cover
Contact Name
Dina Mariani
Contact Email
dinamariani@unimus.ac.id
Phone
+6285299398663
Journal Mail Official
mediaelektrika@unimus.ac.id
Editorial Address
Universitas Muhammadiyah Semarang FT-FMIPA Building, 7nd Floor. Department of Electrical Engineering Jl. Kedungmundu Raya No. 18, Kota Semarang, Prov. Jawa Tengah, Indonesia 50273 Phone: 085299398663 Email: mediaelektrika@unimus.ac.id
Location
Kota semarang,
Jawa tengah
INDONESIA
MEDIA ELEKTRIKA
ISSN : 19797451     EISSN : 2579972X     DOI : 10.26714/me.14.2.2021.62-75
Media Elektrika is an electrical engineering journal that gives concerns on sciences related to electrical engineering. It includes the following fields: Electrical power engineering Electronics Telecommunication Control Informatics and computer technology
Articles 207 Documents
PEMODELAN DAN SIMULASI FILTER AKTIF SHUNT UNTUK PERBAIKAN HARMONISA SEBAGAI UPAYA PENGHEMATAN ENERGI LISTRIK Luqman Assaffat; Sri Arttini D. P.; M. Haddin -
MEDIA ELEKTRIKA Vol 6, No 1 (2013): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (552.672 KB) | DOI: 10.26714/me.6.1.2013.%p

Abstract

Salah satu metode dalam melakukan penghematan energy adalah dengan memperbaiki kualitas daya listrik. Permasalahan utama dalam kualitas daya listrik adalah permasalahan harmonisa. Harmonisa mempunyai dampak buruk pada sistem tenaga listrik, antara lain terjadinya pemanasan pada trafo, malfungsi peralatan listrik, kesalahan pembacaan pada alat ukur dan kerugian secara finansial. Pengendalian harmonisa pada sistem tenaga dapat dilakukan dengan pemasangan filter harmonisa. Terdapat beberapa jenis filter harmonisa, antara lain filter pasif dan filter aktif. Filter aktif mempunyai kemampuan yang lebih baik dari pada filter pasif karena dapat memperbaiki arus harmonisa sesuai dengan keadaan beban. Pemodelan filter aktif shunt dengan bantuan Matlab/Simulink dan Power System Blocket bertujuan untuk menganalisa berapa besar distorsi harmonisa yang dapat diperbaiki dan besarnya energy listrik yang dapat dihemat. Data simulasi menggunakan data harmonisa pada sistem tenaga listrik Rumah Sakit Panti Wilasa “Citarum” Semarang. Hasil simulasi pemodelan filter aktif shunt menunjukkan bahwa THD Harmonisa arus pada sistem dapat diturunkan sebesar rata-rata 6%. Sedangkan perkiraan energy listrik yang dapat dihemat sebesar 13.692,12 kWH selama satu tahun.
REDUKSI HARMONISA DENGAN FILTER AKTIF SHUNT BERBASIS MATLAB/SIMULINK Dani Nur Prabowo; Muhamad Haddin; Dedi Nugroho
MEDIA ELEKTRIKA Vol 8, No 2 (2015): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (606.882 KB) | DOI: 10.26714/me.8.2.2015.%p

Abstract

ABSTRAK Rumah Sakit Roemani Muhammadiyah Semarang memiliki tingkat pemakaian energi listrik yang membutuhkan kwalitas daya listrik yang baik. Tingginya penggunan beban non linier yang diopeasikan dapat menimbulkan harmonisa yang merupakan permasalahan utama dalam kwalitas daya listrk. Harmonisa memiliki dampak buruk dalam sistem tenaga listrik yang menimbulkan kerugian dalam sistem pelayanan konsumen yang salah satunya diakibatkan terjadinya kesalahan pembacaan dan kerusakaan alat ukur yang digunakan. Untuk Mengatasi masalah ini diguakan filter aktif shunt untuk mereduksi nilai dari harmonisa tersebut. Penelitian ini memfokuskan pada metode reduksi harmonisa dengan menggunakan filter aktif shunt. Prinsip kerja dari filter aktif shunt untuk mengkompensasi harmonisa dengan cara menyuntikan arus harmonisa yang fasanya berbeda 1800. Simulasi filter aktif shunt menggunakan software matlab R2013 yang dibuat berdasrkan teori daya aktif-reaktif sesaat (p-q theory) sebagai penghasil arus refrensi untuk kompensasi harmonisa yang sesuai dengan kondisi beban. Arus refrensi tersebut digunakan sebagai sinyal refrensi pembangkit PWM untuk memicu Inverter yang kemudian membangkitakan arus filter yang diijeksikan pada sistem yang dibuat berdasarkan data yang diambil dari sistem kelistrikan MDP Gedung Lama Rumah Sakit Roemani Muhammadiyah Semarang. Hasil menunjukan bahwa penurunan nilai THD arus 1,4 % pada fasa R, 1,51% untuk fasa S, dan fasa T mencapai 1,37%. . Kata Kunci : Harmonisa, THD, IHD, Filter aktif shunt
RANCANG BANGUN CONVERTER BINARY CODE DECIMAL (BCD) UNTUK MONITORING TAP POSISI INDIKATOR TRAFO PADA SISTEM SCADA PT.PLN (PERSERO) Himawan Himawan; Heri Suryo
MEDIA ELEKTRIKA Vol 11, No 1 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (646.101 KB) | DOI: 10.26714/me.11.1.2018.34-42

Abstract

Converter tegangan BCD ke Desimal 0-3 V adalah sebuah rangkaian elektronika dengan menggunakan mikroprosessor yang dirancang untuk dapat mengubah besaran tegangan BCD menjadi besaran tegangan 0-3 V. Pada Gardu Induk (GI) 150 KV atupun Gardu Induk Tegangan Extra Tinggi (GITET) 500 kV terdapat berbagai macam bay yang diantaranya adalah Bay Line, Bay Trafo, dan Bay Kopel. Khusus pada bay trafo, terkadang salah satu status yang belum terakuisisi dan termonitor pada RCC adalah status posisi tap changer. Pemilihan tap trafo secara otomatis dilakukan dengan suatu peralatan relai AVR. Relai AVR, relai pengatur tegangan adalah peralatan kontrol otomatis pada transformator yang menggerakan motor OLTC. Namun, pada saat tap trafo telah melebihi nilai maksimumnya maka dapat menyebabkan AVR blok. Dengan adanya kondisi seperti ini maka tentunya dapat menyebabkan suatu penyimpangan tegangan yang cukup besar. Tindakan pencegahan yang dilakukan untuk mengatasi AVR blok adalah dengan memonitoring posisi tap pada trafo. Oleh karena itu, dalam penelitian ini dibuat suatu converter sederhana berbasis mikroprosessor untuk mengubah format input tegangan BCD menjadi tegangan 0-3 V.
PERANCANGAN BANK KAPASITOR OTOMATIS SEBAGAI KOMPENSASI BEBAN INDUKTIF DI PT. SIMOPLAS (PABRTK I) Agung Budi Santoso
MEDIA ELEKTRIKA Vol 1, No 1 (2008): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3820.292 KB) | DOI: 10.26714/me.1.1.2008.%p

Abstract

Di dunia industri yang sebagian besar bebannya berupa motor-motor induksi mempunyai pengaruh terhadap sistem kelistrikan PLN secara menyeluruh, dikarenakan motor induksi memiliki faktor daya kurang dari satu.  Dengan faktor daya yang kurang dari satu atau cenderung bersifat lagging (arus tertinggal terhadap tegangan) maka jaringan akan bersifat induktif dengan kata lain nilai rugi-rugi juga akan semakin besar. PLN menerapkan target untuk jaringan minimal faktor dayanya adalah 0,85 lagging. Dengan ketentuan ini maka jaringan dengan faktor daya kurang dari 0,85 lagging akan dikenakan denda oleh PLN. Perancangan bank kapasitor otomatis sebagai kompensasi beban induktif di PT. Simoplas (Pabrik I) merupakan solusi agar perusahaan tidak selalu membayar denda ke PLN dan juga untuk memperbaiki kualitas jaringan listrik agar semakin baik.kata kunci : bank kapasitor, beban induktif, dan koreksi faktor daya
ANALISA KEANDALAN SISTEM TENAGA LISTRIK JAWA TENGAH DAN DIY PERIODE TAHUN 2009-2011 Eri Yawantoro; Bambang Supradono; Achmad Solichan
MEDIA ELEKTRIKA Vol 5, No 1 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (10997.925 KB) | DOI: 10.26714/me.5.1.2012.%p

Abstract

Power Plant units are responsible for providing power generation in the power system so that the load can be served.Poer Plant units may trouble each time. The disorder resulting plants cannot operate. If this interference occurs at the same time on several large generating units, it is possible that the power available in the system is reduced such that the system is not sufficient to serve the load. Reliability cf the electrical system must be maintained and enhanced, so that the load needs to be served. Thus it is necessary to investigate whether or not the reliability of the system every year. Reliability of the electrical system can be determined by calculating the value of (loss of load probability) LOLP with units of days / year. The smaller the value, the better the level of LOLPkendalan an electrical system. In 2009 the electrical system of Central Java and Yogyakarta not meet the standards, ie the value of LOLP 4.088 days / year. For the years 2010 and 2011 has increased reliability and meet the standards, with the value of 0.043 days in 2010 and 0.017 in 2011 days.Keywords: LOLP, reliability of Electric Power Systems
PEMANFAATAN SAMPAH SAYUR PASAR DALAM PRODUKSI LISTRIK MELALUI MICROBIAL FUEL CELLS (UTILIZATION OF MARKET VEGETABLE WASTE IN ELECTRICITY PRODUCTION THROUGH MICROBIAL FUEL CELLS) Muhamad Imaduddin; - Hermawan; - Hadiyanto
MEDIA ELEKTRIKA Vol 7, No 2 (2014): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (495.617 KB) | DOI: 10.26714/me.7.2.2014.%p

Abstract

The presence of organic market vegetable waste is so abundant. One of utilization of vegetable market waste is processed into compost. However, compost has difficulties in marketing so it is only used on a small scale and it gives impact to the environment such as acidification and eutrophication. On the other hand, the threat of energy and fuel-crisis makes activities related to renewable energy into something urgent to be done. One of the renewable energy alternatives is Microbial Fuel Cells (MFCs). MFCs are bioelectrochemical system spontaneously converting biomass into electricity through metabolic activity of microorganisms. The purpose of study is to apply MFCs as an application of voltaic cells in producing electricity using slurry phase of vegetable waste as substrate. Variations performed on the slurry phase comparison: water are 1: 2; 1: 1 and 2: 1, and the addition of EM4. Operations were conducted for 21 days. Production of the greatest voltage is at R1+ reactor (1:2 with addition of EM4) and reached 1180 mV. An electric current is 5.1 μA, and the electric power is 6.02 Mwatt, and the power density is 462.92 mWatt/m2. The presence of water in MFCs role in the mechanism of vegetable waste degradation. The tendency of increase in the electrical energy at the beginning of the operation of the reactor showed an increase in cellular synthesis of microorganisms. Declining electric energy is influenced of pH as microorganisms living place and the formation process of attached media at the electrode. Keywords:  Vegetable Market Waste, Electricity, Microbial Fuel Cells.
EMULASI GERBANG LOGIKA TUNGGAL MULTIFUNGSI MENGGUNAKAN MIKROPENGENDALI ATMEGA8A Arief Hendra Saptadi
MEDIA ELEKTRIKA Vol 10, No 2 (2017): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (400.605 KB) | DOI: 10.26714/me.10.2.2017.%p

Abstract

Gerbang logika merupakan suatu bagian penting dari teknologi digital. Salah satu bentuk implementasi dari gerbang logika tersebut adalah dengan menggunakan IC TTL. Meskipun demikian,penggunaan IC tersebut tidaklah efisien, mengingat bahwa dalam satu seri IC lazimnya terdapat beberapa gerbang yang sama dengan fungsi logika yang tidak dapat diganti sesuai kebutuhan. Tujuan dari penelitian ini adalah membuat model emulasi gerbang logika tunggal multifungsi yang dapat dipilih jenisnya sesuai kebutuhan. Model tersebut direalisasikan menggunakan mikropengendali ATmega8A. Dua buah pin didedikasikan sebagai masukan logika. Sedangkan satu buah pin digunakan sebagai keluaran logika. Sebuah tombol digunakan sebagai pemilih fungsi logika NOT, AND, OR, NAND, NOR, XOR atau XNOR. Tiga buah LED berfungsi sebagai indikator untuk menandai jenisgerbang logika yang dipilih. Berdasarkan hasil pengujian didapatkan hasil bahwa masing-masing fungsi logika untuk NOT, AND, OR, NAND, NOR, XOR dan XNOR dapat diemulasikan dengan baik sesuai tabel kebenaran dari masing-masing gerbang logika. Fungsi pemilihan jenis gerbang logikamelalui tombol dan indikator LED juga sudah dapat berjalan sesuai dengan perencanaan. Model tersebut memungkinkan lebih dari satu mikropengendali untuk dioperasikan dalam satu rangkaian namun dengan fungsi gerbang logika yang berbeda. Pada pengembangan selanjutnya, model ini dapat diperluas menggunakan mikropengendali dengan jumlah pin yang lebih banyak sehingga dapat memuatlebih dari satu gerbang, yang masing-masingnya dapat diatur untuk menjalankan fungsi logika yang berbeda-beda.  Keywords: emulasi, gerbang logika, mikropengendali ATmega8A
STRATEGI MENINGKATKAN KINERJA WEB UNIVERSITAS MUHAMMADIYAH SEMARANG MENUJU PERINGKAT WEBOMETRICS Bambang Supradono
MEDIA ELEKTRIKA Vol 3, No 1 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1322.073 KB) | DOI: 10.26714/me.3.1.2010.%p

Abstract

Nowadays many University competing improve the performance of the network that they have to list in the Webometrics ranking. Semarang Muhammadiyah University (UNIMUS) is actually a University relatively new also trying to enter competition Webometrics ranking of world universities. This study aims to fill the framework of a strategy to achieve the webometria range. The methodology used for the first time to evaluate the performance of the website parameters unimus webometricos and then create a reference point of three national universities that has entered the ranks of the highest ranking of Webometrics, medium and minor at the national level. Later followed by the analysis of webometria evaluation indicators include the size, visibitity, erudite and rich text files. The results were compiled from then action plans in order to set gap of 3 universities in reference. Thus, the benefits can provide guidance for UNIMUS into the Webometrics rangkings. Keywords : UNIMUUS, Webometric
SCANNING DAN RESETTING DISTANCE RELAY PADA PENGHANTAR 150 kV KUDUS ARAH JEKULO Tanzil Ramadhan Aljufri; Bambang Supradono; Luqman Assaffat
MEDIA ELEKTRIKA Vol 4, No 2 (2011): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (282.879 KB) | DOI: 10.26714/me.4.2.2011.%p

Abstract

One unit of P3B Jawa Bali, Central Java and DI Yogyakarta region responsible for operating and maintaining the installation of electric power transmission network in Central Java and Yogyakarta. With the transmission network configuration changes for reasons of consumer needs and for the reliability of the power supply necessary to study the effect of changing the configuration of the coordinated protection system conductor. As happened in the subsystem Kudus-Jekulo-Pati is changing the configuration of the GI Jekulo single phi into a double phi. This change affects the coordination of in the subistem, which overlap in Zone 2 distance in the direction of the GI Kudus-Jekulo to Zone 2 distance relays in GI Jekulo Pati direction, it is known after the scanning process. And to anticipate the problems it is necessary to resetting or setting recalculation distance relay is in the GI Kudus-Jekulo direction, which is expected to resetting, the coordination of protection systems in the susbsistem Kudus-Jekulo-Pati as expected. With better coordination of the protection system conductor protection relay performance became more selective and sustainable electricity distribution maintained the need for electricity can be met in an optimal, effective and efficient. protection systemsKeywords : electric power transmission, protection systems,Distance relay, scanning coordination of protection systems
SISTEM PAKAR KERUSAKAN HARDWARE KOMPUTER DENGAN METODE BACKWARD CHAINING BERBASIS WEB Yenita Wijayana
MEDIA ELEKTRIKA Vol 12, No 2 (2019): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (587.184 KB) | DOI: 10.26714/me.12.2.2019.99-107

Abstract

Computers are a major need to support human performance. Computers also often damage the hardware such as processor, memory, mouse, keyboard, hard disk, optical drive, monitor. Hardware damage is still rarely known by computer users. In this final project aims to build a knowledge-based system to diagnose damage to computer hardware or hardware in the form of websites using PHP using the waterfall model and the backward chaining method. Making a Computer Damage Expert System with Web-Based Backward Chaining Method is expected to be able to help computer users to solve problems on computer hardware, so users can save on technician costs and can save time.

Page 8 of 21 | Total Record : 207