cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota kupang,
Nusa tenggara timur
INDONESIA
Jurnal Teknik Sipil
ISSN : 20894953     EISSN : 2775815X     DOI : -
Core Subject :
Arjuna Subject : -
Articles 185 Documents
DESAIN SARINGAN PASIR LAMBAT Utomo, Sudiyo; Sir, Tri M. W.; Sonbay, Albert
Jurnal Teknik Sipil Vol 1, No 4 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (267.751 KB)

Abstract

Kolhua IPAB is a means of channeling water to the people and surrounding villages Kolhua, however IPAB has a major problem is turbidity. Slow sand filtration (SPL) is a technique used to improve water quality. Runoff and water quality modeling is obtained by making use of PVC pipe 6 ". Flow rate shall be in accordance with SNI 03.3981.2008 and the resulting water quality after filtration should be below the standard of Minister Regulation. 492 in 2010. Based on the results of research with the discharge of springs Kolhua 0.015 m3/second, SPL design thickness of 60 cm of sand obtained by the speed of 0.22 m/h at head 0.15 m and capacity area of the tub filtering is 245 m2 with dimensions of 11 x 22 m, to the thickness of the sand 80 cm is obtained velocity 0.32 m/h at head 0.25 m and capacity area of the tub filtering is 169 m2 with dimensions of 10 x 20 m, to a thickness of 100 cm of sand obtained by the speed of 0.33 m/h at head 0.30 m and capacity area of the tub filtering is 164 m2 with dimensions of 9 x 18m.
PENGGUNAAN BATU APUNG DARI KABUPATEN LEMBATA Hunggurami, Elia; Touselak, Yosafat Sepriyanto; Kumalawati, A.
Jurnal Teknik Sipil Vol 2, No 2 (2013): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (181.27 KB)

Abstract

The district is an area with the greatest potential pumice in East Nusa Tenggara. Pumice limited usage and the potential availability of the shows that pumice has not been used optimally. Seeing its potential, then another attempt to capitalize on this pumice is used as an alternative to coarse aggregate in normal concrete mix. This will affect the quality of the concrete, so this study aims to determine the compressive strength and split tensile strength of concrete when coarse aggregate in concrete partially substituted by using a pumice stone. Specimens used were as many as 60 concrete cylindrical specimens with 30 MPa compressive strength plan. Pumice stone is used on concrete with substitution of the broken stone. Substitution percentage was 15%, 25%, and 50%. Concrete testing is given 3 different treatment that uses natural pumice stone, pumice stone after the coating as well as the addition of chemicals given in the form of sikafume and sikament Ln. Based on test results, the concrete with substitution levels of 15%, 25%, and 50% lower compressive strength, whereas when given some treatment increases the compressive strength.
PENGARUH MASA PERAWATAN (CURING) MENGGUNAKAN AIR LAUT TERHADAP KUAT TEKAN DAN ABSORPSI BETON Hunggurami, Elia; Utomo, Sudiyo; Wadu, Amy
Jurnal Teknik Sipil Vol 3, No 2 (2014): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (65.664 KB)

Abstract

Dalam proses pembuatan bangunan di daerah pantai, kontak dengan air laut terkadang tidak dapat dihindari. Ditambah lagi dengan keterbatasan pasokan air tawar ke lokasi proyek membuat penggunaan air laut untuk beberapa pekerjaan beton pun dimungkinkan, salah satunya untuk perawatan (curing) beton.Penelitian ini dilakukan untuk mengetahui pengaruh curing air laut terhadap kuat tekan beton dan absorpsi air laut pada beton. Dalam penelitian ini digunakan benda uji beton dengan variasi mutu beton normal yaitu 20 MPa, 25 MPa, dan 30 MPa dengan durasi curing 7 hari, 14 hari, dan 28 hari. Kuat tekan beton yang mengalami curing dengan air laut untuk masa curing 7 hari untuk mutu 20 MPa, 25 MPa, dan 30 MPa secara berturut-turut lebih tinggi 3,18%, 2,65%, dan 1,74% dari pada beton yang mengalami curing dengan air tawar, sedangkan untuk masa curing 14 hari kuat tekan beton yang mengalami curing dengan air laut untuk mutu 20 MPa, 25 MPa, dan 30 MPa secara berturut-turut lebih rendah 4,09%, 2,98%, dan 1,12% dari pada beton yang mengalami curing dengan air tawar, dan untuk masa curing 28 hari kuat tekan beton yang mengalami curing dengan air laut untuk mutu 20 MPa, 25 MPa, dan 30 MPa secara berturut-turut lebih rendah 4,31%, 3,56%, dan 2,85% dari pada beton yang mengalami curing dengan air tawar.
PENGARUH PENAMBAHAN SERAT DAUN GEWANG (CORYPHA UTAN LAM) TERHADAP KUAT LENTUR DAN KUAT TARIK BELAH BETON Ndoen, Vista G.; Sina, Dantje A. T.; Bunganaen, Wilhelmus
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (195.255 KB)

Abstract

Pemanfaatan daun gewang dipilih karena daun gewang dinilai cukup kuat untuk menahan tarik. Berdasarkan hal ini maka daun gewang diproses menjadi serat dan digunakan sebagai bahan tambahan pada beton untuk menambah kekuatan beton.Penelitian ini bertujuan untuk mengetahui pengaruh penambahan serat daun gewang (corypha utan lam) terhadap kuat lentur dan kuat tarik belah beton serta untuk mengetahui persentase penambahan serat daun gewang (corypha utan lam) yang tepat untuk mencapai kuat lentur dan kuat tarik belah maksimum.Benda uji yang digunakan dalam penelitian ini adalah balok beton dengan ukuran 15 x 15 x 60 cm3 dan silinder beton dengan ukuran tinggi 30 cm dan diameter 15 cm. Mutu beton f’c = 25 MPa.Jumlah benda uji 72 buah dengan 3 sampel pada masing – masing waktu dan perlakuan.Sampel – sampel tersebut diberi penambahan konsentrasi serat 0,25%, 0,50% dan 0,75% terhadap berat semen dimana serat – serat tersebut telah direndam dalam alkali NaOH 5% selama 2 jam dengan panjang serat 3 cm. Hasil penelitian menunjukkan bahwa penambahan serat daun gewang pada campuran beton dapat meningkatkan kekuatan beton dan juga dapat menahan patahan beton.Persentase penambahan serat daun gewang sebesar 0,75% mempunyai nilai kuat lentur 5,96 MPa dan nilai kuat tarik belah sebesar 3,94 MPa. Dengan demikian hasil penelitian penambahan serat daun gewang pada campuran beton menunjukkan nilai maksimum kuat lentur dan tarik belah beton terdapat pada penambahan serat gewang dengan persentase sebesar 0,75% pada umur 28 hari. Utilization of gewang leaf been selected because leaf of gewang assessed strong enough to hold then tensile. Based on this, leaf of gewang processed become fiber and used as an additive concrete to increase concrete strong. Purpose of this research are to know about the effect of the addition of leaf fibers gewang (Corypah Utan Lam) to the bending strength and concrete crack tensile strength and also to know an exact presentation of addition of leaf gewang fiber (Corypah Utan Lam) to get the bending strength optimum and crack tensile strength optimum. The test specimen used in this research are beam concrete with size 15x15x60 cm3+ and the heightof cylinder concrete is 30 cm with diameter 15 cm. Concrete quality f’c = 25 Mpa.The number of test specimen with 72 pieces with 3 specimen on each time and treatment. Specimen are given the addition of fiber concentration of 0.25%, 0.50%, and 0.75% by weight of cement where fibers that has been soaked Alkaline NaOH 5% for 2 hours with a fiber length of 3 cm. The result showed that the addition of gewang fiber that used in the concrete mix can increase the strength of concrete and also holding the crack of concrete.Percentage of 0.75% gewangleaf fiber has a bending strength value of 5.96 Mpa and crack tensile strength value divided by 3.94 Mpa. Thus, the result of additional gewang fiber research of the concrete mixture showed the optimum value bending strength and crack tensile concrete are in addition to the percentage of gewang fiber of 0.75% at 28 days.
KOMPONEN STRUKTUR BETON DENGAN PERKUATAN EKSTERNAL Nge, Fredi L.; Pah, Jusuf J. S.; Sir, Tri M. W.
Jurnal Teknik Sipil Vol 5, No 1 (2016): JURNAL TEKNIK SIPIL
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (366.319 KB)

Abstract

Struktur beton seperti balok bila memikul beban yang berlebihan atau tidak sesuai dengan perencanaan awal akan menyebabkan struktur beton tersebut mengalami penurunan daya dukung. Hal ini bisa disebabkan apabila suatu bangunan/struktur tersebut mengalami perubahan/alih fungsi dari yang direncanakan sebelumnya. Penelitian ini dilakukan dengan membuat tata cara perencanaan dari perkuatan eksternal kemudian dibuat benda uji di laboratorium yang digunakan untuk memverifikasi hasil desain dari tata cara perencanaan. Hasil desain dengan menggunakan tata cara perencanaan pada balok beton tulangan tunggal dengan perkuatan eksternal, kapasitas balok dalam memikul momen sebesar 4905467,88Nmm. Hasil pengujian lentur balok di laboratorium diperoleh kekuatan rata-rata dari 3 balok uji dalam memikul momen yaitu sebesar 4843750,00 Nmm. Hasil uji statistik Student T Test dengan tingkat kepercayaan 95% tidak terdapat perbedaan yang signifikan antara hasil desain dan hasil pengujian di laboratorium. Dengan menggunakan tata cara perencanaan, maka hasil desain balok beton tulangan rangkap dengan perkuatan eksternal diperoleh kapasitas balok sebesar 6068337,70Nmm. Hasil pengujian lentur dari 3 balok uji memperoleh kekuatan rata-rata balok dalam memikul momen sebesar 6052083,33 Nmm. Hasil uji statistik Student T Test dengan tingkat kepercayaan 95% menghasilkan perbedaan yang tidak signifikan antara hasil desain dan hasil pengujian di laboratorium.
KINERJA TERMINAL BELLO KUPANG BERDASARKAN KONDISI LALU LINTAS PADA TERMINAL BAYANGAN PEREMPATAN JALUR 40 SIKUMANA-BELLO Frans, John H.; Utomo, Sudiyo; Nubatonis, Marisa N.
Jurnal Teknik Sipil Vol 6, No 1 (2017)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (155.777 KB)

Abstract

Review performance needs to be done because during the last several years, the terminal is not work well,so that people have difficulty to get any transportation for their activities. This research was conducted to find out the feasibility of terminal according the terminal clasification that is Type C,physical performance based on the traffic condition in terminal bayangan, the satisfaction of the customer and the strategy to be implementedto make the terminal work properly.From the result of the feasibility analysis can be concluded that Terminal Bello is quite feasibility to be classified as type C terminal with score equal to 58,93%.The result of physicalperformance analyzes was unsatiesfied yet since from the whole aspect only the location and waiting time that meet the criteria, whereasthe performance considered unsatisfactory which has been evaluated from the road user perception werethe public transportation service and sanitation, from the driver perception were road condition, passengers, information system, parking area, garrage and the regulation of passengers allocation by route. The interview’s result by SWOT quadrant matrix show that Terminal Bello belongs to IV quadrant which means that the terminal is poor to face any big challenge ahead so that the proper strategy needed isminimize weaknesses to avoid threats better
PENGARUH PENAMBAHAN SILICA FUME TERHADAP KUAT TEKAN REACTIVE POWDER CONCRETE Simatupang, Partogi H.; Nasjono, Judi K.; Mite, Kresensia G.
Jurnal Teknik Sipil Vol 6, No 2 (2017): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (225.274 KB)

Abstract

Reactive powder concrete merupakan campuran yang meniadakan agregat kasar. Dalam penelitian ini komposisi dari silica fume adalah 0%, 9%, 18%, 27%, 36% dan 45% dari masa semen. Tujuan dari penelitian ini adalah mengetahui kuat tekan reactive powder concrete akibat penambahan komposisi silica fume dan mengetahui presentase optimal silica fume terhadap kuat tekan beton. Benda uji yang digunakan adalah berbentuk silinder dengan ukuran 5 cm x 10 cm. Setiap variasi terdapat 5 benda uji, sehingga total pengujian adalah 30 benda uji. Dan umur rencana 14 hari.Hasil percobaan I kuat tekan rerata untuk semua variasi yang dihasilkan < 40 MPa, maka dilakukan percobaan II yaitu dengan ditambahkan volume dari superplasticitersebanyak 2 kali data awal. Terdapat 2 benda uji setiap variasi sehingga total keseluruhan adalah 12 benda uji. Hasil percobaan II kuat tekan rerata untuk variasi 0% = 42,02 MPa, 9% =43,29 MPa, 18% = 45,83 MPa, 27% = 48,38 MPa, 36% = 43,29 MPa dan 45% = 42,02 MPa. Presentase optimal silica fumeadalah 26,28%. Reactive powder concrete is a mixture of coarse aggregate negates. In this study the composition of silica fume are 0%, 9%, 18%, 27%, 36% and 45% from weight of the cement. The purpose of this study are knows reactive powder concrete compressive strength due to the addition of silica fume composition and know the optimal percentage of silica fume on compressive strength of concrete.Test object created is cylindrical with the size 5 cm x 10 cm. There are 5 specimen all of the variation. Total of the specimen is 30. And treatment time’s 14 days.The result of the first experiment a mean compressive strength for all of variationare smaller than 40 MPa then conducted second experiment. At the experiment added volume of superplasticiter 2 times first experiment.There are two specimen all of the variation so have 12 specimen’s. The result of the second experiment a mean compressive strength for a variation 0% = 42,02 MPa, 9% =43,29 MPa, 18% = 45,83 MPa, 27% = 48,38 MPa, 36% = 43,29 MPa and 45% = 42,02 MPa. Optimal percentage of silica fume are 26,28%.
MODEL PERENCANAAN BANGUNAN SABO UNTUK PENGENDALIAN ALIRAN DEBRIS (DEBRIS FLOW) Udiana, I Made
Jurnal Teknik Sipil Vol 1, No 1 (2011)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (487.059 KB)

Abstract

ABSTRAKPengembangan aplikasi teknologi Sabo untuk pengendalian aliran sedimen di Indonesiatidak terbatas hanya di daerah vulkanik saja, akan tetapi juga di daerah non vulkanik.Model perencanaan sabo untuk pengendalian aliran debris (debris flow) ini merupakansuatu model perencanaan Sabo yang diatur untuk melindungi sasaran yang berpencaratau tersebar memanjang di daerah hilir sungai kecil.Metode yang digunakan untuk memformulasikan Perencanaan Sabo (pengendaliansedimen) agar dapat mengurangi akibat bencana tersebut yaitu: metode kuantitatif danmetode kualitatif. Hasil kajian menunjukkan, bahwa : (1) Untuk penanggulangan alirandebris (pasir dan krikil) adalah dengan bangunan Sabo; (2) Aliran debris disebabkanoleh pengaliran air yang berlangsung pada permukaan lapisan endapan pada dasarsungai; (3) Untuk memformulasikan Perencanaan Sabo suatu DAS tertentu, mula-mulaharus ditentukan suatu titik referensi (Sabo Basic Point); (4) Penentuan skalaperencanaan pengendalian sedimen sangat tergantung pada jenis sumber, cara estimasisedimen yang mengalir dan tingkat bahayanya; (5) Prinsip perencanaan Sabo adalahmembuang sejumlah material debris/sedimen yang mengalir sepanjang sungai di daerahhilir; (6) Fasilitas bangunan Sabo yang dapat diterapkan untuk pengendalian sedimenmeliputi: dam pengendali, tanggul, kantong pasir, saluran pengatur kanal, tanggulterbuka dan perlindungan tebing.
PENGARUH PENGGANTIAN SEMEN OLEH ABU SABUT BUAH SABOAK TERHADAP KEKUATAN MORTAR Karya, Muhamad Y.; Hangge, Elsy E.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 7, No 2 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (442.255 KB)

Abstract

Pohon saboak banyak tumbuh di Pulau Timor tetapi masyarakat belum bisa mengolah dengan baik limbah dari buah saboak tersebut. Abu sabut buah saboak diperoleh dari hasil pembakaran sabut buah saboak, dimana memiliki kandungan silikat dan berpotensi untuk dijadikan alternatif sebagai bahan pengganti campuran pembuatan mortar. Tujuan penelitian ini adalah mengetahui sejauh mana pengaruh penggantian semen dengan abu sabut buah saboak terhadap kuat tekan mortar. Penelitian dilakukan dengan membuat benda uji kubus ukuran 5 cm x 5 cm x 5 cm dengan perbandingan penggantian abu sabut buah saboak 0%, 2,5%, 5%, 7,5%, 10% pada campuran mortar. Setiap persentase campuran menggunakan 5 buah benda uji, yang ditinjau pada umur 7 hari, 14 hari, 21 haridan 28 hari. Hasil pengujian kuat tekan beton menunjukkan bahwa nilai kuat tekan optimum terjadi pada komposisi penggantian abu sabut buah saboak 2,5% dengan peningkatan maksimum kuat tekan sebesar 12,72 MPa pada umur mortar 28 hari. Nilai kuat tekan dibandingkan terhadap mortar  normal, mortar dengan tambahan abu sabut saboak 2,5% dapat meningkat sebesar 5,66%. Berdasarkan SNI 03-6882-2002(DPU, 2002) mortar pada penelitian ini tergolong mortar tipe S dengan kuat tekan minimumnya 12,5 MPa, cocok digunakan sebagai bahan pembuat bataringan, batako dan plesteran tembok bagian dalam maupun luar.Saboak trees are grown on Timor Island but the community can not properly cultivate the waste from the saboak fruit saboak. Fibers of saboak husk are obtained from the burning of saboak saber, which has silicate content and has the potential to be used as a substitute for mortar mixture. The purpose of this research is to know how far the influence of cement replacement with saboak husk ash to mortar compressive strength. This research is done by making the cube specimen size 5 cm x 5 cm x 5 cm by using the comparison of saboak saboak root replacement 0%, 2 , 5%, 5%, 7.5%, 10% on the mortar mixture. At each percentage of mixture using 5 test specimens, reviewed at 7 days, 14 days, 21 days and 28 days of mortar age. The result of concrete compressive strength test showed that the optimum compressive strength value occurred in the composition of 2.5% saboak saboak ash substitution with a maximum increase of compressive strength of 12.72 MPa at 28 days of mortar age. The compressive strength value was compared to normal mortar, mortar with 2.5% saboak ash ash can be increased by 5.66%. Based on SNI 03-6882-2002(DPU, 2002) mortar in this research classified mortar type S with minimum compressive strength 12,5 MPa, suitable to be used as material of light brick, brick and plastering of inner and outer wall.
ANALISA INDEKS BIAYA UNTUK PEKERJAAN BETON BERTULANG DENGAN MENGGUNAKAN METODE SNI 7394-2008 DAN LAPANGAN (Studi Kasus pada Proyek Pembangunan Asrama STIKES CHMK Tahap III) Messah, Yunita A.; Sina, Dantje A. T.; Manubulu, Christiani C.
Jurnal Teknik Sipil Vol 2, No 1 (2013): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (430.801 KB)

Abstract

The index cost affect the amount of unit price construction work. Cost index used in the calculation analysis of unit price refers to the Standar Nasional Indonesia (SNI). SNI describe about the average labor productivity in Indonesia. Labor productivity are different depend on work experience, cultural origins, and the others. This study was conducted to know the costs index of labor in Kupang by took one of case study on STIKES CHMK Dormitory Construction Project in third Phased. Cost index of reinforced concrete in this project, obtained by doingreal observation for the total of labor and time required to complete each item of reinforced concrete, especially the workfrom column,beam and plate and it began from the work of iron, formwork, casting up to demolition formwork.Then the observationsresult were analyzed descriptively. Based on the analysis result, the amount of the cost index is 0.0208 foreman: 0.0377 the head of handyman: 0.09929 handyman: 0.2502 worker to install 1m2 formwork, 0.0044 foreman: 0.0177 the head of handyman: 0.0268 handyman : 0.0796 worker to work 10 kg iron, and 0.0340 foreman: 0.0272 the head of handyman: 0.1427 handyman: 1.1888 worker to make 1m3concrete. This index used in the analysis of the differentation of labor presentage based on SNI and field method and continued with the calculation of unit price for each work item which used SNI and field method.