Claim Missing Document
Check
Articles

Found 22 Documents
Search

Pengaruh Bahan Pengisi Cangkang Kelapa Sawit Komposit-Silicone Rubber Dalam Permulaan Pemohonan Listrik Fitriah, Fitriah; Kurnianto, Rudi; Rajagukguk, Managam
ELKHA : Jurnal Teknik Elektro Vol. 12 No. 2 October 2020
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v12i2.40941

Abstract

Inception of electrical treeing  can irreversibly deteriorate the insulation of polymeric power cables leading to a complete failure and initial process of degradation in polymer insulation due to a void that experiences high electric field stress in the material. This paper present will study filler’s influence on inception of electrical treeing growth in silicone rubber – oil palm endokaprium composite.  The observed data is inception voltage and time phenomena in two types of test sample, that is " with filler " and " without filler ". Sample of filler consisted of silicone rubber and oil palm endokaprium composite for oil palm endokaprium weight is 0.1 grams and weight silicone rubber 3.9 gram. While the sample without filler is only silicone rubber . It is obtained that the tree inception voltages dan time for “with” dan “without filler” specimens are 8 kV / 182 seconds and 7,5 kV / 137 seconds, respectivelly.. It is considered that “filler”  acted as a barrier for tree inception. We throught that “filler” enhanced dielectric strength of silicone rubber and oil palm endokaprium by disturbing high electric field stress, result in higher tree inception voltage and longer tree inception time.
Reliability Evaluation of Kumpai Feeder Distribution System at PT. PLN (Persero) ULP Siantan Kurniawan, Ari Kurniawan; Fitriah, Fitriah; Arsyad, M. Iqbal
ELKHA : Jurnal Teknik Elektro Vol. 13 No. 2 October 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v13i2.48660

Abstract

The research on reliability index of a feeder aims to evaluate the reliability level of a feeder using the Reliability Index Assessment (RIA) method. This method evaluates the reliability of a 20 kV distribution network by calculating the reliability indexes of each load point. The evaluation results show the reliability index value per section of the Kumpai Feeder at PT. PLN (Persero) ULP Siantan within one year. The SAIFI values are 0.0092; 0.0012; 12,477; 0.0596; 0.0204; 0.0470; 0.0155; 0.0728, the SAIDI values are 0.0277; 0.0042; 37,746; 0.1862; 0.0741; 0.1524; 0.0493; 0.2209, the CAIDI values are 3.0108; 3.5; 3,025; 3.1241; 3.6323; 3.2425; 3.1806; 3.0343, the MAIFI values are 0; 5,480; 0.2145; 0.0020; 0.0038; 0.0042; 0.0006; 0.0014. The calculation results show that the 20 kV distribution system at PT. PLN (Persero) ULP Siantan at the Kumpai Feeder can be categorized as unreliable. Because the SAIFI value of this feeder exceeds the standard set by PT. PLN (Persero) which are 12.477 times/customer/year and 3.2 times/customer/year, respectively. The factors affecting the reliability index of the Kumpai feeder are the number and duration of blackouts, the number of customers, and the length of the distribution system channel.
Rancang Bangun Aplikasi Perencanaan Instalasi Penerangan Berbasis Sistem Pakar Sirait, Alen Gonzales; Sirait, Bonar; -, Fitriah
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2021): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sistem penerangan menjadi salah satu fasilitas pendukung sebuah bangunan. Penerangan yang baik dapat ditentukan berdasarkan pada peraturan dan ketentuan sesuai dengan standar bangunan yang dipilih. Di dalam proses perhitungan manual akan memakan waktu yang panjang, sehingga di dalam penelitian ini akan merancang dan membuat sistem aplikasi perencanaan perhitungan instalasi listrik penerangan dengan menggunakan sistem pakar agar perhitungan menjadi tepat dan akurat. Pembuatan aplikasi ini menggunakan Microsoft Office Excel dengan (sheet to sheet dan hyperlink). Dalam merencanakan sistem pakar ini menggunakan metode studi literatur, observasi, dan deskriptif analitis. Pada tahap perencanaannya dilakukan beberapa perhitungan yaitu menghitung dengan sistem manual dan sistem pakar, intensitas penerangan, daya total, dan besar arus pengaman MCB. Sistem aplikasi ini hanya menggunakan 3 buah jenis lampu yaitu lampu TL, lampu LED Philips, dan lampu LED Hannochs. Perhitungan dilakukan dengan membandingkan hasil sistem manual dan sistem pakar. Berdasarkan hasil perhitungan jumlah lampu menggunakan perhitungan manual maupun menggunakan aplikasi sistem pakar dari hasil tersebut didapat besar rata-rata persentase error adalah 0,02%, untuk perhitungan daya total dan perhitungan besar arus pengaman didapat persentase error sebesar 0,00%. Aplikasi sistem pakar ini sangat membantu dan mempermudah dalam perhitungan sistem penerangan  instalasi listrik seperti intensitas penerangan, daya total dan besar arus pengaman, sehingga adanya aplikasi sistem pakar ini dapat menghemat waktu dalam penyelesaian suatu masalah yang kompleks dan solusi untuk mempersingkat perhitungan yang rumit dapat terpecahkan.
PENERAPAN DEMAND SIDE MANAGEMENT PADA HOTEL KAPUAS PALACE PONTIANAK Hermanto, Bambang; Sirait, Bonar; -, Fitriah
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2021): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Salah satu metode yang sekarang dipakai untuk mengefisienkan pemakaian energi listrik adalah dengan metode DSM yang akan menghasilkan strategi yang akan memberikan peluang penghematan biaya listrik pada saat tingkat hunian meningkat. Pada penelitian ini dipilih dua strategi metode Demand Side Management (DSM) yaitu peak clipping dan load shifting untuk menurunkan beban puncak di sektor Gedung Hotel Kapuas place Pontianak  yang difokuskan pada beban lampu penerangan, AC, pompa, dan water heater. Dari hasil penelitian pada kondisi eksisting beban puncak yang terjadi pada Hotel Kapuas Palace Pontianak sebesar 163,71 kW dan beban rata-rata sebesar 124,90 kW, serta faktor beban sebesar 0,76. Pemakaian energi listrik per tahun sebesar Rp.1.094.127,65 dan total biaya per tahun sebesar Rp.1.223.711.560,00. Pemakaian energi listrik per tahun dengan menerapkan strategi Peak Clipping sebesar Rp.1.027.566,25 dan total biaya per tahun sebesar Rp.1.147.233.639,54. Penerapkan Demand Side Management dengan strategi Peak Clipping pada Hotel Kapuas Palace Pontianak dapat menghasilkan penghematan biaya sebesar 6,25%. Penerapkan strategi Load Shifting  memperoleh beban puncak sebesar 147,04 kW dan beban rata-rata sebesar 124,90 kW, serta faktor beban sebesar 0,85. Pemakaian energi listrik per tahun dengan menerapkan strategi Load Shifting sebesar Rp.1.094.127,65 dan total biaya per tahun sebesar Rp.1.214.502.785,96. Penerapkan Demand Side Management dengan strategi Load Shifting pada Hotel Kapuas Palace Pontianak dapat menghasilkan penghematan biaya sebesar 0,75%.
Photovoltaic parameters estimation of poly-crystalline and mono-crystalline modules using an improved population dynamic differential evolution algorithm Ayong Hiendro; Ismail Yusuf; Fitriah Husin; Kho Hie Khwee
International Journal of Electrical and Computer Engineering (IJECE) Vol 12, No 5: October 2022
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/ijece.v12i5.pp4538-4548

Abstract

Photovoltaic (PV) parameters estimation from the experimental current and voltage data of PV modules is vital for monitoring and evaluating the performance of PV power generation systems. Moreover, the PV parameters can be used to predict current-voltage (I-V) behavior to control the power output of the PV modules. This paper aimed to propose an improved differential evolution (DE) integrated with a dynamic population sizing strategy to estimate the PV module model parameters accurately. This study used two popular PV module technologies, i.e., poly-crystalline and mono-crystalline. The optimized PV parameters were validated with the measured data and compared with other recent meta-heuristic algorithms. The proposed population dynamic differential evolution (PDDE) algorithm demonstrated high accuracy in estimating PV parameters and provided perfect approximations of the measured I-V and power-voltage (P-V) data from real PV modules. The PDDE obtained the best and the mean RMSE value of 2.4251E-03 on the poly-crystalline Photowatt-PWP201, while the best and the mean RMSE value on the mono-crystalline STM6-40/36 was 1.7298E-03. The PDDE algorithm showed outstanding accuracy performance and was competitive with the conventional DE and the existing algorithms in the literature.
Quality Improvement of 20 KV Voltage Profile Of PT. PLN (Persero) Ketapang According to SPLN No.72 Of 1987 Fitriah Husin; Bonar Sirait
ELKHA : Jurnal Teknik Elektro Vol. 14 No. 1 April 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/elkha.v14i1.48511

Abstract

This study aims to determine the magnitude of the increase in the voltage profile of the 20.kV distribution network system of PT. PLN (Persero) Ketapang with the installation of reactive power injection equipment. The research method used is the Newton Raphson power flow method with MATLAB simulation program. From the results of these calculations, Pawan 2 and Pawan 6 load buses each have a voltage drop above 5%, which is found on 42 buses. To overcome this, reactive power injection (Qc) was carried out: 150 KVAR on bus 26 of Pawan 2, and 900 KVAR on bus 40 and 46, and 600 KVAR on bus 51 of Pawan 6. This leads to the increase in voltage drop percentage on Pawan 2 and Pawan 6, thus, the profile meets SPLN No. 72 of 1987, which is below 5%.
ANALISA PERHITUNGAN DISTRIBUSI TEGANGAN DAN ARUS BOCOR PADA ISOLATOR RANTAI Vanisa Gustiana; Bonar Sirait; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 9, No 2: Juli 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v9i2.49158

Abstract

Penelitian ini melakukan perhitungan distribusi tegangan dan arus bocor serta efisiensi pada isolator rantai dengan melakukan penambahan isolator sebanyak 4,5,6 dan 7 buah pada isolator rantai. Mengingat sedikitnya tulisan yang berhubungan dengan distribusi tegangan pada isolator rantai ini, maka menjadi alasan untuk membahas mengenai masalah ini. Perhitungannya menggunakan metode Eliminasi Gauss berdasarkan pendekatan hukum Kirchoff dengan menggunakan program Matlab. Adapun hasil simulasi perhitungan yang dilakukan pada tegangan 150 kV, 275 kV, 500 kV dan 1000 kV menggunakan 4, 5 dan 6 isolator dengan efisiensi  pada variasi tinggi sebesar  132.43% , 183.73 % dan 439.38 % dan variasi rendah 141.71%, 221.69 % dan 1589 %. Arus bocor yang dihasilkan juga tidak lebih dari 1 kA dimana nilai ini relatif kecil dan masih bisa ditoleransi. Efisiensi yang dihasilkan 7 isolator bernilai negatif dimana hasil efisiensi untuk variasi tinggi sebesar -384 % dan variasi rendah -181 %. Berdasarkan analisa hasil perhitungan distribusi tegangan yang menggunakan variasi tinggi dan rendah nilainya baik apabila jumlah isolator yang digunakan tidak lebih dari 6 isolator, hal ini dipengaruhi dari nilai kapasitansi dan jumlah isolator yang digunakan. Selama hasil efisiensi isolator lebih dari 100 % maka isolator yang digunakan baik dan begitu juga sebaliknya. Pada transmisi tegangan tinggi nilai kapasitansi dipengaruhi oleh besar isolator, jarak antar isolator, dan jarak konduktor dengan klem isolator.
ANALISIS AUDIT ENERGI SISTEM PENCAHYAAN DAN TATA UDARA DI UNIVERSITAS MUHAMMADIYAH PONTIANAK Muhammad Muchlis Ansor; Purwoharjono -; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 10, No 1: Januari 2022
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v10i1.52046

Abstract

Profil pemakaian energi listrik memberikan gambaran tentang distribusi pemakaian energi dan intensitas konsumsi energi. Tujuan penelitian ini untuk mengetahui besarnya nilai Intensitas Konsumsi Energi (IKE) dan Peluang Hemat Energi (PHE) pada Gedung Teori Bersama Universitas Muhammadiyah Pontianak dan merekomendasikan penghematan energi listrik. Metode penelitian yang digunakan yaitu studi literatur, observasi, metode analisis deskriptif dengan perhitungan yang dibantu oleh Microsoft Excel. Nilai IKE pada tahun 2018 sebesar 90,30 kWh/m2 per tahun, tahun 2019 sebesar 112,49 kWh/m2 per tahun saat kondisi sebelum pandemi covid-19 dan tahun 2020 sampai bulan Agustus tahun 2021 saat pandemi covid-19 sebesar 134,15 kWh/m2 per tahun,. Berdasarkan standar IKE yang ditetapkan yaitu 240 kWh/m2 per tahun, nilai IKE masih tergolong efisien dan total Peluang Hemat Energi (PHE) pada tahun 2018 sebelum pandemi covid-19 sebesar 116,544 kWh, dan total PHE pada tahun 2019 sebelum pandemi covid-19 sebesar 64,48 kWh, total PHE pada tahun 2020 sampai bulan Agustus tahun 2021 saat pandemi covid-19 sebesar 143,136 kWh. Pada total konsumsi energi listrik yang didapat masih bisa menekan nilai IKE dengan cara melakukan penggantian lampu CFL (SL) ke lampu LED untuk sistem pencahayaan dan penggantian Refrigerant HCFC R-22 dengan menggunakan Refrigerant Musicool MC-22 untuk sistem tata udara AC. Penggantian tersebut dapat menghasilkan sebuah perbandingan dan penurunan konsumsi energi listrik pada gedung teori bersama Universitas Muhammadiyah Pontianak.
PERHITUNGAN INDEKS KEANDALAN PADA JARINGAN DISTRIBUSI 20 KV DI PT PLN (PERSERO) ULP RASAU JAYA Tiya Nurul Lestari; M. Iqbal Arsyad; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 11, No 1: Januari 2023
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v11i1.62009

Abstract

Tenaga listrik merupakan komponen penting dalam kehidupan masyarakat untuk memenuhi berbagai kebutuhan serta dalam rangka peningkatan kualitas hidup masyarakat. Faktor keandalan juga perlu menjadi perhatian dalam mengoperasikan sistem jaringan distribusi. Indeks-indeks keandalan yang sering digunakan dalam suatu sistem distribusi adalah SAIFI (System Average Interruption Frequency Index), SAIDI (System Average Interruption Duration Index), CAIDI (Costumer Average Interruption Duration Index), CAIFI (Costumer Average Interruption Frequency Index), dan MAIFI (Momentary Average Interruption Frequency Index). Tujuan penelitian ini untuk menentukan indeks dan perbandingan nilai keandalan dengan menggunakan metode FMEA dan RIA SPLN 68-2 : 1986 dan IEEE std 1366 – 2003. Dalam penelitian ini data diambil dari tahun 2018 sampai 2021 di PT PLN (Persero) ULP Rasau Jaya menggunakan 2 metode yaitu metode RIA untuk menghitung laju kegagalan, lama gangguan, MTTR, MTTF, MTBF dan indeks keandalan. Metode FMEA untuk menghitung MTTR, MTTF, laju kegagalan, laju perbaikan dan indeks keandalan. Hasil akhir penelitian ini menunjukan bahwa nilai indeks keandalan yang memenuhi standar terdapat pada tahun 2018 sebesar 0,3003 kali/tahun, tahun 2020 sebesar 0,1437 kali/tahun, tahun 2021 sebesar 0,016 kali/tahun dan yang tidak memenuhi standar terdapat pada tahun 2019 sebesar 11,6915 kali/tahun untuk metode FMEA dan untuk metode RIA tidak ada yang memenuhi standar atau hasil dari perhitungan melebihi standar yang digunakan. Dari hasil penelitian dapat disimpulkan bahwa metode FMEA merupakan metode yang memenuhi standar dan metode RIA merupakan metode yang tidak memenuhi standar.
EVALUASI BESAR PENGHEMATAN BIAYA RUGI-RUGI ENERGI TOTAL AKIBAT PENGATURAN PEMAKAIAN DAYA PADA GARDU DISTRIBUSI BRAVOE ROLLY MORRISON SINAGA; Bonar Sirait; Fitriah -
Journal of Electrical Engineering, Energy, and Information Technology (J3EIT) Vol 9, No 2: Juli 2021
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26418/j3eit.v9i2.49872

Abstract

Penelitian ini dilakukan untuk menentukan besar penghematan biaya rugi-rugi energi total (kWh) gardu distribusi pada konsumen yaitu ,industri,domestik dan komersil pada GI Siantan. Analisis rugi-rugi energi yang terjadi pada JTM memerlukan persiapan data kWh produksi, data beban rata-rata dan beban puncak penyulang tersebut, Metode yang digunakan pada penelitian ini menggunakan Demand Side Management (DSM) dengan strategi Load Shifting dan Peak Clipping. Dari hasil penelitian dan perhitungan yang telah dilakukan pada simulasi penerapan DSM pada GI Siantan menggunakan 3 skenario yaitu skenario pertama membuat 13 pengatur beban yang masing-masing bernilai 1000 kW, skenario kedua membuat 13 pengatur beban yang masing-masing bernilai 2000 kW, dan skenario ketiga membuat 8 pengatur beban yang masing-masing bernilai 1500 kW. Berdasarkan hasil yang didapat disimpulkan bahwa penerapan DSM yang telah dilakukan tidak terjadi perubahan energi maksimum (beban total) yang digunakan karena metode yang digunakan adalah Load Shifting, yang artinya beban hanya dipindahkan jadwal operasional dari Waktu Beban Puncak (WBP) ke Luar Waktu Beban Puncak (LWBP). Penerapan DSM dengan metode Peak Clipping menghasilkan penghematan terbesar pada skenario 1 yaitu sebesar 12.192401% karena skenario 1 memiliki nilai beban puncak yang terkecil