Claim Missing Document
Check
Articles

Found 33 Documents
Search

ANALISA KINERJA FAKTOR KEBERHASILAN SISTEM MANAJEMEN LINGKUNGAN KEGIATAN INDUSTRI MINYAK DENGAN PENDEKATAN INTEGRATED ENVIRONMENT PERFORMANCE MEASUREMENT SYSTEM (IEPMS) – AHP Reiza Fandrio Abrori; Katharina Oginawati; Priana Sudjono
Jurnal Teknik Lingkungan Vol. 24 No. 1 (2018)
Publisher : ITB Journal Publisher, LPPM ITB

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/j.tl.2018.24.1.6

Abstract

Abstrak: Sistem manajemen lingkungan menjadi fokus utama dalam upaya melindungi lingkungan saat ini. Untuk itu diperlukan analisa kinerja faktor keberhasilan dalam implementasi sistem manajemen lingkungan pada lingkup perusahaan agar dapat menjadi sebuah penilaian dan pengukuran terhadap faktor yang sudah baik atau terdapat faktor yang perlu dilakukan pembenahan. Daerah penelitian yang ditinjau adalah perusahaan Migas yang telah memiliki sistem manajemen lingkungan, atau bahkan telah mendapat sertifikasi ISO 14001. Ditetapkan beberapa faktor kinerja yang akan ditentukan dengan pendekatan Integrated Environment Performance Measurement System (IEPMS) dalam mengidentifikasi Key Enviromental Performance Indicator (KEPI). Untuk menyusun hierarki model dan mendapatkan bobot setiap KEPI digunakan Analytic hierarchy process (AHP) dalam mengolah data kuesioner perbandingan berpasangan sehingga dapat ditentunkan bobot kepentingan KEPI. Untuk selanjutnya dapat dilakukan pengukuran dengan menggunakan Objective Matrix (OMAX) dalam penilaian tingkat kinerja perusahaan dalam melakasanakan Sistem Manajemen Lingkungan. Dapat disimpulkan bahwa perusahaan memiliki kinerja yang baik dalam melaksanakan sistem manajemen lingkungan ISO 14001 dengan faktor yang paling berpengaruh adalah kebijakan lingkungan perusahaan serta keuntungan yang paling dirasakan adalah meningkatkan kepercayaan pelanggan. Kata kunci: Sistem Manajemen Lingkungan, Integrated Environment Performance Measurement System, ISO, ISO 14001, AHP, Lingkungan berkelanjutan Abstract: Environmental management systems are the main focus of efforts to protect the environment today. It is necessary to analyze the performance of success factors in the implementation of environmental management system on the scope of the company in order to become an assessment and measurement of factors that are good or there are factors that need improvement. The research areas reviewed are oil and gas companies that already have an environmental management system, or even have received ISO 14001 certification. Several performance factors will be determined by the Integrated Environment Performance Measurement System (IEPMS) approach in identifying Key Enviromental Performance Indicator (KEPI). To compile the model hierarchy and get the weight of each KEPI used Analytic hierarchy process (AHP) in processing the data paired comparison questionnaire so that it can be weighted the importance of KEPI. For further measurement using Objective Matrix (OMAX) in the assessment of company performance level in carrying out Environmental Management System. Company has a good performance in implementing the environmental management system ISO 14001 with the most influential factor is the company's environmental policy and the most perceived advantage is to increase customer confidence. Keywords: Environmental Management System, Integrated Environment Performance Measurement System , ISO, ISO 14001, AHP,Sustainable environments
ANALISIS RISIKO DENGAN METODE HAZARD AND OPERABILITY STUDY (HAZOPS) DALAM PENENTUAN SAFETY INTEGRITY LEVEL (SIL) BERBASIS RISK GRAPH DAN QUANTITATIVE METHOD PADA UNIT BOILER PT X Badrun Ahmad; Katharina Oginawati
Jurnal Teknik Lingkungan Vol. 25 No. 2 (2019)
Publisher : ITB Journal Publisher, LPPM ITB

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/j.tl.2019.25.2.4

Abstract

Abstrak: Boiler beroperasi pada temperatur dan tekanan tinggi sehingga memiliki risiko ledakan. Untuk itu boiler memiliki sistem kontrol untuk mengendalikan bahaya temperatur dan tekanan tinggi menggunakan Safety Instrumented Systems (SIS). Tujuan penelitian ini untuk mengetahui Safety Integrity Level (SIL) yang menunjukan kinerja dari SIS pada boiler PT X. Penelitian ini dimulai dengan menganalisis risiko menggunakan metode hazard operability study (Hazops) untuk mendapatkan skor risiko. Hasil analisis metode Hazops menunjukkan skor risiko tertinggi pada unit boiler final superheater dan reheater sebesar 25, sedangkan skor risiko evaporator, low temperatur superheater, dan platen superheater sebesar 20. Skor tertinggi ini dikategorikan critical, sehingga risiko tidak dapat diterima dan pengendalian harus secepatnya dilakukan. Risiko terendah pada economizer dengan skor 10. Penentuan SIL menggunakan dua metode yaitu metode risk graph dan metode kuantitatif. Analisis dengan metode risk graph pada SIS unit boiler economizer menunjukkan kontrol dapat dilakukan secara manual. Sedangkan penentuan SIL pada evaporator dan low temperatur superheater menghasilkan SIL 1. Analisis risk graph pada unit boiler platen superheter, final superheater, dan reheater menghasilkan SIL 2 di semua SIS pada 3 unit ini. Penentuan SIL secara kuantitatif pada platen superheater dan final superheater menghasilkan SIL 1. Unit reheater menghasilkan SIL 2. Ini menunjukkan perlu adanya peningkatan dari SIL 1 menjadi SIL 2 pada platen superheater dan final superheater dengan mengubah desain safety instrumented function dan mengurangi waktu kalibrasi dari 1 tahun menjadi 6 bulan. Kata kunci: boiler, hazops, sil, risk graph, quantitative method Abstract: Boiler operated at high temperatures and pressures so it has a risk of explosion. Therefore, the boiler has an automatic control system to minimize the hazard of high temperatures and pressures using Safety Instrumented Systems (SIS). The purpose of this research is to determine Safety Integrity Level (SIL) which is the performance of SIS. This research begins to analyze risk using the hazard operability study method (Hazops) to get a risk score. The results of the Hazops method analysis showed the highest risk score on the final superheater and reheater boiler units of 25, while the evaporator score, the superheater low temperature, and the superheater platen were 20 categorized as critical so control must be done as soon as possible. The lowest risk on economists with a score of 10. SIL determination uses two methods are the risk graph method and the quantitative method. Analysis uses the risk graph method on the SIS boiler economizer unit shows that control can be done manually. While SIL on evaporator and low temperature superheater results SIL 1. Risk graph analysis on the superheter platen boiler unit, final superheater, and reheater produces SIL 2 in all SIS in these 3 units. Quantitative determination of SIL on the platen superheater and final superheater shows SIL 1. The reheater unit shows SIL 2. The results of the analysis indicate that there is an increase from SIL 1 to SIL 2 on the platen superheater and final superheater by changing the safety instrumented function design and reducing calibration time from 1 year to 6 months. Keywords: boiler, hazops, sil, risk graph, quantitative method 
The Pollution Profile of Citarik, Cimande, and Cikijing Rivers in Rancaekek District, West Java, Indonesia Refnilda Fadhilah; Katharina Oginawati; Nur Aisyah Yuniar Romantis
INDONESIAN JOURNAL OF URBAN AND ENVIRONMENTAL TECHNOLOGY Volume 2, Number 1, October 2018
Publisher : Universitas Trisakti

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1280.15 KB) | DOI: 10.25105/urbanenvirotech.v2i1.3551

Abstract

Aim: The objective of this study was to determine the heavy metals pollution profile of Citarik, Cimande, and Cikijing Rivers. Methodology and Result: The method of this research to measured heavy metals was cadmium, chromium, copper and zinc. Determination of sampling point refers to SNI 03-7016-2004. The river water sampling procedure refers to SNI 6989.57-2008 on Water and Wastewater - Section 57. The water sample extraction method refers to Standard Method for the Examination of Water and Wastewater. Sediment sample extraction method refers to EPA Method 200.2-1994. The water sample extraction method refers to Standard Method for the Examination of Water and Wastewater. Sediment sample extraction method refers to EPA Method 200.2-1994. Based on test result and comparison to quality standard of Indonesian Government Regulation No. 82of 2001 on Water Quality Management and Water Pollution Control. The metal concentrations in the sediments were much higher than the concentrations of metals contained in water. This is due to the accumulation of metals in sediments that occur continuously. Conclusion, significance and impact study: The concentrations of four metals in water and sediments after river points higher than before passing the industrial area, it indicates that anthropogenic arising from agricultural activities and textile industry near the rivers of Citarik, Cikijing, and Cimande rivers. The degree of contamination and seasonal variation of heavy metals were high in water and sediment.
Performance Improvement Strategy Sustainable Domestic Wastewater Treatment Installation (Case Study: Sanimas Neglasari Village, Sayati Village and Cipaku Village, Bandung Regency) Imtiyaz Olaf Jatmy; Katharina Oginawati
Budapest International Research and Critics Institute-Journal (BIRCI-Journal) Vol 5, No 3 (2022): Budapest International Research and Critics Institute August
Publisher : Budapest International Research and Critics University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33258/birci.v5i3.6839

Abstract

The West Java Provincial Government has inaugurated a community-based sanitation program in 18 Bandung districts. Especially in the Citarum river basin, domestic waste contributes 68% to river pollution and has a water quality status for the last 10 years, showing 54% heavily polluted, 23% moderately polluted, 20% lightly polluted and only 3% meet the quality standards. . Efforts to improve the control of domestic wastewater pollution require the selection of technology which is influenced by many factors, so a theoretical and practical approach is needed that pays attention to the sustainability aspect. Neglasari Village, Banjaran Sub-district, Sayati Village, Margahayu Sub-district and Cipaku Village, Paseh Sub-district, are sub-districts in Bandung Regency that have implemented the Sanimas program that has not met the muku standard so that it is necessary to improve the performance of a sustainable Sanimas wastewater treatment plant. Of the three locations of the Sanimas wastewater treatment plant spread from upstream of the river, the location of the Sanimas wastewater treatment plant is in a densely populated area and an area prone to sanitation, also has a need for handling sanitation problems. This research was conducted using the SWOT method. SWOT analysis is carried out to obtain priority strategy recommendations.
Strategies for Improving the Performance of Sustainable Domestic Wastewater Treatment Plants Imtiyaz Olaf Jatmy; Katharina Oginawati
Journal of Social Research Vol. 2 No. 3 (2023): Journal of Social Research
Publisher : International Journal Labs

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55324/josr.v2i3.712

Abstract

The West Java Provincial Government has inaugurated a community-based sanitation program in 18 Bandung Regencies. Especially in the Citarum watershed, domestic waste contributes 68% to river pollution and has water quality status over the past 10 years, showing 54% heavily polluted, 23% moderately polluted, 20% lightly polluted, and only 3% meeting quality standards. Efforts to improve domestic wastewater pollution control require the selection of technology that is influenced by many factors, so a theoretical and practical approach that pays attention to sustainability aspects is needed. Neglasari Village, Banjaran District, Sayati village, Margahayu district, and Cipaku village, Paseh District, are Kcamatan in Bandung Regency who have run the Sanimas program that has not met the muku standards, so it is necessary to improve the performance of the Sanimas wastewater treatment plant that is sustainable. From the location of the S animal wastewater treatment plant spread from the upper reaches of the river, the location of the Sanimas wastewater treatment plant is in a densely populated area and sanitation-prone area, also has the need to deal with sanitation problems. This research was conducted using the SWOT method. A SWOT analysis is performed to obtain recommendations for priority strategies.
Association between Blood Lead Levels and Heme Synthesis Process in Paint Industry Workers Sharnella Janet Yapfrine; Katharina Oginawati; Sonia Buftheim; Yuyun Ismawati
Eduvest - Journal of Universal Studies Vol. 3 No. 5 (2023): Journal Eduvest - Journal of Universal Studies
Publisher : Green Publisher Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59188/eduvest.v3i5.813

Abstract

Lead is a heavy metal that can pose various health risks to humans. One of the effects of lead exposure is the inhibition of the delta-ALAD enzyme which plays a role in the heme synthesis process. Blood lead levels and delta-aminolevulinic acid dehydratase (ALAD) activity are considered biomarkers of lead exposure and lead toxicity respectively. The inhibition of ALAD can cause in accumulation of ALA in urine and also inhibit the heme synthesis pathway that plays a role in hemoglobin production. The present study was designed to investigate the association between the BLLs and the heme synthesis process, which is detected by the accumulation of urinary ALA (ALA-U) and decreasing hemoglobin, in paint industry workers from Indonesia. A total of 52 paint industry workers participated in this study. Blood lead was measured using ICP-MS and ALA-U was measured using spectrophotometer method. Mean blood lead was 4.213±1.6 mg/L; and 17 workers (32.7%) crossed the recommended level of 5 mg/L. Mean urinary ALA level was 3.712±2.5 mg/L; and 11 workers (11.54%) crossed the normal level of 6 mg/L but still classified as acceptable. Mean hemoglobin level was 15.273±1.03 g/L. The correlation between the BLL and ALA-U was found to be positive but not significant. Meanwhile, the correlation between the ALA-U and the hemoglobin levels was found to be negative but also not significant.
Penyediaan Air Bersih dan Renovasi Toilet di Pantai Oetune dan Pantai Kolbano, Nusa Tenggara Timur Oginawati, Katharina; Gunrady, Rudy; Sriharyuniwati, Iwuk; Fahimah, Nurul; Qiara Fildzah Yanetta; Doharta, Prastita; Sharnella Janet Yapfrine
International Journal of Community Service Learning Vol. 7 No. 3 (2023): Agustus
Publisher : Universitas Pendidikan Ganesha

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23887/ijcsl.v7i3.55422

Abstract

Penelitian ini dilatarbelakangi oleh potensi besar wisata bahari di Pantai Oetune, Desa Tuafanu, Kecamatan Kualin, dan Pantai Kolbano, Desa Kolbano, Kecamatan Kolbano, yang terbatas oleh kurangnya fasilitas akses air bersih dan sanitasi yang memadai. Tujuan utama dari program pengabdian ini adalah untuk meningkatkan fasilitas penunjang wisata di kedua lokasi ini, memberikan manfaat bagi masyarakat setempat dan wisatawan, serta berkontribusi pada pencapaian Sustainable Development Goals (SDGs) terkait akses air bersih dan sanitasi yang layak. Program pengabdian ini mengambil bentuk penyediaan akses air bersih melalui instalasi pompa submersible, generator set, dan reservoir di Desa Tuafanu, Kecamatan Kualin, serta perbaikan empat toilet di Desa Kolbano, Kecamatan Kolbano, dengan memasang jamban leher angsa dan kubikel yang lebih layak. Subjek yang terlibat dalam program ini adalah masyarakat lokal yang tinggal di sekitar Pantai Oetune dan Pantai Kolbano, serta tim pengabdian yang terdiri dari dosen dan mahasiswa dari Institut Teknologi Bandung (ITB). Metode pelaksanaan program melibatkan survei awal untuk menilai kebutuhan, diskusi kelompok, dan implementasi lapangan. Hasil utama dari program ini adalah peningkatan signifikan dalam fasilitas akses air bersih dan sanitasi di kedua lokasi wisata. Program ini juga menciptakan peluang yang lebih baik bagi wisatawan untuk menikmati pengalaman yang nyaman dan memadai selama kunjungan mereka. Secara lebih luas, program ini berkontribusi pada upaya pencapaian target SDGs terkait akses air bersih dan sanitasi yang memadai, serta memberikan contoh bagaimana kolaborasi antara perguruan tinggi dan masyarakat lokal dapat memberikan dampak positif dalam pembangunan wilayah.
Relationship between Lead Exposure and Genotoxic Effect in Paint Industry Workers Rahman, Intan Nur’azizah; Oginawati, Katharina; Ismawati, Yuyun; Buftheim, Sonia; Nugrahaningsih, Dwi Aris Agung
Devotion : Journal of Research and Community Service Vol. 4 No. 7 (2023): Devotion: Journal of Research and Community Service
Publisher : Green Publisher Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59188/devotion.v4i7.517

Abstract

Lead-based paint is a main source of lead exposure to paint industry workers and causes an imbalance of Reactive Oxygen Species (ROS) and antioxidants, causing a genotoxic effect. Pb in the blood (PbB) level and DNA damage are frequently used as exposure and effect biomarker of lead. The purpose of this study to determine the relationship between PbB level and DNA damage due to occupational lead exposure in paint industry workers. The research design uses a cross-sectional epidemiological study involving 52 workers from three paint manufacturers in Indonesia. Blood samples were taken for PbB analysis using ICP-MS, while DNA damage was analyzed using the Comet Assay method. The PbB average obtained was 4.36±1.60 µg.dL-1, where 17 workers (32.69%) exceeded the safe limit value of PbB (5 µg.dL-1). Meanwhile, the influential factors of PbB are the working period and alcohol consumption (p=0.029). The level of DNA damage was represented as Tail DNA (%), and the average was 9.62±0.19 %. All respondents in this study were categorized as under low damage (Class 2). There was no significant relationship between PbB and Tail DNA (%) and has a negative correlation (p=0.878; r=-0.022). The study concludes that there was no difference in Tail DNA (%) between PbB ≥ 5 µg.dL-1 and PbB < 5 µg.dL-1 (p=0.876). It means that lead exposure in this finding has not reached a level that can significantly cause DNA damage. However, it is necessary to monitor PbB levels in workers to minimize genotoxic or other effects.
Analysis of Human Error Potential as a Cause of Work Accident using Sherpa and Heart Method in The Cement Industry Maulidya, Annisa; Oginawati, Katharina; Suharyanto, Suharyanto
Journal of World Science Vol. 2 No. 9 (2023): Journal of World Science
Publisher : Riviera Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58344/jws.v2i9.408

Abstract

This study was conducted to analyze the potential for human error that can cause workplace accidents in the cement industry of PT.X. The study was conducted by conducting observations, interviews, and distributing questionnaires in the mining area and production area. Questionnaires were distributed to 96 people who were mining heavy equipment operators and production operators. The research method used through Human Reliability Analysis with the Hierarchial Task Analysis (HTA) method, knowing the types of errors that occur using the SHERPA method, then calculating the probability of human errors that occur with the HEART method. Based on the results of research using the SHERPA method, the most common types of errors in mining areas and production areas are action errors (60,25%). The type of error that occurs is due to negligence in using personal protective equipment and the work process is not completed properly. Based on research using the HEART method, the greatest opportunity for human error in the mining department is cleaning with dozer with a value of 1,056 and in the production department is in the area of cleaning work with a value of 1,89. Based on the error producing conditions questionnaire (EPCs) for workers in the mining department the most common cause of error is poor equipment / instruments while for workers in the production department is a mismatch between the imagined risk and the actual risk. The recommendations given to companies are to improve work equipment, improve visual displays and provide an appropriate assessment checklist.
Occupational Risk Factors of Carpal Tunnel Syndrome on Workers: A Literature Review Amin, Fauziah; Oginawati, Katharina
Journal of World Science Vol. 2 No. 10 (2023): Journal of World Science
Publisher : Riviera Publishing

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.58344/jws.v2i10.442

Abstract

The median nerve at the wrist becomes crushed in a condition known as carpal tunnel syndrome (CTS), which causes pain, numbness, and tingling in the worker's hand's palm. Risk elements for CTS include things like uncomfortable body posture at work, repetitive hand motions, and vibration exposure. Reviewing prior research on the connection between CTS and potential risk factors such worker hand posture, exposure to hand-arm vibrations, and repetitive hand movements is the goal of this study. The research approach involves searching for relevant articles using the terms carpal tunnel syndrome AND (occupational risk factors OR uncomfortable posture OR hand-arm vibrations OR repeated hand movements) in databases like ScienceDirect, PubMed, ResearchGate, and Scopus. The study indicates that Carpal Tunnel Syndrome is related to repetitive hand movements, hand-arm vibrations, and awkward hand posture during work. This research implies the importance of awareness about occupational safety. Additionally, the study suggests that job designs considering repetitive hand movements, vibrations, and incorrect posture can reduce the risk of Carpal Tunnel Syndrome. Therefore, it is hoped that organizations and workers can collaborate to create a safer, healthier, and more productive work environment.