Analysis of the Potential for Savings in Electrical Energy Consumption in Lifts: Case Study in Indonesia Deni Almanda; Anwar Ilmar Ramadhan
Journal of Applied Sciences and Advanced Technology Vol 3, No 1 (2020): Journal of Applied Sciences and Advanced Technology
Publisher : Faculty of Engineering Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/jasat.3.1.29-34

Abstract

Regenerative Drive is a motor drive system in an elevator that can also generate electrical energy while consuming electrical energy in the elevator machine, Regenerative Drive converts gravitational potential energy into electrical energy by utilizing the operating characteristics of the lift and the weight difference between the lift cage and the load balancing (Counterweight). ). The resulting regenerative power is recovered by returning to the building electricity and being used in other electrical equipment. Regenerative drive lift test location is located in Building which has an elevator using Regenerative Drive. With a motor power of 38.6 kW and can produce regenerative power of 29 kW.
Studi Analisa Penyebab Kerusakan Kapasitor Bank Sub Station Welding di PT. Astra Daihatsu Motor Deni Almanda; Nurkholis Majid
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 2, No 1 (2019): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (519.494 KB) | DOI: 10.24853/resistor.2.1.7-14

Abstract

Penggunaan kapasitor bank salah satu fungsinya adalah sebagai alat untuk meningkatkan factor daya. Factor daya yang diijinkan standard PLN adalah >0,85. Penggunaan kapasitor bank tidak lepas dari adanya gangguan kerusakan. Kerusakan yang terjadi pada kapasitor bank antara lain kapasitor meledak, kapasitor terbakar dan fuse kapasitor putus. Apabila kerusakan ini tidak segera ditangani maka akan menimbulkan biaya yang besar dalam perbaikannya, untuk itu perlu adanya penanganan lebih lanjut agar biaya yang dikeluarkan untuk perbaikan tidak terlalu besar. Banyaknya kerusakan yang terjadi antara lain diakibatkan oleh beban non linier yang dapat menyebabkan gelombang harmonic. Pengukuran THD (Total Harmonic Distortion) yang dilakukan dapat mendeteksi besarnya gelombang harmonic yang terjadi pada jaringan distribusi listrik. Pengukuran harmonic ini meliputi THD-U (tegangan) dan THD-I (Arus) sesuai dengan standar internasional yang diijinkan.  Disisi lain kapasitor bank yang dijual di pasaran ada beberapa tipe antara lain kapasitor kering (dry) dan kapasitor basah (oil). Perbedaan dari kedua kapasitor ini ada pada bahan dielektrik yang digunakan kapasitor tersebut. Kualitas dalam pemilihan jenis kapasitor bank juga dapat berdampak pada umur dari kapasitor itu sendiri.
Studi Pemilihan Sistem Pendingin pada Panel Surya Menggunakan Water Cooler, Air Mineral dan Air Laut Deni Almanda; Doddy Bhaskara
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 1, No 2 (2018): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (896.425 KB) | DOI: 10.24853/resistor.1.2.43-52

Abstract

Permasalahan utama dari solar cell adalah perbedaan jenis solar cell yang mengakibatkan perbedaan kinerja pada solar cell tersebut. Besarnya daya keluaran yang dihasilkan relatif tidak konstan karena dipengaruhi oleh besarnya intensitas matahari  serta  suhu  lingkungan  di  sekitarnya.  Untuk mengatasi masalah tersebut maka penelitian ini dirancang untuk melakukan perbandingan panel surya monocrystalline jenis vertikal dan jenis fleksibel.Dari hasil pengujian dan analisa dengan simulasi pencahayaan matahari langsung menggunakan sistem pendingin panel surya fleksibel menghasilkan efisiensi lebih baik dibanding panel surya vertikal, yaitu 20.40%, sedangkan panel surya vertikal menggunakan heatsink, yaitu 16.75%. Dari hasil pengujian dan analisa dengan simulasi pencahayaan lampu menggunakan sistem pendingin heatsink panel surya vertikal menghasilkan efisiensi lebih baik dibandingkan dengan panel surya vertikal, yaitu 17.39%, sedangkan panel surya fleksibel menggunakan heatsink sebesar 15.30%. Dari hasil pengujian dan Analisa dengan simulasi pencahayaan matahari langsung dengan system tanpa pendingin heatsink telah didapatkan hasil Analisa atau percobaan bahwa panel surya fleksibel menghasilkan efisiensi yang lebih baik dibandingkan panel surya vertikal, yaitu 19.39%, sedangkan panel surya vertikal mempunyai efisiensi 18.55%. dari hasil percobaan dan Analisa dengan simulasi pencahayaan lampu tanpa menggunakan system pendingin heatsink dari hasil percobaan dan Analisa telah didapatkan bahwa panel surya vertikal menghasilkan efisiensi yang lebih baik dari pada panel surya fleksibel, yaitu 18.50%, sedangkan panel surya fleksibel menghasilkan efisiensi sebesar 17.37%.
Sistem Pengingat Ganti Oli Berdasarkan Running Hours Mesin, Lama Waktu Pemakaian dan Kekentalan Oli pada Mesin Wire Drawing Berbasis Raspberry Pi 1 Riza Samsinar; Deni Almanda; Eko Priatna
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 2, No 2 (2019): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (737.219 KB) | DOI: 10.24853/resistor.2.2.121-130

Abstract

Pada perkembangan teknologi saat ini perusahaan - perusahaan semakin gencar untuk mendatangkan  mesin - mesin dengan teknologi – teknologi cangih dan modern,  sehingga perusahaan pun semakin ketat untuk dapat menghasilkan produk – produk dengan kualitas dan mutu yang baik dan tepat sasaran serta efektif dan efesien. Untuk mencapai itu semua perlu adanya perawatan terhadap mesin – mesin produksi agar performa mesin produksi tetap terjaga dengan baik, salah satu perawatan mesin adalah dengan cara mengganti oli secara berkala dengan ditambahkan sistem pengingat ganti oli berdasarkan running hours mesin, lama waktu pemakaian dan kekentalan oli pada mesin wire drawing berbasis raspberry pi. Ada 3 parameter pada sistem pengingat ganti oli yaitu: berdasarkan running hours, lama waktu pemakian dan kekentalan oli, dari tiga parameter tersebut jika salah satu atau semua sudah mencapai parameter seting yang ditentukan disetiap oli, maka oli di nyatakan tidak layak pakai dan harus segera diganti, dan semua parameter dan hasil dapat dilihat pada LCD dan buzzer sebagai penanda bunyi jika oli sudah harus segera diganti. Dengan adanya pergantian oli secara berkala maka kerusakan – kerusakan mesin yang di akibatkan gearbox mesin yang pecah dapat dihilangkan, sehingga mesin dapat menghasilkan produk – produk yang berkualitas dan tidak menimbulkan downtime mesin yang dapat menggangu aktifitas produksi secara efektif dan efesien.
Analisis Pengaruh Kompensasi Impedansi Urutan Nol (Kzn) terhadap Kehandalan Sistem Proteksi Rele Jarak (Distance Relay) pada Penghantar Harapan Indah di Gardu Induk Plumpang Deni Almanda; Juniyanto Juniyanto
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 4, No 1 (2021): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.4.1.1-6

Abstract

Pada saat terjadi gangguan hubung singkat di saluran transmisi Gardu Induk Plumpang, rele jarak berfungsi sebagai proteksi utama. Penelitian ini bertujuan untuk mengetahui pengaruh kompensasi impedansi urutan nol (kzn) terhadap kehandalan sistem proteksi rele jarak (distance relay) pada penghantar harapan indah di Gardu Induk Plumpang. Setting rele jarak yang didapatkan dari PT PLN (Persero) UPT Pulogadung disimulasikan menggunakan alat uji Omicron. Hasil simulasi gangguan hubung singkat satu fasa, gangguan hubung singkat dua fasa, dan gangguan hubung singkat tiga fasa menggunakan setting lama Z1 = 2.58 Ω, Z2 = 3.87 Ω, dan Z3 = 7.30 Ω, kZn = 0.93 Ω < -0.4° rele jarak tidak bekerja selektif, maka dilakukan resetting. Hasil resetting rele jarak yaitu Z1 = 2.58 Ω, Z2 = 3.87 Ω, dan Z3 = 7.30 Ω, kZn = 0.68 Ω < -0.6°. Setelah dilakukan resetting dan disimulasikan gangguan hubung singkat satu fasa, gangguan hubung singkat dua fasa, dan gangguan hubung singkat tiga fasa, rele jarak bekerja secara handal. Kesimpulannya kZn dapat mempengaruhi kehandalan sistem proteksi rele jarak pada penghantar harapan indah di Gardu Induk Plumpang.In the event of a short circuit in the transmission line of the Plumpang Substation, the distance relay serves as the main protection. This study aims to determine the effect of zero sequence impedance compensation (kzn) on the reliability of the distance relay protection system at the Harapan Indah conductor at the Plumpang Substation. The distance relay setting obtained from PT PLN (Persero) UPT Pulogadung was simulated using the Omicron test tool. Simulation results of single phase short circuit, two phase short circuit, and three phase short circuit using the old setting Z1 = 2.58 Ω, Z2 = 3.87 Ω, and Z3 = 7.30 Ω, kZn = 0.93 < -0.4° relay distance does not works selectively, then resetting is done. The results of resetting the distance relay are Z1 = 2.58 Ω, Z2 = 3.87 Ω, and Z3 = 7.30 Ω, kZn = 0.68 < -0.6°. After resetting and simulating single-phase short circuit, two phase short circuit, and three phase short circuit fault, the distance relay works reliably. In conclusion, kZn can affect the reliability of the distance relay protection system on the beautiful hope conductor at the Plumpang Substation.
Evaluasi Pemasangan Current Transformer Ring Tipe Clamp On yang Berfungsi Sebagai Pengaman Line Differential dan Circulating Current Protection Deni Almanda; Muhammad Isroqi Radifan
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 5, No 1 (2022): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.5.1.1-6

Abstract

 Gangguan pada Gardu Induk Ancol, terjadi karena benang layangan yang mengakibatkan hubung singkat Fasa T terhadap ground pada SUTT Ancol-Angke. Gangguan ini terjadi karena malfungsi pada sistem proteksi GIS Priok Timur bay Ancol . Gangguan diketahui dengan mengnalisa relai pada GI Ancol dan GIS Priok Timur sehingga diketahui besarnya arus gangguan, relai yang terpasang yaitu micom P543. Dari hasil perhitungan dapat dilihat arus gangguan pada sirkit Ancol- Angke sebesar 92kA dan juga sirkit Priok Timur- Ancol sebesar 17kA. Selanjutnya dilakukan pengecekan pada rangkaian sekunder current transformer dan pengujian kualitas current transformer. Dalam investigasi  di temukan arus yang tidak seimbang pada rangkaian skunder current transformer disebabkan karena pemasangan current transformer yang tidak sesuai dan temukan juga rangkaian leadsheat yang membuat arus sekunder semakin bertambah.However, at the same time, the differential relay and circulating current protection on the East Priok GIS read the Phase T short circuit to the ground which resulted in a trip on the Ancol bay 1. In the investigation, no anomalies were found in the Priok Timur - Ancol circuit, so it can be concluded that there is a malfunction in the system. protection of GIS Priok Timur Ancol Bay. In analyzing the disturbance, it is done by downloading the relay on GI Ancol and GIS Priok Timur to find out the magnitude of the fault current, the relay installed is the micom P543. From the download results, it can be seen that the fault current in the Ancol-Angke circuit is 92kA and also the Priok Timur-Ancol circuit is 17kA.  
Analisa dan Perbandingan PLTS on Grid yang Terpasang di Atap Gedung Utama PT Subur Semesta dengan Plts On Grid yang Bergerak Mengikuti Arah Matahari Deni Almanda; Moh Akhsin Zaenal Muttaqin
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 3, No 2 (2020): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.3.2.57-60

Abstract

Berdasarkan Permasalahan kebutuhan listrik di kalangan industri maka energi surya di pilih sebagai salah satu energi alternatif untuk menghasilkan energi listrik. Energi surya yang di hasilkan di siang hari bisa membuat penghematan daya berdasarkan cara pemasangan modul surya, pemakaian inverter yang sesuai dan instalasi standar yang terpasang. Pemasangan modul surya di atap gedung dengan pemasangan yang mengikuti arah matahari sangat berpengaruh pada energi listrik yang di hasilkan maka dari itu memaksimalkan keluaran listrik dari modul surya sangat di perlukan. Based on the problem of electricity demand in the industry, solar energy is chosen as an alternative energy to produce electrical energy. Solar energy generated during the day can make power savings based on how to install solar modules, use the appropriate inverter and standard installation installed. Installation of solar modules on the roof of the building with an installation that follows the direction of the sun is very influential on the electrical energy produced, therefore maximizing the electrical output of the solar module is very necessary.
Analisi Pembangkit Listrik Tenaga Mikrohidro Menggunakan Sistem Distribusi Air di P.T. Astra Honda Motor Plant 5 Karawang Deni Almanda; Rahmat Kartono
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 3, No 1 (2020): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (725.78 KB) | DOI: 10.24853/resistor.3.1.1-8

Abstract

Energi listrik dan merupakan salah satu kebutuhan vital yang tidak bisa dipisahkan bagi masyarakat pada umumnya maupun perusahaan industri khususnya. Maka dari itu mendorong pelaku usaha untuk melakukan suatu pengolahan energi yang beretujuan meningkatkan efisiensi energi dan juga mencari sumber energi yang terbarukan seperti air, angin, surya dan lain-lain.Pembangkit Listrik Tenaga Mikrohidro (PLTMH) merupakan salah satu energi listrik alternatif yang mempunyai beberapa kelebihan diantaranya tidak memakai bahan bakar dan sumber energi didapat dengan gratis. Menurut Larasakti (2012:245) jadi pada prinsipnya dimana ada air mengalir dengan ketinggian minimal 2,5 meter dengan debit 250 liter/detik, maka disitu ada energi listrik.Pada Pembangkit Listrik Tenaga Mikrohidro (PLTMH) PT Astra Honda Motor menggunakan generator dengan output 1100 watt serta sumber energi memanfaatkan aliran sirkulas air cooling tower dengan debit 2000 lpm serta head total 7 meter. Berdasarkan data tersebut didapatkan potensi energi sebesar 1152,82 watt. Pada aktualnya PLTMH menghasilkan energi sebesar 950,4 watt. Berdasarkan data tersebut dapat kita simpulkan bahwa PLTMH tersebut hanya menghasilkan 83,16% dari kapasitasnya.
Analisis Kebutuhan Motor Listrik Untuk Meningkatkan Efisiensi Waktu Tunggu Elevator Deni Almanda; Ilham Taqwa Ramadhan
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 4, No 2 (2021): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24853/resistor.4.2.91-96

Abstract

Semakin berkembangnya ilmu pengetahuan dan teknologi serta banyaknya Gedung bertingkat pada zaman sekarang ini, mengakibatkan alat transportasi vertikal atau yang biasa dikenal dengan nama elevator/lift sangat dibutuhkan sebagai sarana transportasi pada Gedung bertingkat. Elevator atau lift digunakan untuk mengefisiensikan waktu, jarak tempuh, dan tenaga bagi pengguna untuk menuju setiap lantai dalam gedung. Penelitian ini menggunakan beberapa metode antara lain study literature, observasi, interview. Speed lift ditentukan berdasarkan waktu tunggu lift yang dibutuhkan pada Gedung bertingkat dan mengacu pada data SNI, sehingga diharapkan akan mempermudah dalam menganalisisnya. Dari hasil analisis untuk meningkatkan efisiensi waktu tunggu lift perlu menghitung ulang kebutuhan motor listrik yang digunakan, karena motor listrik sebagai mesin utama penggerak lift dan alat pengangkut beban sehingga besarnya daya motor listrik akan sangat mempengaruhi kapasitas orang yang di angkut dan waktu tempuhnya. Dengan speed lift yang disarankan 4 m/s akan mempersingkat waktu tunggu lift sebesar 12%, waktu perjalanan bolak-balik 11%, meningkatnya daya angkut 13% dan membutuhkan kapasitas daya motor listrik sebesar 39,5 kW.The development of science and technology as well as the number of high-rise buildings in this day and age, resulted in vertical transportation equipment or commonly known as elevators / elevators are needed as a means of transportation in high-rise buildings. Elevators or lifts are used to streamline the time, distance, and energy for users to get to each floor in the building. This study uses several methods including literature study, observation, interviews. The lift speed is determined based on the waiting time for the lift required in a multi-storey building and refers to SNI data, so it is hoped that it will make it easier to analyze it. From the results of the analysis to improve the efficiency of the elevator waiting time, it is necessary to recalculate the need for the electric motor used, because the electric motor is the main engine driving the elevator and the load-carrying tool so that the magnitude of the electric motor power will greatly affect the capacity of the people being transported and the travel time. With the recommended speed lift of 4 m/s, it will shorten the lift waiting time by 12%, the round trip time by 11%, the increase in carrying capacity by 13% and requires an electric motor power capacity of 39.5 kW.
Audit Energi Listrik Pabrik Deni Almanda; Bayu Kusuma
RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer) Vol 1, No 1 (2018): RESISTOR (Elektronika Kendali Telekomunikasi Tenaga Listrik Komputer)
Publisher : Universitas Muhammadiyah Jakarta

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (502.762 KB) | DOI: 10.24853/resistor.1.1.25-34

Abstract

Audit energy adalah teknik yang digunakan untuk menghitung besarnya konsumsi energi pada suatu gedung dan mengetahui cara-cara untuk penghematan. Audit energy merupakan aktifitas berkala untuk mengetahui ada tidaknya penyimpangan dalam suatu kegiatan menelusuri dimana dan berapa energi yang digunakan, mengidentifikasikan ketidakseimbangan beban yang menimbulkan losses secara teknis serta mengevaluasi tingkat kelayakan. Adapun tujuan analisa ini adalah untuk mengevaluasi kualitas daya terhadap pengaruh faktor daya, unbalance load dan harmonisa akibat sistem mengkonsumsi beban secara tidak seimbang dan juga beban yang bersifat non-linear serta dampak yang ditimbulkannya terhadap sistem, dengan mengacu pada standar Institute of Electrical and Elecronic Engineers (IEEE) 519.1992.