cover
Contact Name
Dina Mariani
Contact Email
dinamariani@unimus.ac.id
Phone
+6285299398663
Journal Mail Official
mediaelektrika@unimus.ac.id
Editorial Address
Universitas Muhammadiyah Semarang FT-FMIPA Building, 7nd Floor. Department of Electrical Engineering Jl. Kedungmundu Raya No. 18, Kota Semarang, Prov. Jawa Tengah, Indonesia 50273 Phone: 085299398663 Email: mediaelektrika@unimus.ac.id
Location
Kota semarang,
Jawa tengah
INDONESIA
MEDIA ELEKTRIKA
ISSN : 19797451     EISSN : 2579972X     DOI : 10.26714/me.14.2.2021.62-75
Media Elektrika is an electrical engineering journal that gives concerns on sciences related to electrical engineering. It includes the following fields: Electrical power engineering Electronics Telecommunication Control Informatics and computer technology
Articles 207 Documents
TIK SEBAGAI SOLUSI ANAK PECANDU GAME ON-LINE, E-CLASS DAN USULAN MODEL UJIAN AKHIR NASIONAL DALAM SUDUT PANDANG TIK Asih Widi Harini
MEDIA ELEKTRIKA Vol 2, No 2 (2009): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (73.003 KB) | DOI: 10.26714/me.2.2.2009.%p

Abstract

Pemilihan judul diatas tidak hanya relevan dengan konteks kekinian yang ditandai dengan makinbertambahnya korban-korban game on-line terutama di kota-kota besar, tetapi juga terkait dengan upayakita melakukan inovasi pembelajaran khususnya bidang TIK, sehingga pembelajaran menjadi lebihbermakna dan menyenangkan. Selama ini, keberadaan TIK sangat berperan dalam meningkatkan kualitasSDM siswa. Melihat scope TIK yang luas dan terus berkembang, penulis melihat ada kesamaan scope antaraTIK dengan Game on-line, yaitu sama-sama menggunakan komputer. Hanya bedanya, dengan TIK anak bisamenjadiprodusen game, tapi lewat game online, anak hanya sebagai konsumen.Persoalanya adalah ketika Game online sudah tidak lagi berfungsi sebagai media hiburan, tapi lebihke candu bahkan dikomersialkan. Disatu sisi, game online bagus untuk perkembangan otak kanan mereka,namun jika porsinya terlalu besar, kedepannya bisa menghambat karier anak. Jika kompetensi siswa yangdijadikan acuan mutu sistem pendidikan, maka sistem pendidikan yang baik adalah jika inputannyabervariasi tetapi outputannya selalu ‚‘kompeten‘. Artinya sistem pendidikanlah yang mempu menerapi anakpecandu game online. Pengekangan anak, bukanlah solusi , TIK sebenarnya bisa dijadikan altenatif solusimasalah ini. Masalah lain bagi penggemar game online adalah UAN, karena otak kanan cenderung tidakmenyukai keteraturan. Model UAN online, bisa dijadikan alternatif solusi.
PROTOTIPE ALAT PENGUKUR SUHU PANAS (HOT POINT) PADA PERALATAN GARDU INDUK PLN SECARA WIRELESS BERBASIS MIKROKONTROLER ATMEGA 8535 Angger Raharjanto; Bambang Supradono; Aris Kiswanto
MEDIA ELEKTRIKA Vol 6, No 2 (2013): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (135.373 KB) | DOI: 10.26714/me.6.2.2013.%p

Abstract

Lately, the problem of hot point on substation equipment in PLN be an interesting thing to say. Mainly about heat problem which is uncontrolled and unable to be checked continually, this issue deals with the system’s safety and reliability that happens in the substation To overcome this issue, study on the solution which is by making a prototype device to measure real time temperature or hot point continually and by using wireless has been held. This device uses ATMEGA 8535 and heat sensor TPA 81 then it sends the data bay FM signal and later on, this data can be shown and save in computer Using the prototype, the problem that PLN faces these days can be solved, because this prototype device can monitor the hot point change continually and real time
MONITORING PENGAMAN BANGUNAN MENGGUNAKAN SENSOR GERAK BERBASIS MIKROKONTROLLER ATMEGA8535 Samsul; Bambang Supradono; Luqman Assaffat
MEDIA ELEKTRIKA Vol 9, No 1 (2016): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (500.365 KB) | DOI: 10.26714/me.9.1.2016.%p

Abstract

Safety of storeroom is absolutely needed by every company. If there is a safe feeling, the company will not be afraid of. To reduce an afraid, it is designed a device of Monitoring safetystoreroom by using Movement Sensor ATMEGA8535 Microcontroller -based. In this last project, the writer makes that device equipped with PIR sensor which is put in the corner of the storeroom. As its process equipment, it is used ATMEGA8535 microcontroller as program centre. Then, the work method of output appearance as dot matrix, buzzer and bulb lamp is PIR sensor will detecthuman existence or not at the time of storeroom in empty situation. Furthermore, ATMEGA8535 microcontroller sends output signal through dot metric as the direction of storerooms location. After that, buzzer is as alarm and bulb lamp is as indicator lamp. Besides, reset knob is function as system reset when dot matrix, buzzer, and bulb lamp ON. Base on the research data, PIR sensor range is Horizontally about 300-1500 detected. Then, range data of PIR sensor is Vertically with Elevation and Depression which is detected. Furthermore, research data of PIR sensor is based on range 0.5-5.5 meters detected. Key words: Monitoring equipment, PIR KC7783R sensor, ATMEGA8535 microcontroller, dot matrix, buzzer, bulb lamp
PENGEMBANGAN SISTEM INFORMASI AKADEMIK USER FRIENDLY UNTUK SMA MUHAMMADIYAH KOTA TEGAL (SIATA) Luthfi Nur Hidayanti
MEDIA ELEKTRIKA Vol 11, No 2 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (634.979 KB) | DOI: 10.26714/me.11.2.2018.65-74

Abstract

EnglishAn Academic Information System of Senior High School (SMA) is called SIATA. The system is designed and made to make easy on data processing of a school. SIATA is made only for offline web or local host. The method on designing SIATA uses waterfall model, because it is flexible model. SIATA needs an alpha and beta trial testing to find the weakness and quality of the system before it is implemented as the running system. The result of the design is an academic information system, which is easy used by the user. The operating system is not difficult, so it is can be user friendly system. Indonesian Sistem Informasi Akademik SMA Muhata atau yang disebut SIATA, merupakan suatu sistem yang dirancang dan dibangun untuk mempermudah sekolah dalam proses pengolahan data akademik. Saat ini SIATA dibangun sebatas web offline atau localhost. Metode yang digunakan dalam perancangan SIATA ini menggunakan model waterfall karena sifatnya yang fleksibel. Sebelum SIATA diimplementasikan menjadi sistem yang berjalan akan dilakukan pengujian alpha dan pengujian beta guna menemukan kelemahan sistem dan menentukan kualitas sistem. Hasil dari perancangan ini adalah sebuah sistem informasi akademik yang mudah digunakan oleh user dan pengoperasiannya tidak rumit sehingga menjadi sistem yang user friendly.
EVALUASI HASIL MODIFIKASI GENERATOR HMXT-200 PADA SUBSISTEM ELEKTROLIT, FEEDWATER, DAN KONTROL GAS DI PT. INDONESIA POWER TAMBAK LOROK, SEMARANG - Gunawan; Ike Puspa Ningtias
MEDIA ELEKTRIKA Vol 1, No 2 (2008): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (144.996 KB) | DOI: 10.26714/me.1.2.2008.%p

Abstract

Generator HMXT-200 merupakan mesin pembangkit gas hidrogen pada PT. Indonesia Power Tambak Lorok Semarang. Mesin ini menggunakan air (H2O) dengan campuran katalis potassium hydroxide (KOH) untuk menghasilkan hidrogen dengan tekanan 147PSIG. Nantinya gas tersebut akan digunakan sebagai pendingin generator listrik.Antara bulan Mei-Agustus 2008 Generator HMXT-200 mengalami masalah yang menyebabkan mesin tersebut shut down. Dari keseluruhan penyebab shut down alarm, mayoritas yang terjadi adalah Low KOH Level, yaitu kurangnya supply feedwater pada produksi maksimal, mencapai 6% dan Differential Pressure Alarm, yaitu pertidaksamaan pressure oksigen dan hidrogen pada sistem, mencapai 10% kemungkinan. Perbaikan yang dilakukan untuk Low KOH Level dengan menambah relocation tank and regulator, guna menurunkan kapasitas produksi dari 147PSIG menjadi 100PSIG, sehingga supply feedwater tercukupi. Sedangkan pada Differential Pressure Alarm adalah dengan mengubah posisi hydorgen vent, sehingga memperlancar pembuangan hidrogen untuk mengurangi pressurenya.Data yang diambil ulang pada bulan Oktober-Nopember 2008 menunjukkan modifikasi yang telah dilakukan mencapai 50% keberhasilan, dengan menurunkan Low KOH Level menjadi 3% dan Differential Pressure Alarm menjadi 5% kemungkinan terjadi. Peninjauan ulang pada hasil modifikasi dengan memperhatikan penyebab lain kedua alarm, akan memaksimalkan kinerja sistem.
TINGKAT DISTORSI HARMONISA PADA LAMPU ESSENSIAL YANG BERBEDA MERK Luqman Assaffat
MEDIA ELEKTRIKA Vol 5, No 2 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (375.346 KB) | DOI: 10.26714/me.5.2.2012.%p

Abstract

Essential Lamp (SL) is a type of low pressure mercury lamp that works on the discharge ofelectrons inside the tube and using an electronic switch equipment as a replacement ballast forlimiting the current function. Because of the working principle, the essensial lamp can beclassified as a non-linier electrical loadIn the electric power system, a non linear loads will produce an electrical power pollution.It is called harmonics. Harmonics are multiples of the frequency of a fundamental frequency ofwave. Harmonics generated by the non-linier loads that will accumulate and delivered to thepower system. So the harmonics will be able to disrupt the power quality of electrical powersystems.As a non-linear load, essential lamps produce harmonic distortion, both harmoniccurrents and voltage. In this study concluded that the different brands of essential lamp showed thedifferent value of Total HarmonicsDistortion (THD)
MICROCONTROLLER ATMEGA8535 SEBAGAI BASIS PENGENDALI KECEPATAN MOTOR INDUKSI SATU FASA Heri Suryo; Achmad Solichan
MEDIA ELEKTRIKA Vol 8, No 1 (2015): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (549.181 KB) | DOI: 10.26714/me.8.1.2015.%p

Abstract

Pada umumnya motor induksi berputar dengan kecepatan konstan dengan tegangan penuh. Pada kebutuhan tertentu kecepatan motor induksi perlu diatur kecepatan putarannya. Dalam tugas akhir ini, saya menggunakan mikrokontrol ATMega8535 sebagai inti proses dan menggunakan bahasa basic dalam pemrograman. Pada bagian pendukung ada driver SSR (Solid State Relay) dan bagian rangkaian counter RPM untuk menghitung banyaknya putaran pada suatu rentang waktu tertentu dengan inti menggunakan LM358, photodiode dan LED putih yang kemudian dimunculkan di LCD. Dari berbagai percobaan, motor induksi ketika diberi tegangan penuh 220V maka motor berputar dengan maksimal dan konstan, namun ketika dihubungkan mikro maka terjadi kecepatan yang tidak stabil karena singal keluaran mikro mencacah tegangan dan juga jika dilihat dari oscilloscope terjadi gelombang loncatan singal, ketika diberi kapasitor yang terjadi motor induksi bisa lebih stabil dan mengurangi loncatan gelombang. Semakin tinggi kecepatan maka semakin besar daya yang dipakai. Pada kecepatan rendah motor induksi AC tidak bisa berjalan stabil.Kata Kunci : ATMega8535, Motor Induksi Satu Phasa, solid state relay, rangkaian counter rpm
PENGARUH NILAI TEGANGAN MASUKAN TERHADAP REGULASI TEGANGAN PADA IC L7805 SEBAGAI POSITIVE VOLTAGE REGULATOR Nurul Ulfa; Julaipah Julaipah; Aufani Ferinda Anggoro
MEDIA ELEKTRIKA Vol 11, No 1 (2018): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (962.904 KB) | DOI: 10.26714/me.11.1.2018.%p

Abstract

Keberadaan perangkat elektronik tidak dapat dilepaskan dari sistem catu daya. Salah satu bagian dari sistem tersebut adalah regulator tegangan  yang berfungsi menghasilkan tegangan keluaran DC stabil pada nilai tertentu. Untuk tegangan keluaran positif 5 Volt, jenis regulator yangumum digunakan adalah IC L7805. Meski lembar data mencantumkan tegangan masukan maksimal untuk IC tersebut, nilai masukan minimum untuk menghasilkan keluaran 5 Volt stabil tidak diketahui secara pasti. Tujuan dari penelitian ini adalah mengetahui berapa nilai tegangan masukan minimum tersebut dan pengaruhnya terhadap regulasi tegangan. Percobaan pengukuran menggunakan sebuah rangkaian yang terdiri dari IC L7805, 2 buah kapasitor (0,33 µF dan 0,1µF), programmable DC power supply dan sebuah multimeter digital. Percobaan diulang tiga kali untuk kondisi tanpa beban (no load) dan berbeban (full load) sebesar 2KΩ, 4KΩ, 6KΩ, 8KΩ dan 10KΩ. Hasil-hasil percobaan menunjukkan bahwa tegangan masukan minimum untuk semua kondisi tersebut adalah 6,6 Volt. Jika tegangan masukan semakin turun dari nilai minimum, maka semakin besar nilai persentase regulasi dan ini menunjukkan kinerja regulator yang semakin buruk. Dalam perancangan rangkaian catudaya, untuk memastikan bahwa tegangan keluaran positif stabil pada 5 Volt, disarankan menggunakan tegangan masukan ke regulatorsekurang-kurangnya ±7 Volt.Keywords:tegangan masukan, regulasi, L7805, regulator
EFEKTIFITAS PEMASANGAN KAPASITOR SEBAGAI METODE ALTERNATIF PENGHEMAT ENERGI LISTRIK M. Tony Prasetyo; Luqman Assaffat
MEDIA ELEKTRIKA Vol 3, No 2 (2010): Electrical Engineering
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1612.936 KB) | DOI: 10.26714/me.3.2.2010.%p

Abstract

Efficiency needs to be done by PLN as a provider of electrical energy and of course also by the user community as consumers of electrical energy. One of the efficiency measures to conserve energy use in the community is the use of energy-efficient electical appliances (energy saver) areused both in business, commercial or industrial or domestic sector. Energy-efficient appliances are now widely sold in the wider community as they seek to offset the cost of electrical energy consumption. Equipment generally contains capacitor banks or elco (electrolyt condensator) whichcan reduce electric currents, but no significant effect on consumer savings account payments.The Study that's obout improving the power factor has been more on the side of the electricity supplier. both in transmission and distribution. On the load side (electricity consumers), the measurement of power factor and load balancing only on the main panel or distribution ponel.so that the measured accumulated loads of different types of loads.So far research on increasing the load power factor only produces the resulting level of power efficiency and whether this level can still be expected usefulness in relieving the financial burden of the electricity customer bills or not. So we need to do a study b determine the efficiencyof the dominant power generated by the load in conjunction with electric power triangle.Keywords : Power Capacitor, Load, efficiency of electric power
ANALISIS PENYETELAN PROTEKSI ARUS LEBIH PENYULANG CIMALAKA DI GARDU INDUK 70 kV SUMEDANG Fajar Pranayuda; Achmad Solichan; M.Toni Prasetyo
MEDIA ELEKTRIKA Vol 5, No 2 (2012): MEDIA ELEKTRIKA
Publisher : PSTE UNIMUS

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (658.866 KB) | DOI: 10.26714/me.5.2.2012.%p

Abstract

20 kV distribution of PLN is not free from distractions short circuit. Greatest short circuit fault current occurs at 20 kV bus bar. This led to widespread outages as a result of the major security operation. The aim of this study was to identify the final interruption of short circuit current, short circuit fault current to calculate and determine the values Over Current Relay (OCR) and Ground Fault Relay (GFR). This study purposed to calculate short circuit current. The subject of research is the disturbances that occurred in Cimalaka feeders. The data required for this study were obtained from the Area Manager Distribution of Bandung. The data is analyzed to determine the magnitude of short circuit current and Over Current Relay (OCR) and Ground Fault Relay (GFR) adjustment. The results show the short circuit fault current at 0% distance from feeder is 2428,391 A and short circuit current for 3 phase is 2103,049 A short circuit fault current and the second phase of 570,406 A short circuit fault current one phase to the ground. The difference in the relay settings data from the field with the calculation results showed that the differences are not too significant, so the ability of the relays is still good. Thus, the feeder protection relays Cimalaka at 70 kV substation Sumedang still good and doesn’t need to be reset. Keywords: Over Current Relay

Page 9 of 21 | Total Record : 207