simulasi pembelajaran gerak lurus berubah beraturan pada bidang miring serta mengkaji teori-teori yang relevan. KIT ini terdiri dari lintasan sepanjang satu meter yang dilengkapi lima buah sensor phototransistor yang dipasang dengan jarak 25 cm, kerangka bidang miring yang dilengkapi rotary encoder sebagai penentu kemiringan lintasan serta mikrokontroller sebagai penghitung waktu dan pengolah data. Lima buah sensor yang terpasang pada lintasan digunakan untuk mendeteksi pergerakan troli selama melintasi bidang miring. Sehingga diperoleh nilai waktu yang dihitung dan dicatat oleh mikrokontroller. Pengambilan data dilakukan pada sudut 4° sampai 15°. Dari perubahan sudut tersebut diperoleh waktu tempuh troli pada tiap sensor yang digunakan untuk menghitung percepatan troli menggunakan persamaan gerak lurus berubah beraturan. Diperoleh nilai percepatan troli dengan kesalahan terbesar pada sudut 15° secara berurutan 1, 2, 3 dan 4 adalah 2.07 m/s2, 1.88 m/s2, 1.81 m/s2 dan 1.76 m/s2. Dari data tesebut diketahui bahwa nilai percepatan semakin kecil, hal ini disebabkan oleh gaya gesek udara, dimana semakin cepat troli mana gaya gesekan udara semakin besar. Kata Kunci: Bidang miring, percepatan, gerak lurus berubah beraturan, rotary encoder, phototransistor. Abstract The purposes of this research are to observe and develop non-uniform accelerated motion apparatus on an inclined plane that used to simulate non-uniform accelerated motion on inclined plane and discuss about the theory. The components of this apparatus are one meters track with five built in phototransistor sensors with distance between sensors about 25cm, an inclined plane body with built in rotary encoder sensors that used to determine the angle of the inclined plane, also a microcontroller that used to measure travel time and acceleration of the troli. Five sensors are built in the track used to detect troli motion. So the time of troli that moved down on inclined plane can be measured with the microcontroller. The angles of the collected data are 4° until 15°. From the manipulation of the angle we get time travel and acceleration that measured with non-uniform accelerated motion equation. The troli acceleration in 15° with the acceleration calls 1, 2, 3 and 4 with each of which are 2.07 m/s2, 1.88 m/s2, 1.81 m/s2 dan 1.76 m/s2. From these value we know the acceleration of troli are decrement, in causes by air friction force, with faster troli down on incline the air force of air friction are greater. Keywords: Inclined plane, acceleration, non-uniform accelerated motion, rotary encoder, phototransistor.
RANCANG BANGUN APLIKASI LUX METER BH1750 SEBAGAI ALAT UKUR KEKERUHAN AIR BERBASIS MIKROKONTROLER AKHMAD AKHSIN NASRUDIN
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (330.834 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian ini bertujuan untuk mengetahui hubungan antara intensitas cahaya dan kekeruhan air serta mengaplikasikan Lightsensor BH1750 sebagai alat ukur kekeruhan air. Sistematika yang dirancang, yaitu dengan meletakkan sensor sejajar dengan sumber cahaya dan sampel yang akan diukur nilai kekeruhannya diletakkan diantara sumber cahaya dan sensor cahaya, dalam hal ini sumber cahaya yang digunakan adalah cahaya LED dan sensor yang digunakan dalam transmitter adalah BH1750 Sensor. Penelitian ini menggunakan padatan tersuspensi sebagai sampel yaitu nilai awal 1000 NTU, untuk mendapatkan standard formasin suspense pada tingkat kekeruhan lainnya dilakukan dengan cara pengenceran air aquades dengan perbandingan molaritas dari kekeruhan1000 NTU. Langkah awal penelitian ini adalah mengkalibrasi Lightsensor BH1750 dengan Lux Meter didapatkan keakuratan mencapai ≥ 90 %, kemudian kalibrasi antara Lightsensor BH1750 dengan Turbidimeter. Langkah berikutnya yaitu membandingkan hasil pengukuran Turbidimeter buatan dan Turbidimeter acuan. Aparatus penelitian ini diperoleh hubungan antara intensitas cahaya dengan besar kekeruhan air. Semakin tinggi nilai padatan tersuspensi nilai intensitas cahaya semakin kecil, hal ini disebabkan karena nilai kekeruhan berbanding terbalik dengan nilai intensitas cahaya. Perhitungan nilai kekeruhan diperoleh nilai kesalahan maksimum sebesar 6,38 %, Adanya perbedaan nilai yang terukur disebabkan karena keterbatasan alat hasil rancangan yang berkaitan dengan pengukuran kekeruhan air dan dapat juga dipengaruhi oleh teknik pengukuran yang kurang baik. Kata kunci : intensitas cahaya, kekeruhan air, Lightsensor BH1750. Abstract The purpose of this study is to know the connection among radiance intensity and water turbidity and applying Lightsensor BH1750 as the gauge of water turbidity. Sistematics who was designed which put censor on a line with radiance source and sample will be measured the turbidity point and put between radiance source and radiance censor, in this case radiance source which used was radiance LED and censor which used in transmitter was BH1750 Sensor. This study used formazin suspense as a sample was the first point 1000 NTU, for get the standart formasin suspension in another turbidity level was done by dilution the aquades water with comparing molaritas from 1000 NTU turbidity. The first step in this study was calibrating Lightsensor BH1750 with Lux Meter got the accuracy up to ≥ 90 %, then calibrate between Lightsensor BH1750 with Turbidimeter. The next step was comparing the result of gauging unnatural Turbidimeter and hint Turbidimeter. The aparatus of this study was got relation between radiance intensity and the big of water turbidity. The higher of the formazin suspense the grade of radiance intensity is more smaller, it caused the grade of turbidity inversely the grade of gradiance intensity. The turbidity grade calculation was got the maximum mistake grade is 6,38 %, there is differentiation the grade measured because limitedness the tool of result program which related to measuring of water turbidity and can be influenced by bad measurement technique. Key Word : Radiance Intensity, Water Turbidity, Lightsensor BH1750.
RANCANG BANGUN ALAT ELEKTROKARDIOGRAF LEAD 1 BERBASIS SOUNDCARD PADA KOMPUTER FITRI ROHMAISA
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (516.34 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian ini bertujuan untuk menentukan kecepatan detak jantung per menit menggunakan sadapan bipolar lead 1. Data sadapan kemudian diproses oleh soundcard internal pada komputer hingga menghasilkan gelombang PQRST dan diperoleh data detak jantung per menit. Penelitian ini dilakukan dengan cara menempelkan elektroda pada kedua lengan tangan dan kaki kanan. Kemudian sinyal biopotensial tersebut dihubungkan dengan penguat instrumentasi AD620 dengan penguatan total sebesar 1000 kali yang selanjutnya akan melewati rangkaian filter yaitu high pass sebesar 0,03 hz dan notch filter 50 hz. Setelah melalui proses penguatan, sinyal analog tersebut akan diolah oleh soundcard internal komputer yang berfungsi sebagai Analog Digital Converter (ADC) yang kemudian akan ditampilkan menggunakan software soundcard scope dan EKG-Monitor.jar. Dari hasil penelitian didapatkan bahwa jumlah beat per minute (bpm) dari kedua software menunjukkan nilai yang hampir sama, baik dalam keadaan rileks, setelah beraktivitas, maupun ±10 menit setelah beraktivitas. Hal ini dikarenakan kedua software mempunyai fungsi yang sama yaitu menangkap sinyal dan menampilkannya dalam grafik gelombang, sehingga sinyal yang telah dikonversi oleh ADC soundcard bisa diterima oleh kedua software dengan baik. Interval waktu dari setiap gelombang PQRST yang dihasilkan oleh software sesuai dengan karakteristik sinyal dari EKG normal dan dari hasil uji dapat disimpulkan bahwa dari ketujuh sampel mempunyai detak jantung yang normal atau bisa dikatakan mereka dalam keadaan sehat. Kata kunci : detak jantung, ECG, soundcard, filter Abstract This research aims to determine the heart rate per minute using bipolar leads 1. The data is then processed by an internal soundcard on the computer to produce a PQRST wave and the data obtained heartbeats per minute. This research was conducted by placing electrodes on both arms and right leg. Then bio-potential signal is connected to instrumentation amplifier AD620 with a total of 1000 times the strengthening then be passed through a 0.03 hz high pass filter and 50 hz notch filter circuit. After going through amplifying process, the analog signal will be processed by the computer's internal soundcard that serves as Analog Digital Converter (ADC) which will then be displayed using the soundcard scope and ECG-Monitor.jar software. The result of beats per minute (bpm) both of the softwares showed almost similar, either in a relaxed state, after activity, and ± 10 minutes after activity. This is because the software has the same function that captures the signal and displays it in a graph of wave, so the signal that has been converted by the ADC soundcard can be accepted by both the software properly. The time’s interval of each PQRST waves generated by the software according to the signal characteristics of normal ECG and the results of the test can be concluded that the seven samples have normal heart rhythms or to say they are in a good health. Keywords: heartbeat, ECG, soundcard, filter
ANALISIS SIFAT KOROSI MATERIAL PELAPIS PANi-SiO2/cat PADA MEDIUM NaCl 1M DENGAN METODE EIS DINA MILATIKA SYAHRA
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (315.697 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Korosi merupakan peristiwa kerusakan logam karena adanya faktor metalurgi dan reaksi kimia dengan lingkungannya yang menyebabkan terjadinya penurunan kualitas suatu bahan logam. Korosi pada larutan asam terutama yang mengandung klorida dapat memberikan efek korosif yang sangat agresif pada logam. Salah satu penanggulangan untuk mencegah terjadinya korosi yaitu dengan melakukan coating. Pada penelitian ini dilakukan pelapisan pada baja SS304 dengan komposit PANi-SiO2. Pembuatan komposit berbasis bahan alam meliputi ekstraksi pasir silika dari pasir bancar Tuban,Jawa Timur dan metode polimerisasi untuk mendapatkan polianilin. Komposit PANi/SiO2 dicampurkan ke dalam cat dengan perbandingan konsentrasi komposit PANi:SiO2 yaitu 97,5:2,5, 90:10, dan 85:15. Pada masing-masing komposit dilakukan karakterisasi uji korosi sampel sebelum ekpose dan sesudah ekpose (direndam NaCl 1M). Serbuk silika amorf, serbuk polianilin dan komposit PANi/SiO2 dikarakterisasi menggunakan FTIR. Baja SS304 yang sudah terlapisi dengan pelapis PANi-SiO2/cat untuk mengetahui ketahanan korosi yang paling baik dari variasi konsentrasi %berat PANi-SiO2 di uji dengan EIS (Electrochemical Impedance Spectroscopy). Hasil pengujian EIS menunjukkan bahwa pada komposisi 10% silika-90% PANi merupakan penghambat korosi paling baik dengan nilai Rp (tahanan korosi) yang paling besar baik sebelum ekpose maupun sesudah ekpose, yaitu 3760 Ω dan 7370 Ω. Kata kunci : Korosi, Electrochemical Impedance Spectroscopy, PANi, SiO2 Abstract Corrosion is event of a metal breakage which it is coused by existencing of metallurgical and chemical reactions with its surroundings which it couses event of the reduction of a metal material quality. Corrosion in acid solvent especially which it contains chloride, it can give corrosive effects which it is very aggressive on metals. One of countermeasures for preventing event of corrosion is by doing coating. In This Research is done coating at steel of SS304 by Composite of PANi-SiO2. Manufacture of composite based on natural materials,which it includes extraction of silica sand from sand of banjar Tuban Jawa timur, and The method of dan metode polymerization for getting polyaniline. Composite of PANi/SiO2 is mixed in the paint with concentration comparison composite of PANi/SiO2 i.e. 97.5::2,5, 90:10, and 85:15. In each of composite is done characterization of sample corrosion test before exposing (its soaked by NaCl 1M). Dust of amorf silica, Dust of polyaniline and composite of PANi/SiO2 are characterized by using FTIR. Steel of SS304 which it has been coated by coating of PANi-SiO2/Paint for knowing The Best corrosion resistance of concentration variation weigth of PANi-SiO2 which it is tested by EIS (Electrochemical Impedance Spectroscopy)The result of EIS test show that at the composition 10% silica-90% PANi is the best corrosion resistor with the value Rp (corrosion resistor) The biggest both before exposing and after exposing, i.e. 3760 Ω and 7370 Ω. Keywords: corrosion, , Electrochemical Impedance Spectroscopy, PANi, SiO2
FABRIKASI BATA RINGAN TIPE CELLULER LIGHTWEIGHT CONCRETE DENGAN BAHAN DASAR PASIR VULKANIK GUNUNG KELUD SEBAGAI PENGGANTI  FLY ASH NOVI SURYANI
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (349.38 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian ini bertujuan untuk mengetahui pengaruh penambahan fly ash pada pembuatan bata ringan dari bahan dasar pasir vulkanik terhadap sifat mekanik bata ringan meliputi kuat tekan, absorbsi air, dan densitas. Fabrikasi bata ringan yang memiliki jenis celluler lightweight concrete dapat dibuat menggunakan metode mixing dengan bahan dasar yaitu pasir, semen, fly ash, dan foam, sebagai sampel pembanding dibuat bata ringan tanpa fly ash pada percobaan kedua. Pada mix design komposisi pembuatan bata ringan pemakaian foam agent dikontrol sebanyak 40%Wt pada seluruh sampel bata ringan. Sehingga didapatkan nilai densitas bata ringan tanpa fly ash sebesar 1851 kg/m3, Pada bata ringan dengan campuran fly ash densitas minimum yang diperoleh 472 kg/m3. Nilai absorbsi pada bata ringan tanpa fly ash sebesar 24.27% dan pada bata dengan fly ash sebesar 22%, nilai kuat tekan yang diperoleh pada bata ringan tanpa fly ash sebesar 15.42 MPa sedangkan pada bata ringan dengan fly ash sebesar 9.79MPa. Nilai konduktivitas termal pada sampel bata ringan tanpa fly ash diperoleh 5.1 W/mK sedangkan pada bata dengan fly ash 6.6 W/mK. Sifat mekanik ini dipengaruhi oleh komposisi penyusun batu bata, dengan keberadaan fly ash bata ringan memiliki banyak pori-pori pada permukaan dalam maupun luar yang berakibat air mudah merembes dan rapuh namun nilai densitas yang dimiliki lebih kecil jika dibandingkan bata ringan tanpa fly ash. Kata kunci : Fly ash, Pasir vulkanik, Foam, dan Bata ringan. Abstract The Purposes of this research are to discover fly ash effect in developing lightweight using Kelud mountain volcanic sand to find mechanical properties which are compressive strength, water adsorption and the density. Lightweight concrete type cellular lightweight concrete can be made using mixing method with basic material are sands, cement, fly ash, and foam, for the comparator we made the lightweight without fly ash. In mix design, the compositions of foam agent are controlled by 40%Wt of all samples. So we get density value of lightweight concrete without fly ash is 1851 kg/m3. In lightweight concrete with fly ash we get the density of lightweight is 472 kg/m3. The adsorption value of lightweight concrete without fly ash is 24.27% and the adsorption value of lightweight concrete with fly ash is 22%, the compressive strength of lightweight concrete without fly ash is 15.42 MPa and the compressive strength of lightweight concrete with fly ash is 9.79 MPa. The value of thermal conductivity of lightweight concrete sample without fly ash is 5.1 W/mK and the value of thermal conductivity of lightweight sample with fly ash is 6.6 W/mK. This mechanic properties affected by the composition of lightweight concrete, lightweight concrete with fly ash has many pores that affected to water adsorption and the lightweight concrete is strength less, but the density is smaller than lightweight concrete without fly ash. Keywords: Fly ash, volcanic sand, foam, lightweight concrete.
RANCANG BANGUN BANDUL BALISTIK MENGGUNAKAN HUKUM KEKEKALAN MOMENTUM PADA TUMBUKAN TIDAK ELASTIS ABDUR ROHMAN
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (626.405 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Penelitian ini bertujuan merancang aparatus bandul balistik sebagai hukum kekekalan momentum yang berbasis mikrokontroler, dikarenakan bandul balistik (ballistic pendulum ME-6830, Pasco) pada Laboratorium eksperimen masih tergolong manual yaitu dengan menggunakan data berupa nilai sudut yang dibaca langsung oleh praktikum. Pada penelitian bandul balistik ini menghasilkan data digital yang diperoleh melalui perekaman dua sensor yaitu sensor rotary encoder dan sensor photodioda. Nilai momentum dan kecepatan sistem sesaat setelah tumbukan diperoleh ketika peluru ditembakkan terhadap bandul dengan membaca sudut simpang vertikal oleh sensor rotary encoder. Sedangkan sensor photodioda yang berfungsi untuk menentukan kecepatan peluru sesaat sebelum tumbukan dan diperoleh nilai momentum sebelum tumbukan. Pengambilan data dilakukan dengan memanipulasi massa bandul, dan diulang sebanyak sepuluh kali. Momentum sesaat setelah tumbukan yang diperoleh dari bandul balistik mempunyai nilai error rata-rata 2,107% terhadap nilai momentum sesaat sebelum tumbukan. Berdasarkan hasil pengukuran tersebut dapat disimpulkan bahwa penelitian ini mendekati keberlakuan hukum kekekalan momentum. Sedangkan nilai kecepatan sistem sesaat setelah tumbukan berbanding terbalik dengan penambahan massa bandul. Kata kunci : Momentum, kecepatan, rotary encoder, photogate, dan photodiode. Abstract The purposes of this research are to develop ballistic pendulum using momentum conservation law in non-elastic conservation with microcontroller, it cause by ballistic pendulum (ballistic pendulum ME-6830, Pasco) in experiment laboratory is simple, the angle of the ballistic pendulum manually determined by looking at the arc. In this research the digital data obtained from rotary encoder and photodiode sensors. The value of momentum and velocity shortly after the bullet released from projectile launcher the angles determined by digital data from the arc. The functions of photodiode sensors are to determine the bullet velocity shortly before collision. Data obtained by manipulation of pendulum mass, and repeated by ten times. Momentum shortly after collision obtained from ballistic pendulum with error 2,107% to the momentum value shortly after collision. Conclude, from that collected data this research is approaching capability with momentum conservation law. But, the system velocity shortly after collision are opposite with the mass increment. Keywords: Momentum, velocity, rotary encoder, photogate, photodiode.
Studi tentang SUDUT AZIMUT STASIUN dan hubungannya DENGAN DURASI RUPTURE GEMPA BUMI Pada masing-masing stasiun DONY KURNIAWAN
Inovasi Fisika Indonesia Vol 4 No 3 (2015)
Publisher : Jurusan Fisika FMIPA Universitas Negeri Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (770.886 KB) | DOI: 10.26740/ifi.v4n3.p%p

Abstract

Abstrak Pulau Jawa merupakan pusat perekonomian dan perindustrian di Indonesia dan termasuk daerah rawan terhadap bencana gempa bumi dikarenakan Jawa dilalui oleh jalur pertemuan 2 lempeng tektonik. Untuk mengurangi dampak bencana gempa bumi dipulau Jawa, maka dilakukan penelitian yang bertujuan menentukan korelasi sudut azimut stasiun dan durasi rupture (Tdur) untuk gempa bumi di wilayah Jawa serta menetukan nilai L/Vr dan L/Vapp. Penelitian ini menggunakan data gempa bumi di wilayah Jawa dengan 4 Event yang diperoleh dari wilber IRIS. Sudut azimut stasiun diperoleh dari wilber IRIS dan nilai durasi rupture diperoleh dari software Jokotingkir, sehingga dapat diketahui grafik hubungan antara sudut azimut stasiun dan durasi rupture untuk gempa bumi di wilayah Jawa. Hasil dari penelitian ini didapatkanpersamaan empiris regresiumum antara sudut azimut stasiun dan durasi rupture pada masing-masing stasiun yaitu, . Berdasarkan persamaan empiris regresi yang diperoleh maka didapatkan persamaan empiris regresi pada tahun 2011 sampai 2014 yaitu, tahun 2011: , tahun 2012: , tahun 2013: , dan tahun 2014: . Korelasi antara sudut azimut stasiun dan durasi rupture gempa bumi di Jawa dengan nilai ketepatan R-Square tahun 2011 = 76,97%, 2012 = 67,45%, 2013 = 70,22%, dan 2014 = 83,27%, serta R tahun 2011 = 87,73%, 2012 = 82,12%, 2013 = 83,80%, dan 2014 = 91,25%. Pada gempa tahun 2011: L/ = 64 dan L/ = 55,5; tahun 2012: L/ = 64,1 dan L/ = 72,2; tahun 2013: L/ = 55,3 dan L/ = 51,4; dan tahun 2014: L/ =98,3 dan L/ = 99,1 Kata kunci :Gempa bumi , Tdur, Sudut Azimut, R-Square Abstract Java Island is the center of industrial and economic activity in Indonesia, it passed by two tectonics slab that can cause an earthquake. To reduce the impact of the earthquake in java, then is very important to do a research with the purposes are to determine correlation between azimuth station and rupture duration (Tdur) in java island, in this research also to determine L/Vr value and L/Vapp value. This research used earthquake data in java island with 4 events that can take from Wilber IRIS website. Azimuth station get from Wilber IRIS website and rupture duration get from Jokotingkir software, from that data, graph between azimuth station and rupture duration can be obtained for java island. Finally, this research get empiric regression equation between azimuth station and rupture duration in each station are, From that empiric regression equation, the empiric regression equation from 2011 until 2014 are, in 2011: , in 2012: , in 2013: , and in 2014: . Correlation between azimuth station and rupture duration of earthquake in java island with R-square value in 2011 = 76,97%, 2012 = 67,45%, 2013 = 70,22%, and 2014 = 83,27%, also R in 2011 = 87,73%, 2012 = 82,12%, 2013 = 83,80%, and 2014 = 91,25%. In theearthquakeof 2011: L/ = 64 and L/ = 55,5; in 2012: L/ = 64,1 and L/ = 72,2; in 2013: L/ = 55,3 and L/ = 51,4; and in 2014: L/ =98,3 and L/ = 99,1 Keywords: earthquake, Tdur, Azimuth station, R-square.

Page 10 of 42 | Total Record : 415