cover
Contact Name
Machrus Ali
Contact Email
fortei.vii@gmail.com
Phone
+6281330002213
Journal Mail Official
fortei.vii@gmail.com
Editorial Address
Departemen Teknik Elektro, FTE-ITS, Gedung B-C lantai 2, Kampus ITS, Surabaya, Surabaya, Provinsi Jawa Timur, 60111
Location
Kota malang,
Jawa timur
INDONESIA
Jurnal Fortech
ISSN : 27212858     EISSN : 27209253     DOI : https://doi.org/10.56795/fortech
Bidang kajian Jurnal FORTECH meliputi bidang; Teknik tenaga listrik, Teknik elektromagnetik, Teknik telekomunikasi, Teknik komputer, Teknik elektronika, Teknik rekayasa sistem, Teknik kendali, Biomedik, dan bidang elektro lainnya
Articles 124 Documents
Pengendalian Level Air Modern dengan Algoritma Semut ACO-PID untuk Kontrol Presisi Asnun Parwanti; Machrus Ali; Izzatul Umami; Rukslin
Jurnal FORTECH Vol. 4 No. 2 (2023): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v4i2.4207

Abstract

Fluid flow measurement and control are fundamental requirements in various industrial processes, particularly for maintaining stable water volumes in storage tanks. Water level control systems typically employ Proportional–Integral–Derivative (PID) controllers. A primary challenge with PID controllers lies in determining the Kp, Ki, and Kd constants; manual tuning or trial-and-error approaches often result in slow, oscillatory, and suboptimal responses. This study proposes automated PID parameter tuning using Ant Colony Optimization (ACO), an artificial intelligence method that mimics the behavior of ant colonies in finding the shortest path via pheromone trails. The tuning objective function utilizes the Integral of Time-multiplied Absolute Error (ITAE) to minimize overshoot and settling time. The performance of the proposed PID-ACO method was compared against four scenarios—an uncontrolled system, conventional PID, Fuzzy Logic Controller (FLC), and Fuzzy-PID—using MATLAB/Simulink simulations. Simulation results demonstrate that PID-ACO delivers the best performance, achieving the lowest water level overshoot (0.5039 pu) and undershoot (0.5187 pu). Regarding output flow, the method achieved the lowest overshoot (0.0016 pu) and undershoot (0.0009 pu), as well as the fastest settling time. Thus, ACO-based PID tuning is proven to significantly enhance the stability and accuracy of water level control compared to the benchmark methods.
Performasi Metode Kecerdasan Buatan (FA, PSO, ACO, GWO, dan OPA) Untuk Penalaan PID Pada Pengendalian Level Air Izzatul Umami; Asnun Parwanti; Machrus Ali; Dafit Soni Setiawan
Jurnal FORTECH Vol. 5 No. 2 (2024): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v5i2.5208

Abstract

Water level control is a critical problem in various industrial processes, such as water treatment, power generation, chemical industry, and irrigation. Although proportional–integral–derivative (PID) controllers are widely used due to their simple structure and ease of implementation, determining the parameters Kp, Ki, and Kd remains challenging for systems with nonlinear dynamics and actuator limitations. This study presents a comparative evaluation of five population-based metaheuristic algorithms—Firefly Algorithm (FA), Particle Swarm Optimization (PSO), Ant Colony Optimization (ACO), Grey Wolf Optimizer (GWO), and Orca Predation Algorithm (OPA)—for automatic tuning of PID parameters in a second-order water tank model with actuator saturation of ±5 pu. The objective function employed is the Integral of Time-multiplied Absolute Error (ITAE) with an overshoot penalty. The comparison was conducted under identical conditions, including population size, number of iterations, parameter search ranges, initial conditions, and objective function. Simulation results demonstrate that ACO-PID achieves the lowest ITAE value of 0.2352 and the fastest settling time of 1.32 s. FA-PID, GWO-PID, and OPA-PID yield closely comparable performance, whereas PSO-PID produces zero overshoot at the expense of the highest ITAE value of 0.2668 and the longest settling time of 1.66 s. The execution times of all five algorithms are relatively similar, ranging from 4.84 to 5.16 s. These findings indicate that ACO is the most suitable method for the plant configuration and objective function examined in this study; however, the performance differences among ACO, FA, GWO, and OPA are relatively small and cannot be considered statistically significant without multi-run testing and statistical analysis.
Sistem Kendali Drone Bawah Air Berbasis Arduino Uno Rian Putra Eka Setiawan; Suko Wiyanto; Fajar Kholid
Jurnal FORTECH Vol. 7 No. 1 (2026): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v7i1.7108

Abstract

Indonesia is one of the largest maritime countries in the world with 80% of its territory in the form of oceans. which can cause difficulty in reconnaissance of security in the territory of the Republic of Indonesia, especially in the maritime sector. Therefore, it is very necessary to design a mini submarine concept that is responsive as an alusista for reconnaissance and the Indonesian maritime area. namely by using an underwater drone design with the Arduino Uno system that has been made this time. In this study, designing a robot motion control system with the type of control that has been implemented using a remote control system that utilizes remote control as a wireless communication tool, joystick as data generator and processed using Arduino Uno. To be able to receive the data that has been sent, an IA6B wireless receiver is designed and then the data is used as an instruction to control the robot's motion. From the results of the study, it was found that the flysky remote control can be used to control the robot's motion with the results of the maximum control distance data being 50 meters, this proves that the control system using the flysky wireless remote control works well and can control the movement according to the instructions given via the joystick.
Exploration of Control Systems for Autonomous City Combat Robots Based on the Internet of Things (IoT) from a Military Perspective Jeffri Kurniawan; Muhammad Syafaat; Fajar Kholid
Jurnal FORTECH Vol. 7 No. 1 (2026): Jurnal FORTECH
Publisher : FORTEI (Forum Pendidikan Tinggi Teknik Elektro Indonesia)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.56795/fortech.v7i1.7107

Abstract

TNI soldiers are currently facing an interesting change in tasks with the introduction of robot designs for carrying out reconnaissance. This robot is designed to play a key role in war operations, especially in enemy reconnaissance. Conventional surveillance methods often carry high risks, including the potential loss of life. This research is analytical observational research with the aim of analyzing 3 types of robot control system modes, namely the distance through various trajectories that have been determined using trajectory tracking, the application value of the IMU sensor with an autonomous robot in acceleration movement, as well as the error value that occurs in the control system. PID of the x and y axes. In an effort to increase efficiency and safety, this robot is equipped with rotary encoder sensors to record the X and Y values at each DC motor rotation, monitoring the robot's movement path. In addition, this robot is equipped with various sensors, including ultrasonic sensors, the Gyro MPU 6050, and artificial intelligence to avoid collisions with other objects. IMU sensors are used to detect and understand robot movements through a combination of accelerometers and gyroscopes. The PID control method is applied to regulate the rotation of a DC motor with reverse kinematics. In testing, the robot was tested on various paths, such as a square, an isosceles triangle, and a circle with obstacles. The test results show that the RPM on the tachometer, compared to the rotary encoder, has an error rate of around 1.2. The mobile robot will carry out reconnaissance according to a predetermined path. This omniwheel can move and rotate in all directions with a flat trajectory, providing acceleration for the robot to move efficiently with a success percentage in testing the robot's movement of 89.31%. From the experimental results, an average error rate of 11% on a square track, 15% on a circle track, and 4.17% on a triangle track was obtained. The maximum stability of the rotational speed of the motor on the Omni robot is found on the triangular path.

Page 13 of 13 | Total Record : 124