Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer
We are the Editor of Jurnal ELTIKOM, invites Mr. / Ms Lecturer, researcher and practitioner to be able to publish your paper on topics covering Electrical Engineering, Electronics Engineering, Telecommunications Engineering, Computer Engineering, Information Technology.
Articles
11 Documents
Search results for
, issue
"Vol. 6 No. 2 (2022)"
:
11 Documents
clear
A Bot Approach-Based Capacity Testing Automation for Online Video Games
Sidiq, Adity M.;
Husen, Jati H.;
Widowati, Sri
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.550
Online games are a type of computer game that can be accessed using the internet network and played with other players to play the same game. With the advance in online game development, game developers are required to develop games that can be played by many players in one game, especially in the capacity of an online game server. Those needs can be achieved by utilizing bots. However, previous works only conducted bot-based testing for testing network capabilities. In this research, those works will be extended further ftotesting the capacity of a game server. The result of this research suggests that bot approach testing can simulate real players adequately. Other than that, the bot approach also can be scalable. However, the result also suggests that the bot approach still has some limitations as bots cannot simulate the dynamics shown by real players. Special attention is also needed towards clients utilized for executing the bots for them to be scalable.
Sistem Pemantau Suhu Cooler Box Berbasis Telemetri Dengan Thermoelectric Cooler Sebagai Bakteriostatik Pada Ikan
Yudianto, Renangga;
Yudhana, Anton
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.551
Indonesia has enormous marine resource potential, which can be explored as a prime mover of national economic development, one of which is fisheries resources. The factor that determines the selling value of fish is the freshness of the fish. This study aims to utilize Thermoelectric Cooler (TEC) in cooler boxes as a bacteriostatic system for fish that is environmentally friendly and monitored using telemetry based DS18B20 ESP8266 temperature sensor. The temperature data includes the temperature of the cooler box, the temperature of the Thermoelectric Cooler (TEC), and the temperature of the room. The parameters used to test the quality of DS18B20 temperature sensor are accuracy, normality test, homogeneity test, and independent samples t-test. The data of DS18B20 temperature sensor system is processed at nodeM-CU then sent and displayed via the thingspeak website and LCD in real time. Organoleptically, the obser-vation results of fish A placed in a cooler box are categorized as fresh, and the observation results of fish B which are placed at room temperature are categorized as not fresh according to (SNI 2729:2013). The sensor test results obtained in this study showed value of the temperature accuracy of cooler box was 97.8%, the temperature accuracy value of Thermoelectric Cooler (TEC) was 98.56%, the room tempera-ture accuracy value was 99.67%, the results of normality test of three temperature sensors are normally distributed, the results of homogeneity test of three temperature sensors are homogeneous, and the results of independent samples t-test are not significantly different, which indicates that three DS18B20 tempera-ture sensors are accurate.
Komparasi Performansi Antara Proportional Integral Derivative Controller (PID) Dan Fuzzy Logic Controller (FLC) Pada Penjejak Cahaya Dengan Tiga Sensor
Gunawan, Doni;
Away, Yuwaldi;
Sara, Ira Devi;
Novandri, Andri
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.552
The technology of light tracking monitors the solar panels to track the sun with full efficiency, and the solar panels can be upright to the sunlight in order to maximize the absorption of solar energy, so this system has a higher efficiency than non-tracking systems. This study aimed to obtain a controller that works accurately between the Proportional, Integral, and Derivative Controller (PID) and the Fuzzy Logic Controller (FLC) Algorithm by comparing the performance of the two algorithms in regulating the direction of the light tracker to detect the presence of sunlight. This solar prototype uses nine lamps as a simulation to determine the accuracy and precision of the angles of the two light trackers. The parameters compared in this test were the aspects of angular velocity and angle accuracy. The mean value of angular velocity obtained from the PID light tracking test results was 0.16 rad/s and the average linear velocity was 0.092 m/s whereas in the FLC light tracker, the average angular velocity value was 0.207 rad/s. Tests using a PID light tracker resulted in an X-axis accuracy of 45% and a Y-axis accuracy of 30%. The FLC light tracker, on the other hand, had an X-axis accuracy of 80% and a Y-axis accuracy of 30%.The precision value obtained by the PID light tracker on the X axis was 45% and the Y axis was 38%, while the precision value obtained by the FLC light tracker on the X axis was 71% and the Y axis was 33%. Based on the overall calculations, it can be concluded that the FLC light tracker has an increase in the speed value of 29% and an increase in the value of accuracy in the accuracy aspect by 35% and the precision aspect by 26% compared to the PID light tracker in previous studies.
IOT Application For Conveyor Motor Load Current And Temperature Monitoring Device for Factory Acceptance Test in Industrial Application
Rospawan, Ali;
Simatupang, Joni Welman;
Purnama, Irwan
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.553
In industrial application on machine manufacturer multinational company, especially on the conveyor manufacturing company, before delivering the conveyor to overseas customer, there are some regulations need to be complied to ensure the product quality is always good. The system to ensure the product quality before delivery is named by Factory Acceptance Test (FAT). The purpose of doing this is to gain the trust and satisfaction of the buyer company by ensuring the quality before delivery. To ensure the product quality, this device was designed following the customer check sheet and requirement by giving them reliable data of the load current on each line of the motor and the motor temperature. This device is consisting of WEMOS D1 mini as the main controller and an IoT device, thermocouple type K as a temperature sensor, MAX6675 as the driver of the thermocouple, SCT-013-005 as a split-core current sensor, Arduino Nano as the second controller, and LCD 2004 as a real-time display. The IoT Application for Conveyor Motor Load Current and Temperature Monitoring Device is successfully created with the output is a table of data and the line chart which consists of Load current on each phase (U1, V1, W1), the motor temperature, and the limitation of each data so the user is easier to determine the commissioning result of the Factory Acceptance Test.
Perbandingan Efisiensi Aktual Dan Spesifikasi Generator BTG II Power Plant PT. Semen Tonasa 2×35 MW Pada Berbagai Beban Aktual
Usman, Usman;
Multazam, Ahmad;
Gaffar, Ahmad
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.554
The efficiency of generators in a power plant decreases as running duration increases. This can also happen to the generator of the PT. Steam Power Plant. The Semen Tonasa Power Plant is also known as the Boiler Turbine Generator (BTG) Power Plant. BTG II has been operating for approximately 8 years and based on generator operation data, there has been a decrease in the power generated by the genera-tor, when viewed from the power input to the current turbine, compared to the initial operation of this plant. The aims of this study are to assess the value of the real generator efficiency and compare it to the efficiency generator based on its specifications. Data loading is required to ascertain the true value of generator efficiency, as the output power created by the generator and the input power is the power gen-erated by the turbine, which is computed using the enthalpy reduction method. According to the research, the average generator efficiency values for generator units C and D are 91.36 percent and 90.34 percent, respectively, with real average loads of 25,56 MW and 25,08 MW. In comparison to the data standards, generator unit C saw a 6.76 percent drop in efficiency, whereas generator unit D experienced a 7.76 per-cent decrease efficiency. Comparison with the data specifications for generator units C experienced a decrease in efficiency of 6,76% while generator unit D experienced a decrease in efficiency of 7,76%. The efficiency of the generator in unit C decreased 0.85% per year, and unit D was 0.97%.
Pengembangan Aplikasi Pelayanan Dokumen untuk Mahasiswa
Rozi, Nanang Fakhrur;
Mauludin, Mohammad;
Rachman, Andy
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.555
Document services are often found in government and education environments. Document service aims to produce a document as evidence or validation of something according to the request of the applicant. The document service process often does not run smoothly because there are obstacles such as the number of applicants, limited space, and limited service time. In the modern era like today, these problems can be solved by making a special application for document services in order to make it easier for applicants to submit files to the service unit. This study aims to design and build a document service application to assist applicants in requesting document services. The main feature in the application that was built is that applicants can submit the required files online without having to queue. In addition, the application that was built also has a unique feature, namely that document files that have been submitted are automatically forwarded to the related unit. This feature can assist service units in managing documents, because the requirements file does not need to be submitted manually. There is an additional feature in the form of a document service process tracking system so that applicants can see the development of services directly. The application was developed using the Spiral Model. There are four stages carried out in this model. The four stages are planning, risk analysis, development as well as testing, and evaluation. In the final stage, an application evaluation is carried out by applying the ISO 9126 standard. Based on the results of user assessments, the level of user satisfaction in terms of usability is 77.43%, functionality 78.95%, and efficiency 77.86%.
Desain Sistem Kontrol Level Cairan Dengan Metode PID Berbasis PLC
Putri, Ratna Ika;
Setiawan, Hendra Mars;
Setiawan, Budhy;
Wibowo, Sunu Hasta
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.570
This article discusses the water level control of the tank using PID control which is implemented on PLC (Programmable Logic Control) with HMI interface. This plant system consists of a controlled tank, a sup-ply tank, a water level sensor, a water faucet in the form of a motorized valve, PLC and HMI. In previous studies, the plant system used usually only has a controlled tank without a supply tank so that the control of the system becomes simpler. However, in this study a supply tank was also used so that the flow of water flowing in controlling the water level would depend on the water level of the supply tank and the opening of the water faucet. This plant system with a tank that has an open outlet pipe is a classic system that is non-linear so linearization is needed in its control. In order for the system to be linearized, it is assumed that both the supply tank and the controlled tank only operate within a certain value range. The realiza-tion of a water level control system using a PID controller was made and tested for its effectiveness at the setpoint values of 10 cm and 20 cm. Based on the simulation and experimental results, it was found that the system worked well where the PID control was able to stabilize the system at both setpoint values where the obtained overshoot were below 10%.
SISTEM KONTROL SUDUT PITCH BILAH TURBIN ANGIN MENGGUNAKAN LOGIKA FUZZY UNTUK VARIABLE SPEED VERTICAL AXIS WIND TURBINE (VAWT)
Hidayat, Mohammad Noor;
Hasanuddin;
Wibowo, Sapto
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.571
VAWT (Vertical Axis Wind Turbine) is a turbine that has an upright mechanical structure with its blades rotating toward a perpendicular z-axis. Based on the experimental results, it is found that there is a relationship between the rotational speed of turbine that rotates generator with the output voltage and power. Thus, it is necessary to control the wind turbine speed so it can rotate according to the set point to be achieved. The contribution of this research is the development of a Fuzzy logic-based control system to control the speed of VAWT turbine where the speed of turbine is used as feedback. To design a Fuzzy rule base, the characteristics of the wind turbine’s response to wind speed are investigated first. Then Fuzzy logic-based controller is created and implemented. To test the effectiveness of the Fuzzy controller made, the implementation is carried out on a VAWT turbine while the simulation is applied to PMSG model using wind turbine through Simulink/Matlab. Based on simulation and experiment results, the performance of the control system using Integral Absolute Error (IAE) for each turbine speed set point value (35, 45, 85, and 100 RPM), it is found that for a small set point value, the IAE value will be larger than higher setpoints. The percentage of the average IAE value for the simulation is 10.25% higher than the experiment. It further shows that the control turbine speed at low speeds is relatively more difficult than at higher speeds.
PENINGKATAN KEAMANAN DATA END-TO-END SMART DOOR MENGGUNAKAN ADVANCED ENCRYPTION STANDARD
Adhiwibowo, Whisnumurti;
Hirzan, Alauddin Maulana;
Suprayogi, Muhammad Sani
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.574
Smart Home is one form of implementation of Internet of Things technology in the form of smart homes that can carry out management, monitoring, even reporting. In addition, smart homes can be equipped with security equipment such as Smart Door that can open or lock the door automatically when recognizing the homeowner's face. However, the current Smart Door model has a disadvantage where the stored data on the server and the device are not secured end-to-end. The homeowners' image data on the device is not encrypted with a specific algorithm and validation. Thus, the outside parties can use this high-risk problem to enter the house unnoticed. They disguised themselves as the homeowner by entering false data on the device. Based on this problem, this study has a purpose to increase the model's end-to-end security by implementing the Advanced Encryption Standard algorithm. In addition to increase the security level, the Truncated Decimal-converted SHA-1 checksum validation is added to prevent modifications in each image data. From the results of the model comparison experiment, there was an increase in device resource needs as much as 0.81% increase in process time; 18% CPU usage; 5.3% data usage; and 5.04% for the use of the entire process of memory. But the increase in performance needs is not comparable to the security features presented by the Advanced Encryption Standard algorithm in securing data and servers. So that with improvisation this security is expected to improve the data security of homeowners from outside parties.
PEMODELAN BATERAI AIR GARAM DAN PENGUJIAN SALINITAS ELEKTROLIT BERBASIS PLC
Hidayat, Mohammad Noor;
Mayrullah, Fahriza;
Sapto Wibowo
Jurnal ELTIKOM : Jurnal Teknik Elektro, Teknologi Informasi dan Komputer Vol. 6 No. 2 (2022)
Publisher : P3M Politeknik Negeri Banjarmasin
Show Abstract
|
Download Original
|
Original Source
|
Check in Google Scholar
|
DOI: 10.31961/eltikom.v6i2.577
One of the technologies of this power source is a brine battery. In this study, testing the effect of electrolyte salinity levels on the performance of brine batteries with two different types of electrodes was carried out, namely using magnesium anodes and aluminum anodes. In its cathode part used inert metal or carbon. Variations are carried out on the electrolyte solution used in the form of brine containing Na and Cl ions as electron conductors as well as reductors. Because the reaction of the brine battery system is relatively complex, a study was conducted in this study to see the effect of electrolyte salinity levels (27, 37, and 47 ppt) on the dc voltage produced. The measured parameters include the value of the dc voltage and the resulting current as well as the change in the salinity level after operating for a certain period of time. Tests were performed on batteries to drain the 0.47Ω resistor load operating for 24 hours non-stop where the parameter measurement setup was performed automatically using a PLC. The values of such parameters are monitored and recorded during 24-hour operation. Based on the results of measurements, the average energy capacity that can be used in Mg electrode cells is 17.6% of the total energy generated from the reaction of battery cells, then the average usable battery capacity on the Al electrode cell is 2.6% of the total energy produced.