cover
Contact Name
Tri Rahayu
Contact Email
indexsasi@apji.org
Phone
+6285885852706
Journal Mail Official
indexsasi@apji.org
Editorial Address
Jl. Waru no. 15 Rawamangun Jakarta Timur, Email: mauludiali94@gmail.com (Hp 082135416714), (Hp. 08138408664)
Location
Kota adm. jakarta timur,
Dki jakarta
INDONESIA
JURNAL ILMIAH TEKNIK INDUSTRI DAN INOVASI (JISI)
Published by CV Alim Publishing
ISSN : 2985315X     EISSN : 29645964     DOI : ttps://doi.org/10.59024/jisi.v1i3.287
JURNAL ILMIAH TEKNIK INDUSTRI DAN INOVASI (JISI) memuat hasil-hasil penelitian dalam bidang Teknik dan Manajemen Industri, yang belum pernah dipublikasikan atau sedang dikirim pada jurnal lain. lingkup jurnal meliputi : Desain dan Pengukuran Pekerjaan Riset dan Analisis Operasi Analisis Ekonomi Teknik Rekayasa Fasilitas dan Manajemen Energi Teknik Kualitas dan Reliabilitas Faktor Ergonomi dan Manusia Teknik dan Manajemen Operasi Manajemen Suplai Chain Manajemen Teknik Safety Teknik Informasi Desain dan Pengembangan Produk Desain dan Rekayasa Sistem . Jurnal ini terbit 1 tahun 4 kali (Januari, April, Juli dan Oktober)
Articles 93 Documents
Analisis Risiko Keselamatan Kerja pada Aktivitas Pengelasan Menggunakan Metode HIRARC dan Fault Tree Analysis di PT XYZ Suparjo Suparjo; Wanda Oktiva Andini
JURNAL ILMIAH TEKNIK INDUSTRI DAN INOVASI Vol. 4 No. 4 (2026): Oktober : Jurnal Ilmiah Teknik Industri dan Inovasi
Publisher : CV. ALIM'SPUBLISHING

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59024/jisi.v4i4.2641

Abstract

This study analyzes occupational safety and health risks in the welding process at PT. XYZ using the Hazard Identification, Risk Assessment, and Risk Control (HIRARC) and Fault Tree Analysis (FTA) methods. Welding activities involve various hazards, including sparks, hot metal fragments, welding fumes, ultraviolet and infrared radiation, high temperatures, and electrical currents. The HIRARC method was applied to identify hazards, assess risk levels based on the AS/NZS 4360:2004 standard, and determine appropriate control measures using the Hierarchy of Control. The results identified ten potential hazards across four groups of work activities, consisting of one high-risk hazard, two moderate-to-high-risk hazards, five moderate-risk hazards, and two low-to-moderate-risk hazards. The highest risk was exposure to hot metal fragments (welding slag), with a risk score of 20 (L = 5; S = 4). Furthermore, Fault Tree Analysis was conducted to determine the root causes of the highest-risk hazard. The analysis revealed that the incident was mainly caused by three factors: failure to use personal protective equipment (PPE), unsafe working conditions, and human error. Based on these findings, risk control recommendations were developed using the 5W+1H approach, including strengthening PPE compliance, installing welding curtains, implementing a permit-to-work system, and conducting regular occupational safety and health training to reduce workplace accidents during welding operations at PT. XYZ.
Analisis Efisiensi Biaya Operasional melalui Optimasi Jadwal Operasi Pompa Penyalur di Fuel Terminal Lomanis Muhammad Ichsan Anshori; Agus Adhi Nugroho
JURNAL ILMIAH TEKNIK INDUSTRI DAN INOVASI Vol. 4 No. 4 (2026): Oktober : Jurnal Ilmiah Teknik Industri dan Inovasi
Publisher : CV. ALIM'SPUBLISHING

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59024/jisi.v4i4.2683

Abstract

Lomanis Fuel Terminal distributes fuel through four pipeline routes using electric transfer pumps, with monthly electricity bills exceeding IDR 1 billion. This study analyzes pump operations, energy consumption, Peak Load Time (WBP) and Off-Peak Load Time (LWBP) costs, and potential savings from rescheduling without changing distributed volume. A quantitative descriptive method used 2025 PLN billing and Batch Program data with daily-resolution idle-slot simulation. Annual consumption totaled 14,781,944 kWh, costing IDR 16,283,735,609; pumps consumed 99.46%. WBP represented 12.7% of energy but 17.9% of costs, with tariffs approximately 50% higher than LWBP. Simulation indicated that 1,408.0 of 5,379.5 WBP operating hours (26.2%) could shift to LWBP while maintaining total operating hours and distributing 7,641,963 KL, potentially saving IDR 254,634,421 annually (1.56%) without capital expenditure. Separately, actual before–after bills showed reductions of 34.69% in WBP consumption and 11.77% in electricity costs, while cost per litre decreased from IDR 2.46 to IDR 2.08 despite a 4.91% volume increase. These changes cannot be attributed entirely to rescheduling because total energy consumption and monthly conditions also varied. CY-2, accounting for an estimated 43.12% of pump energy, is recommended as a conditional implementation priority, subject to receiving-terminal stock validation.
Perancangan Sistem Peringatan Dini Bahaya Kebakaran Berbasis Infrared Fire and Gas Detector dengan Voting Logic 2oo3 dan Verifikasi Safety Integrity Level pada Terminal BBM PT XYZ Muhammad Fikri Baharuddin; Eka Nuryanto Budisusila
JURNAL ILMIAH TEKNIK INDUSTRI DAN INOVASI Vol. 4 No. 4 (2026): Oktober : Jurnal Ilmiah Teknik Industri dan Inovasi
Publisher : CV. ALIM'SPUBLISHING

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.59024/jisi.v4i4.2684

Abstract

Fuel terminals store large volumes of volatile hydrocarbons, and a leak can form a flammable vapor cloud that may escalate into a fire or explosion. A root cause analysis at the PT XYZ fuel terminal in Semarang found no fixed vapor cloud detection. This study designs an infrared fire and gas detection-based early warning system that detects leaks, alerts operators, and triggers automatic protection, and verifies its reliability against IEC 61508/61511. Methods include a 5×5 risk matrix, orifice leak rate calculation, Gaussian plume dispersion with 2020–2024 BMKG wind data, 2oo3 voting and electrical design, Layer of Protection Analysis (LOPA), and PFDavg calculation with OREDA data. Leak rates through a 10 mm hole range from 0.32 to 1.45 kg/s, giving conservative 20% LFL hazard radii of 30–66 m. The design uses 22 infrared detectors in five zones with 2oo3 voting on a 1oo2D Safety PLC, lowering the false alarm probability to 0.12% while keeping the sensor PFD at 0.73%. The total PFDavg is 7.53×10−3 (SIL 2) with a risk reduction factor of 133, making it a suitable protection layer for the terminal. The motor operated valve contributes 87.2% of the total PFDavg, making final element redundancy the most effective improvement.

Page 10 of 10 | Total Record : 93