Telecommunications, Computers, and Electricals Engineering Journal
ISSN : -     EISSN : 30260744     DOI : https://dx.doi.org/10.26418/telectrical.v1i2
Signal Processing; Communication Networks; Artificial Intelligence, Computer Technology; Power Systems; Image Processing
Articles 68 Documents
TRAFO OIL FAILURE BASED ON DISSOLVED GAS ANALYSIS AND VOLTAGE BREAKDOWN RESULTS Fauji, Ahmad; Kurnianto, Rudi; Rajagukguk, Managam
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69800

Abstract

Contamination on the transformer oil can lead to the oil failure of the transformator. Therefore, the transformer oil needs to be tested to make sure the oil is still in good condition. To find indications of oil failure the transformator needs to be tested DGA and BDV. From the results of the analysis with the TDCG method, the gas content in the transformer oil is less than 720 ppm so according to the IEEE standard, the oil transformer is indicated in normal conditions. In the Key Gas method, the percentage of the dominant carbon monoxide gas content is in the range of 85-90% so it is indicated that heating occurs on paper insulation. In the Duval Triangle method, the cut point between methane gas, ethylene and acetylene is in zone 1 and zone 2 so indicated that the oil of the transformator has thermal interference. In the BDV test, the transformer oil resistance values of 40.43 kV and 38.98 kV were obtained according to the IEC oil standard indicated in normal conditions. Of the four methods used to analyze the condition of the oil transformers concluded the oil of the transformers in a good condition but indicated heating.
BIQUAD ANTENNA DESIGN WITH CIRCLE REFLECTORS Pratama, Nanta Aprilian; Marpaung, Jannus; Suryadi, Dedy
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 2: October 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i2.70022

Abstract

This research is about how to develop a signal receiving antenna using cans as a reflector and copper wire in the form of BiQuad as a drive. With the experimental method directly to the research site which is useful for analyzing each captured signal strength. One of the objectives of this research is to support the improvement of the creative economy in Sungai Kupah Village, where the area really needs help from signal strength. The results of this study indicate that using only a can antenna can improve the GSM signal quality. There are 2 providers used, namely Tri and Telkomsel by taking variable values from Signal Strength, RSSI, SINR, RSRP, RSRQ, Ping, Upload, Download and taking the daily data for 5 research days in the morning and evening which aims to analyze any change in the value of the variable data. The average value obtained by the Tri provider for 5 days in the morning at Signal Strength -113.4 dBm, RSSI -82.64 dBm, SINR 4.78 dB, RSRP -113.4 dBm, RSRQ -13.2 dB , Ping 168.21 ms, Upload 37.68 Mbps, Download 2.08 Mbps. The average value obtained by the Tri provider for 5 days in the afternoon at Signal Strength -112.8 dBm, RSSI -82.36 dBm, SINR 4.56 dB, RSRP -112.8 dBm, RSRQ 13.3 dB, Ping 194.60 ms, Upload 20.52 Mbps, Download 9.15 Mbps. The average Telkomsel provider gets for 5 days in the morning at Signal Strength -115.8 dBm, RSSI -87.16 dBm, SINR 4.56 dB, RSRP -115.8 dBm, RSRQ -10.3 dB, Ping 189.14 ms, Upload 23.52 Mbps, Download 15.67 Mbps. The average Telkomsel provider gets for 5 days in the afternoon at Signal Strength -113.8 dBm, RSSI -86.12 dBm, SINR 6.16 dB, RSRP -113.8 dBm, RSRQ -9.7 dB, Ping 157.52 ms, Upload 31.83 Mbps, Download 22.27 Mbps.
IDENTIFICATION OF ELECTROMAGNETIC FIELDS RADIATION INTENSITY ON MEDIUM VOLTAGE NETWORK EQUIPMENT Siregar, Niko; Kurnianto, Rudi; Imansyah, Fitri; Yacoub, Redi; Kusumawardhani, Eka
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69919

Abstract

This research is about how to identify electromagnetic fields radiation intensity with measuring the electric fields and magnetic fields then compare it to the radiation exposure standards for public from ICNIRP. With the experimental method directly to the 15 randomize research sites in Pontianak city, each measurement   on 1 site done on 4 sides, front, back, right and left of the objects and each sides done measurement 5 times on different distance from 1 "“ 5 m.   The objects that has been measured are Transformer, which is very high value of electromagnetic fields compare it to any other medium voltage network equipment. The results still so much lower value than the exposure standards for public, but according to Anies reference there will be some effects about this if the public been exposed to radiation for too long, there are psychological and physicalogical effects. Hopefully this research could be referred to the public to consider the dangers exposed to radiation exposure of electromagnetic fields by medium voltage network equipment.
ANALYSIS OF THE EFFECT OF MULTIBAND SECTOR ANTENNA TILTING CHANGES ON LTE NETWORK QUALITY AT SITE XL SUNGAI BUNDUNG MEMPAWAH Azis, Rahman; Imansyah, Fitri; Yacoub, Redi
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 2: October 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i2.70002

Abstract

Based on the facts, the lack of equity in LTE service quality is caused by several factors that exist in the BTS antenna transmission. One area that is still experiencing problems with the lack of network speed and good signal service quality is the Sungai Bundung Laut area of Mempawah Regency. In this study to optimize the transmission of LTE signals in the area, tilting measurements on sectoral antennas are needed. The purpose of this research is to analyze the actual value of tilting changes in the sectoral antenna and analyze the results of LTE signal quality at the mobile station before and after physical tunning and analyze the results of optimization of good and bad levels of LTE signal quality at the mobile station in XL site Sungai Bundung Laut Mempawah Regency. This measurement is done by adjusting the degree angle in 3 antenna sectors using physical tunning and optimization methods. In the physical tunning method, the results obtained in sector 1 are a change in the polarization of the downtilt antenna to Uptilt from 6 ° to 2 °, then a change in the Azimuth angle from 85 º to 120 º. For sector 2 there is a change in Mechanical Downtilt which is changed from 1 ° to 3 °. And in sector 3 there is a change in Electrical tilt which is from 3 ° to 4 °. Whilethe optimization method can change the results of the RSRP signal quality level for the L900 frequency before optimization the overall value is 93.10%, after optimization it becomes 96.16%, from the optimization results there is an increase of 3.05%. For SINR before optimization the overall value amounted to 90.99%, after optimization it became 96.72%, from the optimization results there was an increase of 5.73%. As for changes in RSRP at frequency L1800 before optimization, the overall value amounted to 96.23%, after optimization it became 96.98%, from the optimization results there was an increase of 0.75%. As for SINR before optimization the overall value amounted to 96.99%, after optimization it became 98.02% from the optimization results there was an increase of 1.02%.
ANALYSIS OF WI-FI NETWORK QUALITY IN TANJUNGPURA UNIVERSITY LIBRARY BUILDING Nauvaldi, Syafrizal; Pontia, F. Trias; Tjahjamooniarsih, Neilcy
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69799

Abstract

Tanjungpura University Library Building as a place that is often crowded with students who use Wi-Fi networks, requires good Wi-Fi signal quality to support smooth and efficient internet access to various digital resources.Wi-Fi data retrieval is inside the Tanjungpura University Library Building, Measuring RSSI (Received Signal Strength Indicator) parameters in the Tanjungpura University Library Building area using the application G-NetWi-Fi, where measurements are carried out by the walk test method using the G-NetWi-Fi application, Make data analysis and conclusions from the results of measuring RSSI (Received Signal Strength Indicator) parameters at the Tanjungpura University Library Building.Analysis of the results to be carried out is to analyze measurement data to compare measurement results with RSSI (Received Signal Strength Indicator) quality standards. Based on the measurements made, there are many measurement data that show the quality of RSSI ranging from good, normal and bad, from the Wi-Fi of Tanjungpura University Library on each route. For the RSSI value obtained by each route, the point and time will certainly vary. Measurement results This depends on the route passed by the user from the Tanjungpura University Library Wi-Fi. Because the more users, the greater the RSSI value that will be obtained.
STUDY OF ELECTRICAL INSTALLATION PLANNING AT THE GENERAL HOSPITAL IN BENGKAYANG DISTRICT Prabasa, Restu; Arsyad, M. Iqbal; Pontia W, F. Trias
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69798

Abstract

The Regional General Hospital of Bengkayang Regency is planning the construction of a new building. The Bengkayang Regency General Hospital building will be planned to total 2 buildings, namely the Central Medical building and the IRNA building, where the Central Medical building has 4 floors with an area of 8024.62 m2 and the IRNA building has 3 floors with an area of 5945.55 m2 and several rooms to be built include: INFECTIOUS, IGD, Obstetric Installation, ICU, ICCU, HCU, Operating Room, and IRNA Room. To build the Regional General Hospital of Bengkayang Regency, it is necessary to plan electrical installations which are part of the initial stage of work. In planning this electrical installation, the need for electrical energy to serve the load must be in accordance with the Indonesian National Standard which refers to the Regulation of the Minister of Health of the Republic of Indonesia Number 24 of 2016 concerning technical requirements for hospital buildings and infrastructure and the General Regulation of Electrical Installations (PUIL) 2011. Research on the planning of this installation uses literature study methods and discriminatory analytics. At the planning stage, several calculations were carried out, namely calculating the need for lighting illumination, air conditioning capacity, conducting cross-sectional area, safety current rating, as well as making line diagrams and calculating cost budget details (RAB). Based on calculations and analysis, the amount of power to meet all electricity load needs is 624322 Watt and the total cost of all work is Rp. 5,623,488,000.00.
FTTH NETWORK DISTURBANCE ANALYSIS BASED ON ATTENUATION AND RECEPTION POWER ON THE INDIHOME SINGKAWANG NETWORK Oktariani, Ade; Imansyah, Fitri; Yacoub, Redi Ratiandi
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 2: October 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i2.69902

Abstract

Optical fiber is a transmission medium that allows it to meet human needs to be able to transfer data faster because it uses light as a conductor. There is a damping problem in optical fiber, it needs to be accommodated so as to minimize the occurrence of attenuation in optical fiber. With this research, it can be known the magnitude of the value of a fiber optic transmission attenuation through the method of measuring attenuation values and receiving power at the customer's home   using OPM, identifying fiber optic channel attenuation that affects the quality of internet services, and knowing the comparison of OPM measurement results with OT data reading. This study uses an analytical descriptive approach where the research will describe what it is about a variable that is processed, as well as the symptoms and conditions to be identified. So the results of the study can be obtained, namely, the amount of attenuation measured in the customer's home is influenced by the attenuation measured in ODP. Attenuation at ODP is small with an average optical power value of -18.39 dB, this makes attenuation in customers' homes, namely ONT, tend to be smaller with an average optical power value of -20.04 dB. There is an additional value   of -1.65   dB per transmission. So it is known that the longer the cable used for fiber optic transmission, the greater the attenuation produced so that the optical power emitted by the sender will weaken along with the length of the cable. This is what will affect the quality of internet services.
MONITORING SYSTEM DESIGN OF TRACKING SYSTEM ON SOLAR PANEL FOLLOWING THE SUN ROTATION BASED ON INTERNET OF THINGS Wardhana, Irdza; Priyatman, Hendro; Judiarto, Hilda
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69944

Abstract

In the field of energy, the sun is a large amount of energy and is still little utilized. Solar panels are a tool for utilizing solar energy into electrical energy. The average installation of solar panels is still static/fixed. Static solar panels cause the reception of sunlight energy to be less than optimal. To maximize the energy of sunlight, this solar panel is made dynamic or moved following the direction of sunlight. The monitoring process will be carried out based on the Internet of Things where the parameters to be measured are the value of voltage,current,power,solar panel temperature,and solar irradiation which will appear on the Blynk application via smartphone. Tests were conducted to determine the characteristics of the parameters measured between static solar panels and dynamic solar panels for 7 days. The maximum power value obtained by dynamic solar panels is better than the maximum power obtained by static solar panels, the largest average test value for 7 days from solar panels obtained a power value of 8.54 Watts and on static solar panels obtained a power value of 7.03 Watts. The position of the solar panel towards the sun, environmental conditions,weather conditions affect the value of the measured parameters.
ENERGY AUDIT ON LIGHTING AND AIR CONDITIONING SYSTEMS AT AL-AZHAR ISLAMIC SCHOOL Khabaranus, Yusvian; Purwoharjono, Purwoharjono; Gianto, Rudy
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 1: June 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i1.69827

Abstract

Based on Government Regulation No. 70 of 2009 concerning energy conservation, it is stated that the use of energy by energy sources and users must be carried out sparingly and efficiently. Based on these regulations, this thesis was made with the aim of analyzing opportunities for saving electrical energy in the Islamic Middle School Al-Azhar 17 Pontianak and Islamic High School Al-Azhar 10 Pontianak buildings. Data collection was carried out from December 2022 to January 2023. The results of the analysis obtained 2 recommendations for saving electricity. In the first option, for the lighting system it is done by changing TL lamps to LEDs, requiring 240 LED lamps and for the air conditioning system it is done by changing the refrigerant to Musicool MC-22. Estimated electricity savings of 17%. The payback period is 2 years, 3 months. In the second option, 446 LED lamps were also replaced with TL lamps to LEDs. For the air conditioning system, the AC is replaced with an inverter type. Estimated electricity savings of 61.13%. The payback period is 2 years, 2 months. From the results of this analysis, energy conservation efforts to get electricity savings and cost savings are very feasible in these schools.
STUDY OF HYBRID ELECTRICAL SYSTEM PLANNING IN THE RESEARCH AND COMMUNITY SERVICE INSTITUTE BUILDING Muzakkir, Chaerul; Fitriah, Fitriah; Arsyad, M. Iqbal
Telecommunications, Computers, and Electricals Engineering Journal (TELECTRICAL) Vol 1, No 2: October 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/telectrical.v1i2.70516

Abstract

This research plans a hybrid system in the LPPKM Untan building, comparing the energy and economic aspects of PLN and PLTS using monocrystal type solar panels with a capacity of 320 Wp, and finding the total needs and capacity of solar panels, batteries, SCC, inverters, and ATS. In the LPPKM building with an installed electrical power capacity of 23 kVA with a hybrid system will compare PLN and PLTS energy by 50% and 30% of the maximum daily power of 11.5 kW. Energy and economic analysis found that the most efficient PLTS energy cost to use, meeting and even exceeding the daily and monthly use of electric power in the LPPKM building is PLTS with a capacity of 50% (10,857.28 kWp / year) with cost savings of Rp. 15,486,877 kWp / year with a very high LCC value compared to using a capacity of 30% of the maximum power even though the LCC is low. The feasibility of investment made by the 50% capacity PLTS shows an NPV value of Rp. 28,394,341, -. PI = 1.16 and DPP value of 17 years. Indicating that the construction of PLTS in LPPKM is feasible by using a PLTS capacity of 50%.