Claim Missing Document
Check
Articles

Found 38 Documents
Search

Optimalisasi Performa Sistem Tegangan dengan Pemasangan Kapasitor Bank pada Pembangkit Listrik Tenaga Uap (PLTU) Nagan Raya Syukri, Mahdi; Suriadi; Sara, Ira Devi; Siregar, Ramdhan Halid; Muhibbuddin; Masri
Journal of Engineering and Science Vol. 2 No. 1 (2023): January-June 2023
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/jes.v2i1.165

Abstract

This research aims to optimize the performance of the voltage system at the Nagan Raya Steam Power Plant (PLTU) by installing capacitor banks. Capacitor banks are integrated into the system to increase voltage stability, reduce power losses, and increase energy efficiency in PLTUs. The research method involves analyzing the existing voltage system, designing the capacitor bank installation, and evaluating the system performance after installation. It is hoped that the results of this research can make a positive contribution in improving the performance of PLTU Nagan Raya and overall energy efficiency.
Fatigue Analysis on Hybrid Sugar Palm-Kenaf Fibre Reinforced Polypropylene Composites Bachtiar, Dandi; Siregar, Januar Parlaungan; Zulfadhli; Masri; Arhami; Siregar, Ramdhan Halid; Jalil, Saifuddin Muhammad
Journal of Engineering and Science Vol. 3 No. 1 (2024): January-June 2024
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/jes.v3i1.209

Abstract

ABSTRACT Hybrid natural-natural fibre reinforced polymer composites become attractive alternative to seek the friendly-environmentally materials. Study on the durability level of the hybrid composites have the importance reason due to the role in application as structural function. This study focuses on examining the fatigue strength of polypropylene polymer composites reinforced with hybrid sugar palm-kenaf fibres. The hybrid composite materials were prepared by mixing the fibres and matrix with several compositions. There are five composition types of specimens that evaluated, such as 70:10:10, 70:15:15, 70:20:10, 80:10:10 and 90:5:5. The hybrid composites were composed by PP, sugar palm fibre and kenaf fibre. Furtheremore the tensile test were conducted to find the value of ultimate tensile strength for every specimens of hybrid composites. The fatigue test also were conducted with four level of stress i.e. 80%, 70%, 60% and 50%. The results show that in the lower level of stress, the hybrid composites with higher content of sugar palm fibre posses the better performance of fatigue life compare to the others
Pelatihan Instalasi Sistim Listrik Tenaga Surya kepada Santri Dayah Mini Banda Aceh Syukri, Mahdi; Suriadi; Ramdhan Halid Siregar; Syahrizal; Alfisyahrin
Kawanad : Jurnal Pengabdian kepada Masyarakat Vol. 1 No. 1 (2022): March
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/kjpkm.v1i1.44

Abstract

Utilization of solar energy as a generator of electrical energy is growing. One of technology for the use of solar energy is to use solar panels to generate electricity. Solar panels can be installed on the roof of the house to meet electricity on a household scale. The current challenge is the lack of trained personnel who have the competence to install solar panels on the roof of the house. So it is considered it is important to educate skilled workers through solar power installation training. For this purpose, training activities for solar electricity installation are carried out for Dayah Mini Banda Aceh students through an independent community service program. This training aims to train workers to gain Panel installation competence Sun on the Roof of the House. Solar Panel Installation Practice Method is done by simulating installation of equipment ranging from solar panels, inverters, charge controllers and charging battery. The results to be achieved with the practice of installing solar panels so that students have Skills in installing rooftop solar panels.
Sosialisasi Peralatan Kelistrikan dan Pengambilan Keterangan untuk Mengungkapkan Sebuah Kasus di Kepolisian Resort Pidie Sebagai Ahli Elektro Siregar, Ramdhan Halid; Suriadi; Syukri, Mahdi; Syahrizal; Syukriyadin; Away, Yuwaldi; Alfisyahrin
Kawanad : Jurnal Pengabdian kepada Masyarakat Vol. 1 No. 2 (2022): October
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/kjpkm.v1i2.57

Abstract

Electricity is very useful for human life. However, if an error in use results in a danger to the safety of humans, livestock and property. Sometimes electricity is also used for special purposes for which there are no guidelines, this will be very risky to safety. As in the case that occurred recently in the Pidie Resort Police area, the Head of the Pidie Resort Police assigned his members for the benefit of the police service in the context of the task of carrying out an examination of electrical experts to obtain information regarding the discovery of a body in the mountain river of Gampong Lhok Broh, Meureudu District, District Pidie Jaya. The expected objectives of this activity are; So that participants can understand the benefits of electrical energy and the basic principles, operation, and maintenance of electrical equipment, Provide participants with knowledge (in general) about how to work and maintain electrical equipment that may be designed and used in a community environment, Demonstrate directly the dangers of some related electrical equipment cases currently being handled by the police. This activity was carried out from October 1 to November 30 2019 and consisted of 3 stages namely; Preparation, Execution, and Compilation of Reports. Based on inspections and field trials in two places, the following conclusions can be drawn; Electric current is dangerous for the human body depending on the amount of current and duration. The effect of electric current on humans starts with tingling/numbness to effect the heart which can cause death. Water is a conductor that can carry electric current properly. The safe voltage limit for humans is 50 Volt AC assuming the human body is 1000 Ohm resistant, the safe current limit for humans is 30 mA. The dedicated team also as electrical experts discusses scientific about matters related to electrical hazards and their effects on the human body.
Pelatihan Merencanakan Dan Memasang Panel Surya Di Rumah Hunian Lubis, Rakhmad Syafutra; Siregar, Ramdhan Halid; Walidainy, Hubbul; Putra, T. Edisah; Masri
Kawanad : Jurnal Pengabdian kepada Masyarakat Vol. 3 No. 1 (2024): March
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/kjpkm.v3i1.184

Abstract

The community engagement conducted by the lecturers of the Electrical Engineering undergraduate program at the Faculty of Engineering, Syiah Kuala University, aims to enhance the income of young individuals in Kopelma Darussalam, Banda Aceh. Recognizing the need for employment opportunities among youths from lower to middle-income backgrounds, this initiative focuses on providing hands-on skills through training in planning and installing solar panels in residential homes. Consequently, young individuals can become skilled workers in solar panel installation, creating job opportunities, and improving their economic well-being. This training aims to address the increasing demand for renewable energy solutions and the growing interest in solar power adoption among homeowners. Participants will learn about the principles of solar energy, site assessment, system design, installation techniques, and safety procedures. After completing the training, participants are expected to be able to design and install solar panel systems, thereby contributing to the promotion of sustainable energy practices and reducing carbon footprint in residential communities.
Program Pelatihan Pemasangan Instalasi Listrik Gedung dan Daya bagi Pemuda Kopelma Darussalam Lubis, Rakhmad Syafutra; Siregar, Ramdhan Halid; Walidainy, Hubbul; Syukri, Mahdi; Jalil, Saifuddin Muhammad
Kawanad : Jurnal Pengabdian kepada Masyarakat Vol. 3 No. 2 (2024): October
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/kjpkm.v3i2.225

Abstract

The Training Program on Building Electrical and Power Installation for Kopelma Darussalam Youth is designed to enhance the technical skills of the younger generation in the electrical field. This program aims to equip participants with both theoretical knowledge and practical experience related to the installation of electrical systems in buildings, including lighting systems and power distribution networks. The training covers topics such as the introduction to electrical components, installation planning, installation techniques, safety standards, and troubleshooting electrical systems.The primary target of this program is local youth with potential to develop technical competence in the electrical sector, enabling them to compete in the workforce or establish independent businesses. By employing a project-based approach, participants are expected to apply their skills professionally and in compliance with industry standards. Furthermore, this program contributes to empowering youth as valuable community assets to support sustainable local development.
Optimalisasi Performa Sistem Tegangan dengan Pemasangan Kapasitor Bank pada Pembangkit Listrik Tenaga Uap (PLTU) Nagan Raya Syukri, Mahdi; Suriadi; Sara, Ira Devi; Siregar, Ramdhan Halid; Muhibbuddin; Masri
Journal of Engineering and Science Vol. 2 No. 1 (2023): January-June 2023
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/jes.v2i1.165

Abstract

This research aims to optimize the performance of the voltage system at the Nagan Raya Steam Power Plant (PLTU) by installing capacitor banks. Capacitor banks are integrated into the system to increase voltage stability, reduce power losses, and increase energy efficiency in PLTUs. The research method involves analyzing the existing voltage system, designing the capacitor bank installation, and evaluating the system performance after installation. It is hoped that the results of this research can make a positive contribution in improving the performance of PLTU Nagan Raya and overall energy efficiency.
Small-Scale Wind Power Generator with Inverse Taper and Taper Type Blades at Low Wind Speed Lubis, Rakhmad Syafutra; Muhayatsyah, Teuku; Syukri, Mahdi; Siregar, Ramdhan Halid; Jalil, Saifuddin Muhammad
Journal of Engineering and Science Vol. 4 No. 1 (2025): June
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/jes.v4i1.275

Abstract

The utilization of wind energy as one of the renewable energy sources in Indonesia is still limited. This is due to Indonesia's large wind potential, but it is at low speeds. One modification of wind turbines to overcome this problem is by using inverse taper and taper blades. Inverse taper blades have a chord distribution that increases from root to tip while taper blades have a chord distribution that decreases from root to tip. This research conducts the design and construction of inverse taper and taper blades on small-scale wind turbines using NACA 6412 airfoil type, then tested in the field and obtained the performance of each blade. The design was carried out using blade element momentum theory to obtain the blade geometry shape and perform performance analysis of each type of blade. Based on the simulation results obtained from QBlade, it shows that the inverse taper blade performance has a maximum Cp of 0.52 while the taper blade has a maximum Cp of 0.41. The power graph from field testing results shows that inverse taper blades provide good power generation at low wind speeds compared to taper blades. The inverse taper blade has a cut-in speed of 1.2 m/s and the best power production occurs at speeds of 1-4 m/s.
Transformer Oil Failure Analysis Based on Dissolved Gas Analysis (DGA) Test Using Breakdown Voltage and Fuzzy Logic Methods Lubis, Rakhmad Syafutra; Akbar, Muhammad Hafizh; Siregar, Ramdhan Halid; Masri, Masri
Journal of Engineering and Science Vol. 4 No. 2 (2025): December
Publisher : Yayasan Kawanad

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56347/jes.v4i2.381

Abstract

A common problem that occurs in transformers is failure of the insulating oil. One solution to prevent this disruption is to analyze indications of insulating oil failure. Several previous studies on the analysis of transformer insulating oil failure were based on dissolved gas content tests of transformer oil samples. The research was conducted using several methods in processing dissolved gas test results data, such as the TDCG (Total Dissolved Combustible Gas), Roger's Ratio, and Duval's Triangle methods. In this study, two methods were used for comparison, namely the Breakdown Voltage method and the Fuzzy Logic method. The results obtained show that the condition of the insulating oil using fuzzy logic in the Matlab simulation is in accordance with the condition of the transformer insulating oil based on its breakdown voltage characteristics, namely in a normal state. Meanwhile, gas content that is at a high or very high level has a significant impact on the indication of failure in transformer insulating oil, namely the concentration of TDCG and nitrogen gas content.
Particle Swarm Optimization-Based Recloser Placement for Reliability Improvement in the Kuala ULP Distribution System Ramdhan Halid Siregar; Ardiansyah Putra Karo; Syahrizal
Indonesian Journal of Technical and Vocational Education Training Vol. 2 No. 2 (2025): DECEMBER 2025
Publisher : MANDAILING GLOBAL EDUKASIA

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.62945/ijtvet.v2i2.853

Abstract

In an electric power distribution system, one of the things that needs to be considered is the reliability of the electric power system. Currently, the location of the recloser is very important for the reliability of the power system. The parameters used for network reliability are the SAIFI and SAIDI values. The SAIFI and SAIDI values can be determined based on the failure time and failure rate in one year. The smaller the SAIFI and SAIDI values, the better the reliability. The purpose of this study is to determine the best recloser position on the MG 03 ULP Kuala feeder grid, Langkat Regency. The method chosen in determining the research location uses particle swarm optimization (PSO) by implementing MATLAB R2021a software. The simulation results show that the reliability before and after reinstallation has changed. SAIFI and SAIDI before reintegration are 1.2495 hours/customer/year and 3.3555 times/customer/year, respectively.