Studi Perbaikan Jatuh Tegangan Dan Rugi Daya Pada Jaringan Tegangan Rendah Dengan Pembangunan Gardu Sisip Tipe Portal Septianissa Azzahra; Oktaria Handayani; Siti Auliya
KILAT Vol 8 No 1 (2019): KILAT
Publisher : Sekolah Tinggi Teknik - PLN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (462.921 KB) | DOI: 10.33322/kilat.v8i1.319

Abstract

In the system of reliability of electric power distribution that is concerned is good and stable voltage quality, because although the continuity of the supply of electrical energy is reliable, but still there will be a voltage drop. Another factor that affects the system voltage change is the power loss caused by the impedance of the conductor channel series, this power loss causes a voltage drop. Consumers who are located far from the service point tend to receive relatively lower stresses, when compared to the voltage received by consumers who are located close to the service center. The existence of a voltage drop on the receiving end pole can cause the network current to be high so that losses that occur in the network increases. To overcome these problems then performed network repair by building substation distribution insertion so as to improve the quality of the voltage and minimize the loss of power on the network. From the calculation of the percentage value of the voltage drop in PT. PLN Area Cikupa before the installation of the substation is 10.6% for the S phase 1 and 11.7% for the S phase 4, the value is not in accordance with SPLN No. 1 of 1995, the tolerance limit of service voltage variation as a result of voltage loss is a maximum of + 5% and a minimum of -10% at the service side. After the installation of the substation was installed, the voltage dropped to 5.1% for the S phase 1 and 6.1% for the S phase 4, where the value was in accordance with the standard.
PEMODELAN PEMBANGKIT LISTRIK FOTOVOLTAIK YANG TERHUBUNG KE JARINGAN Agus Yogianto; Ibnu Hajar; Septianissa Azzahra
KILAT Vol 7 No 2 (2018): KILAT
Publisher : Sekolah Tinggi Teknik - PLN

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2659.659 KB) | DOI: 10.33322/kilat.v7i2.363

Abstract

PLTS performances as a power plant does not only convert energy, so that electricity is generated, but in the study of power systems it becomes a major element that has an important role in the study of power systems. As a power system element, the PLTS acts as an element of electricity generation in this study modeled as a PV system and connected to the network, so it must meet the requirements of the electric power network operation. Through MATHLAB / SIMULINK modeling and simulation, a 100 kW peak PLTS power plant has been modeled connected to the network. From the simulation and analysis obtained, this PLTS model shows that the connected load affects the voltage condition but does not affect the frequency. The load power factor also affects the network, namely with a lower load power factor, it affects the voltage on the network.