Claim Missing Document
Check
Articles

Found 27 Documents
Search

Sistem Kontrol Suhu dan Kelembapan pada Kandang Iguana Hijau Berbasis IoT Cloud Zen, Nur Afifah; Rifai, Muhammad; Maulana, Yulian Zetta; Permatasari, Indah
Science Tech: Jurnal Ilmu Pengetahuan dan Teknologi Vol 10 No 2 (2024): Agustus
Publisher : Universitas Sarjanawiyata Tamansiswa

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30738/st.vol10.no2.a17418

Abstract

One type of lizard that is popular in Indonesia is the green iguana, which belongs to the Iguanidae family. Green iguanas are cold-blooded animals that often sunbathe to adjust their body temperature to the same as the environmental temperature so that the iguana's digestive system can be optimal. Therefore, green iguana lovers or breeders need an IoT-based maintenance solution. This research aims to design a green iguana cage that can maintain temperature and humidity automatically using a DHT22 sensor. Based on test results, the IoT-based temperature and humidity control system in the green iguana cage was proven to be effective in maintaining environmental conditions in the cage. On the 1st day of testing, the average temperature and humidity sensor errors in the system design at three different times were 1.03% and 2.24%, respectively. Furthermore, on day 2, the average temperature and humidity sensor errors were 1.359% and 1.739% respectively. This system works effectively, where the humidifier maintains humidity by obeying the limits of turning off at humidity above 80% and turning on below 70%. Meanwhile, the light adjusts its brightness level based on temperature with a range of 30°C - 35°C. This system is able to maintain temperature and humidity with 97% accuracy. The results of the tested data are sent to the IoT Platform so that they can be accessed in real-time. The test results for the delay value of 90.45441238 ms indicate that data transmission is in the very good category.
Optimasi Dosis Mata dan Kualitas Citra Menggunakan Shielding pada Pencitraan CT-Scan Kepala Irmayatul Hikmah; Aditya Prayugo Hariyanto; Nur Afifah Zen; Sevia Indah Purnama
Jurnal Teori dan Aplikasi Fisika Vol. 11 No. 1 (2023): Jurnal Teori dan Aplikasi Fisika
Publisher : Department of Physics, Faculty of Mathematics and Natural Sciences, University of Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/jtaf.v11i1.332

Abstract

Implementasi Teknologi Pengusir Burung Otomatis untuk Petani Padi Desa Muntang Muhammad Panji; Nur Afifah Zen; Prasetyo Yuliantoro; Shinta Romadhona; Dodi Zulherman
El-Mujtama: Jurnal Pengabdian Masyarakat  Vol. 6 No. 2 (2026): El-Mujtama: Jurnal Pengabdian Masyarakat 
Publisher : Intitut Agama Islam Nasional Laa Roiba Bogor

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.47467/elmujtama.v6i2.11424

Abstract

Farmers in Muntang Village, Kemangkon, Purbalingga, face substantial crop losses due to bird attacks during the ripening stage of rice cultivation. Conventional deterrents such as scarecrows and hanging cans have become ineffective as birds have adapted to their static nature. This community engagement initiative implements an automatic, solar-powered bird-repellent system combining ultrasonic sensors, servo-driven mechanical noise elements, and electronic buzzers. The stages included system design, component procurement, device assembly, field installation, farmer training, and performance evaluation. Two units were successfully deployed in the rice fields, demonstrating effective responses to bird movement. More than twenty farmers participated in hands-on training and increased their understanding of appropriate agricultural technology. Initial field observations indicated reduced bird intrusion, improved crop protection, and enhanced labor efficiency. This initiative contributes to food security at the village level and supports the adoption of simple smart-farming innovations in rural agricultural settings.
Effect of phantom orientation angle on antenna sensor response in agar-based homogeneous phantom for abnormal breast tissue detection Rachma Cherlly Pramata; Irmayatul Hikmah; Muntaqo Alfin Amanaf; Nur Afifah Zen
Jurnal Teknokes Vol. 19 No. 2 (2026): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v19i2.160

Abstract

Breast cancer remains a major global health concern; therefore, early detection plays a crucial role in reducing its mortality rates. Conventional imaging techniques, such as mammography, have limitations including ionizing radiation exposure and reduced sensitivity in dense breast tissues. Microwave-based sensing has emerged as a promising alternative due to its non-ionizing nature, relatively low cost, and sensitivity to dielectric property contrasts between normal and malignant tissues. This study aims to investigate the effect of phantom orientation angle on the response of an antenna-based microwave sensor for abnormal breast tissue detection. An agar-based homogeneous breast phantom is utilized, with tumor inclusion modeled as regions of different dielectric properties. Measurements are conducted using a Vector Network Analyzer (VNA) over a frequency range of 2–6 GHz, with four orientation angles (0°, 90°, 180°, and 270°). The reflection coefficient (S11) is analyzed to observe variations in electromagnetic response under different conditions. The results indicate that tumor presence causes measurable shifts in resonance frequency and variations in the reflection coefficient (S11). Larger tumors produce greater frequency shifts due to higher dielectric contrast. Furthermore, the orientation angle significantly affects detection sensitivity, which is attributed to the antenna radiation pattern and spatial interaction between electromagnetic waves and the phantom. In conclusion, this study demonstrates that both tumor size and phantom orientation influence antenna sensor response. The novelty of this work lies in the incorporation of orientation-based analysis, providing new insight into spatial electromagnetic interactions and enhancing the potential of microwave sensing systems for accurate and non-invasive breast cancer detection.
Preliminary Study of Using KY-038 Sensor Based on Arduino UNO and LabView to Determine the Pulse Rate: Nur Afifah Zen, Slamet Indriyanto, Indah Permatasari, Juwansyah Sasmita, Lia Yuliantini Nur Afifah Zen Nur Afifah Zen; Slamet Indriyanto Slamet Indriyanto; Indah Permatasari Indah Permatasari; Juwansyah Sasmita Juwansyah Sasmita; Lia Yuliantini Lia Yuliantini
Jurnal Fisika dan Aplikasinya Vol 16 No 2 (2020): June 2020 Edition
Publisher : Lembaga Penelitian dan Pengabdian Kepada Masyarakat, LPPM-ITS

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12962/j24604682.v16i2.6092

Abstract

The KY-038 sensor module is designed using Arduino UNO and LabView to allow human pulses. The experiment was carried out by making a design consisting of the KY-038 sensor module, Arduino UNO and LabView on a computer. LabView software is used to display pulse wave patterns. Measurement of the pulse will involve human objects with variations 3 namely relax (sit), sit and after running in place. The experimental results show that the different activities affect the voltage released on a chart that has a rating of 3 - 3.5 V. The more activities that are carried out before retrieving the pulse data, the greater the voltage that is read on the LabView results graph. After running in place, the value of the voltage and pulse are 3.5 V and 97 beats per minute, respectively.
Analysis of the Effect of Abnormal Tissue Size on the S11 Response of a Monopole Antenna Using a Realistic Heterogeneous Breast Phantom Isma Hanifah; Irmayatul Hikmah; Nur Afifah Zen; Muntaqo Alfin Amanaf
Jurnal Teknokes Vol. 19 No. 2 (2026): June
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jteknokes.v19i2.159

Abstract

Breast cancer remains one of the leading causes of death among women. Although conventional diagnostic methods are available, they are limited by radiation exposure risks, high operational costs, and limited accessibility. Alternatively, microwave technology offers the advantage of using non-ionizing radiation and leveraging differences in dielectric properties between healthy and abnormal tissues. The development of this technology, however, requires experimental validation using phantoms capable of realistically and stably representing the dielectric characteristics of biological tissues. In this study, a heterogeneous breast phantom was developed to evaluate antenna sensitivity in detecting variations in the size of abnormal tissue through S11 parameter analysis. The contribution of this study is the fabrication of a four-layer phantom (skin, fat, glandular, and abnormal tissue) using agar–gelatin materials. Sodium benzoate was added as a preservative to prevent microbial growth, and NaCl was incorporated to adjust the conductivity, enabling dielectric properties closer to those of real breast tissue. In the testing phase, two variations of abnormal tissue with diameters of 4 cm and 6 cm were inserted into the glandular layer to simulate different pathological conditions. The S11 response was measured using a vector network analyzer (VNA) over the 2–6 GHz frequency range with a monopole antenna placed 1 cm from the phantom. The results showed that the antenna sensor could detect differences between normal phantoms and phantoms with anomalies, particularly in the 2.5–3 GHz range. The normal phantom showed the lowest resonant frequency at 2.51 GHz with a return loss of −36.35 dB. In contrast, phantoms with 4 cm and 6 cm abnormal tissues showed shifts to 2.52 GHz (−29.71 dB) and 2.53 GHz (−28.69 dB), respectively. A maximum return loss difference of approximately 7.66 dB was observed, indicating high sensitivity to internal structural changes. These significant differences in return loss values indicate that the developed system is highly sensitive to changes in internal structure. This combination of a heterogeneous phantom and an antenna sensor has the potential to serve as a simple experimental platform to support breast cancer detection technology.
Utilization of Biomass as a Carbon Source for The Synthesis of Graphene as a Sustainable Materials Innovation Dina Rahmawati; Melda Taspika; Nur Afifah Zen
Sustainability: Theory, Practice and Policy Vol. 1 No. 2 (2021): Sustainability: Theory, Practice and Policy December Edition
Publisher : Pusat Kajian Berkelanjutan UIN Sulthan Thaha Saifuddin Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30631/sdgs.v1i2.1015

Abstract

One of the alternative ways to reduce the use of fossil fuels is the advancement of energy storage devices and energy conversion devices for renewable energy. The electrode is an essential part of its electrochemical performance in energy storage. The specific surface area of the electrode will affect the energy density, lifetime, charging, and discharging of the energy storage devices. Graphene has been widely used for energy storage, such as batteries and supercapacitors. Generally, graphene is synthesized from graphite as a carbon source which some researchers have reported. However, they are still fighting against simple synthesis methods, low-cost raw materials, eco-friendly co-product, and large-scale production. Therefore, advanced research is required to bring graphene from laboratory-scale projects to industry. One of the best solutions is biomass as a raw material to replace graphite in synthesizing graphene. In this review, some methods for synthesizing graphene from biomass will explain briefly, following with their strength and weakness.