cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
Bulletin of Electrical Engineering and Informatics
ISSN : -     EISSN : -     DOI : -
Core Subject : Engineering,
Bulletin of Electrical Engineering and Informatics (Buletin Teknik Elektro dan Informatika) ISSN: 2089-3191, e-ISSN: 2302-9285 is open to submission from scholars and experts in the wide areas of electrical, electronics, instrumentation, control, telecommunication and computer engineering from the global world. The journal publishes original papers in the field of electrical, computer and informatics engineering.
Arjuna Subject : -
Articles 3,350 Documents
A novel 19-level inverter topology based on a single direct current source and reduced component count Taoufiq El Ansari; Ayoub El Gadari; Youssef Ounejjar
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.11776

Abstract

Conventional multilevel inverters (MLI) provide low harmonic distortion but often require many switches, passive components, and voltage sensors, increasing cost, size, and control complexity. This paper proposes a compact 19-level modified split-packed U-cell (MSPUC) inverter powered through one independent direct current (DC) supply source. The proposed configuration employs a reduced number of switches and only three capacitors. Its key contribution is the natural self-balancing of capacitor voltages under sensorless open-loop pulse width modulation (PWM) operation, eliminating the need for additional voltage sensors or auxiliary balancing circuits. In addition, the topology achieves a total standing voltage per unit (TSVpu) of 4.22 and a cost function (CF) of 1.70, indicating reduced voltage stress and improved structural efficiency. MATLAB/Simulink simulations are performed under steady-state conditions, load variations, nonlinear loading, switching-frequency variation, and sudden DC-source disturbances. The obtained results confirm stable capacitor voltage regulation, fast dynamic response, and high-quality output waveforms. Under the nominal condition of R=20 ohm and L=20 mH, the load current total harmonic distortion (THD) is limited to 0.96% without using any external filter. Therefore, the proposed MSPUC inverter provides a compact, cost-effective, and low-complexity solution for efficient power electronic conversion systems.
Clinical risk-aware routing for secure IoMT data in edge-fog-cloud environments Rayane ElRaba'a; Soha Rawas; Ali El-Zaart
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.13705

Abstract

The internet of medical things (IoMT) enables continuous, real-time monitoring of patients through wearable and bedside sensors, but conventional edge-fog-cloud routing strategies optimize only network-centric quality of service (QoS) metrics and ignore the clinical urgency of the transmitted data, creating a safety risk for high-risk patients. This paper proposes fog-aware patient-network scoring (FA-PNS), a continuous, clinical risk-aware routing framework that embeds a normalized patient risk score directly into the routing utility function through an elastic clinical penalty mechanism, allowing routing sensitivity to scale smoothly with patient risk rather than relying on fixed thresholds. FA-PNS is evaluated on a synthetic dataset of 10,000 IoMT patient instances against five baseline routing strategies (latency-based, shortest-path, congestion-aware, weighted multi-metric, and priority-based). Results show that FA-PNS reduces the unsafe routing rate for high-risk patients from 93.33% (latency-based routing) to 3.33%, while improving high-risk patient end-to-end latency by 15.01% compared with priority-based routing (68.91 ms versus 81.08 ms), with all improvements statistically significant (paired t-test, p
A hybrid AES-blockchain model for decentralized image security in cloud environments Suryawanshi, Vishnu A.; Sharma, Nakul; Mali, Ramesh Yashwant; Tukaram Lohar, Anil; Padmakarrao Karlekar, Nandkishor; Ambaji Bogam, Vishal
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.13215

Abstract

The growing tendency to use cloud storage for image data is a major concern for confidentiality, integrity and authenticity. Although the advanced encryption standard (AES) or the digital signatures offer protection, they cannot be guaranteed to be secure. Single-point failures and centralized cloud architecture are not resistant to single-point failures. This paper suggests a hybrid model that incorporates an improved AES algorithm. Authentication is based on a blockchain encryption algorithm to attain decentralized and tamper-resistant image security. This is needed in a private environment setting. The suggested model encrypts and divides the pictures with the help of an optimized version of AES algorithm and stores them. It scatters encrypted fragments on cloud nodes spread across a distributed cloud and keeps hash records of authentication on a blockchain ledger. Experimental analysis shows a faster encryption speed and smaller key management. The complexity is improved as compared to the standard AES algorithm. The integration of blockchain ensures integrity and non-repudiation, addressing the limitations of cryptographic systems.
CornLeaf-MIA Net: a novel deep learning architecture for corn leaf disease detection in precision agriculture Mohamad Ilyas Abas; Dewa Oka Suparwata; Isminarti Isminarti; Asminar Asminar; Muh. Syahlan Natsir
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.14038

Abstract

Early detection of corn leaf diseases is important for maintaining crop productivity and supporting precision agriculture. This study proposes CornLeaf-multi-scale intelligent architecture network (CornLeaf-MIA Net), a lightweight convolutional neural network (CNN) for multiclass classification of blight, common rust, gray leaf spot, and healthy corn leaves. A dataset of 4,013 labeled images was preprocessed through resizing, normalization, and training-stage augmentation. The proposed model was evaluated against MobileNetV2, VGG16, and ResNet50 under identical experimental conditions. CornLeaf-MIA Net achieved 98.38% testing accuracy, with weighted precision, recall, and F1-score of 98.50%, 98.38%, and 98.40%, respectively. The model contains 2,982,052 trainable parameters and achieved a training-validation accuracy gap of 0.71%. It also outperformed MobileNetV2 (94.40%), VGG16 (94.89%), and ResNet50 (95.39%) in testing accuracy. The trained model was implemented in a Flask-based web application using OpenCV and TensorFlow for automated multi-leaf disease diagnosis. The results indicate that the proposed task-specific multi-scale CNN provides high classification performance with a relatively compact architecture and demonstrates practical applicability through web-based implementation.
The effect of dirt and shading on the output power of solar panels at the 50 kWp on-grid rooftop solar power plant Ojak Abdul Rozak; Mohd Zamri Ibrahim; Muhamad Zalani Daud; Syaiful Bakhri; Muhammad Fadjrirullah
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.11291

Abstract

The development of solar power plants has penetrated various sectors, both industry and education. Universitas Pamulang has begun using photovoltaic (PV) technology with an installed capacity of 50 kWp in on-grid solar power plants. However, this technology is greatly influenced by environmental factors, not limited to radiation, temperature, tilt angle, wind speed, and direction; the effects of dirt and shading are also important factors that can affect its output power. With this fairly expensive investment, it must be balanced with efforts to maximize energy production, so that there are no losses or damage, especially due to dirt. With these conditions, a comprehensive analysis of the impact of dirt and shade on PV is needed to optimize its output power. This study applied a comparison method between dirty, clean, and shaded PV to analyze their output power. The results showed a decrease in PV output power due to dirt by 4.52% and shading by 3.28% compared to the output power of the cleaned PV, so it can be concluded that dirt and shading have a strong influence on the decrease in output power, and maintenance and cleaning are essential for optimal PV performance.
Stability and robustness of decision rankings across objective weighting methods in multi-criteria decision-making Itishom Al Khoiry; Dhea Rizky Amelia
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.13862

Abstract

Objective weighting methods derive criterion importance directly from data, but a method producing consistent rankings across aggregation models may not be robust to weight changes. This study jointly evaluates cross-model ranking stability and perturbation robustness in multi-criteria decision-making (MCDM) across five objective weighting methods: entropy, criteria importance through intercriteria correlation (CRITIC), method based on the removal effects of criteria (MEREC), principal component analysis (PCA), and standard deviation (SD). Two datasets were used: a renewable energy case (five alternatives and ten criteria) and a supplier-selection case (ten alternatives, eleven criteria) for external validation. Each weight vector was applied to five MCDM aggregation models: visekriterijumska optimizacija i kompromisno resenje (VIKOR), complex proportional assessment (COPRAS), multi-objective optimization on the basis of ratio analysis (MOORA), evaluation based on distance from average solution (EDAS), and technique for order preference by similarity to ideal solution (TOPSIS). Stability was measured using rank correlation, rank shift, and rank reversal; robustness through criterion-weight perturbation. The two diagnostics are positively associated but not interchangeable. Entropy and MEREC achieved the highest stability and robustness in both cases, whereas PCA was stable across models yet highly sensitive to weight perturbation, indicating that reliability cannot be judged from cross-model stability alone.
Iterative single-ended fault location in isolated neutral 6–35 kV networks Anastasia Igorevna, Uspanova; Saken Koishybaevich, Sheryazov; Igor Vladimirovich, Koshkin; Azamat Akhmetuly, Uspanov; Arman Bolatbekovich, Utegulov
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.12777

Abstract

This paper proposes an iterative approach for accurate single-line-to-ground (SLG) fault localization in 6–35 kV distribution networks with isolated neutrals. Such faults account for approximately 80% of network disturbances and are typically associated with capacitive fault currents and transition resistances of up to 2000 Ohm. Conventional lumped-parameter representations may result in localization errors of up to 50%, primarily because distributed line capacitance is neglected. The developed approach utilizes an exact ABCD-parameter representation of the line in the zero-sequence domain, where distributed electrical parameters are explicitly considered. A least-squares estimation procedure simultaneously determines fault distance and transition resistance from single-ended voltage and current measurements, accounting for capacitive currents and measurement noise. Monte Carlo analysis yielded an average relative fault-location error of 3.13%, with individual errors ranging from 0.33% to 6.83% across the investigated transition resistance range. Further experimental validation using a 12 km, 35 kV overhead distribution line demonstrated a maximum discrepancy of 0.08 km between simulated and experimental results. Consequently, the proposed iterative approach provides accurate single-ended fault localization without requiring line disconnection, making it highly suitable for reliable fault diagnostics in modern smart-grid distribution systems.
Development of a model for detecting diseases of crops using spectral and vegetative features Kassekeyeva, Aislu; Yessenova, Moldir; Ayazbaev, Talgatbek; Abdikerimova, Gulzira; Azieva, Gulmira; Sultanova, Zhanylsyn; Bissengaliyeva, Assyl; Serikbayeva, Assem
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.12164

Abstract

This study presents a leakage-aware framework for feature engineering and spatial data quality assessment of multitemporal Sentinel-2 observations for agricultural land classification. After removing 29 duplicate coordinates, 5,563 samples formed 1,983 connected components under a 5 km rule and were assigned to spatially independent training, validation, and held-out test subsets. Twelve spectral bands and eight vegetation and moisture indices generated 648 spectral, 432 index-derived, and 1,080 combined features. On validation data, the combined representation achieved a macro-F1 of 0.7261 with HistGradientBoosting, while the proposed out-of-fold (OOF)-stacked multispectral machine learning fusion (OS-MMF) achieved 0.7408. Across ten repeated whole-component partitions, the combined representation obtained a mean macro-F1 of 0.7362. Removing the redundant McFeeters normalized difference water index (NDWI) features produced comparable performance. Final held-out evaluation of OS-MMF yielded an accuracy of 0.7803 and a macro-F1 of 0.7080, supporting reproducible spatially controlled classification without establishing universal model superiority.
Unified mobile framework for electrocardiogram-based myocardial infarction detection and arrhythmia classification Ahmad Hasan, Sameer; Alabed, Samer; Ayyoub, Talal; Shahin, Abdullah
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.11689

Abstract

Cardiovascular diseases (CVDs), particularly myocardial infarction (MI) and arrhythmias, require timely and accurate computational support for screening and follow-up. This study presents a unified internet of things (IoT)-enabled electrocardiogram (ECG) framework for mobile MI detection and multiclass arrhythmia classification. The framework integrates ECG preprocessing using biorthogonal and median filtering, machine learning (ML)-based interpretation, and mobile application delivery for prompt diagnostic feedback. The main contribution of this work is the integration of MI detection and multiclass arrhythmia classification within a single mobile-health workflow. The best random forest (RF) model achieved 96.89% accuracy for MI detection. For arrhythmia classification, the selected RF model achieved 89.59% accuracy on the held-out test set. These findings support the potential of the proposed framework as a mobile decision-support system for ECG interpretation and remote follow-up. Because evaluation was performed on row-level samples rather than patient-disjoint data, the reported results should be interpreted as within-dataset decision-support performance. Overall, the framework provides a practical link between ECG interpretation and mobile-health delivery while supporting further validation in real-world deployment settings.
Uncertainty-aware circular residual U-Net for electrocardiogram denoising under realistic nonstationary noise Rifai, Ahmad; Nurmaini, Siti; Suprapto, Bhakti Yudho; Partan, Radiyati Umi; Firdaus, Firdaus
Bulletin of Electrical Engineering and Informatics Vol 15, No 6: December 2026
Publisher : Institute of Advanced Engineering and Science

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.11591/eei.v15i6.13968

Abstract

Electrocardiogram (ECG) signals in ambulatory monitoring are frequently degraded by nonstationary baseline wander (BW), muscle artifact (MA), and electrode-motion (EM) artifact. This study proposed an uncertainty-aware circular residual U-Net integrating circular convolution, residual-noise prediction, a morphology-aware boundary loss, and Monte Carlo (MC) dropout. Clean QT database segments were contaminated with Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) noise stress test database noise at input signal-to-noise ratios (SNR) from -6 to 24 dB. Evaluation on 2,560 test segments compared the proposed model with db4 wavelet denoising, convolutional neural network-denoising autoencoder (CNN-DAE), a zero-padded U-Net, and a circular U-Net. The proposed model achieved an output SNR of 11.6789 dB and waveform correlation of 0.9309, with the lowest root mean square error (RMSE), mean absolute error (MAE), percentage root-mean-square difference (PRD), derivative MAE, and boundary MAE of 0.1820, 0.1382, 32.5572, 0.0236, and 0.1678, respectively. Its peak-amplitude error of 0.1998 was comparable to the circular U-Net. Output SNR exceeded CNN-DAE and wavelet denoising by 3.1449 and 2.8925 dB. Predictive uncertainty strongly correlated with reconstruction error (r=0.8239, p

Filter by Year

2012 2026


Filter By Issues
All Issue Vol 15, No 6: December 2026 Vol 15, No 5: October 2026 Vol 15, No 4: August 2026 Vol 15, No 3: June 2026 Vol 15, No 2: April 2026 Vol 15, No 1: February 2026 Vol 14, No 6: December 2025 Vol 14, No 5: October 2025 Vol 14, No 4: August 2025 Vol 14, No 3: June 2025 Vol 14, No 2: April 2025 Vol 14, No 1: February 2025 Vol 13, No 6: December 2024 Vol 13, No 5: October 2024 Vol 13, No 4: August 2024 Vol 13, No 3: June 2024 Vol 13, No 2: April 2024 Vol 13, No 1: February 2024 Vol 12, No 6: December 2023 Vol 12, No 5: October 2023 Vol 12, No 4: August 2023 Vol 12, No 3: June 2023 Vol 12, No 2: April 2023 Vol 12, No 1: February 2023 Vol 11, No 6: December 2022 Vol 11, No 5: October 2022 Vol 11, No 4: August 2022 Vol 11, No 3: June 2022 Vol 11, No 2: April 2022 Vol 11, No 1: February 2022 Vol 10, No 6: December 2021 Vol 10, No 5: October 2021 Vol 10, No 4: August 2021 Vol 10, No 3: June 2021 Vol 10, No 2: April 2021 Vol 10, No 1: February 2021 Vol 9, No 6: December 2020 Vol 9, No 5: October 2020 Vol 9, No 4: August 2020 Vol 9, No 3: June 2020 Vol 9, No 2: April 2020 Vol 9, No 1: February 2020 Vol 8, No 4: December 2019 Vol 8, No 3: September 2019 Vol 8, No 2: June 2019 Vol 8, No 1: March 2019 Vol 7, No 4: December 2018 Vol 7, No 3: September 2018 Vol 7, No 2: June 2018 Vol 7, No 1: March 2018 Vol 6, No 4: December 2017 Vol 6, No 3: September 2017 Vol 6, No 2: June 2017 Vol 6, No 1: March 2017 Vol 5, No 4: December 2016 Vol 5, No 3: September 2016 Vol 5, No 2: June 2016 Vol 5, No 1: March 2016 Vol 4, No 4: December 2015 Vol 4, No 3: September 2015 Vol 4, No 2: June 2015 Vol 4, No 1: March 2015 Vol 3, No 4: December 2014 Vol 3, No 3: September 2014 Vol 3, No 2: June 2014 Vol 3, No 1: March 2014 Vol 2, No 4: December 2013 Vol 2, No 3: September 2013 Vol 2, No 2: June 2013 Vol 2, No 1: March 2013 Vol 1, No 4: December 2012 Vol 1, No 3: September 2012 Vol 1, No 2: June 2012 Vol 1, No 1: March 2012 List of Accepted Papers (with minor revisions) More Issue