RANCANG BANGUN MANOMETER DIGITAL BERBASIS MIKROKONTROLER ATMEGA 8 ., Dedi Supriadi
Jurnal Teknik Elektro Universitas Tanjungpura Vol 1, No 1 (2013): Jurnal Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Kelemahan dari alat ukur manometer analog yaitu masih menggunakan panel jarum konvensional sehingga terjadinya kesalahan pembacaan data tekanan udara kemungkinan besar akan terjadi. Untuk mengatasi kekurangan-kekurangan pada alat ukur manometer tersebut maka penulis berinisiatif untuk merancang sebuah alat ukur tekanan udara digital. Sistem yang akan dibuat dapat mengukur tekanan udara dalam 3 mode pengukuran yaitu mode Gauge, mode Absolute serta mode Differential. Penggunaan manometer digital diharapkan mampu membaca tekanan udara dengan tingkat galat (error) yang relatif kecil. Alat yang dibuat dapat menampilkan nilai hasil pengukuran pada LCD dan sebagai indikator peringatan bahwa tekanan telah maksimum menggunakan buzzer yang akan berbunyi, serta menampilkan satuan tekanan dalam tiga satuan, yaitu satuan kPa, Psi dan Bar. Hasil pengujian alat menunjukkan nilai rata-rata galat (error) pada satuan pengukuran Psi sebesar 0.116 atau 0.425% dan pada satuan kPa 0.921 atau 0.426% serta satuan Bar 0.009 atau 0.424%. Kata kunci : Manometer Digital, Sensor Tekanan, Mikrokontroler
PERENCANAAN KEBUTUHAN BTS DALAM PENERAPAN MENARA BERSAMA DI KABUPATEN MEMPAWAH Pratomo, Muhammad Riski; Imansyah, Fitri; Marpaung, Jannus
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2020): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Peranan telekomunikasi telah menjadi bagian yang tidak dapat dipisahkan dalam berbagai aspek kehidupan, pihak penyedia layanan seluler berlomba-lomba untuk berinovasi untuk memberikan pelayanan yang terbaik contohnya dengan membangun menara telekomunikasi. Untuk merencanakan kebutuhan BTS dalam penerapan menara bersama harus memperhatikan beberapa parameter-parameter yang berpengaruh pada kebutuhan menara bersama. Kebutuhan menara bersama dapat dicapai dengan memprediksi jumlah penduduk pada wilayah Kabupaten Mempawah kemudian dengan mencari prediksi pengguna selular dengan menggunakan teledensitas Indonesia lalu menghitung kebutuhan trafik kemudian dihitung kapasitas satu BTS untuk menampung trafik dari pelanggan sehingga didapatkan hasil perencanaan kebutuhan BTS dalam penerapan menara bersama. Hasil yang didapatkan adalah pada tahun 2020 terdapat 78 menara bersama dengan total jumlah BTS sebanyak 234 buah. Dan untuk total jumlah kebutuhan tahun 2025 yakni 83 menara bersama dan BTS sebanyak 250 buah. Sehingga diperlukan optimasi untuk penerapan menara bersama di Kabupaten Mempawah.
ANALISA PENGGUNAAN SPEKTRUM FREKUENSI PADA JARINGAN CDMA (CODE DIVISION MULTIPLE ACCESS) DAN GSM ( GLOBAL SYSTEM FOR MOBILE COMMUNICATION) DI PT. INDOSAT TBK ., Adi Kurniawan
Jurnal Teknik Elektro Universitas Tanjungpura Vol 1, No 1 (2014): Jurnal Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini membandingkan antara penggunaan spektrum frekuesi CDMA dengan GSM, dimana pengambilan studi kasus penelitian dilakukan di PT. Indosat Tbk. Alat yang digunakan dalam pengukuran spektrum frekuensi tersebut adalah menggunakan Spectrum Analyzer. Pengaruh interferensi downlink CDMA terhadap uplink GSM pada alokasi spektrum bersama di PT. Indosat Pontianak mengalami interferensi Co-Channel. Hal ini disebabkan karena bekerja pada alokasi frekuensi yang sama, mengakibatkan tabrakan sinyal sehingga terjadi interferensi yang mengurangi kualitas sinyal. Jadi solusi yang dapat dilakukan untuk mengatasi gangguan interferensi pada spektrum frekuensi CDMA dan GSM, yaitu:1) Melakukan pemilihan kanal yang sesuai atau yang cocok antara kanal GSM dan CDMA agar tidak terjadi interferensi, hal itu dilakukan karena kedua kanal memiliki frekuensi kerja yang berdekatan sehingga tidak saling mengganggu; 2) Memperbesar jarak antara kanal agar tidak terjadi interferensi pada kanal yang sama (co-channel interference); 3) Mengurangi daya pancar atau mengatur daya pancar agar tidak melebihi dari standarisasi; 4) Menggunakan antena sektoral dan mengatur sudut kemiringan antena agar pola radiasinya dapat terarah dan tidak terjadi interferensi. Untuk itu dalam menyempurnakan desain, data pengukuran dan analisa yang dihasilkan adalah: 1) Perawatan alat-alat BTS harus dilakukan secara berkala minimal 6 (enam) bulan sekali, bila terjadi kerusakan pada salah satu peralatan BTS harus cepat dilakukan perbaikan agar tidak menyebabkan kerusakan yang lebih parah; 2) Untuk menjauhkan dari masalah interferensi, sebaiknya tidak melakukan sistem Co-Location dan Co-Tower. Walaupun biayanya agak sedikit mahal, tapi hal ini bisa menjauhkan dari masalah interferensi; 3) Perlunya dilakukan studi lebih lanjut tentang alokasi frekuensi kerja baik GSM maupun CDMA dan penomoran channel agar tidak terlalu rapat; 4) Mengatur penggunaan daya kontrol transmisinya tidak melewati batas maksimum, agar tidak terjadi tabrakan frekuensi; 5) Melakukan alokasi kanal yang sesuai untuk tiap sel BTS agar pada saat terjadi pengulangan frekuensi tidak terjadi tabrakan atau interferensi yang mengganggu kualitas sinyal; 6) Perlunya penelitian lebih lanjut dalam skripsi ini yaitu untuk melakukan proses optimasi dalam meningkatkan dan memelihara performansi jaringan. Kata Kunci : Spectrum Analyzer, Co-Channel Interference, Adjacent Channel Interference.
Analisis Perencanaan Pembagian Beban Dan Instalasi Listrik Pada Hotel Golden Tulip Di Kota Pontianak ., Edi Ridwan
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2015): Jurnal S1 Teknik Elektro
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

One of building sector which is developing in Pontianak city is the raise of hotels in the center city. Hotel needs large enough electric energy. It’s proved by the used of transformator capacity, till 1250 KVA and the use of genset as big as 1000 KVA. This must be followed by a good and efficient electric distribution to get high electric energy supply. The hotel building that become a research object  in Pontianak city is located in Jl. Teuku umar is Golden Tulip. It stand on 11 floors that consume big enough electric energy. This hotel has had a good distribution system, effectif and efficient instalation such as balance dividing load, safe and standart electric instalation, PUIL 2000 and professional  electric system to minimize the waste of electric energy while distribution because of the loses power. Based on accounting result, data analiz, dividing load and electric instalation in hotel Golden Tulip Pontianak must be divided and categoried spread evenly between stand by load and unstand by load to get the balance dividing load, otherwise on the measuring result in the basemant floor until five floor, there is unbalance load that cause by the unspread evenly load categories to get the safe MCB result, MCCB and grounding cabel is different with planning result. This is happened because 1 feeder pull for 3 different  panel in basemant floor, 1st floor  and 2nd floor. Same cases with the 3rd floor panel, 4th floor and 5th floor only need 1 feeder  pull. Based on planning analize result for the effeciency distribution of electric power can be done by 1 feeder  pull directly to each panel / floor.   Keyword : Load dividing, electric instalation, PUIL 2000.
PENGENDALI ADAPTIVE NEURO FUZZY INFERENCE SYSTEM (ANFIS) UNTUK PENGATURAN KESTABILAN PADA SISTEM WARD LEONARD ., Ricky Budi Setiawan Pinaria
Jurnal Teknik Elektro Universitas Tanjungpura Vol 1, No 1 (2018): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The development of control technology has progressed considerably from classical control to automatic controls to intelligent controls. ANFIS is Adaptive Neuro Fuzzy Inference System one of intelligent control techniques that are capable as well as human capabilities. In this study aims to test the  ability  of  ANFIS  controller  on  Ward  Leonard  system  speed  control.  The  design  of  ANFIS controller and Ward Leonard system to be tested using Matlab and Simulink on Matlab by collecting Maximum Overshoot data and Steady State time on Ward Leonard system condition without controller and with ANFIS Controller controller. Results Ward Leonard system without a controller takes 4.32 seconds for the main driving motors reach steady state and 2.013 seconds for the load motor can reach steady state. The unattended Ward Leonard system has a Maximum Overshoot value of 62.2% on the Main Movement Motor and 78.5% on the Load Motor. The Ward Leonard system with ANFIS controller with a unit feedback system on the main Move Motors can reach a steady state time of4,809 seconds and for the 5.55 seconds required by the Load Motor to reach the steady state. The Ward Leonard system with the ANFIS controller has Maximum Overshoot value of each of the main Driving Motor and the Motor load of 0.3%. Factors that cause steady state time of Ward Leonard system condition with ANFIS controller and condition of Ward Leonard system without controller is ANFIS controller which takes a relatively longer time to muffle error based on membership function of existing ANFIS controller. Keywords: ANFIS controller, Ward Leonard system, Maximum Overshoot, Steady State.
PERANCANGAN DAN ANALISA CIRCULAR POLARITY ANTENNA CROSSHAIR WAVEGUIDE SEBAGAI PENGUAT WIFI ADAPTER TP-LINK TL-WN723N PADA FREKUENSI 2,4 GHZ ., Yulianus Sandi
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2016): Jurnal Mahasiswa Prodi Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak  - Waveguide  Crosshair Antenna   with   reflectors   which   has   the function to change the radiation pattern and beam width antenna beam so that in itself could increase the antenna gain. The amount of  change  in  the  gain  generated  by  the addition of the reflector can be affected by several things, among them is to set the size of the  reflector  panel  angle  (α),  adjust  the amount of spacing between the driven element and reflector panel (space), and change the length dimension of the reflector (h). The resulting radiation pattern     waveguide Crosshair antenna is directional, the signal emitted in two directions with the same magnitude.  With  the  addition  of  reflectors, will limit the radiation pattern from being widened backward and transmits force will be strengthened in the opposite direction, so that one  can  clearly  see  how  it  changes  the transmit antenna patterns before and after the addition  of  the  reflector,  the  antenna amplifier is more devoted to the working frequency of 2.4 GHz for wireless LAN ( local area network ). The parameters that must be considered in designing antennas for wireless LAN is working frequency. To test the speed of the download (download) and upload (upload), conducted through speedtest.net on two different networks, namely network UNTAN hotspot network in the faculty of engineering with download speeds of 72.23 Mbps, 50.56 Mbps upload network and the Faculty  of  Engineering  at  the  speed  3.05 Mbps download, upload 2.13 Mbps, which is influenced by the speed  speedtest maximum value and minimum speed provided by the ISP (internet Service Provider). Kata kunci: Crosshair Waveguide Antenna, External Antenna, Wifi Adapter frekuensi 2.4 GHz
RANCANG BANGUN SCORING BOARD MENGGUNAKAN SMS (SHORT MESSAGE SERVICE) BERBASIS MIKROKONTROLER ATMEGA 32 ., Zeky Leo Karza
Jurnal Teknik Elektro Universitas Tanjungpura Vol 1, No 1 (2013): Jurnal Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrack: Scoring Board via SMS is a microcontroller-based system that can be used to provide information about the results of football matches, both scor match results and team names that match. To input the name of the team in the scoring system board must send a sms with a given format ie "A team name and team name B". There are other commands with different command functions also vary. Conditioned system created by the network provider Telkomsel, as well as mobile phones used in the system is the Siemens C45 mobile phone. Unit controller used in the scoring system board is ATMEGA32. Keywords : scoring board, mikrokontroller ATmega32, Siemens C45, sevent segment.
STUDI ENERGY RETURN OF INVESMENT PLTU (BATUBARA) DI KABUPATEN BENGKAYANG Misli, -; Hiendro, Ayong; Suryadi, Dedy
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2020): Jurnal S1 Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Standar Energy Return Of Invesment (EROI) > 0 untuk menentukan layak atau tidaknya dalam investasi energi di Pembangkit Listrik Tenaga Uap (PLTU). Nilai EROI harus bernilai positif sehingga layak dalam investasi energi di PLTU. Penelitian ini dapat digunakan untuk penentuan nilai EROI di PLTU 2x50 MW. Lokasi penelitian ini di laksanakan di Kabupaten Bengkayang, metode yang digunakan adalah metode Energy Return Of Invesment (EROI). Hasil penelitian di PLTU 2x50 MW di Kabupaten Bengkayang nilai EROI (H) bernilai positif sebesar 1,416705 berkerjasama dengan PT. Bukit Asam sebagai supplier bahan bakar batubara. Dari hasil EROI tersebut maka PLTU 2x50 MW Batubara di Kabupaten Bengkayang ini saat sekarang masih layak.
ANALISIS PERBANDINGAN POWER TRANSMIT PADA JARINGAN 3G TERHADAP KUALITAS EC/NO DAN RECEIVED SIGNAL CODE POWER DALAM HUBUNGAN INTENSITAS TRAFIK ., Teguh Handarbeni
Jurnal Teknik Elektro Universitas Tanjungpura Vol 1, No 1 (2014): Jurnal Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

In WCDMA cellular systems, the transmit power setting will affect the capacity and coverage of the area. The use of a small transmit power with a large amount of user can cause excess load on the network itself. so it is necessary to increase the transmit of power parameters. This study analyzed the ratio of the transmit power on the quality of Ec / No and RSCP in traffic intensity. results in Jalan Imam Bonjol (site 140 744) pontianak. This study shows that for best results of RSCP plot using 448 dBm power sector with a range of 2 -74 dBm to 0 dBm, the worst results using 430 dBm power sector with a range of -83 dBm 3 to -78 dBm and to plot the results of Ec / No , the best results use a transmit power range of 430 dBm to -4 dBm to 0 dBm, the worst results using 448 dBm transmit power with a range of -9 dBm to -12 dBm. For the calculation of the intensity of traffic, the highest value were obtained with 430 dBm transmit power at sector 3 which is got 1.6 at the result. The lowest traffic intensity obtained from 448 dBm transmit power in sector 2 which is got 0.05. From these results, we can take some good summaries that the transmit power changes have a major impact on the Received Signal Code Power (RSCP) and does not affect the quality of chips per Noise Energy as Ec / No is strongly influenced by the number of users. Related with the traffic intensity, changing the transmit power did not affect voice traffic intensity values ?significantly, since voice system redirected over 2G networks in principal of the system. Kata kunci - Power transmit, Recived Signal Code Power (RSCP), Energy Chip per Noise (Ec/No), Intensitas Trafik
ANALISIS KUALITAS JARINGAN USEETV CABLE MENGGUNAKAN KABEL TEMBAGA PADA PT TELKOM PONTIANAK Novi Aryani Fitri, Novi Aryani Fitri
Jurnal Teknik Elektro Universitas Tanjungpura Vol 2, No 1 (2014): Jurnal Teknik Elektro UNTAN
Publisher : Faculty of Engineering, Universitas Tanjungpura

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Teknologi ADSL merupakan teknologi akses yang memungkinkan terjadinya komunikasi data, voice dan video (Triple Play) menjadi satu secara bersamaan pada media jaringan akses tembaga. Layanan UseeTV Cable merupakan layanan televisi berbayar berbasis internet yang dimiliki oleh PT Telekomunikasi Indonesia Tbk. Parameter yang mempengaruhi kualitas jaringan diantaranya: Line Rate, Signal to Noise Ratio (SNR),Attenuation (redaman) dan Attainable Rate. Dalam penelitian ini dilakukan analisis kualitas jaringan dengan menggunakan software EMBASSY, yang merupakan aplikasi web internal PT. Telkom, Tbk. Dari hasil pengukuran yang telah dilakukan terhadap 5 pelanggan UseeTV Cable diperoleh nilai Line Rate Downstream tertinggi adalah 3680 Kbps dan Line Rate Downstream terendah adalah 3582 Kbps. Nilai tertinggi untuk  SNR adalah 30.3 dB yang menyatakan bahwa nilai tersebut bagus karena sudah memenuhi standar yang sudah ditentukan ≥25 dB dan nilai SNR terendah adalah 6 dB yang menyatakan bahwa nilai tersebut jelek karena dibawah dari nilai standar yang sudah ditentukan ≤13 dB. Nilai terendah untuk Attenuation Downstream adalah 28 dB yang menunjukkan hasil bagus pada jalur trasmisinya dan nilai tertinggi untuk Attenuation Downstream adalah 45.6 dB yang menunjukkan hasil bagus pada jalur trasmisinya karena nilai redaman jaringan yang diukur kecil dengan nilai tidak diatas 50 dB yang merupakan nilai buruk untuk kualitas Attenuation. Nilai tertinggi untuk Attainable RateDownstream adalah 14360 Kbps dan nilai terendah Attainable Rate Downstream adalah 3175 Kbps. Sehingga dari pengukuran ke-5 pelanggan ini menunjukkan bahwa kapasitas bandwidth (Attainable rate) maksimum yang dapat ditrasmisikan melalui jaringan sangat mensuport untuk layanan UseeTV Cable. Kata kunci : ADSL, UseeTV Cable, software EMBASSY dan kualitas jaringan