Jurnal Fisika FLUX
Jurnal Fisika FLUX is a peer-reviewed, open access journal that publishes original research articles, review articles, as well as short communication in all areas of physics including applied physics, which includes: physics instrumentation and computation, biophysics, geophysics, physics materials, theoretical physics, and physics education. Journal use single peer reviewed to publish. This journal is published by Universitas Lambung Mangkurat Press. ISSN 1829-796X (print) and ISSN 2541-1713 (online)
Jurnal Fisika FLUX is published twice a year. Articles will be peer reviewed first. Once ready to be published immediately on the current edition.
Articles
11 Documents
Search results for
, issue
"Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat"
:
11 Documents
clear
Perbandingan Energi Gempa Bumi Utama dan Susulan (Studi Kasus : Gempa Subduksi Pulau Sumatera dan Jawa)
Andrean V.H Simanjuntak;
Olymphia Olymphia
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (385.574 KB)
|
DOI: 10.20527/flux.v14i1.3776
Indonesia is located on the third meeting of the active tectonic world plates which are Eurasian Indian - Australia and the Pacific Plate. This condition makes Indonesia as a tectonically active area with seismicity level or pattern of high seismicity. Occurrence of devastating earthquake followed by aftershocks of earthquakes, often increase the level of social unrest. The purpose of this study is calculate the energy of devastating earthquakes and followed by aftershocks, so it can be compared to the amount of energy released by both of them. By obtaining these comparisons, the study is based on scientific studies can be used as a reference in providing information on the possible impact of an occurrence of the earthquake and its aftershocks. Empirical formula of Guttenberg- Richter was used to calculate the energy value, historical data with aftershock earthquakes was obtained from ISC (International Seismological Center) for five major earthquakes are Bengkulu, Pangandaran, Simeulue, West Sumatra, and Tasikmalaya earthquake. Earthquake aftershocks taken within three months after a major earthquake. From analysis and energy calculations of earthquake aftershocks of a major earthquake with a magnitude of five large, energy-earthquake aftershocks ranging from 0.1% to 33%, with a random pattern. By comparing the energy aftershocks of earthquakes, the results are generally 10%, it is estimated that the earthquake with strike-slip mechanism having earthquake aftershocks with a total energy is less than 10%. While earthquakes with earthquake aftershocks have thrust mechanism with a total energy of more than 10%.
Analisis Pengaruh Ukuran Pori Terhadap Sifat Listrik Karbon Aktif Dari Limbah Tandan Sawit Pada Prototipe Baterai
Handoyo Margi Waluyo;
Irfana Diah Faryuni;
Abdul Muid
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (278.157 KB)
|
DOI: 10.20527/flux.v14i1.3777
The prototype batteries was succesfully made by using activated carbon. This research aimed to examine the effect of pore size on the electrical properties of activated carbon which is used as a battery-making material. Activated carbon is synthesized using H3PO4 activator with concentration variations (mass/volume) of 5%, 10%, 15%, 20%, and 25%. The carbonization was carried out at 400 °C for 1 hour, while activation at 700 °C for 1 hour. The result showed, the pore size effect on the electrical properties of the activated carbon in the battery prototype, especially for the capacitance and internal resistance of the material which has a correlation of 90% and 90.2%, respectively. The sample with 25% H3PO4 has the best pore size of 5.43μm. As the pore size of the activated carbon increases, it has caused increased capacitance and decreased internal resistance of the material. With the pore size of 5.43μm, the capacitance is 5.88mF/g and the internal resistance of the material is 662.02Ω.
Penerapan Model Learning Cycle 5E untuk Meningkatkan Keterampilan Berpikir Kritis Siswa Pada Materi Fluida Statis Kelas VIII
Irhamna Irhamna;
Haris Rosdianto;
Eka Murdani
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (220.878 KB)
|
DOI: 10.20527/flux.v14i1.3839
Penerapan model learning cycle 5E telah dilakukan pada siswa kelas VIII dengan materi fluida statis. Penelitian ini bertujuan untuk mendapatkan gambaran mengenai peningkatan keterampilan berpikir kritis siswa setelah diterapkan model learning cycle 5E pada materi fluida statis. Bentuk desain penelitian yang digunakan adalah pre-experimental dengan one group pre-test post-test design. Populasi pada penelitian ini adalah seluruh siswa kelas VIII di SMP Torsina Singkawang. Teknik pengambilan sampel menggunakan sampling purposive yang berjumlah 23 orang. Hasil penelitian menunjukkan bahwa model learning cyle 5E dapat meningkatkan keterampilan berpikir kritis siswa yaitu pada indikator pemecahan masalah dengan skor N-gain sebesar 0,43 dengan kategori sedang, indikator membuat keputusan dengan skor N-gain sebesar 0,42 dengan kategori sedang, indikator penyelidikan percobaan dengan skor N-gain sebesar 0,33 dengan kategori sedang dan indikator menyimpulkan dengan skor N-gain sebesar 0,37 dengan kategori sedang.
Pengukuran Kadar Oksigen (O2), Kelembaban dan Temperatur di PT. Perkebunan Nusantara XIII
Diah Ekawati;
Iwan Sugriwan;
Tetti Novalina Manik
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (373.044 KB)
|
DOI: 10.20527/flux.v14i1.3778
Penelitian tentang pembuatan alat ukur kadar oksigen, kelembabn, dan temperatur telah dilakukan. Alat ukur yang dibuat terdiri dari catudaya, penguat tak membalik, sensor oksigen KE-50, modul SHT11, dan modul mikrokontroler ATMega8535. Sensor KE-50 memiliki tegangan keluaran yang positif, nilai tersebut tidak dapat terbaca oleh mikrokontroler, sehingga perlu dikuatkan dengan penguat tak membalik. SHT11 memiliki tegangan keluaran digital dan sudah terkalibrasi oleh pabrik, sehingga SHT11 langsung bisa dihubungkan dengan modul mikrokontroler. Penentuan persamaan karakteristik sensor KE-50 didapatkan dari perkalian tegangan keluaran sensor pada keadaan bebas dengan persamaan karakteristik penguat yang telah dikarakterisasi. Hasil penentuan persamaan karakteristik sensor KE-50 didapatkan persamaan karakteristik tegangan = 39.852x + 0.0117 Volt yang membentuk kurva linier dengan nilai x adalah oksigen. Faktor koreksi pada persamaan karateristik tersebut adalah 0,0117 dan R² = 1. Alat ukur yang dibuat dapat dignakan untuk mengukur kadar oksigen, kelembaban, dan temperatur pada lahan perkebunan kelapa sawit..
Estimasi Resiko Radiasi Janin pada Pemeriksaan Radiografi Pelvis
Giner Maslebu;
Jodelin Muninggar;
Satriya Ary Hapsara
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (294.879 KB)
|
DOI: 10.20527/flux.v14i1.3579
Sinar-X merupakan sumber radiasi pengion yang paling banyak digunakan untuk pemeriksaan diagnostik dalam aplikasi klinik. Radiasi pengion memang memberikan manfaat yang besar dalam pemeriksaan radiodiagnostik, namun paparan radiasi memiliki resiko yang berbahaya sehingga proteksi radiasi terhadap pasien atau pekerja di sekitar daerah smber radiasi perlu diperhatikan, terutama wanita hamil karena berdampak langsung kepada janin. Dalam penelitian digunakan pesawat radiologi planar dengan filter 2 mmAl, solid water phantom dengan ketebalan sebesar 20 cm yang merepresentasikan ketebalan Pelvis, dan Multimeter X-ray untuk pengukuran dosis x-ray pada Focus to Film Distance (FFD) berturut – turut adalah 100 cm, 110 cm, 120 cm, 130 cm, 140 cm dan 150 cm. Pada setiap FFD, digunakan tegangan mulai dari 70 kVp, 73 kVp, 77 kVp, 81 kVp, 85 kVp, 90 kVp hingga 96 kVp pada beban tabung 10 mAs. Penentuan estimasi dosis janin dilakukan dengan menggunakan program Fet.Dose V5. Hasil penelitian menunjukkan bahwa nilai faktor resiko radiasi terhadap janin sebanding dengan tegangan tabung (kVp) dan berbanding terbalik dengan jarak obyek ke sumber radiasi. Untuk satu kali iradiasi dengan pesawat sinar-x dengan pengaturan yang memungkinkan nilai faktor resiko radiasi tertinggi untuk janin diperoleh pada FFD 100 cm dan tegangan tabung 96 kVp sedangkan nilai faktor resiko radiasi terendah diperoleh saat FFD 150 cm dan tegangan tabung 70 kVp.
Modul Perangkat Lunak Monitoring Daya Sel Surya pada Pelacakan Posisi Matahari Harian Menggunakan Delphi
Martha Adelina Sihombing;
Ade Agung Harnawan;
Tetti Novalina Manik
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (466.653 KB)
|
DOI: 10.20527/flux.v14i1.3838
Solar cell power monitoring software module in measurement of current and voltage has been made using data acquisition system device. This module is programmed by Delphi and designed according to the necessities for solar cell monitoring. Necessities for monitoring include many data that will be monitored, i.e: current, voltage, power, time and chart. This module will be integrated with hardware so that the data measured by the hardware can be acquired and displayed by the software module. All monitored data are also displayed through Microsoft Excel which then can be saved. Data acquired from the test are i.e: 0,05 A for current1, 0,2 A for current2, 0,027 V for voltage1, 0,15 V for voltage2, 0,001 W for power1, and 0,004 for power2.
Identifikasi Lapisan Bawah Permukaan yang Terkontaminasi Lindi Sekitar Sistem Sanitary Landfill di TPA Cahaya Kencana, Kabupaten Banjar
Meirani Agustina;
Sri Cahyo Wahyono;
Tetti Novalina Manik
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (445.304 KB)
|
DOI: 10.20527/flux.v14i1.3837
The landfills (TPA) Cahaya Kencana is applying system Sanitary Landfill, the landfill system that is done by the garbage dumped and compacted, then covered with dirt as cover and carried out continuously each end of the operation. This research is very important investigate the distribution of leachate contaminated leachate approximately systems Sanitary Landfill based on the resistivity value and the content of chemical elements in the holding pond. Based on the results of data processing 2D geoelectric Wenner configuration on four tracks with each track length of 100 m were processed using Res2dinv, obtainable at a depth of between 0.75 – 11.6 m resistivity values in the leachate is 4.34 – 10.0 Ωm track 2, 3, and 4, but are not on track 1. The results of laboratory test on four samples consecutive for content. BOD leachate from 26.2 - 121.0 mg/l; and COD 132.5 – 276.2 mg/l is not exceeded the limit of waste water quality standard, except for sample 4 with a COD value of 472.9 mg/l while for pH 7.24 - 7.39 mg/l and the concentration of heavy metals in leachate outlet still on the threshold of normal, where Pb <0.0019 mg/l; Cd <0.0019 mg/l; and Cr <0,0035mg/l.
Desain dan Fabrikasi Alat Ukur Temperatur dan Kelembaban Udara Dalam Tanah Berbasis Mikrokontroler ATMega8535
Arif Hidayat;
Iwan Sugriwan;
Ade Agung Harnawan
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (260.891 KB)
|
DOI: 10.20527/flux.v14i1.3584
Measuring device that used for measuring temperature and humidity inside soil digitally has been realized. The measuring device tested on soil along building foundation with putting SHT11 sensor inside soil using biopory drilling machine. The length of drill is 120 cm with 3, 5 diameter. The sensor is placed 5 cm from the end of the bottom drilling pipe clamped with rubber and styrofoam. In the drilling pipe there is an air hole that function is for air from the soil got into the sensor. The measurement done in 1 day, in each deep 20, 40, 60, 80, 100, and 120 cm. The maximum air temperature inside soil is 27,60C in the depths 120 cm and the minimum is 23,30C in the depths 60 cm. The maximum air humidity inside soil is 96,8 % in the depths of 60 cm and the minimum is 31,4 % in the depths of 100 cm. The data result of measurement is shown on the 16x2 LCD and laptop, using interface software and automatically save the data into Excel and database.
Rancang Bangun Interpreter On Board Diagnosis II(OBDII)
Sukma Firdaus
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (410.912 KB)
|
DOI: 10.20527/flux.v14i1.3779
Telah dibuat interpreter On Board Diagnostic II (OBDII) menggunakan ic ELM 327. Untuk menjalankan ic ELM 327 ini digunakan kristal pembangkit detak sebesar 4.00MHz. Ic ELM 327 mendukung protokol pembacaan OBDII untuk beberapa jenis mobil yang diproduksi oleh perusahaan automotive sejak tahun 1996. Ic ELM 327 terhubung dengan port OBDII yang berada dibawah dashboard sisi pengemudi. Komuniksi interpreter dengan control sistem yang berfungsi sebagai pengirim perintah pembacaan data dan pemprosesan lanjutan menggunakan protokol Universal Asynchronous Receiver/Transmitter(UART). Rancangan Interpreter menggunakan standar J1979 untuk mengakses Parameter Ids (PID). PID yang diakses dalam penelitian ini adalah Throttle Position Sensor, Revolutions Per Minute(RPM) putaran mesin dan suhu kerja mesin yang dibaca melalui suhu cairan pendingin mesin. Untuk dapat membacanya, diperlukan pengaksesan terhadap registryPID. Untuk PIDT hrottle Position Sensoradalah 0x11, PID RPM putaran mesin adalah 0x0C dan untuk PID cairan pendingin mesin adalah 0x05. Dalam pengujian interpreter ini, diperoleh hasil RPM putaran mesin saat itu adalah sebesar 1956 RPM, hasil ini sesuai dengan jarum penunjuk pada panel instrument mobil, untuk persentase valve throttle terbuka sebesar 20% dengan suhu kerja mesin saat itu adalah sebesar 87oC. Dengan diperolehnyarawdata tersebut, menjadikan interpreter ini dapat melakukan proses lanjutan untuk menjadi tools evaluasi dari unjuk kerja mesin atau hanya sebatas data monitoring saja.
Evaluasi Isian Bahan Peledak Berdasarkan groundvibration Hasil PeledakanOverburdenpada PT Bina Sarana Sukses KecamatanSungai Raya Kabupaten Hulu Sungai Selatan Provinsi Kalimantan Selatan
Rusmawarni Rusmawarni;
Nurhakim Nurhakim;
Riswan Riswan;
Ferdinandus Ferdinandus
Jurnal Fisika FLUX Vol 14, No 1 (2017): Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
Publisher : Lambung Mangkurat University Press
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
Full PDF (734.999 KB)
|
DOI: 10.20527/flux.v14i1.3583
PT Bina Sarana Sukses merupakan perusahaan kontraktor tambang batubara yang bekerja melayani operasi produksi untuk PT Antang Gunung Meratus di Pit Warute. Salah satu kegiatan penambangan adalah pengupasan lapisan penutup dengan cara pemboran dan peledakan. Indikator keberhasilan selain tercapainya target produksi peledakan, antara lain fragmentasi dan ground vibration. Dimana ukuran fragmen yang dihasilkan berpengaruh untuk proses penggalian overburden yang terledakkan yang mempengaruhi kinerja alat gali muat dengan tidak mengesampingkan getaran peledakan yang ditimbulkan. Geometri peledakan yang digunakan yaitu burden 8 m x spasi 9 m dengan kedalaman lubang bervariasi antara 5 m sampai 8 m. jarak pengukuran ground vibration 400 m sampai 600 m dari lokasi peledakan. Semakin besar jumlah isian bahan peledak yang digunakan semakin besar pula ground vibration yang dihasilkan, maka jumlah isian bahan peledak harus dikurangi untuk mengurangi ground vibration yang dihasilkan. Alat yang digunakan untuk pengukuran ground vibration adalah Minimate dari Instantel. Metode analisa hasil peledakan menggunakan analisa perbandingan dan regresi. Dari hasil analisa, didapatkan simulasi jumlah isian bahan peledak dengan nilai PPV yang disimulasikan sebesar 2 mm/s. Dengan menggunakan rumus scaled distance maka direkomendasikan jumlah isian bahan peledak pada jarak 400 sebesar 57,45 kg/lubang, jarak 450 m sebesar 72,71 kg/lubang, jarak 500 sebesar 89,76 kg/lubang dan jarak 600 m sebesar 129,26 kg/lubang. Sedangkan dengan menggunakan rumus propagation law maka dapat direkomendasikan jumlah isian bahan peledak pada jarak 400 m yaitu sebanyak 103,04 kg/delay, pada jarak 450 m yaitu sebanyak 130,41 kg/delay, pada jarak 500 m yaitu sebanyak 161 kg/delay dan pada jarak 600 m yaitu sebanyak 231,84 kg/delay.