cover
Contact Name
Ariyawan Sunardi
Contact Email
dosen00332@unpam.ac.id
Phone
-
Journal Mail Official
epic@unpam.ac.id
Editorial Address
-
Location
Kota tangerang selatan,
Banten
INDONESIA
EPIC : Journal of Electrical Power, Instrumentation and Control
Published by Universitas Pamulang
ISSN : 26150646     EISSN : 26148595     DOI : -
Core Subject : Engineering,
Jurnal EPIC merupakan wadah komunikasi ilmiah antara akademisi maupun praktisi terkait penelitian di bidang teknik elektro.
Arjuna Subject : -
Articles 209 Documents
Optimalisasi unjuk kerja mesin reverse osmosis portable untuk aplikasi hemodialisa melalui integrasi nanofilter dengan analisis beban energi darmawan, muhammad rahmat; Kiswanta
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58386

Abstract

Mesin reverse osmosis portable adalah komponen penting dalam proses hemodialisa untuk menyediakan air dialisat, terutama di ruangan perawatan yang tidak memiliki instalasi air reverse osmosis. Permasalahan berulang yang dihadapi adalah penurunan debit air produk di bawah standar minimum (500 ml/menit), yang menyebabkan terhentinya pelayanan hemodialisa berisiko bagi keamanan dan kenyamanan pasien selama menjalani proses hemodialisa, dan meningkatkan biaya penggantian komponen filter/membran. Penelitian ini bertujuan untuk melakukan optimalisasi pada mesin reverse osmosis Portable guna meningkatkan keamanan pasien, menghitung efisiensi biaya penggantian media filter dan membrane setelah modifikasi, analisa penggantian media filter, analisa kinerja alat monitoring water flow sensor, dan analisa kualitas air setelah dilakukan optimalisasi. Optimalisasi yang dirancang dan diimplementasikan mencakup tiga aspek, penggantian filter karbon 5 mikron menjadi filter sedimen 0.22 mikron, perubahan instalasi membran dari konfigurasi paralel-seri menjadi tiga membran yang dihubungkan secara parallel, dan penambahan sistem monitoring debit air real-time. Sistem monitoring ini dikontrol oleh microcontroller arduino uno r3 dan menggunakan water flow sensor YSF402B. Sistem akan menampilkan data debit pada LCD dan mengaktifkan alarm (buzzer dan lampu indikator) jika debit air turun di bawah batas aman 600 ml/menit. Hasil pengujian menunjukkan bahwa optimalisasi ini berfungsi dengan baik. Kinerja mesin reverse osmosis Portable setelah modifikasi menunjukkan kualitas air produk selalu di masuk baku mutu. Selain itu, modifikasi ini secara signifikan menurunkan frekuensi penggantian media filter dan membran. Dalam periode 3 bulan setelah optimalisasi, membran tidak memerlukan penggantian , yang membuktikan bahwa rancangan optimalisasi ini sangat efektif dan efisien dalam meningkatkan keamanan pelayanan sekaligus menghemat biaya operasional
Uji Kelayakan Instalasi Listrik Tiga Fasa dan Sistem Proteksi Berdasarkan PUIL 2011 Pada Tempat Ibadah Falah, Arif; Abdul Rozak, Ojak
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58496

Abstract

Energi listrik merupakan energi primer yang menjadi kebutuhan untuk beraktivitas sehari–hari. Di Indonesia, sistem 1 fasa 220 V/50 Hz umum digunakan, namun untuk beban besar seperti rumah ibadah, diperlukan sistem 3 fasa. Penelitian ini menguji kelayakan instalasi listrik 3 fasa 20 kVA di Masjid Baitussalam melalui analisis ketidakseimbangan beban dan rating proteksi sesuai PUIL 2011. Hasil perhitungan menunjukkan beban total operasional sebesar 13.472,22 Watt dengan arus nominal 24,1 A dan KHA 30,125 A. Ditemukan ketidakseimbangan beban sebesar 42,3%, yang melebihi batas maksimal 30% menurut IEEE 1159-2009. Hal ini mengindikasikan perlunya penataan ulang distribusi beban dan penyesuaian sistem proteksi agar sesuai standar PUIL guna menjamin kehandalan sistem.
Analysis of Voltage Drop and Illuminance Performance in 24 VDC LED Lightning System Using Different Driver Capacities Nuryana, Muhammad Risqi; Assubhi, Moh Hanif
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58505

Abstract

This study examines how driver capacity influences voltage distribution and illuminance in a 24 VDC LED lighting installation. In many practical projects, differences in driver ratings are often assumed to have minimal impact as long as the load requirement is satisfied; however, voltage drop along the cable may affect the actual performance at the luminaire. An experimental measurement was conducted using identical LED fixtures connected through a 12-meter cable while varying the driver capacities at 20 W, 35 W, and 100 W. For each configuration, the output voltage from the driver, the voltage received at the LED terminals, and the resulting illuminance were recorded after stable operating conditions were reached. The observations show that higher driver capacity tends to provide slightly better voltage regulation at the load side, and this improvement is followed by an increase in measured illuminance. Although the voltage differences are relatively small, the trend consistently indicates the importance of proper driver selection in maintaining system effectiveness, especially in low-voltage installations with distribution distance. The results are expected to serve as a practical reference for electrical and lighting engineers in determining suitable driver specifications to achieve reliable and optimal lighting performance.
Analisis Pelanggaran Oleh Pelanggan dan Bukan Pelanggan PLN dalam Penertiban Pemakaian Tenaga Listrik Anisa Atul Ngalima; Ozak Abdul Rozak
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58512

Abstract

Susut energi listrik merupakan selisih antara energi listrik yang disalurkan melalui jaringan distribusi dengan energi listrik yang tercatat pada meter pelanggan. Susut energi listrik dibedakan menjadi susut teknis dan susut non-teknis. Susut teknis disebabkan oleh faktor teknis pada jaringan distribusi, sedangkan susut non-teknis umumnya disebabkan oleh kesalahan pencatatan meter dan penggunaan tenaga listrik secara tidak sah.Penelitian ini bertujuan untuk menganalisis besaran susut energi listrik pada beberapa gardu distribusi di wilayah kerja UP3 Lenteng Agung serta mengidentifikasi penyebab utama terjadinya susut energi listrik. Metode yang digunakan adalah analisis perbandingan antara energi listrik yang keluar dari gardu distribusi (kWh gardu) dengan energi listrik yang tercatat pada meter pelanggan (kWh OLAP), serta pemeriksaan lapangan melalui kegiatan Penertiban Pemakaian Tenaga Listrik (P2TL). Hasil analisis menunjukkan bahwa dari delapan gardu yang diteliti, terdapat tiga gardu dengan tingkat susut energi yang signifikan, yaitu Gardu LTA2 dengan susut sebesar 37.764 kWh (21,99%), Gardu LTA4 sebesar 17.508 kWh (13,83%), dan Gardu LTA8 sebesar 36.534 kWh (33,38%). Berdasarkan hasil pemeriksaan P2TL, ditemukan lima kasus pelanggaran, yang terdiri dari satu pelanggan dengan pelanggaran Golongan I (PI), dua pelanggan dengan pelanggaran Golongan III (P III), serta dua kasus pelanggaran Golongan IV (P IV) yang dilakukan oleh bukan pelanggan.Penerapan program Penertiban Pemakaian Tenaga Listrik (P2TL) terbukti menjadi salah satu upaya yang efektif dalam mendeteksi dan menekan susut non-teknis. Diharapkan hasil penelitian ini dapat menjadi bahan evaluasi bagi PT PLN (Persero) dalam meningkatkan efisiensi distribusi energi listrik dan mengurangi kerugian akibat susut energi.
Enhancing IT/OT Security Posture Against Erlang/OTP SSH Exploits Through Threat Campaign Assessment Nabila Latifa Tullaili; Ridwan Satrio Hadikusuma; Aries Suharso
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58567

Abstract

The convergence of Information Technology (IT) and Operational Technology (OT) infrastructures exposes organizations to new risks, particularly when facing critical vulnerabilities. This research evaluates the security posture of IT/OT environments against CVE-2025-32433, a severe vulnerability in Erlang/OTP’s SSH daemon that allows unauthenticated remote code execution. The assessment was conducted in a real environment using the Keysight Threat Simulator, where simulated threats were injected from the darkcloud, passed through a Palo Alto Networks firewall, and targeted a host system (Windows Server 2016) with Keysight Agent version 25.7.3-1751647889 and ATI version 25.5.4181.502994. This campaign involving seven malware scenarios using remote hosts and DNS callbacks. The results showed 43 prevention outcomes, 0 detection events, and 9 security recommendations. While the firewall prevented part of the attacks, the detection capability at the host level failed entirely, indicating potential blind spots in monitoring and response.The study concludes that proactive threat simulation is essential for identifying prevention gaps and detection weaknesses in converged IT/OT networks. Recommendations include strengthening host-based detection, improving IT/OT segmentation, and enhancing monitoring of DNS traffic to mitigate exploitation risks.
Implementasi Sistem Automatic Meter Reading (AMR) untuk Deteksi Anomali Pembacaan kWh Meter Tiga Fasa Muhamad Dedi Sofyan; Triyanto, Aripin; Dinata, Seflahir; Edy Sumarno; Wawan Gunawan
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 2 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i2.58213

Abstract

Listrik saat ini merupakan energi yang paling signifikan. PT. PLN (Persero), perusahaan Indonesia yang memasok dan menjual listrik, menggunakan meter kWh untuk membeli dan menjual listrik kepada konsumen. Pengguna daya besar yang menggunakan teknologi Automatic Meter Reading (AMR) untuk pengukuran energi berisiko mengalami gangguan. Energi listrik tidak tercatat akibat gangguan dalam transfer data meter kWh pelanggan ke sistem pusat data. Peralatan atau sistem pemeliharaan yang tidak memadai mungkin menjadi sumber gangguan tersebut. Konsumen PLN menggunakan aplikasi AMICON untuk melihat hasil pembacaan meter kWh pelanggan dari jarak jauh guna menentukan apakah terjadi pemadaman listrik. Pembacaan data dari aplikasi AMICON akan diperiksa di area kerja Unit Pelaksana Layanan Pelanggan (UP3) Kebon Jeruk dengan pembatasan daya 23.000 VA hingga 24 MVA. Ditemukan bahwa antara Maret 2024 dan Agustus 2024, kejadian arus yang tidak terukur pada meter kWh menyebabkan kerugian sebesar 21.200 kWh menggunakan metode kuantitatif deskriptif dengan data langsung AMR, ditambah dengan pendekatan berdasarkan pembayaran bulanan pelanggan. Diharapkan bahwa pemeliharaan preventif rutin akan mengurangi kerugian energi listrik. Banyak klien dengan energi yang tidak terukur ditemukan sebagai akibat dari kerusakan modem.
Analisis Performa Motor Induksi Tiga Fasa Pada Kondisi Beban Penuh dan Tanpa Beban Fauzan, Wisda; Sumarno, Edy; Bachtiar, Muhamad Rizky
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58633

Abstract

Motor induksi tiga fasa banyak digunakan dalam sistem industri karena memiliki konstruksi sederhana, keandalan tinggi, dan perawatan yang relatif rendah. Performa motor sangat dipengaruhi oleh kondisi pembebanan yang berdampak pada parameter kelistrikan dan mekanik. Penelitian ini bertujuan untuk menganalisis performa motor induksi tiga fasa tipe rotor belitan pada kondisi tanpa beban dan beban penuh berdasarkan hasil pengujian langsung di lapangan. Metode penelitian menggunakan pendekatan kuantitatif eksperimental dengan pengukuran arus, daya semu, daya aktif, daya reaktif, faktor daya, dan kecepatan rotor. Hasil pengujian menunjukkan bahwa peningkatan beban menyebabkan kenaikan arus stator, daya semu, daya aktif, dan daya reaktif secara linier, sedangkan kecepatan rotor relatif konstan pada kisaran 2900 rpm. Kondisi tanpa beban menunjukkan konsumsi daya didominasi oleh daya reaktif dan rugi-rugi internal. Hasil ini menunjukkan bahwa pembebanan berpengaruh signifikan terhadap performa dan efisiensi motor induksi tiga fasa. Kata kunci: motor induksi tiga fasa, rotor belitan, beban penuh, tanpa beban, performa motor
Optimasi Sudut Kemiringan Modul Surya untuk Maksimalisasi Daya Keluaran PLTS dari Studi Kasus di PT. Damai Elektrik Indonesia Yusda Mardiawan; Juhana
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58675

Abstract

Daerah yang terletak di sekitar garis ekuator memiliki intensitas penyinaran matahari yang tinggi dan relatif konsisten sepanjang tahun, sehingga menyimpan potensi besar untuk pengembangan energi surya. Kondisi tersebut menjadikan Pembangkit Listrik Tenaga Surya (PLTS) sebagai solusi yang prospektif dalam menjawab peningkatan kebutuhan energi listrik serta mendukung pengurangan penggunaan bahan bakar fosil. Meskipun demikian, performa sistem PLTS sangat bergantung pada posisi pemasangan modul, khususnya sudut kemiringan terhadap arah datang radiasi matahari. Ketidaktepatan dalam menentukan sudut instalasi dapat mengurangi intensitas radiasi yang diterima modul sehingga berdampak pada penurunan daya keluaran. Penelitian ini dilakukan untuk mengevaluasi pengaruh variasi sudut kemiringan terhadap daya output modul surya sekaligus mengidentifikasi sudut yang paling optimal berdasarkan kondisi geografis lokasi penelitian. Metode yang diterapkan berupa pengujian eksperimental menggunakan modul surya jenis polycrystalline dengan kapasitas 20 Wp. Variasi sudut yang dianalisis adalah 0°, 15°, 30°, dan 45°. Pengukuran dilakukan setiap satu jam mulai pukul 09.00 hingga 15.00 WIB dengan mencatat parameter tegangan, arus, serta daya baik pada sisi modul maupun inverter. Hasil eksperimen menunjukkan bahwa konfigurasi kemiringan 15° memberikan kinerja paling optimal dengan rata-rata tegangan sebesar 20,82 V, arus 0,06 A, dan daya modul 1,19 W. Nilai tersebut lebih tinggi dibandingkan sudut 0° (0,70 W), 30° (0,75 W), dan 45° (0,37 W). Pada pengujian sisi inverter dengan beban 20 W, sudut 15° juga menghasilkan daya rata-rata tertinggi sebesar 38,91 W. Dengan demikian, sudut kemiringan 15° direkomendasikan sebagai posisi pemasangan yang paling efektif untuk lokasi penelitian ini.
Implementation of Constraint Satisfaction Problem Approach for Solving the Zebra Puzzle with Prolog Tri Bagus Kurniawan; Muhammad Risqi Nuryana; Bijokangko, Resi Sujiwo
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 2 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i2.58721

Abstract

Constraint Satisfaction Problem (CSP) Is a fundamental concept in artificial intelligence used to solve combinatorial problems by satisfying a set of constraints. The Zebra Puzzle is a classical example that involves assigning attributes such as nationality, house color, pet, drink, and candy to five houses based on logical clues. This study aims to implement CSP techniques using the Prolog programming language to solve the Zebra Puzzle. The methodology includes classifying all relevant attributes, encoding constraints into Prolog predicates, and applying helper functions to represent adjacency and ordering relationships. The puzzle is modeled as a list of structured facts, and Prolog’s inference engine is used to derive consistent solutions. The program successfully assigns all attributes to the correct house positions. For example, the Englishman lives in the red house, the Spaniard owns the dog, and the Ukrainian drinks tea. The Norwegian lives in the first house and drinks water, while the Japanese owns the zebra. These results confirm the effectiveness of Prolog in solving structured logic puzzles using CSP. The study concludes that logic programming is a reliable tool for modeling and solving constraint-based problems. This implies broader applicability of CSP in intelligent systems.
Metode Thresholding Otsu untuk Klasifikasi Awal Vitiligo dan Hyperpigmentation Berdasarkan Luas Piksel Putra Alvaro, Rayhan; Rahmadewi, Reni
EPIC Journal of Electrical Power Instrumentation and Control Vol 8 No 1 (2025): EPIC
Publisher : Universitas Pamulang, Prodi teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32493/epic.v8i1.58841

Abstract

Penelitian ini mengembangkan sistem deteksi kelainan pigmentasi kulit menggunakan metode Otsu Thresholding dan analisis jumlah piksel pada citra biner. Sistem dibuat dalam bentuk Graphical User Interface (GUI) MATLAB sehingga memudahkan pengguna dalam melakukan input citra, cropping, pra-pemrosesan, segmentasi, dan klasifikasi. Dataset terdiri dari 30 citra yang mencakup 15 citra vitiligo dan 15 citra hiperpigmentasi. Tahap pra-pemrosesan dilakukan melalui konversi grayscale dan Gaussian smoothing untuk menstabilkan intensitas sebelum segmentasi otomatis oleh metode Otsu. Hasil segmentasi dianalisis melalui perhitungan jumlah piksel putih dan hitam untuk menentukan jenis kelainan. Hasil pengujian menunjukkan akurasi 100% untuk vitiligo dan 80% untuk hiperpigmentasi. Secara keseluruhan sistem mencapai akurasi 90% dan dapat digunakan sebagai pendekatan awal deteksi kelainan pigmentasi kulit.