cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota malang,
Jawa timur
INDONESIA
Jurnal Mahasiswa TEUB
Published by Universitas Brawijaya
ISSN : -     EISSN : -     DOI : -
Core Subject : Education,
Arjuna Subject : -
Articles 25 Documents
Search results for , issue "Vol 6, No 2 (2018)" : 25 Documents clear
PENGARUH LAPISAN KONDUKTIF VERTIKAL TERHADAP TINGKAT ARUS BOCOR PADA SUSUNAN ELEKTRODA PLAT-PLAT DAN PLAT-JARUM ISOLATOR KACA Sipa Peberina Ginting; Mochammad Dhofir
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

ABSTRAK Jurnal ini membahas hasil penelitian tentang pengaruh dari perubahan masa garam (gr) yang mempenggaruhi nilai moll larutan NaCl (moll), konsentrasi larutan NaCl (molar) dan nilai konduktivitas larutan NaCl (mS/cm) terhadap perubahan nilai arus bocor pengukuran pada permukaan isolator kaca. Semakin meningkat massa (gr) NaCl, moll larutan NaCl meningkat maka, meningkat juga nilai konduktivitas (mS/cm). Variasi luas objek uji yang terkontaminasi mempengaruhi nilai arus bocor pengukuran pada permukaan isolator kaca dengan perubahan nilai tegangan uji. Hasil penelitian nilai konduktivitas terkecil yakni dengan 250 ml air mineral, 3 gr NaCl, yakni sebesar 20,68 mS/cm. Nilai konduktivitas dengan nilai terbesar yakni dengan 250 ml air mineral, 30 gr NaCl, yakni sebesar 205,58 mS/cm.untuk nilai dari pengaruh konduktivitas terendah larutan NaCl terhadap arus bocor dengan tegangan uji 25 kV pada variasi OBA-4 = 45,25 µA, pada variasi OBB-4 = 39,30 µA. Untuk pengaruh nilai konduktivitas terbesar terhadap arus bocor pada 25 kV pada variasi OBA-4 = 69,06 µA, pada variasi OBB-4 = 51,41 µA. Luas permukaan objek uji yang terkontaminas berbanding lurus terhadap perubahan nilai arus bocor permukaan dengan variasi kondutivitas dan perubahan tegangan uji. Semakin tinggi nilai konduktivitas dan semakin luas permukaan objek uji yang terkontaminasi terhadap perubahan tegangan uji, maka akan semakin tinggi nilai arus bocor pengukuran pada permukaan isolator kaca. Kata kunci: Isolator kaca, arus bocor permukaa isolator kaca, molaritas larutan NaCl, konduktivitas larutan NaCl   ABSTRACT This paper is discusses about the results of research the effect about the change of salt's mass value (gr) which is affecting of the moll's value of NaCl (moll) and the concentration of NaCl's solution (molar)  and the conductivity value of NaCl (mS / cm) to the change of leakage current,s value on the surface of glass insulator.when the mass of NaCl (gr) more increasing, moll will increas (moll) and the conductivity more increasing (mS/cm). The variety of the object which is that contaminated by the polutions will changes the value of leakage current’s value with the changes of the voltage’s value. The conductivity value with the largest value with 250 ml of mineral water, 30 g NaCl, ie 205.58 mS / cm.for the value of the lowest conductivity effect of NaCl solution to leakage current with 25 kV test voltage on OBA-4 = 45,25 μA, on the variation of OBB-4 = 39.30 μA. For the effect of the greatest conductivity value on leakage current at 25 kV on OBA-4 variation = 69,06 μA, on variation OBB-4 = 51,41 μA.the surface area of the object which is contaminated by polution, the value will directly proportional of leakage current’s value with the variasion of conductivity and the voltage’s value. If the value of conductivity increased, and more large the area of condutivity the value of leakage current more ncreases. Keywords : Glass Insulator, leakage current, the molarity of NaCl,  the conductivity of NaCl
SISTEM PENGAMBILAN KEPUTUSAN UNTUK DIAGNOSIS SUDDEN CARDIAC DEATH (SCD) BERBASIS POINCARE PLOT OF RR-INTERVAL DIFFERENCE (PORRID) MENGGUNAKAN METODE FUZZY LOGIC Rivan Rerizki Putera; Ponco Siwindarto
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Sudden Cardiac Death (SCD) merupakan kejadian kematian tidak terduga yang disebabkan oleh masalah pada jantung yang terjadi dalam waktu singkat pada orang yang memiliki riwayat penyakit jantung maupun tidak. Umumnya, SCD disebabkan oleh Ventricullar Fibrillation (VF) yaitu kondisi dimana terjadi gangguan pada kelistrikan jantung, sehingga ventrikel jantung bergetar secara tidak terkontrol. Salah satu cara untuk mendiagnos SCD yang disebabkan oleh VF adalah dengan teknik Poincare Plot of RR-Interval Difference (PORRID). Dengan teknik PORRID, akan dihasilkan suatu pola yang khas antara pasien normal dan memiliki kelainan, sehingga dapat diketahui pasien tersebut berpotensi mengalami SCD atau tidak. Dari beberapa hal tersebut, maka penulis membuat sistem pengambilan keputusan untuk diagnosis SCD menggunakan metode Fuzzy Logic. Pada pembuatan sistem ini, dimulai dengan pembuatan deskriptor standard yang berisi parameter-parameter yang mampu mengkuantifikasikan informasi pada pola yang dihasilkan. Kemudian dilakukan pembuatan himpunan fuzzy dan aturan-aturan yang digunakan. Pada pengujiannya, terdapat 40 sampel uji dimana 20 sampel merupakan kategori Non-SCD dan 20 sampel merupakan kategori SCD. Untuk kategori Non-SCD, sistem ini dapat mendiagnosis 19 sampel dengan benar. Sedangkan untuk kategori SCD, sistem ini dapat meniagnosis 16 sampel dengan benar. Sistem pengambilan keputusan untuk diagnosis SCD menggunakan fuzzy logic ini memiliki akurasi sebesar 87,5%. Kata kunci: Diagnosis SCD, PORRID, Logika Fuzzy, SCD. ABSTRACT Sudden Cardiac Death (SCD) is an unexpected death event caused by heart problems that occur in a short time that occurs in people who have a history of heart disease or not. Generally, SCD is caused by Ventricullar Fibrillation (VF) which is a condition where there is a disruption in the electrical heart, so the heart ventricles vibrate uncontrollably. One way to diagnose SCD caused by VF is by Poincare Plot of RR-Interval Difference (PORRID). With PORRID, a typical pattern will be generated between normal patients and having abnormalities, so it can be known that the patient is potentially SCD or not. From some of these things, the authors make a decision-making system for SCD diagnosis using Fuzzy Logic method. In the manufacture of this system, starting with the manufacture of standard descriptor that contains parameters that can quantify the information on the resulting pattern. Then made the set of fuzzy and the rules used. In the test, there were 40 test samples in which 20 samples were Non-SCD category and 20 samples were SCD category. For Non-SCD category, this system can correctly diagnose 19 samples. As for the SCD category, this system can diagnose 16 samples correctly. The decision-making system for SCD diagnosis using fuzzy logic has an accuracy of 87.5%. Keywords: Diagnose SCD, PORRID, Fuzzy Logic, SCD
PENGARUH LETAK PITA KONDUKSI PADA PERMUKAAN ISOLATOR DENGAN ELEKTRODA TIDAK SERAGAM TERHADAP TINGKAT ARUS BOCOR Amadea, Cinta Hanifa; Dhofir, Mochammad
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Jurnal ini memaparkan hasil pengujin tentang pengaruh letak pita konduksi dengan  susunan elektroda plat berbentuk jarum-plat terhadap arus bocor yang terjadi di permukaan isolator kaca. Elektroda yang digunakan adalah elektroda jarum yang tersambung ke tegangan tinggi dan elektroda piring yang dibumikan. Untuk pengotor yang digunakan adalah larutan natrium klorida dengan varisai massa garam yaitu: 5 gr, 15 gr, 25 gr, 35 gr dan 45 gr. Setelah massa garam didapat lalu dicampurkan kedalam 250 ml air mineral pada masing-masing massa garam. Setelah larutan garam didapat maka dapat pula dihitung nilai konduktivitas larutannya, kemudian larutan natrium klorida dioleskan pada permukaan isolator kaca. Lapisan pita konduksi dibagi menjadi tiga bagian yaitu: ground, middle, dan HV. Langkah berikutnya adalah menguji arus bocor yang terjadi pada masing-masing lokasi pita konduksi di permukaan isolator kaca dengan memberikan tegangan tinggi AC mulai dari 5 kV, 9 kV, 13 kV, 17 kV, 21 kV dan 25 kV. Setelah didapat arus bocor yang terjadi di permukaan isolator kaca maka dapat dihitung resistansi permukaan isolator kaca, rugi-rugi daya nyata, dan rugi energi yang terjadi dalam satu tahun dengan asumsi terdapat 8760 jam setiap tahunnya. Berdasarkan hasil pengujian didapatkan bahwa nilai konduktivitas larutan natrium klorida berpengaruh terhadap arus bocor yang terjadi di permukaan isolator kaca, semakin besar nilai konduktivitas larutan natrium klorida maka semakin besar pula arus bocor yang terjadi pada masing-masing bagian pita konduksi. Tegangan uji yang diberikan juga berpengaruh terhadap arus bocor yang terjadi di permukaan isolator kaca, semakin besar tegangan uji yang diberikan maka arus bocor yang terjadi juga semakin besar. Letak pita konduksi juga berpengaruh terhadap arus bocor yang terjadi di permukaan isolator kaca. Kata kunci : pita konduksi, konduktivitas larutan natrium klorida, arus bocor, tegangan uji, rugi-rugi daya nyata, rugi energi dalam satu tahun. ABSTRACT This paper explained about effect of conductive band location with non homogen electrode to leakage current level that occurs on glass isolator surface. Electrode were used is needle electrode connected to high voltage and ground plate electrode. For the impurities that used is sodium chloride solution with salt mass variation that is: 5 gr, 15 gr, 25 gr, 35 gr and 45 gr. After obtained salt mass then mixed to 250ml mineral water to each salt mass. After obtained salt solution then the measurement of value solution conductivity can be obtained, after that the sodium chloride solution can be lubricated with glass isolator surface were divided into three parts namely: ground, middle, and HV. Next step is test leakage current to each conductive band location on glass isolator surface by giving ac voltage from 5kV, 9kV, 13kV, 17kV, 21kV, and 25kV. After obtained leakage current were occurs on glass isolator surface, so the measurement of resistance glass isolator surface can be obtained, real power loss, energy loss that occurs for 1 year with assumption there are 8760 hours for each year. The test result can be conclude that the calue of sodium chloride solution conductivity affect to  leakage current were occurs on glass isolator surface, the greater conductivity value of the sodium chloride solution mean the greater leakage current that occurs in each parts of the conduction band too. The test voltage also affects to the leakage current that occurs on the glass isolator surface, the greater voltage test given can make the leakage current greater too. The conductive band location also affects the leakage current
PENGARUH LOKASI PITA KONDUKSI TERHADAP TINGKAT ARUS BOCOR ISOLATOR SILICONE RUBBER Pegy Lestari; Mochammad Dhofir; Rini Nur Hasanah
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini membahas tentang hasil pengujian pengaruh lokasi pita konduksi terhadap arus bocor yang mengalir pada isolator silicone rubber dengan susunan elektroda plat-plat. Untuk menyamakan kondisi di lapangan, digunakan sebuah pengotor yang berupa larutan natrium klorida untuk merepresentasikan zat polutan yang menempel pada isolator silicone rubber. Pada penelitian ini, larutan natrium klorida (zat polutan) disaputkan pada permukaan isolator silicone rubber dengan menggunakan spons dengan lebar lapisan pita konduksi dan lokasi pita konduksi yang telah ditentukan. Dari hasil pengujian, konduktivitas larutan natrium klorida berpengaruh terhadap arus bocor. Pada tegangan uji 20 kV, lokasi ground, lebar lapisan pita konduksi 50 mm, dan nilai konduktivitas larutan NaCl 34,37 mS/cm, nilai arus bocor sebesar 23,58 μA, sedangkan pada nilai konduktivitas larutan NaCl 171,34 mS/cm, nilai arus bocor sebesar 33,23 μA. Semakin besar konduktivitas larutan natrium klorida maka semakin besar pula nilai arus bocor. Selain itu, lokasi pita konduksi berpengaruh terhadap arus bocor. Pada tegangan uji 20 kV, konduktivitas larutan NaCl 171,34 mS/cm, lebar lapisan pita konduksi 50 mm, nilai arus bocor pada lokasi middle sebesar 12 μA. Sedangkan pada lokasi high voltage, nilai arus bocor sebesar 17,37 μA, dan nilai arus bocor pada lokasi ground sebesar 33,23 μA. Dari ketiga lokasi tersebut, nilai arus bocor yang terbesar adalah pada lokasi ground, kemudian high voltage, dan yang paling kecil pada lokasi middle. Lebar lapisan pita konduksi juga berpengaruh terhadap arus bocor yang permukaan isolator silicone rubber. Pada tegangan uji 20 kV, konduktivitas larutan NaCl 171,34 mS/cm, lokasi ground, nilai arus bocor pada lebar lapisan pita konduksi 30 mm adalah 19,19 μA. Sedangkan pada lebar lapisan pita konduksi 40 mm, nilai arus bocor sebesar 19,52 μA, dan nilai arus bocor pada lebar lapisan pita konduksi 50 mm adalah 133,27 μA. Semakin lebar lapisan pita konduksi maka permukaan isolator semakin bersifat konduktif dan arus bocor yang mengalir pada permukaan isolator silicone rubber juga semkain besar. Kata kunci: konduktivitas larutan natrium klorida, lokasi pita konduksi, arus bocor.   ABSTRACT This study discusses about the testing results from the influence of conduction band location on leakage current flowing on silicone rubber isolator with plate electrode arrangement. To equate the conditions in the field, an impurity is used in the form of liquid sodium chloride to represent the pollutant attached to the silicone rubber insulator. In this study, the liquid sodium chloride (pollutant material) was coated on the surface of the silicone rubber insulator by using a sponge with the specified layer width and location of the conduction band. From the test results, the conductivity of the liquid sodium chloride has an effect on leakage current. At 20 kV test voltage, at the ground location, 50 mm conduction band width, and the conductivity value of liquid NaCl was 34,37 mS / cm, leakage current value equal to 23,58 μA, while at conductivity value of liquid NaCl was 171,34 mS / cm, the leakage current value is 33.23 μA. The greater the conductivity of the liquid sodium chloride, thereby the greater the leakage current value. In addition, the location of the conduction band affects the leakage current. At a test voltage of 20 kV, the conductivity of liquid NaCl was 171,34 mS / cm, the width of the conduction band 50 mm, the leakage current value at the middle location is 12 μA. At high voltage location, the value of leakage current is 17,37 μA, and the leakage current value at ground location is 33,23 μA. From the three locations, the largest value of leakage current is on the ground location, then on the high voltage, and the smallest is on the middle location. The width of the conduction band layer also affects the leakage current of the silicone rubber insulator surface. At 20 kV test voltage, the conductivity of the liquid NaCl was 171.34 mS / cm, at the ground location, the leakage current value at the width of the 30 mm conduction band layer was 19.19 μA. The leakage current value is 19.52 μA  in the width of 40 mm conduction band, and the leakage current value at the width of the 50 mm conduction band layer is 133.27 μA. When the width of the conduction band layer, is larger the insulator's surface becomes more conductive and the leakage current flowing on the surface of the silicone rubber insulator is also larger. Keywords: conductivity of the liquid sodium chloride, conduction band location, leakage current
KAJIAN TEKNIS INTEGRASI PHOTOVOLTAIC PADA PEMBANGKIT LISTRIK TENAGA MIKRO HIDRO (PLTMH) ANDUNGBIRU UNTUK MENGATASI PENINGKATAN PELANGGAN Moch. Rizki Indra Dwijayanto; Teguh Utomo; Mahfudz Shidiq
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pembangkit listrik memilki peranan dalam laju pertumbuhan ekonomi di indonesia. Namun pada pertumubuhan ekonomi yang pesat sekarang masih terdapat beberapa wilayah di indonesia yang belum terjangkau listrik oleh PT. PLN (Perusahaan Listrik Negara). Salah satu solusi dari masalah tersebut adalah pembangunan PLTMH (Pembangkit Listrik Tenaga Mikro Hidro) pada wilayah yang memilki potensi air yang  melimpah, salah satunya yaitu di Desa Andungbiru kecamatan Tiris kabupaten Probolinggo. Semenjak awal pembangunan PLTMH telah mengalami beberapa perubahan seiring dengan bertambahnya kebutuhan beban  sehingga mendorong pihak pengelola melakukan peningkatan kapasitas pembangkit. Kajian ini akan dilakukan integrasi PLTMH dengan photovoltaic. Berdasarkan sistem hibrid yang dilakukan, 125,35 kVA akan disuplai photovoltaic untuk memenuhi kebutuhan beban terpasang, dan photovoltaic yang dibutuhkan sebanyak 553 modul dengan kapasitas 300Wp. Kata kunci : PLTMH, Photovoltaic. Power plants have a role in the rate of economic growth in Indonesia. But in the rapid economic growth now there are still some areas in Indonesia that have not reached electricity by PT. PLN (Perusahaan Listrik Negara). One solution of the problem is the build of PLTMH (Micro Hydro Power Plant) in areas with abundant water potential, one of them is in Andungbiru village, Tiris district, Probolinggo regency. Since the beginning of the development of PLTMH has undergone several changes along with the increasing demand of the load so as to encourage the manager to increase the capacity of the plant. This study will be done with PLTMH integration with photovoltaic. Based on the hybrid system, 125,35 kVA will be supplied with photovoltaic to meet installed load requirements, and the required photovoltaic is 553 modules with capacity 300Wp. Keywords: PLTMH, Photovoltaic, Real Power. 
ANALISIS PENGARUH PENINGKATAN GAIN, VSWR, DAN PENURUNAN RETURN LOSS TERHADAP SUHU LINGKUNGAN PADA ANTENA MIKROSTRIP ARRAY DENGAN FREKUENSI 2.4 GHZ Bagus Juliyanto; Rudy Yuwono; Dwi Fadila Kurniawan
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak – Pada penelitian ini akan dibahas tentang perancangan dan pembuatan lima buah antena mikrostrip, yaitu tiga buah antena mikrostrip dan dua buah antena mikrostrip array dengan frekuensi 2.4 GHz serta menganalisis pengaruh peningkatan Gain, VSWR, dan Return Loss antena tersebut terhadap temperatur lingkungan. Pada antena ini menggunakan bahan substrat dua lapis FR-4 (konstanta dielektrik = 3,9) dan bahan konduktor tembaga. Perancangan dan simulasi antena dilakukan dengan menggunakan program CST Microwave Studio 2014. Kelima antena tersebut di taruh di luar kotak uji dan difungsikan sebagai pemancar yang dipancarkan pada kotak uji. Dan diteliti kenaikan suhu dalam kotak terhadap pancaran antena. Hasil simulasi kelima antena mikrostrip memiliki VSWR dibawah 2 pada frekuensi 2.4 GHz dengan nilai S11 (Return Loss) ≤ -10 dB, axial ratio di atas 10 dB serta memiliki nilai Gain diatas 2 dBi dan 10 dBi untuk antena array. Untuk hasil pengaruh peningkatan Gain, VSWR, dan Return Loss terhadap temperatur lingkungan selama 180 menit terjadi kenaikan temperatur sebesar 0.08℃ pada Antena1, Antena2 memiliki kenaikan 0.16℃, Antena3 memiliki kenaikan 0.41℃, Antena4 memiliki kenaikan 0.6℃, dan Antena5 memiliki kenaikan 0.6℃ Sedangkan kelima antena tersebut mengakibatkan perubahaan suhu dalam kotak, suhu rata-rata yang diakibatkan oleh antena dalam kotak sebesar 24.84℃ pada Antena1, 24.9℃ pada Antena2, 24.84℃ pada Antena3, 25.63℃ pada Antena4 dan 25.82℃ pada Antena5. Kata Kunci : Antena Mikrostrip, pengaruh peningkatan Gain, VSWR, Return Loss, dan perubahan temperatur Abstract-In this research we will discuss about designing and making five microstrip antenna, three microstrip antenna and two microstrip array antenna with frequency 2.4 GHz and analyzing the effect of increasing Gain, VSWR, and Return Loss antenna to the environment temperature. The antenna uses a two-layer substrate FR-4 (dielectric constant = 3.9) and a copper conductor material. The design and simulation of the antenna is done by using CST Microwave Studio 2014 program. The five antennas are placed outside the test box and functioned as transmitters transmitted on the test box. And examined the temperature rise in the box to the antenna jet. The simulation result of the fifth microstrip antenna has VSWR below 2 at 2.4 GHz with S11 value (Return Loss) ≤ -10 dB, axial ratio above 10 dB and Gain value above 2 dBi and 10 dBi for antenna array. For an increase in Gain, VSWR, and Return Loss on environmental temperatures for 180 minutes there was a temperature rise of 0.08 ℃ in Antenna1, Antenna2 had an increase of 0.16 ℃, Antenna3 had an increase of 0.41 ℃, Antenna4 had an increase of 0.6 ℃, and Antenna5 had an increase of 0.6 Untuk While the five antennas resulted in temperature change in the box, the average temperature caused by the antenna in the box was 24.84 ℃ on Antenna1, 24.9 ℃ on Antenna2, 24.84 ℃ on Antenna3, 25.63 ℃ on Antenna4 and 25.82 ℃ on Antenna5. Keywords: Microstrip Antenna, Improved Gain, VSWR, Return Loss, and temperature changes
DESAIN DAN ANALISIS SISTEM KOMUNIKASI RADIO OVER FSO (RoFSO) DENGAN TEKNIK MODULASI EKSTERNAL UNTUK CUACA YANG BERVARIASI Titah Indyra Pasha; Sholeh Hadi Pramono
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Teknologi Radio over Fiber (RoF) merupakan jaringan yang baik untuk integrasi sistem komunikasi nirkabel dan sistem komunikasi optik. Implementasi RoF tergantung pada ketersediaan instalasi kabel serat optik, oleh karena itu, dengan tidak adanya infrastruktur serat, sistem RoFSO yang diusulkan bisa dengan mudah diaplikasikan. Kondisi cuaca seperti hujan, debu, salju, dan kabut / asap menjadi kendala pada media transmisi sistem FSO. Penelitian ini dilakukan secara simulasi dengan Optisystem yang bertujuan untuk mengkaji pengaruh kondisi cuaca pada performansi sistem komunikasi RoFSO menggunakan teknik modulasi eksternal. Parameter kinerja sistem RoFSO dilihat berdasarkan nilai BER dan Q-factor. Hasil penelitian menunjukkan bahwa nilai BER banding lurus terhadap jarak, sedangkan nilai Q-Factor berbanding terbalik terhadap jarak. Kata Kunci: RoFSO, cuaca, eksternal modulasi, BER, Q-Factor, Optisystem.   ABSTRACT Radio over Fiber (RoF) technology is a good network for the integration of wireless communication and optical communication systems. RoF implementation depends on the availability of fiber optic cable installation, therefore in the absence of fiber infrastructure, the proposed RoFSO system can be easily applied. Weather conditions such as rain, dust, snow, and fog / smoke become constraints on FSO system transmission media. This research was conducted simulation with Optisystem which aims to examine the effect of weather conditions on RoFSO communication system performance using external modulation technique. RoFSO system performance parameters are based on BER and Q-factor values. The results show that the value of BER compares directly with distance, while the Q-Factor value is inversely proportional to the distance. Kata Kunci: RoFSO, Weather, External Modulation, BER, Q-Factor, Optisystem
PENGENDALIAN SUHU AIR UNTUK TERAPI PENDERITA HIPERTENSI BERBASIS ARDUINO UNO Idam Almualif; n/a Rahmadwati; Erni Yudaningtyas
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Terapi air hangat membutuhkan suatu sistem pengendalian suhu hal ini disebabkan oleh ketidakstabilan suhu lingkungan dan lamanya proses terapi yang mengakibatkan penurunan suhu, sehingga dirancang sebuah sistem pengendali dengan menggunakan pengendali P yang dapat menjaga suhu menjadi konstan. Penelitian ini menggunakan Arduino Uno yang diaplikasikan sebagai alat pengendali suhu pada kolam terapi. Pengendalian suhu ini dilakukan selama 20 menit pada suhu 40ºC, karena suhu tersebut merupakan suhu optimal yang dibutuhkan untuk proses terapi air hangat. Sistem pengendali suhu ini menggunakan metode 1 Ziegler-Nichols, diperoleh nilai parameter yang sesuai untuk sistem dengan nilai Kp =9,26. Sistem pengontrolan suhu pada air dapat mencapai setpoint 40° C dengan settling time 1.770 s. Kata Kunci: Settling Time, Pengendali P.   ABSTRACT A temperature control system is required by warm water therapy, this is influenced by unstable environment temperature and the periode time of therapy, so a control system using controller is needed to keep the temperature constant. This research use Arduino UNO is a tool that applied in therapy basin for controlling temperature. The temperature is controlled in 40ºC during 20 minutes, because this point is optimal temperature for warm water therapy. This system also use method 1 of  Ziegler-Nichols. The parameter of P Controller Kp = 9.26 is obtained. The setpoint of this system is 40°C with seettling time 1,770s. Keywords: Settling Time, Controller P
KAJIAN EKONOMIS KERUGIAN LISTRIK PLN AKIBAT PENCURIAN DENGAN METODE MERUBAH MCB DAN MEMPENGARUHI PENGUKURAN PADA KWH METER Muhammad Sekti Yolansyah; Teguh Utomo
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Dewasa ini, terdapat banyak kasus pencurian atau pelanggaran pemakaian listrik dengan beragam cara. Hal ini menyebabkan PLN mengalami kerugian karena pencurian listrik sebesar Rp 1,5 triliun per tahun.Pencurian listrik yang berfokus pada kWh meter ada berbagai macam, diantaranya dengan merubah pada sisi MCB dan menambahkan jarum pada kWh meter. Penelitian ini bertujuan untuk mengetahui perbandingan kWh yang tercatat jika instalasi dipasang secara normal dengan instalasi yang sudah diubah dengan merubah pada sisi MCB, menambahkan jarum, dan membandingkan nilai ekonomis yang seharusnya diperoleh PLN  ketika kWh meter dipasang normal dan kWh meter diubah. Metode yang digunakan dalam penelitian untuk pengukuran normal yaitu sebanyak 6 kali putaran piringan dan menggunakan 5 variasi beban,; pengukuran dengan merubah MCB dan menambahkan jarum sama dengan pengukuran normal, hanya saja pada saat merubah MCB merubah 2 A menjadi 4 A, dan pada saat  menambahkan jarum, piringan ditempeli jarum. Hasil penelitian didapatkan rata-rata selisih nilai eror antara kWh meter yang terpasang normal dengan yang sudah diubah pada sisi MCB sebesar 0, dan kWh meter yang terpasang normal dengan yang sudah diubah menambahkan jarum sebesar -44.1586. Selisih total biaya pemakaian listrik selama satu bulan untuk kWh meter normal dengan yang sudah diubah pada sisi MCB adalah sebesar Rp. 165.914.-, dan untuk selisih kWh meter normal dengan yang sudah ditambahkan jarum sebesar Rp. 58.610.-   Kata kunci: kWh Meter, Pencurian, Eror, Biaya pemakaian.   ABSTRACT Today, there were many cases of theft or infringement of electricity in various ways. This was caused PLN to suffer losses due to the theft of electricity amounting to Rp 1.5 trillion per year. Electrical theft focused on kWh meter there were various kinds, such as by changing the side of the MCB and adding a needle on the kWh meter. The objective of this study were found out the recorded kWh ratio if the installation was installed normally with a modified installation by changing on the MCB side, adding a needle, and comparing the economic value that PLN should had obtained when the kWh meter was installed normally and the kWh meter was changed. The method used in the research for normal measurement  as much as 6 times the rotation of the disk and used 5 variations of load ; the measurement by changing the MCB and adding the needle was the same as the normal measurement, only when changing the MCB changes 2 A to 4 A, and when adding the needle, the disk was plugged with a needle. The result showed that the average of error difference between kWh meter that was installed normally with that has been changed on the side of MCB is 0, and kWh meter installed with normal that has been changed add needle equal to -44.1586. The difference in total cost of electricity for one month for normal kWh meter with which has been changed on the MCB side was Rp. 165.914.-, and for the normal kWh meter difference with the added needle of Rp. 58.610.- Keywords: kWh Meter, Theft, Error, Usage fee.
PERANCANGAN BATERAI MANAJEMEN SISTEM PADA BATERAI PAK MOBIL LISTRIK LITIUM -ION 18650 TERSUSUN 20 SERI Alfian Khairi; n/a Soeprapto; Eka Maulana
Jurnal Mahasiswa TEUB Vol 6, No 2 (2018)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Mobil listrik merupakan mobil ramah lingkungan yang menggunakan energi listrik dari baterai sebagai sumber energi, dan menggunakan motor listrik sebagai penggerak sehingga tidak ada gas buang. Dalam  mobil listrik baterai yang digunakan tidak hanya satu, melainkan lebih dari satu sehingga bisa disusun seri ataupun parallel. Baterai tidak boleh digunakan pada kondisi diluar batasnya karna akan mengurangi siklus hidupnya dan lebih cepat untuk diganti sehingga berdampak pada sektor biaya perawatan mobil listrik. Oleh karna itu diperlukan sebuah alat untuk mengatur penggunaan baterai baik saat proses pengisian atau pengosongan. Battery Management Sistem (BMS) merupakan sistem elektronik yang berfungsi untuk mengatur, memonitoring, dan menjaga baterai dari kondisi kondisi yang dapat merusak baterai. BMS ini dapat melakukan proses balancing terhadap 20 sel dengan metode sel ke sel active balancing, arus efektif balancing sebesar 24,48 mA rms. Monitoring tegangan individu sel dengan eror rata-rata 0,054 V, pembacaan arus pengisian dan pengosongan baterai denga eror rata-rata 0,04 A, pembacaan suhu baterai pak dengan eror rata-rata 1,21oC. Dan juga sistem proteksi baterai pak dari kondisi undervoltage, overvoltage, overheat, dan overcurrent bekerja sebagaimana mestinya. Kata kunci: Active Balancing,  baterai manajmen sistem, baterai pak ABSTRACT Electric car is an environmentally friendly car that uses electrical energy from a battery as a source of energy, and uses an electric motor as a propulsion so there is no exhaust gas. In an electric car  the battery used is not just one but more than one so that it can be arranged in series or parallel. Battery should not be used in conditions beyond its limits because it will reduce its life cycle and will be faster to be replaced so that impact on the the cost of maintenance of electric car. Therefore it takes a tool to manage battery usage either during charging or discharging process. Battery Management System (BMS) is an electronic system that function to regulate, monitoring, and protect the battery from conditions that can damage the battery. This BMS can perform balancing process against 20 cells with method cell to cell active balancing, effective current balancing is 24.48 mA in rms. Individual voltage monitoring of cells with an average error is 0.054 V, current charging and discharge readings with an average error is 0.04 A, temperature pack battery reading with an average error is 1.21 ° C. And also battery pack protection system from undervoltage, overvoltage, overheat, and overcurrent conditions is work properly. Keyword: Active Balancing,  battery management system, battery pack

Page 2 of 3 | Total Record : 25


Filter by Year

2018 2018


Filter By Issues
All Issue Vol. 14 No. 1 (2026) Vol. 13 No. 7 (2025) Vol. 13 No. 6 (2025) Vol. 13 No. 5 (2025) Vol. 13 No. 4 (2025) Vol. 13 No. 3 (2025) Vol. 13 No. 2 (2025) Vol. 13 No. 1 (2025) Vol. 12 No. 6 (2024) Vol. 12 No. 5 (2024) Vol. 12 No. 4 (2024) Vol. 12 No. 3 (2024) Vol. 12 No. 2 (2024) Vol. 12 No. 1 (2024) Vol. 11 No. 6 (2023) Vol. 11 No. 5 (2023) Vol. 11 No. 4 (2023) Vol. 11 No. 3 (2023) Vol. 11 No. 2 (2023) Vol. 11 No. 1 (2023) Vol. 10 No. 6 (2022) Vol. 10 No. 5 (2022) Vol. 10 No. 4 (2022) Vol. 10 No. 3 (2022): Vol. 10 No. 3 (2022) Vol. 10 No. 2 (2022) Vol 10, No 2 (2022) Vol 10, No 1 (2022) Vol 9, No 8 (2021) Vol 9, No 7 (2021) Vol 9, No 6 (2021) Vol 9, No 5 (2021) Vol 9, No 4 (2021) Vol 9, No 3 (2021) Vol 9, No 2 (2021) Vol 9, No 1 (2021) Vol 8, No 5 (2020) Vol 8, No 4 (2020) Vol 8, No 3 (2020) Vol 8, No 2 (2020) Vol 8, No 1 (2020) Vol 7, No 7 (2019) Vol 7, No 6 (2019) Vol 7, No 5 (2019) Vol 7, No 4 (2019) Vol 7, No 3 (2019) Vol 7, No 2 (2019) Vol 7, No 1 (2019) Vol 6, No 7 (2018) Vol 6, No 6 (2018) Vol 6, No 5 (2018) Vol 6, No 4 (2018) Vol 6, No 3 (2018) Vol 6, No 2 (2018) Vol 6, No 1 (2018) Vol 5, No 6 (2017) Vol 5, No 5 (2017) Vol 5, No 4 (2017) Vol 5, No 3 (2017) Vol 5, No 2 (2017) Vol 5, No 1 (2017) Vol 4, No 8 (2016) Vol 4, No 7 (2016) Vol 4, No 6 (2016) Vol 4, No 5 (2016) Vol 4, No 4 (2016) Vol 4, No 3 (2016) Vol 4, No 2 (2016) Vol 4, No 1 (2016) Vol 3, No 7 (2015) Vol 3, No 6 (2015) Vol 3, No 5 (2015) Vol 3, No 5 (2015) Vol 3, No 4 (2015) Vol 3, No 3 (2015) Vol 3, No 2 (2015) Vol 3, No 1 (2015) Vol 2, No 7 (2014) Vol 2, No 6 (2014) Vol 2, No 5 (2014) Vol 2, No 4 (2014) Vol 2, No 3 (2014) Vol 2, No 3 (2014) Vol 2, No 2 (2014) Vol 2, No 2 (2014) Vol 2, No 1 (2014) Vol 1, No 5 (2013) Vol 1, No 4 (2013) Vol 1, No 3 (2013) Vol 1, No 2 (2013) Vol 1, No 1 (2013) Vol 1, No 1 (2013) More Issue