ANALISA PERBANDINGAN SIMPANGAN STRUKTUR GEDUNG SET BACK TANPA DINDING GESER DAN PEMODELAN LETAK DINDING GESER DI ZONA GEMPA TINGGI Tondi Amirsyah Putera; Fiqih Hidayat
Portal: Jurnal Teknik Sipil Vol 9, No 1 (2017)
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/portal.v9i1.611

Abstract

The high-rise building structure is prone to lateral forces, mainly due to the force generated by the earthquake. In calculating the multilevel building structure there are 2 ways, namely with Open Frame and Open Frame combination with shear wall. The shear wall is a wall that acts as a stiffener and is also a core wall for rigging entire buildings designed to withstand shear forces, lateral forces caused by earthquakes. so that the horizontal deformation (deflection) becomes small. The analysis used in this research is spectrum response analysis based on SNI 1726: 2012. This research has 3 model of set back building which will be reviewed, that is the model of set back building with special moment frame system, the model of backyard building with shear wall of each side and model of set back building with shear wall only on one side. All load inputs, stiffness and structural dimensions are the same, which differ only the special moment frame system model and the sliding wall placement used. This building has a height of 39.5 meters (10 floors). Based on this data it shows that the deviation result with the deviation modeling for the model is 0.075 m for the X and 0.064 direction for the Y direction for model 2 0.051 m for the X and 0.050 m directions for the Y direction and for model 3 is 0.074 m for the X and 0.048 for direction Y.Keywords: Set Back, Irregular Building, Drift Story, Shear Shear, Shear Wall, Special Moment Resume Frame.
DEFORMASI STRUKTUR BANGUNAN RUMAH TOKO DI MEDAN AKIBAT GEMPA BERULANG Tondi Amirsyah Putera; Rizki Efrida; Hadianti Muhdinar Pasaribu
Portal: Jurnal Teknik Sipil Vol 10, No 1 (2018)
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/portal.v10i1.971

Abstract

Di Sumatera Utara (Sumut) banyak kota yang terletak dekat dengan Sesar Mendatar dan Sesar Subduksi Sumatera. Kota-kota ini memiliki banyak fasilitas bangunan komersil termasuk rumah toko. Kedua sesar aktif ini adalah sumber utama gempa tektonik di Sumut yang telah banyak membuat bencana. Struktur rumah toko yang rusak minor akibat sebuah gempa dapat menjadi rusak berat atau rubuh setelah mengalami gempa berikutnya. Bedasarkan hal tersebut diatas, merupakan dasar dari tujuan penulisan ilmiah ini yaitu untuk mengetahui struktur bangunan rumah toko terhadap kesesuaian dengan standarisasi konstruksi tahan gempa yang berlaku yaitu SNI 1726:2012 dan mengevaluasi kekuatan struktur bangunan rumah toko terhadap kejadian gempa berulang. Dalam penulisan ilmiah ini ada 3 model Rumah Toko (RUKO) yang akan dianalisis yaitu RUKO A yang berada dijalan Tuasan Kecamatan Medan Tembung, RUKO B yang berada di jalan Alfalah 4 yang berada di Medan Timur dan RUKO C yang berada di jalan Budi Kemasyarakatan Kecamatan Medan Barat. Untuk semua model ini dilakukan pengamatan dilapangan yaitu berupa uji pantul dengan menggunakan alat Uji Pantul dan uji tarik tulangan baja pada laboratorium teknik mesin UMSU. Analisis model ini menggunakan software analisis struktur dengan pengamatan dalam 2 kondisi yaitu kondisi repon spektrum linier elastis dan dinamis riwayat waktu gempa berulang nonlinier inelastik terhadap. Bila dilihat dari periode waktu alami struktur, kondisi RUKO C ternyata melebihi standar periode dan simpangan melebihi batas maksimum yang diijinkan begitu juga pada saat analisis nonlinier  inelastik akibat gempa berulang ternyata simpangan atap yang terbesar juga pada RUKO C. Untuk kebutuhan daktalitas untuk semua model RUKO peningkatan kebutuhan daktalitas saat gempa berulang 2 kali adalah 23,4 % dan 42% pada saat gempa berulang 3 kali. 
EVALUASI DAN PERENCANAAN PILE CAP PADA FLY OVER JAMIN GINTING KOTA MEDAN Tondi Amirsyah Putera; Husin M. Gultom; Ferry Perdana Susanto
Portal: Jurnal Teknik Sipil Vol 11, No 2 (2019)
Publisher : Politeknik Negeri Lhokseumawe

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30811/portal.v11i2.1524

Abstract

Abstrak — Pile cap merupakan salah satu elemen penting dari suatu struktur. Hal ini dikarenakan pile cap memiliki peranan penting dalam pendistribusian beban struktur ke tiang bor untuk kemudian diteruskan ke dalam tanah. Dalam perencanaan pile cap, terdapat berbagai metode desain, salah satunya adalah metode strut and tie. Tujuan dari studi ini adalah untuk menganalisa dan mengevaluasi perencanaan pile cap di titik P10 pada proyek Fly Over Jamin Ginting dengan menggunakan metode strut and tie. Perhitungan metode strut and tie dilakukan berdasarkan peraturan ACI Building Code 318-2002, yang meliputi desain model strut and tie, besar gaya yang terjadi, serta penulangan pile cap. Untuk memperoleh hasil yang signifikan, maka perhitungan metode strut and tie dilakukan dua cara yaitu secara manual dan dengan menggunakan program komputer yaitu CAST. Dari hasil analisa dan perhitungan yang dilakukan, terdapat perbedaan hasil dimana perencanaan metode strut and tie yang dilakukan menggunakan program CAST memberikan luas tulangan dan gaya-gaya yang terjadi pada struktur sedikit lebih besar dibandingkan dengan metode secara manual. Untuk metode yang dilakukan secara manual, besar gaya yang terjadi pada masing-masing strut F1 = 7384,9 kN ; F2 = 6445,7 kN ; F3 = 4926,9 kN dan tulangan yang digunakan pada tie F1 = 66 D 32 ; F2 = 50 D 32 ; F3 = 26 D 32, dengan luas total tulangan sebesar 114145,28 mm2. Sedangkan metode dengan menggunakan CAST, besar gaya F1 = 8930 kN ; F2 = 6742,8 kN ; F3 = 5082,5 kN dan tulangan yang digunakan pada tie F1 = 70 D 32 ; F2 = 54 D 32 ; F3 = 34 D 32, dengan luas total tulangan sebesar 129402 mm2.Kata kunci : pile cap, program, ACI 318-02, strut and tie.Abstract — Pile cap is one of important element of the structure. Therefore the pile cap has important figure in distribute structure load to bore pile which is forwarded into ground then. In pile cap planning, there are various of design methode, which the one of is strut and tie methode. The purpose of this study is to analyxe and evaluate the planning of pile cap in P10 at Fly Over Jamin Ginting project by using strut and tie methode. The calculation of strut and tie methode based on ACI Building Code 318-2002 rule, which involve strut and tie design, value of force occur, and pile cap reinforcement. To obtain the significant result, then the calculation of strut and tie methode is done by two ways, by manually and using computer program CAST. From the result of analysis and calculation that have been done, obtained difference value which is the strut and tie methode by using CAST gave extensive reinforcement and forces occur bit bigger than by manually. For methode by manually, value of forces occur in each struts F1 = 7384,9 kN ; F2 = 6445,7 kN ; F3 = 4926,9 kN and reinforcement ties F1 = 66 D 32 ; F2 = 50 D 32 ; F3 = 26 D 32,within extension reinforcement is 114145,28 mm2. Meanwhile the methode by using CAST, value of forces occur in each struts F1 = 8930 kN ; F2 = 6742,8 kN ; F3 = 5082,5 kN and reinforcement ties F1 = 70 D 32 ; F2 = 54 D 32 ; F3 = 34 D 32, within extension reinforcement is 129402 mm2..Keywords: pile cap, program, ACI 318-02, strut and tie
EVALUASI PERBANDINGAN SIMPANGAN STRUKTUR SRPM AKIBAT PERMODELAN STRUKTUR YANG BERBEDA Tondi Amirsyah Putera; Ade Faisal; Suprayetno .
Educational Building Jurnal Pendidikan Teknik Bangunan dan Sipil Vol 4, No 1 JUNI (2018): EDUCATIONAL BUILDING
Publisher : Jurusan Pendidikan Teknik Bangunan Fakultas Teknik Universitas Negeri Medan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1226.942 KB) | DOI: 10.24114/eb.v4i1.10040

Abstract

Struktur bangunan bertingkat rawan terhadap gaya lateral, terutama akibat gaya yang ditimbulkan oleh gempa. Indonesia juga termasuk ke dalam wilayah yang memiliki instensitas terjadi gempa yang tinggi. Dalam menghitung struktur bangunan bertingkat ada 2 cara, yakni dengan sistem rangka pemikul momen (SRPM) dan kombinasi SRPM dengan shear wall. Pada proses perencanaan umumnya dinding geser dimodelkan sebagai element solid pada program komputer. Pemakaian element solid ini akan memakan waktu analisa seiring dengan semakin bertambahnya tinggi bangunan. Dinding geser juga dapat dimodelkan dengan element garis (line). Untuk itu studi ini bertujuan membandingkan hasil yang diperoleh bila dinding geser dimodelkan sebagai element solid dan element garis. Pada studi ini terdapat 3 pemodelan struktur, yaitu 1 model strktur tanpa dinding geser, dan 2 model truktur dengan dinding geser (model dinding geser solid element dan model dinding geser  line element). Semua input beban, tingkat kekakuan dan dimensi struktur adalah sama, yang berbeda hanyalah model shear wall yang digunakan. Gedung ini memiliki tingggi 40 meter (10 lantai), tinggi tiap lantai 4 meter. Berdasarkan hasil analisis tersebut diperoleh bahwa terjadi perbedaan perioda getar, simpangan, gaya geser dasar dan gaya-gaya dalam karena pemodelan sistem struktur penahan gaya geser yang berbeda-beda.  Kata Kunci : Dinding Geser, Pemodelan Struktur, Simpangan   ABSTRACT The structure of multi-storey buildings are vulnerable to lateral force, especially due to the force created by the earthquake. Indonesia is also included in the territory which has instensitas an earthquake is high. In calculating the structure of multi-storey buildings there are two ways, namely as moment resisting frame system (MRF) and combination of MRF with shear wall. The development of science and technology has given rise to one of the solutions to improve the performance of high-level structure, namely the installation of shear walls to add structural rigidity and absorbs shear forces along with the high structure. The goal of this studi is to determine the difference of some parameters made of a combination of structural design of the building with MRF and MRF with shear wall. In this study, there are 3 modeling of structures, namely 1 models structure without shear walls, and two models of structures are at the shear wall (solid element model of shear walls and shear wall model line element). All input load, stiffness and dimensional structure is the same, just different shear wall models used. This building has 40 meters (10 floors) of height, which is the height of each floor 4 meters. The results of the analysis indicates that the significant deviation occurs due to system modeling of shear wall is different. Keywords: Shear Wall, Structure Modelling, Displacement
EVALUASI JARAK AMAN ANTARA STRUKTUR SRPM TINGGI DENGAN STRUKTUR SRPM DISEBELAHNYA TERHADAP GEMPA Ade Faisal; Tondi Amirsyah Putera; Mariden Purba
Educational Building Jurnal Pendidikan Teknik Bangunan dan Sipil Vol 4, No 1 JUNI (2018): EDUCATIONAL BUILDING
Publisher : Jurusan Pendidikan Teknik Bangunan Fakultas Teknik Universitas Negeri Medan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (840.292 KB) | DOI: 10.24114/eb.v4i1.10045

Abstract

Pembangunan gedung-gedung tinggi menjadi salah satu alternatif yang di pilih karena keterbatasan dan mahalnya lahan diperkotaan sementara tingkat permintaan ruang untuk berbagai kegiatan semakin tinggi. Hal ini menyebabkan gedung-gedung bertingkat sering dibangun saling berdekatan satu dengan yang lainnya. Benturan dapat terjadi pada dua bangunan gedung bertingkat yang bersebelahan apabila jarak antara dua bangunan lebih kecil dari simpangan maksimum yang terjadi akibat beban gempa. Studi ini bertujuan untuk mencari jarak aman antara dua bangunan tinggi yang bersebelahan. Gedung yang direncanakan 2 model menggunakan SRPM dengan material beton bertulang yang terletak di kota Medan dengan kondisi tanah sedang. Model  pertama (Model 1) direncanakan memiliki tinggi 28,5 meter terdiri dari 8 lantai, sedangkan Model kedua (Model 2) direncanakan memiliki tinggi 35,5 meter terdiri dari 10 lantai. Analisa yang digunakan pada studi ini yaitu analisis dinamik riwayat waktu. Nilai simpangan yang terjadi pada gedung  8 lantai (Model 1) untuk arah x sebesar 80,87 mm dan untuk arah y sebesar 79,35 mm. Simpangan yang  terjadi pada gedung 10 lantai (Model 2) untuk arah x sebesar 113,33 mm dan untuk arah y sebesar 112,39 mm. Hasil analisa yang dilakukan menunjukkan jarak aman antara gedung 8 lantai dengan gedung 10 lantai adalah sebesar 2,1 meter, sedangkan jarak aman antara gedung 10 lantai dengan gedung 10 lantai adalah sebesar 2,2 meter.  Kata Kunci : Analisis Riwayat Waktu, Benturan Antar Gedung, Jarak Antar Gedung, Simpangan  ABSTRACT The construction of tall buildings became one of alternative that was chosen because of the urban land limitations and the cost. At the same time the space demand for various urban activities is increased. It is caused the high-rise buildings are often built very close to one another. The collision can be occurred if two adjacent building if the distance between the two building is smaller than the maximum drift caused by the earthquake action. This study aims to plan a safe distance between two adjacent high-rise buildings. The planned building two models using Moment Resisting Frame with reinforced concrete material that is located in the city Medan with moderate soil conditions. The first model (Model 1) has a height of 28.5 meters is planned consists of 8 floors, while the second model (Model 2) planned to have a height of 35.5 meters consists of 10 floors. The analysis used in this study is the analysis of dynamic time history. The displacement value which occurred on 8 storey building (Model 1) to the x direction by 80.87 mm and for the y direction by 79.35 mm. The displacement occurs in the building 10 floors (Model 2) to the x direction of 113.33 mm and for the y direction of 112.39 mm. The results of analysis indicate that the safe distance between 8 storey building with 10 floors of the building is 2.1 meters, while the safe distance between buildings 10 floors with 10 storey building is 2.2 meters. Keywords: Time History Analysis, Clash Between Buildings, Distance Between Buildings, Deviation
Perilaku Deformasi Tidak Linear SRPMK Baja 8 Lantai Akibat Gempa Faisal, Ade; Putera, Tondi Amirsyah; Efrida, Rizki
MEDIA KOMUNIKASI TEKNIK SIPIL Volume 30, Nomor 2, DESEMBER 2024
Publisher : Department of Civil Engineering, Diponegoro University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.14710/mkts.v30i2.62448

Abstract

The inter-story drift occurs as the result of rotational deformation on the frame’s joint affected by ground shaking. This rotational deformation occurs as an accumulation of bending deformation in beams and columns as well as shear deformation in the panel zone. The goal of this study is to analyze how cyclic non-linear deformation occurs in beam elements and zone panels. The 8-story steel moment resisting frame built on class D soil and designed for seismic design category D were used as model. Incremental nonlinear dynamic analysis was carried out using 20 earthquake ground motions that contained with and without pulse effects. This was done so in order to identify the median value and standard of deviation of the LS, CP, and collapse boundary conditions. Nonlinear flexure and shear deformations that occur in beam element and panel zone were explored. The results obtained show that the rotational deformation of the beam due to actual flexure is greater when compared to the rotational deformation at IDRmax reaches the first time LS and CP boundary conditions. The similar trend occurs in shear deformation of the panel zone.
Iot-Based Real-Time Monitoring System For Enhancing Shrimp Pond Management: A Case Study In Deli Serdang, North Sumatra, Indonesia Umurani, Khairul; ., Rahmatullah; Asfiati, Sri; Nasution, Arya Rudi; Putera, Tondi Amirsyah; Saputra, Andrea
Rekayasa Material, Manufaktur dan Energi Vol 8, No 2: JULI 2025
Publisher : Fakultas Teknik UMSU

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30596/rmme.v8i2.24543

Abstract

Monitoring shrimp ponds involves observing and measuring key environmental factors that influence shrimp health and growth. This study was conducted at a shrimp pond on Jalan Paluh Merbau, Tj. Rejo, Kec. Percut Sei Tuan, Deli Serdang Regency, North Sumatra, Indonesia. Traditionally, air humidity and water temperature are monitored manually by taking water samples for laboratory analysis or using litmus paper. These conventional methods are time-consuming and prone to inaccuracies, potentially compromising shrimp health. To address these challenges, this research implemented an Internet of Things (IoT)-based monitoring system to automate the measurement of air humidity and water temperature. The system utilizes DHT11 and DS18b20 sensors, integrated with an ESP32 module, to continuously collect data and automatically transmit it to Google Sheets for real-time monitoring. This IoT approach enables shrimp farmers to easily track water quality parameters, enhancing the accuracy and efficiency of pond management. A two-day testing phase demonstrated stable environmental conditions, with humidity levels recorded at 86.5% to 87.78% and water temperatures ranging from 27.55°C to 28.06°C. These readings were within the ideal thresholds for optimal shrimp growth, showcasing the system's effectiveness in maintaining suitable pond conditions. This research will contribute significantly to more efficient, accurate, and sustainable shrimp farming practices.