Claim Missing Document
Check
Articles

Found 20 Documents
Search

ANALISIS KEMAMPUAN PROBLEM SOLVING KONSEP FISIKA PADA MATERI IMPULS MOMENTUM PADA SISWA SMA MUHAMMADIYAH 1 DEMAK Nurhayati, Titik
EduFisika: Jurnal Pendidikan Fisika Vol 6 No 2 (2021): Edufisika: Jurnal Pendidikan Fisika Volume 6 Nomor 02, Desember 2021
Publisher : Program Studi Pendidikan Fisika FKIP Universitas Jambi

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59052/edufisika.v6i2.13512

Abstract

This study aims to analyze the problem solving skills of class X students of SMA Muhammadiyah 1 Demak in the academic year 2020-2021. In this study, there were 13 students who had taken the impulse momentum material. This study used an instrument in the form of essay questions consisting of 5 questions, 3 types of conceptual questions and then 2 questions in the form of arithmetic or mathematical questions. The data were analyzed using the method of describing the results of students' answers which led to indicators of problem solving abilities which included the ability to identify problems, the ability to define and represent problems, the ability to explore strategies, the ability to apply strategies, and the ability to evaluate solutions. The results of this study are in the form of students' problem solving abilities on the physics concepts contained in the momentum impulse material. From the results of the answer analysis, the tenth grade students of SMA Muhammadiyah 1 Demak are good at solving problems but in wording they are still not right. With the results of this study, it is necessary to develop problem-solving skills in class X students of SMA Muhammadiyah 1 Demak.
The Measurement of the Medical Personnel Emotional Condition In Relation to Service Performance Widhiastuti, Hardani; Kurniawan, Andi; Nurhayati, Titik; Kurniawan, Yudi
Jurnal Psikologi Perseptual Vol 9, No 2 (2024): Jurnal Psikologi Perseptual
Publisher : Universitas Muria Kudus

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24176/perseptual.v9i2.13398

Abstract

This study emphasizes on the service performance of medical personnel in hospitals, one of which is due to the emotional condition of the services of the medical personnel. The research method used is quantitative method related to the emotional condition of the medical personnel measured using Vital Sign. The research subjects consisted of 67 medical personnel, but only 50 returned the google forms. While the relationship between the two used SPSS version 22. The validity test showed that the service performance variable was appropriate or valid variable.The result of the statistical analysis of Non Parametric correlation shows that there is relationship with the result of the normality test of p (sig) 0.01. It is proven that the Service Performance variable is not normal, so the test must use the non-parametric correlation test with Spearman-Rho with the correlation coefficient result of 0.562 with p (sig) 0.000. This means that there is significant relationship between the Emotional Condition variable and the Service Performance variable of the medical personnel. The results of this study prove that when the emotional condition of medical personnel increases, the service performance will decrease, which means that the responsibility for service quality decreases somewhat, dares to take risks for services that are slightly neglected, has service goal that is somewhat less attention, less planning for services, less thinking about feedback from the services provided, and the possibility of less thinking about getting the opportunity to realize services.Penelitian ini menekankan pada kinerja pelayanan tenaga medis di rumah sakit yang salah satunya disebabkan oleh kondisi emosional terhadap pelayanan tenaga medis tersebut. Metode penelitian yang digunakan adalah metode kuantitatif yang berkaitan dengan kondisi emosional tenaga medis yang diukur dengan menggunakan Vital Sign. Subjek penelitian terdiri dari 67 tenaga medis, namun yang mengembalikan google form hanya 50 orang. Sedangkan untuk hubungan keduanya menggunakan SPSS versi 22. Uji validitas menunjukkan bahwa variabel kinerja pelayanan merupakan variabel yang tepat atau valid. Hasil analisis statistik korelasi Non Parametrik menunjukkan adanya hubungan dengan hasil uji normalitas p (sig) 0,01. Hal ini terbukti bahwa variabel Kinerja Pelayanan tidak normal, sehingga pengujian harus menggunakan uji korelasi non parametrik dengan Spearman-Rho dengan hasil koefisien korelasi sebesar 0,562 dengan p (sig) 0,000. Hal ini berarti terdapat hubungan yang signifikan antara variabel Kondisi Emosional dengan variabel Kinerja Pelayanan Tenaga Medis. Hasil penelitian ini membuktikan bahwa ketika kondisi emosional tenaga medis meningkat maka kinerja pelayanannya akan menurun yang berarti tanggung jawab terhadap mutu pelayanan agak menurun, keberanian mengambil risiko terhadap pelayanan agak kurang diperhatikan, tujuan pelayanan yang agak kurang diperhatikan, kurang merencanakan pelayanan, kurang memikirkan umpan balik dari pelayanan yang diberikan, dan kemungkinan kurang memikirkan untuk mendapatkan kesempatan dalam merealisasikan pelayanan.
PELATIHAN DASAR INSTALASI TENAGA LISTRIK BAGI SMK WALISONGO SEMARANG Nurhayati, Titik; DESTYNINGTIAS, BUDIANI; Aryan, ISYA
TEMATIK Vol 5, No 1 (2025): Januari
Publisher : Universitas Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26623/tmt.v5i1.10355

Abstract

Tujuan Pengabdian ini adalah mengenalkan dasar-dasar instalasi penerangan pada siswa-siswi SMK Walisongo Semarang paham dan tertarik untuk mempelajari dasar intalasi peneragan. Metode pengabdian ini menggunakan ceramah, demontrasi, praktek modul ajar dan evaluasi. Jumlah peserta dalam pelatihan berjumlan 30 siswa dan siswi. Intrumen evaluasi kegiatan ini menggunakan pre dan post test sebagai acuhan dari proses penerapan pembelajaarah pelatihan dasar instalasi penerangan listrik.Hasil dari pengabdian ini menunjukkan para siswa siswi sangat atusian mengikuti pelatihan ini dan tertartik dalam penerapan peasangan instalasi penerangan. Harapanya agar para siswa, siswi dapat menerapkan dasar-dasar instalasi penerangan ini menerapkan dalam proses pemasangan instalasi dasar penerangan rumah tinggal dan dapat ditinggkatkan dalam bidang penerapan instalasi penerangan rumah tinggal.
Pengenalan Dan Pelatihan Dasar Robotika Bagi Siswa/Siswi SMK PGRI 01 Semarang ARYAN, ISYA; Destyningtias, Budiani; Nurhayati, Titik
Gotong Royong Vol. 2 No. 1 (2025)
Publisher : CV. Akira Java Bulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63935/gr.v2i1.83

Abstract

The introduction and basic robotics training for vocational high school (SMK) students aims to provide a fundamental understanding of robotics concepts that can be applied in industry and technology. This training combines theoretical knowledge and hands-on practice to develop skills in designing, assembling, and programming simple robots. The curriculum includes an introduction to robot components, control systems, and the programming languages used to control robot movements. Using appropriate tools and devices, students are taught how to assemble robots using robotics kits while understanding basic concepts such as sensors, actuators, and logic programming. By the end of the training, students are expected to have a foundational knowledge of robotics that can be further explored for advanced technology studies and enhance their competitiveness in the industry. This robotics introduction also aims to foster student interest and motivation in the fields of technology and engineering, as well as open career opportunities in the rapidly growing technology sector.
Stability of Dielectric Insulation System in GSUT Transformer of Pertamina Geothermal Energy Lahendong: A Diagnostic Approach Based on DFR (Dielectric Frequency Response) Sianipar, Niko Ardiansa; Nurhayati, Titik; Supari, Supari
INTERNATIONAL JOURNAL ON ADVANCED TECHNOLOGY, ENGINEERING, AND INFORMATION SYSTEM Vol. 4 No. 2 (2025): MAY
Publisher : Transpublika Publisher

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55047/ijateis.v4i2.1703

Abstract

Generator Step-Up Transformer (GSUT) is a vital component in the power system that serves to raise the voltage level before the transmission process. The operational reliability of the transformer is highly dependent on the condition of the dielectric insulation system which consists of mineral oil and insulating paper. A decrease in the quality of the insulation system can have a significant impact on the performance and operational life of the transformer. This study aims to analyze the results of Dielectric Frequency Response (DFR) testing on the GSUT Unit 6 Transformer at PGE Lahendong to evaluate the moisture content in insulating paper and the conductivity of transformer oil based on the IEC 60422 and IEC 61620 standard references. The test results based on the dissipation factor (DF) graph show that the moisture content in the insulating paper is 0.9% (dry category) and the oil conductivity is 1 fS/m, which indicates that the condition of the insulation system is still good with an estimated remaining operational life of up to 70 years by calculating the ratio between the average operating temperature value of the transformer and its dielectric rate (Dp.t). However, electromagnetic interference or bushing contamination can cause negative dissipation factor (DF) values, leading to invalid measurements. Therefore, DFR testing using the OMICRON DIRANA device proved effective in monitoring the condition of the dielectric insulation system and providing an accurate estimation of the remaining insulation life, as well as supporting the implementation of predictive maintenance strategies in power transformers.
Pendekatan Diagnostik Dielectric Frequency Response (DFR) dan Water Content Dalam Mengidentifikasi Anomali Tan Delta yang Melebihi Standar Cigré TB 445 Pada Pengujian Transformator Daya Muhammad Alvis Wijayanto; Supari; Titik Nurhayati
Syntax Literate Jurnal Ilmiah Indonesia
Publisher : Syntax Corporation

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.36418/syntax-literate.v10i5.58756

Abstract

Keandalan transformator daya bergantung pada kondisi isolasi, di mana tan delta >1% (CIGRE TB 445) mengindikasikan degradasi. Namun, penyebab spesifik anomali ini seringkali tidak terdiagnosis secara holistik. Tujuan dari penelitian ini adalah untuk menyelidiki penyebab tan delta tinggi melalui integrasi pengujian DFR dan water content pada transformator 80 MVA berusia 20 tahun. Pengujian tan delta (GST-g, UST), DFR, dan Karl Fischer untuk water content, diikuti analisis komparatif terhadap standar. Nilai tan delta 1,0509% disebabkan degradasi oli (water content 28,56 ppm), meskipun kertas isolasi kering (1,8%) dan konduktivitas oli optimal (4,1 pS/m). Penelitian ini menekankan pentingnya kombinasi DFR-water content untuk diagnosis akurat dan merekomendasikan purifikasi/regenerasi oli sebagai mitigasi. Temuan ini mendorong pengembangan model prediktif dan evaluasi oli alternatif dalam penelitian selanjutnya.
DESAIN SISTEM ROOFTOP OFF GRID PANEL SOLAR PHOTOVOLTAIC Harmini, Harmini; Nurhayati, Titik
Jurnal Pengembangan Rekayasa dan Teknologi Vol. 1 No. 2 (2017): November (2017)
Publisher : Universitas Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26623/jprt.v13i2.931

Abstract

Pada saat ini hampir semua rumah tempat tinggal menggunakan sumber energi dari jaringan PLN. Sumber energi listrik yang disediakan oleh PLN sebisa mungkin dilakukan penghematan dalam pemakaian listrik. Salah satu cara yang digunakan adalah setiap rumah menggunakan Roof top panel solar photovoltaic, hal ini bertujuan untuk mengurangi ketergantungan sumber energi dari PLN. Berdasarkan hal tersebut maka perlu dilakukan perancangan dalam pengaplikasian Roof top solar panel. Pada penelitian ini akan dirancang sistem Roof top off grid panel SPV sebagai sumber alternatif energi listrik. Perancangan diperuntukkan untuk sistem Solar Home System (SHS) atau rumah tempat tinggal dengan acuan radiasi matahari di wilayah Jawa Tengah. Sistem rooftop off grid solar photovoltaic dirancang dengan menggunakan komponen panel SPV, baterai, inverter dan charge controller. Kapasitas daya yang dirancang adalah 1.576,2 Watt dan konsumsi energi per hari sebesar 4.260 Wh Jumlah baterai sebanyak 12 unit dengan kapasitas masing-masing 310 Ah, panel SPV sebanyak 6 Unit kapasitas 225 Wp, inverter   1 unit sebesar 1000   Watt dan charge controller 1 unit sebesar 40 A. Sudut kemiringan sebesar 16 derajat. Estimasi biaya investasi yang dikeluarkans sebesar Rp.62.000.000,-
INSTALASI SOLAR HOME SISTEM PEMBANGKIT LISTRIK TENAGA SURYA SEBAGAI SUMBER ENERGI ALTERNATIF di SD IT MTA SURAKARTA Nurhayati, Titik; Supari, Supari; Nugroho, Andi Kurniawan
Jurnal Pengembangan Rekayasa dan Teknologi Vol. 6 No. 1 (2022): Mei (2022)
Publisher : Universitas Semarang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26623/jprt.v18i1.4935

Abstract

Setiap rumah diharapkan mampu membangkitkan energi alternatif yang dapat dapat digunakan untuk melayani beban sehari-hari. Salah satu cara yang dapat diterapkan adalah setiap rumah memasang Solar Home System (SHS). Instalasi dan perancangan SHS perlu dikenalkan kepada masyarakat umum salahsatunya guru agar memiliki pengetahuan tentang Pembangkit Listrik Tenaga Surya  (PLTS). Masyarakat perlu diberi pelatihan bagaimana cara merancang dan menginstalasi SHS di rumah masing-masing. Pelatihan ini akan diberikan kepada Guru SDIT MTA Semanggi sesuai permintaan dari kepala sekolah.Permasalahan yang dihadapi mitra adalah kurangnya pengetahuan Masyarakat terutama Guru SDIT MTA Semanggi tentang (1) Bagaimana proses konversi energi dari energi matahari menjadi energi listrik, (2) Bagaimana energi matahari tersebut bisa dimanfaatkan untuk rumah tangga atau SHS, (3)Bagaimana cara merakit atau menginstal peralatan supaya terbentuk SHS. Solusi yang ditawarkan untuk menyelesaikan permasalahan mitra adalah memberikan pelatihan kepada Guru SDIT MTA Semanggi tentang bagaimana melakukan instalasi SHS PLTS sebagai sumber energi alternatif skala rumah tangga. Pelatihan dilaksanakan dengan waktu selama 3 jam pada Hari Selasa, 12 Oktober 2021Pelatihan diikuti oleh 13 Guru SDIT MTA Semanggi.  Hasil pelaksanaan pengabdian terlihat dari hasil pre test dan post test.  Hasil pretest menunjukkan bahwa dari 13 SDIT MTA Semanggi yang diberikan tidak ada yang mendapatkan nilai 100. Setelah dilakukan pelatihan, rata-rata menjawab benar sebanyak 10 Guru. Hal ini menunjukkan bahwa pemahaman Guru mengalami peningkatan sebanyak 90%, sehingga dapat diartikan setelah dilakukan pelatihan banyak Guru yang paham tentang SHS PLTS.              K
Klasifikasi Jenis Penyakit Tumor Otak Menggunakan Convolutional Neural Network Arsitektur Inception-V3 Juliartadi, Hendra Ady; Nugroho, Andi Kurniawan; Heranurweni, Sri; Nurhayati, Titik
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 19 No. 3 (2025)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v19n3.2868

Abstract

Tumor otak merupakan salah satu penyakit yang paling mengancam nyawa dan memerlukan diagnosis yang akurat. Salah satu tantangan utama dalam mendiagnosis tumor otak terletak pada kesamaan visual antara jenis tumor pada gambar MRI, yang seringkali menyulitkan klasifikasi manual. Untuk mengatasi hal ini, sistem klasifikasi berbasis deep learning dikembangkan menggunakan metode Convolutional Neural Network (CNN) dengan arsitektur Inception-V3. Data yang digunakan diperoleh dari Kaggle dan terdiri dari empat kelas glioma, meningioma, pituitari, dan notumor. Penelitian ini menerapkan teknik pre-procesing seperti Contrast Limited Adaptive Histogram Equalization (CLAHE) dan augmentasi data untuk meningkatkan kinerja model. Berbagai kombinasi hyperparameters diuji, dan kinerja terbaik dicapai dengan batch size 32 dan learning rate 0,0001. Model mencapai accuracy 97,92%, precision 98%, recall 98%, dan F1-score 98%. Selain itu, arsitektur Inception-V3 dibandingkan dengan arsitektur lain yaitu MobileNetV2 dan ResNet50, yang mencapai accuracy 83,67% dan 71,79%. Hasil menunjukkan bahwa arsitektur Inception-V3 unggul dalam mengklasifikasikan jenis tumor otak dari gambar MRI. Penelitian ini diharapkan dapat berkontribusi dalam meningkatkan akurasi dan kecepatan diagnosis tumor otak bagi medis.
Pelatihan Dasar Teknik Tenaga Listrik Bagi SMA Kesatrian 2 Semarang Nurhayati, Titik; Destyningtias, Budiani; ISYA ARYAN, ISYA ARYAN SULISTYO; Nurul, Yusuf
Gotong Royong Vol. 2 No. 3 (2025)
Publisher : CV. Akira Java Bulu

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.63935/gr.v2i3.211

Abstract

The distribution system and method of installing electrical installations in Indonesia must follow the rules set by PUIL (General Regulations on Electrical Installations) which was published in 1977, then revised in 1987 and last in 2011. PUIL 2011 is the main technical reference for installing low voltage electrical installations. The purpose of this community service is to provide knowledge to students about the importance of electrical lighting installations in accordance with PUIL regulations to avoid the danger of fire or electric shock. Another goal is to provide knowledge about work safety in installing electrical installations because of the frequent occurrence of work accidents during installation. The problems faced by the community are the lack of knowledge of the community / high school students about (1) Lack of special skills for Kesatrian High School graduates in analyzing electrical problems, especially in electrical lighting installations in accordance with PUIL standards (2) Lack of detailed explanation through a theoretical approach regarding the basic problems of electrical lighting installations for graduates of SMA Kesatrian 2. The training provided is in the form of providing material explanations, regarding the basic legal understanding of electrical installations, Law No. 30 of 2009 concerning Electricity, Government Regulation (PP) No. 25 of 2023 concerning       Electrical Safety Replacing PP No. 10 of 1989 and updating safety standards,” In addition, there is ESDM Ministerial Regulation No. 12 of 2021 concerning Electrical Power Utilization Installations SNI 04-0225-2000 concerning Procedures for planning electrical installations in Buildings. The expected results are that students can read single diagram drawings and wiring diagrams, are able to apply them in practice in the field and indirectly develop a sense of independence. The approach methods offered to solve the partner's problem are (1) providing training to students of Kesatrian 2 Semarang High School about the electrical power installation process, (2) conducting simulations about how to install electrical power.