cover
Contact Name
Afri Yudamson
Contact Email
afri.yudamson@eng.unila.ac.id
Phone
+6285709220573
Journal Mail Official
afri.yudamson@eng.unila.ac.id
Editorial Address
Jurusan Teknik Elektro FT Universitas Lampung Gedung-H Fakultas Teknik Unila Jl. Prof. Soemantri Brojonegoro No. 1 Bandar Lampung 35145 Telp: +62882-6703-2879, +62853-5788-8738 WA: +62882-6703-2879 Website: http://electrician.unila.ac.id
Location
Kota bandar lampung,
Lampung
INDONESIA
Electrician : Jurnal Rekayasa dan Teknologi Elektro
Published by Universitas Lampung
ISSN : -     EISSN : 25493442     DOI : https://doi.org/10.23960/elc
Core Subject : Engineering,
Focus and Scope Publication of scientific research results in the field of electrical engineering which covers: ~ Power system analysis ~ Electrical energy conversion ~ High voltage technology ~ Electronics ~ Control system ~ Telecommunication system ~ Computer and interfacing ~ Information engineering.
Articles 621 Documents
A MODEL SISTEM DETEKSI KONDISI ABNORMAL PADA KONSUMSI ENERGI LISTRIK DI JARINGAN DISTRIBUSI 1 PHASE MENGGUNAKAN ANFIS Jimmy Lukita
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2921

Abstract

Adaptive Neuro- Duzzy Inference System (ANFIS) terbukti mampu mengklasifikasikan pola konsumsi energi listrik degan akurasi rata-rata 66,64% dan tingkat kesalahan 33,36%. Variasi presisi terlihat pada setiap label, dimana label 1 dan 4 memiliki nilai rendah, sementara label 2,3,dan 5 menunjukkan performa lebih baik. Presisi tertinggi mencapai 94,28% pada lable 5 menandakan kemampuan ANFIS dalam mengenali pola konsumsi tertentu dengan lebih tepat. Keandalan model diperkuat melalui evaluasi menggunakan RMSE,MAE dan MBE tersebut menunjukkan kecenderungan underestimasi dalam skala yang sangat kecil. Selain itu, penerapan normalisasi data memberikan dampak positif terhadap performa model, dengan perbedaan signifikan dibandingkan data mentah, yaitu seilis RMSE sebesar 0,5022 dan MAE sebesar 0,3595. Temuan ini menekankan bahwa pemilihian fungsi keanggotaan yang terpat serta normalisasi data berperan penting dalam meningkatkan efektivitas anfis untuk deteksi anomali konsumsi listrik.
Analisis Performa Daya Baterai untuk Sistem Kendali Kapal Remote Control Berbasis ESP8266 ESP-12F fatkhan kausar
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2944

Abstract

Sistem kendali nirkabel pada kapal remote control (RC) memerlukan sumber daya baterai yang efisien dan andal. Penelitian ini menganalisis performa daya baterai pada kapal RC yang dikendalikan menggunakan modul ESP8266. Tujuan penelitian ini adalah untuk mengukur ketahanan baterai dalam berbagai kondisi operasional. Prototipe kapal RC ditenagai oleh empat baterai lithium-ion 18650 dengan kapasitas total 4000 mAh. Pengujian dilakukan dalam empat skenario yaitu standby, hanya motor servo aktif, hanya motor brushless aktif, dan kondisi operasional penuh. Hasil pengujian menunjukkan bahwa dalam kondisi standby, konsumsi arus sangat rendah (50,56 mA), memungkinkan sistem bertahan hingga 79 jam. Sementara itu, dalam kondisi operasional penuh (motor dan servo aktif), arus meningkat menjadi 2000mA, dengan perkiraan waktu operasional sekitar 2 jam. Hasil penelitian menunjukkan bahwa sistem memiliki efisiensi daya yang baik dan baterai yang terpasang mampu mendukung pengoperasian secara efektif.
Analisa dan Optimasi Koordinasi Over Current Relay (OCR) Dan Ground Fault Relay (GFR) Dengan Menggunakan Metode Particle Swarm Optimization (PSO) Muhammad Riehan Arraief; Lukmanul Hakim; Zulmiftahul Huda; Osea Zebua
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2954

Abstract

Sistem proteksi pada jaringan tenaga listrik dituntut untuk bekerja cepat, tepat, dan selektif demi menjaga keandalan serta keamanan operasi. Penelitian ini bertujuan untuk menganalisis dan mengoptimalkan koordinasi Over Current Relay (OCR) dan Ground Fault Relay (GFR) menggunakan metode Particle Swarm Optimization (PSO). Parameter yang dioptimalkan meliputi Time Dial Setting (TDS), arus pick-up (??), dan waktu operasi. Hasil penelitian menunjukkan bahwa metode PSO menghasilkan setting baru yang lebih selektif dibanding kondisi eksisting. Setting akhir yang diperoleh adalah sebagai berikut: OCR penyulang dengan ?? = 360 A, TDS = 0.15 s; OCR 20 kV dengan ?? = 2000 A, TDS = 0.27 s; OCR 150 kV dengan ?? = 270 A, TDS = 0.38 s. Sementara itu, GFR penyulang memiliki ?? = 30 A dengan waktu operasi 0.125 s, GFR 20 kV dengan ?? = 100 A dan waktu operasi 0.23 s, serta GFR 150 kV dengan ?? = 90 A dan waktu operasi 0.62 s. Urutan kerja proteksi menjadi lebih optimal, yaitu relay penyulang bekerja paling cepat, diikuti relay 20 kV, dan terakhir relay 150 kV, sesuai standar IEC 60255. Dengan demikian, penerapan metode PSO mampu mengoptimasi koordinasi sistem proteksi serta meminimalisir pemutusan area gangguan yang lebih luas.
Desain dan Implementasi Kapasitor Bank Otomatis Berbasis Mikrokontroler untuk Koreksi Faktor Daya Ibrohim; Subuh Isnur Haryudo; Endryansyah; Hafidz Nindhom Zen
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2960

Abstract

Electrical energy efficiency in household installations is a critical issue, primarily due to the low power factor (cos φ) caused by the dominant use of inductive appliances such as air conditioners, refrigerators, and water pumps. This condition results in significant energy losses and increases the load on residential electrical networks. This study designs an automatic capacitor bank system based on an Arduino Nano microcontroller to dynamically correct the power factor. The system is equipped with a PZEM-004T sensor to monitor voltage, current, and power factor in real time. Based on the measured data, the microcontroller automatically controls relay modules to connect capacitors with the most suitable capacitance according to load variations. The main innovation of this system lies in its adaptive automation mechanism, which enables a rapid and efficient response to electrical load fluctuations. Implementation results show that the system can improve the power factor to nearly 1.0, effectively reducing reactive energy consumption, lowering electricity costs, and enhancing the overall efficiency and stability of household electrical systems.
Analysis of Matrix Converter as Solid State Transformer (SST) in Battery Charging Using Fuzzy Logic Control Lungguk Sibuea
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2964

Abstract

Technological advancements in the digital era have made electrical energy needs vital in the industrial world. The reliability of electricity supply certainly has serious challenges related to transmission system blackouts due to the failure of blackstart at the plant because the battery supply is not functioning optimally. To anticipate this failure, Matrix Converter (MC) modeling is carried out as a Solid State Transformer (SST) to replace conventional transformers to maintain voltage stability and change the voltage according to the needs for battery supply. The SVPWM methodology uses 9 bidirectional switches in the MC to modulate pulse width by comparing the duty cycle against high-frequency waves. This comparison can determine when each switch in the converter should be open or closed in each switching cycle. To control stable voltage and efficient current in the battery charging process, Fuzzy Logic control (FLC) is used. With a Rectifier as the converter (AC-DC), a stable voltage of 127.6 volts DC is obtained, so the battery charging process can work optimally and stably.
Smart Lab Energy – For Real-Time Electricity Consumption Monitoring In The Electronics Engineering Technology Laboratory, Polytechnic State Of Lampung Tomy Pratama Zuhelmi; Novia Utami Putri; Ayu Sintianingrum; Syaiful Mansur; Ernando Rizki; Amanda Putri Denizka; Altino Adni Riyadi
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2970

Abstract

This study aims to design and implement an Internet of Things (IoT)-based electrical energy monitoring system capable of displaying real-time data in a vocational education laboratory environment. The developed system utilises an ESP32 microcontroller and a PZEM-004T sensor to accurately measure voltage, current, power, and energy parameters. The measurement data are transmitted to a cloud server and visualised through a digital dashboard, allowing users to monitor and analyse energy usage easily. The test results show that the system performs well and produces consistent data compared to manual measurements using a digital clamp meter. The implementation of this system has the potential to improve energy efficiency, reduce power waste, and support the application of a green campus concept in higher education institutions. Moreover, this system can be used as a project-based learning medium to enhance students’ competencies in embedded systems, sensors, and IoT-based automation.
Perancangan Sistem Kendali Lift 2 Kanal 5 Lantai Berbasis Gerbang Logika Dasar Erik Agustian Yulanda
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2972

Abstract

Lift merupakan sarana transportasi vertikal penting pada bangunan bertingkat yang membutuhkan sistem kendali yang efisien dan reliabel. Penelitian bertujuan untuk merancang prototipe sistem kendali lift lima lantai 2 kanal berbasis gerbang logika dasar tanpa mikrokontroler. Sistem mengandalkan logika kombinasional dan sekuensial untuk mengatur arah gerak, kecepatan motor, serta penghentian pada setiap lantai melalui limit switch. Validasi awal dilakukan melalui simulasi pada software Proteus, kemudian direalisasikan pada prototipe fisik menggunakan Motor DC N20. Hasil pengujian menunjukkan waktu respons rata-rata 315 ns saat lift turun dan 640 ns saat bergerak naik. Kecepatan operasi berkisar antara 20 hingga 24 FPM. Hasil pengujian membuktikan bahwa pemanfaatan gerbang logika dasar dapat menghasilkan sistem kendali lift yang efisien dan responsif.
Implementasi Multiplexer 74HC4051 untuk Optimasi Jumlah Sensor Garis pada Robot Line Follower Agusma Wajiansyah
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.2999

Abstract

Robot line follower membutuhkan sejumlah sensor reflektif untuk mendeteksi posisi garis secara akurat. Namun, keterbatasan jumlah pin ADC pada mikrokontroler sering menjadi hambatan dalam penambahan sensor. Penelitian ini membahas implementasi multiplexer 74HC4051 sebagai solusi untuk memperluas jumlah kanal sensor tanpa menambah kebutuhan pin ADC. Delapan sensor reflektif dihubungkan melalui 74HC4051 dan diuji pada dua kondisi permukaan, yaitu putih dan hitam. Hasil pengujian menunjukkan bahwa nilai ADC pada permukaan putih berada pada rentang 966–978 dengan rata-rata 972, sedangkan permukaan hitam menghasilkan nilai pada rentang 127–387 dengan rata-rata 239. Selisih rata-rata sebesar 733 poin ADC menunjukkan tingkat kontras yang sangat baik untuk proses deteksi garis. Waktu pembacaan ADC menggunakan multiplexer berada pada kisaran 113 µs, hanya sedikit lebih tinggi dibanding pembacaan tanpa multiplexer, sehingga tidak mengganggu performa waktu nyata robot. Hasil ini membuktikan bahwa implementasi multiplexer 74HC4051 efektif dalam mengoptimalkan jumlah sensor garis sekaligus mempertahankan kualitas dan kecepatan pembacaan. Pendekatan ini memungkinkan desain robot line follower yang lebih presisi, responsif, dan fleksibel dalam konfigurasi jumlah sensor
Adaptive Path Planning Using Depth-First Search in Environments with Dynamic Obstacle Ni Putu Devira Ayu Martini; Muchamad Oktaviandri; Elvi Armadani
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.3002

Abstract

Depth-First Search (DFS) is one of the classical algorithms used for robotic path planning due to its simplicity and deterministic exploration strategy. However, its performance can degrade significantly in environments where obstacles move or appear unexpectedly. This study analyzes the behavior of the DFS algorithm under both static and dynamic obstacle conditions using a grid-based simulation. Three primary performance indicators were evaluated: total path length, turning complexity, and overall path efficiency. In static environments, where all obstacle positions were known beforehand, DFS demonstrated stable and efficient navigation, achieving approximately 117% shorter paths, 42% higher efficiency, and 133% fewer turning maneuvers compared to scenarios with dynamic obstacles. When unexpected obstacles were introduced, the robot frequently performed backtracking and route replanning, which increased the total travel distance and the number of directional changes, ultimately lowering navigation efficiency. Despite these challenges, the DFS algorithm was still capable of reaching the goal after multiple replanning steps. These findings highlight both the robustness and limitations of DFS and suggest that integrating adaptive sensing or hybrid algorithms could improve performance in unpredictable, dynamic environments.
Analisis Pengaruh Perawatan Dua Tahunan Terhadap Keandalan Dan Kinerja Circuit Breaker 150 kV Di Gardu Induk Anyer Bay Menes 1 Repaldi Repaldi; Desmira
Electrician : Jurnal Rekayasa dan Teknologi Elektro Vol. 20 No. 1 (2026)
Publisher : Department of Electrical Engineering, Faculty of Engineering, Universitas Lampung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.23960/elc.v20n1.3010

Abstract

Penelitian ini bertujuan menganalisis pengaruh pemeliharaan dua tahunan terhadap keandalan dan kinerja Circuit Breaker 150 kV di Gardu Induk Anyer Bay Menes 1. Pemeliharaan berkala diperlukan untuk menjaga keandalan sistem tenaga listrik dan meminimalkan risiko gangguan peralatan tegangan tinggi. Metode yang digunakan adalah deskriptif kuantitatif berdasarkan analisis data pengujian sebelum dan sesudah pemeliharaan pada periode 2020–2022. Parameter yang dianalisis meliputi tahanan isolasi, tahanan kontak, tahanan pentanahan, keserempakan, dan waktu kerja kontak. Hasil menunjukkan peningkatan performa setelah pemeliharaan, ditunjukkan oleh penurunan selisih waktu keserempakan dari 0,7 ms menjadi 0,4 ms pada proses buka dan dari 3,6 ms menjadi 2,3 ms pada proses tutup. Nilai tahanan kontak tetap berada di bawah batas IEC 60694 (≤ 50 µΩ), dan tahanan pentanahan meningkat dari 0,4 Ω menjadi 0,3 Ω. Meskipun beberapa nilai tahanan isolasi menurun, nilainya masih jauh di atas batas standar VDE 228/4. Temuan ini membuktikan bahwa pemeliharaan dua tahunan efektif meningkatkan keandalan operasi Circuit Breaker. Rekomendasi penelitian ke depan adalah pemeliharaan berbasis trending data dan condition monitoring.