DESAIN OPTIMAL POWER SISTEM STABILIZER PADA UNIT PEMBANGKIT BAKARU BERBASIS ANT COLONY OPTIMIZATION Djalal, Muhammad Ruswandi; Nawir, Herman; Sonong, Sonong; Marhatang, Marhatang
Transmisi Vol 21, No 3 Juli (2019): TRANSMISI
Publisher : Departemen Teknik Elektro, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (849.978 KB) | DOI: 10.14710/transmisi.21.3.70-78

Abstract

Salah satu peralatan kontrol tambahan yang mampu meningkatkan kestabilan suatu system pada generator adalah Power System Stabilizer (PSS). Ketika terjadi osilasi gangguan pada generator, PSS memberikan sinyal tambahan ke peralatan eksitasi untuk memberikan redaman tambahan pada generator. Penggunaan PSS diperlukan koordinasi penentuan parameter yang tepat untuk mencapai kontrol kinerja yang bagus untuk sistem. Pada penelitian ini, metode kecerdasan buatan algoritma Ant Colony Optimization (ACO) digunakan untuk mengoptimasi parameter PSS. Dari hasil simulasi didapatkan parameter PSS yang optimal ditinjau dari respon osilasi overshoot dan sudut rotor. Kinerja sistem tanpa PSS didapatkan overshoot frekuensi sebesar -0,02242 s/d 0,005241 pu, kemudian PSS dengan Trial error sebesar -0,0196 s/d 0,003704 pu, PSS Bat sebesar -0.01394 s/d 0.0007533 pu, dan dengan metode ant colony didapatkan overshoot yang berkurang yaitu sebesar -0,0128 s/d 0,0003349 pu. Sedangkan untuk respon sudut rotor didapatkan tanpa PSS sebesar -4,71 s/d 4,486e-05 pu, PSS trial error sebesar -4,579 s/d 4,486e-05 pu, PSS Bat sebesar -4.71 s/d 4.486e-05, dan PSS ant colony sebesar -4,566 s/d 4,545e-05 pu. Implementasi metode cerdas sebagai metode penalaan PSS dapat memperbaiki kinerja generator dalam meredam osilasi sistem multimesin.
Electrical Daily Load Forecasting In Ramadhan Using Type-2 Fuzzy Logic In Sulselrabar System Marhatang Marhatang; Muhammad Ruswandi Djalal; Herman Nawir; Sonong Sonong
Lontar Komputer : Jurnal Ilmiah Teknologi Informasi Vol. 9, No. 3 December 2018
Publisher : Institute for Research and Community Services, Udayana University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (327.211 KB) | DOI: 10.24843/LKJITI.2018.v09.i03.p04

Abstract

This study discusses the daily electricity load forecasting 24 hours on 150 kV electric power systems sulselrabar. Forecasting electrical load requires the accuracy of the results with a small error. Peak load forecasting methods used to use smart methods Interval Type-1 Fuzzy Logic (IT1FL) and Interval Type-2 Fuzzy Logic (IT2FL) to predict the needs of the electrical load 1 Ramadan 2016. As input data, it was used load data from 2012 through 2016 for the same day each 1st of Ramadan each year, and as comparative data, it was used actual load data 1, 2016. For the Ramadan input variable, it was used two of the data Variation Load Difference (VLD Max) 2015 as an input variable X, VLD Max 2016 as an input variable Y. From the simulation results obtained highly accurate results where each method produces a very small error, where for methods of using IT1FL of 1.607778264% while using IT2FL by, 1.344510913%.
FIELD-ORIENTED CONTROL PERMANENT MAGNET MOTOR SINKRON MENGGUNAKAN ALGORITMA KUNANG-KUNANG Muhammad Ruswandi Djalal; Andareas Pangkung; Marhatang Marhatang; Sonong Sonong
Jurnal Teknologi Vol 10, No 2 (2018): Jurnal Teknologi
Publisher : Fakultas Teknik Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/jurtek.10.2.153-160

Abstract

Penggunaan kontroler PID (Proporsional-Integral-Derivatif) pada sebuah motor sinkron sangat banyak digunakan, karena strukturnya yang sederhana, kokoh yang kuat dan mudah digunakan. Penggunaan kontroler PID diperlukan pengaturan parameter yang tepat untuk kinerja yang optimal pada motor. Solusi yang sering digunakan adalah metode trial-error, untuk menentukan parameter yang tepat untuk PID, namun hasil yang didapat tidak membuat kontroler PID optimal. Belakangan ini sudah banyak penelitian untuk mengoptimasi kontroler PID, salah dengan metode cerdas. Untuk itu pada penelitian ini akan digunakan metode optimasi Algorithm Firefly, untuk mengoptimasi dan menentukan parameter yang tepat dari PID. FA adalah salah satu metode cerdas yang terinspirasi dari perilaku kunang-kunang yang bergerak dimalam hari dengan kebiasaan berkedip, konsep inilah yang diadaptasi dan diterapkan menjadi algoritma cerdas untuk menyelesaikan masalah optimasi. Dari hasil yang diperoleh metode Firefly dapat dengan baik menala parameter PID. Dari hasil yang memiliki metode firefly dapat dengan baik menala parameter PID, sehingga overshoot yang dihasilkan semakin cepat dan waktu settling sangat cepat. Hasil optimasi Kp 0.7417, Ki 0.3588, Kd 0.1. Overshoot yang dihasilkan masing-masing, tanpa control sebesar 43.33 pu, PID Trial sebesar 30.26 pu, dan PID Firefly sebesar 32.1 pu. 
Penalaan PSS pada Sistem Generator Tenaga Menggunakan Algoritma Penyerbukan Bunga Muhammad Ruswandi Djalal; Sonong Sonong
Jurnal Teknologi dan Sistem Komputer Volume 6, Issue 3, Year 2018 (July 2018)
Publisher : Department of Computer Engineering, Engineering Faculty, Universitas Diponegoro

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (301.021 KB) | DOI: 10.14710/jtsiskom.6.3.2018.93-99

Abstract

This research proposed a tuning method of power system stabilizer (PSS) using an intelligent method based on flower pollination algorithm (FPA) on Pajalesang generator located in Soppeng district. The observed result is the deviation response of velocity and rotor angle in case of disturbance. The case study used as the disturbance to this generator system is a load addition of 0.05 pu. The results show that velocity deviation response without PSS is 0.01152 pu to -0.0248 pu, using PSS trial is 0.007014 pu to -0.02174 pu, using PSS bat algorithm is 0.003972 pu to -0.01865 pu, and using the proposed method of PSS flower algorithm is 0.002149 pu to -0.01678 pu. The rotor angle response shows better results with reduced oscillation and rapidly leading to the steady-state condition. The performance of Pajalesang diesel power plant increased with the installation of FPA PSS, with parameters respectively Kpss=8.5956, T1= 0.0247, T2=0.2484, T3=0.4776, and T4=0.8827.
Rekonfigurasi Jaringan Listrik Penyulang Tawun Rayon Ngawi Dengan Menggunakan Metode Binary Particle Swarm Optimization Muhammad Ruswandi Djalal; Herman Nawir; Sonong
Jurnal Intake : Jurnal Penelitian Ilmu Teknik dan Terapan Vol. 8 No. 1 (2017): April 2017
Publisher : FT- UNDAR

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.48056/jintake.v8i1.22

Abstract

Rekonfigurasi jaringan (Network Reconfiguration) merupakan suatu usaha merubah bentuk konfigurasi jaringan distribusi dengan mengoperasikan pensakelaran terkontrol jarak jauh (switching remotely controlled) pada jaringan distribusi tanpa menimbulkan akibat yang beresiko pada operasi dan bentuk sistem jaringan distribusi secara keseluruhan. Dalam kondisi operasi normal, rekonfigurasi jaringan dilakukan karena dua alasan: mengurangi rugi-rugi daya pada sistem (loss reduction), mendapatkan pembebanan yang seimbang untuk mencegah pembebanan yang berlebih pada jaringan (load balancing). Pada Jarinyan Tegangan menengah Penyulang Tawun Rayon Ngawi terdiri dari 57 bus (GTT) dan 60 saluran. Dari hasil running menunjukkan bahwa sebelum rekonfigurasi memutus switch line 56, 57, 58, 59 dan 60 setelah rekonfigurasi line 26, 27, 42, 47 dan 53. Sebelum rekonfigurasi jaringan mengalami losses sebesar 235.1532 kW setelah rekonfigurasi mengalami losses sebesar 184.1323 kW. Hasil rekonfigurasi dapat mereduksi losses 21.6969 %. Dan tegangan ujung sebelum rekonfigurasi 0,93891 pu menjadi 0.95897 pu
Bat Intelligence For Tunning Power System Stabilizer At Barru Power Plant Muhammad Ruswandi Djalal; Andareas Pangkung; Sonong Sonong; Apollo Apollo
JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA) Vol 2 No 1 (2018): April
Publisher : Muhammadiyah University, Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/jeee-u.v2i2.1276

Abstract

Changes in load on the power system suddenly, can cause dynamic disruption. This disturbance can not be responded well by the generator, so it can affect the system dynamic stability, such as the occurrence of oscillation speed and rotor angle. Conventional control of excitation and governor, also unable to repair the oscillations, so that additional controllers such as Power System Stabilizer (PSS) are required. In the use of PSS, there are several problems that often arise, namely the correct tuning of PSS parameters. In this research, we proposed a method of smart computing based on bat algorithm, for tuning PSS parameters. From the analysis results can be concluded, the performance performance of generator barru increased with the installation of Power System Stabilizer with optimal PSS parameter, with parameters respectively Kpss = 44.0828, T1 = 0.0284, T2 = 0.0146, T3 = 0.7818, T4 = 1.2816.
Rancang Bangun Sistem Pentanahan Penangkal Petir Pada Tanah Basah dan Tanah Kering pada Laboratorium Teknik Konversi Energi Herman Nawir; Muhammad Ruswandi Djalal; Sonong Sonong
JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA) Vol 2 No 2 (2018): October
Publisher : Muhammadiyah University, Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/jeee-u.v2i2.1581

Abstract

Lightning rods in the Laboratory of Energy and Protection Distribution System of Ujung Pandang State Polytechnic are not functioning properly so the resistance resistance tends to be large, this is not good for earthing. This problem can be overcome by remaking lightning rods on wet and dry soils. This activity was carried out to reduce the value of resistance resistance in connection with this, this activity was carried out by designing, assembling and collecting data carried out by testing, while data analysis was carried out by counting. Based on the results of the discussion concluded that the resistance resistance value obtained is smaller than the previous device. Evidenced by the results of the test where the resistance value on the rod electrode in dry conditions ranged from 1.56 to 2.40 Ohm while the previous tool ranged from 1.6 to 9.0 Ohm. Then for wet soil conditions that range from 0.45 to 1.29 Ohm, while the previous tool is around 1.8 - 5.25 Ohm
Rancang Bangun Modul Pembelajaran Bengkel Listrik Sonong Sonong; Herman Nauwir; Muhammad Ruswandi Djalal
JEEE-U (Journal of Electrical and Electronic Engineering-UMSIDA) Vol 3 No 1 (2019): April
Publisher : Muhammadiyah University, Sidoarjo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.21070/jeee-u.v3i1.1924

Abstract

Electric motor is an electric machine that has a function as a converter of electrical energy into mechanical energy. Electric motors are widely used as movers because they are better in terms of technical and economical, but have disadvantages such as large initial currents so that they cannot last long, to overcome this can be used Y-utan star starting method both manually and automatically created in a panel box. In the operation and manufacture of a protection system for a 3 phase induction motor, some supporting equipment can be arranged in a panel box so that motor performance can be maximized. The results of this tool design are in the form of a panel box in which there are three types of circuits, namely: 3 phase induction motor operation circuit with the starting Y-∆ automatically, reversing the direction of 3 phase induction motor rotation, and 3 phase induction motor operation in two places. Where the series is equipped with a protection system and can be operated manually and automatically.
STUDI KEANDALAN SISTEM JARINGAN DISTRIBUSI PRIMER 20 kV BUSBAR PANGKEP Tri Randi Uetama; Aris Saputra; Lewi Lewi; Sonong Sonong
Jurnal Teknik Mesin Sinergi Vol 11, No 2 (2013): Oktober 2013
Publisher : Politeknik Negeri Ujung Pandang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (243.183 KB) | DOI: 10.31963/sinergi.v11i2.1109

Abstract

Seiring dengan bertambahnya jumlah beban pada busbar Pangkep maka performa pelayanan semakin kompleks. Maka dari pada itu diperlukan sebuah studi untuk menganalisis keandalan pada busbar Pangkep untuk melihat indeks keandalannya. Hal ini sangat penting untuk diketahui dan juga menjadi referensi bagi PT PLN (persero) untuk meningkatkan atau mempertahankan kualitas listriknya. Penelitian ini dilakukan dengan mengambil data gangguan, durasi pemadaman dan jumlah pelanggan kemudian dihitung laju kegagalan dan lama gangguan rata-rata konsumen selama setahun yaitu tahun 2011. Hasil perhitungan tersebut digunakan untuk menentukan indeks keandalan yaitu SAIFI, SAIDI, CAIFI, CAIDI, ASAI dan ASUI dan dinyatakan dalam angka. Dari hasil perhitungan diperoleh bahwa ketersediaan energi listrik busbar Pangkep masih di atas 90 % dan SAIFI dengan nilai 0,87241 gangguan/pelanggan/tahun dan SAIDI dengan nilai 25,60979 menit/pelanggan/tahun. Maka indeks keandalannya masih berada dalam batas-batas yang diperbolehkan PT PLN (persero) dengan nilai SAIFI maksimal adalah 3,166 gangguan/pelanggan/tahun dan SAIDI adalah 137 menit/pelanggan/tahun. Sesuai dengan SPLN 59 tahun 1985, yang menyatakan bahwa keandalan distribusi ditinjau dari indeks frekuensi dan durasi gangguan, dan juga standar IEEE (Institute Of Electrical and Electronic Enginering) yang menyatakan bahwa suatu jaringan distribusi dikatakan andal jika mampu menyediakan energi listrik 90 % ke atas dalam kurun waktu yang ditentukan. Sehingga dapat dikatakan sistem jaringan distribusi 20 kV busbar Pangkep masih andal. Untuk memudahkan hasil perhitungan indeks keandalan maka digunakan program Matlab 2010. Agar kontinuitas pelayanan tetap terjaga indeks keandalan masih bisa ditingkatkan lagi dengan lebih memperhatikan perawatan menggunakan standarisasi perawatan yang lebih disiplin dan managemen perawatan yang baik.
Pembangkitan Tegangan Tinggi Bolak Balik Menggunakan Kumparan Tesla Sonong Sonong
Jurnal Teknik Mesin Sinergi Vol 9, No 1 (2011): April 2011
Publisher : Politeknik Negeri Ujung Pandang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (202.468 KB) | DOI: 10.31963/sinergi.v9i1.1066

Abstract

Kumparan tesla merupakan alat yang mampu menghasilkan tegangan tinggi mulai dari ribuan volt sampai jutaan volt. Tegangan tinggi yang dihasilkan oleh kumparan tesla adalah tegangan tinggi bolak-balik dengan frekuensi berkisar antara puluhan kilohertz sampai dengan orde MHz. Tegangan keluaran kumparan tesla berbentuk pulsa dengan lebar pulsa bervariasi dari nano detik sampai ratusan mikro detik. Pada awal perkembangannya, kumparan tesla menggunakan sela bola untuk membangkitkan pulsa tersebut. Perkembangan selanjutnya kumparan tesla lebih banyak dikembangkan dengan teknologi semikonduktor untuk menggantikan fungsi sela bola. Selain mudah dalam pengaturan lebar pulsa, teknologi semikonduktor juga lebih ringkas dan praktis. Pada makalah ini akan dibahas perancangan kumparan tesla yang menggunakan inverter frekuensi tinggi dengan range frekuensi antara 150–800 KHz. Untuk mengukuran tegangan keluaran kumparan tesla digunakan sela bola standar.