cover
Contact Name
Arga
Contact Email
arga.arga.mpd@gmail.com
Phone
+6285396188384
Journal Mail Official
arga.arga.mpd@gmail.com
Editorial Address
BTN Moncongloe Mas Blok D3 No 14
Location
Kota makassar,
Sulawesi selatan
INDONESIA
Jurnal Pendidikan Kepelatihan Olahraga: Pejuang
ISSN : -     EISSN : 30901278     DOI : -
Core Subject : Health, Education,
JURNAL PENDIDIKAN KEPELATIHAN OLAHRAGA (PEJUANG): adalah sistem jurnal terbuka yang menggunakan sistem peer-review untuk jurnal yang dikirimkan JURNAL PENDIDIKAN KEPELATIHAN OLAHRAGA (PEJUANG) diterbitkan oleh Prodi Pendidikan Kepelatihan Olahraga, Universitas Pejuang Republik Indonesia online sejak 2025. JURNAL PENDIDIKAN KEPELATIHAN OLAHRAGA (PEJUANG terbit 3 kali setahun pada bulan Februari, Juni dan Oktober. Menerbitkan hasil penelitian dan hasil pemikiran pada bidang Pendidikan Jasmani, Olahraga Dan Rekreasi, Ilmu Kesehatan Olahraga, Ilmu Kepelatihan Olahraga, Gizi Olahraga dan Fisioterapi.
Arjuna Subject : Umum - Umum
Articles 51 Documents
Concurrent Validity and Reliability of MediaPipe Pose Estimation for Kinematic Analysis of the Clean Lift in Physical Education Students Al-Baitar, Layth Muthanna Ibrahim
Jurnal Pendidikan Kepelatihan Olahraga: PEJUANG Vol. 2 No. 1 (2026): 28 Februari 2026
Publisher : Program Studi Pendidikan Kepelatihan Olahraga

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The aim of this research was to evaluate how well the MediaPipe performs in comparison to Kinovea in analyzing key kinematic parameters in the clean lift movement for physical education students, and how reliable the MediaPipe is in doing so. The research design used in this study was descriptive, combined with both comparative and correlational research approaches. The researchers recruited 30 first-year physical education students at the College of Physical Education and Sports Sciences and conducted an experiment on their clean lift movement, captured by high-speed cameras and analyzed using both the MediaPipe and Kinovea. The data analyzed included the knee, hip, and ankle joint angles, and barbell movement, such as vertical velocity, vertical displacement, and bar path. The data analysis involved the use of descriptive statistics, Pearson correlation, intraclass correlation, root mean square error, paired t-test, and Bland-Altman plots. The findings showed that the MediaPipe and Kinovea are highly comparable, particularly in analyzing the velocity of the barbell, where the correlation coefficient between the two tools was 0.96, showing high concurrent validity. There were no significant differences between the two methods. The reliability of the MediaPipe in analyzing the kinematics of the clean lift movement was high, as the correlation coefficient ranged between 0.85 and 0.91, showing high stability in the measurements. The analysis of the bar path movement showed high comparability between the two methods. The conclusion drawn from the research is that the MediaPipe is an effective and affordable tool for analyzing the kinematics of the clean lift movement and thus can be used in both educational and research settings.