Claim Missing Document
Check
Articles

Found 12 Documents
Search

Efisiensi Daya Protokol Quantize and Forward Pada Sistem Komunikasi Kooperatif Multi-relay Nasaruddin Nasaruddin; Rony Kurnia; Ramzi Adriman
Jurnal Rekayasa Elektrika Vol 13, No 1 (2017)
Publisher : Universitas Syiah Kuala

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.17529/jre.v13i1.6568

Abstract

One of effective diversity techniques to combat fading on wireless channel is a cooperative communication system in which a source sends information through several relays and then forward it to a destination. A cooperative communication system has shown increased the system performance and reduced the energy consumption. However, it depends on the used relay mechanism that is relay protocols such as quantize and forward (QF) and amplify and forward (AF). In the previous research, energy efficiency of AF relay has investigated for a single-relay cooperative system, but multi-relay is more practical. Therefore, this research focuses on power efficiency in multi-relay cooperative communication system using QF protocol. The research method used is mathematical analysis and computer simulation for outage probability and power efficiency in the multi-relay QF. Simulation result found that multi-relay QF system could provide a high power efficiency, but the efficiency is reduced when the distance ratio increases. Power efficiency can be increased by adding the number of relays in the system. A comparison of power efficiency for QF and AF protocols has simulated, in which power efficiency of multi-relay QF is higher than that of multi-relay AF at distance ratio and power transmit. Thus, multi-relay QF system can provide high performance and power efficiency in the cooperative communication system.
Sympathetic Trip Analysis in Distribution System of PLTU and PLTA Nagan Raya Muhammad Mizwar; Tarmizi Tarmizi; Ramzi Adriman
Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro Vol 8, No 1 (2024)
Publisher : PTE FTK UIN Ar-Raniry

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22373/crc.v8i1.19791

Abstract

At the PT unit, PLN (Persero), there is an issue with the 20 kV electric power distribution system, such as feeder disruption. As a result, many felt sorry for the feeders of PLTA Krueng Isep and PLTU Nagan Raya, whose consumers were without power for extended periods of time. Of course, it can impact how well a business performs, particularly in terms of service and electrical revenue. In order to examine the causes of Sympathetic, study is required. In order to conduct the research, data on disturbances are gathered, tests are run, simulation results are analyzed using the ETAP application, non-directional relays are swapped out for directional relays, protection coordination is reset, and evaluation is done. The findings of this study have the potential to improve performance at PT. PLN (Persero) and decrease or even completely eradicate the incidence of sympathy in the 20 kV distribution network.