cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota surabaya,
Jawa timur
INDONESIA
Jurnal Teknik Sipil
ISSN : -     EISSN : -     DOI : -
Core Subject : Engineering,
Arjuna Subject : -
Articles 185 Documents
DAMPAK KEBERADAAN LIPPO PLAZA TERHADAP KINERJA LALU LINTAS DI RUAS JALAN VETERAN KOTA KUPANG Bolla, Margareth E.; Udiana, I Made; Utama, Andi A.A.W.
Jurnal Teknik Sipil Vol 6, No 1 (2017)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (202.931 KB)

Abstract

This research aimed at measuring level of performance in the form of service capacity at Veteran St., as it was affected by the existence of Lipo Plaza. The affect of the business center on service capacity of some sections of roads would be expressed in the comparisons of traffic volume, traffic capacity and degree of saturation (DS) before its existence, to the same after it had existed. Result of analysis in this research showed that there was a change in traffic volume, either increasing or decreasing. Increase of traffic volume occurred at segment of Veteran St., Patung Kirab area, Nostalgia Park area, Ina Bo’I, W.R. Monginsidi St., and Perintis Kemerdekaan St., each in value of 81.5 pmu/h, 35.97 pmu/h, 17.41 pmu/h, 8.83 pmu/h and 38.94 pmu/h respectively; whereas decrease of the same occurred at road segment to the back of Ruko Oebobo, in the value of 1.37 pmu/h. Service level of Veteran St. was proved to be still adequate despite the dercrease of DS at Veteran St., Patung Kirab area, Nostalgia Park area, Ina Boi, W.R. Monginsidi St, and Perintis Kemerdekaan St., each in the value of 4.05%, 2.07%, 0.75% 0.34% and 2.86 respectively. There was still location with decreasing DS that is the segment of road to the back of Ruko Oebobo, namely 0.13%. Observation also showed that there exists potency for traffic jam, therefore measures for prevention was recommended, such as installing warning traffic-light at intersection of Veteran St., Nostalia Park and Ruko Oebobo, and temporary road separator at Veteran St. These could as well prevent traffic crash at conflict points.
PERUBAHAN KONDISI TATAGUNA LAHAN TERHADAP VOLUME SEDIMENTASI PADA EMBUNG BIMOKU DI LASIANA KOTA KUPANG Bunganaen, Wilhelmus
Jurnal Teknik Sipil Vol 1, No 2 (2011)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (91.349 KB)

Abstract

ABSTRAKTujuan Penelitian ini untuk menganalisisi volume sedimentasi yang terjadipada Embung Bimoku di Lasiana Kota Kupang pada kondisi tataguna lahan baikdan kondisi tataguna lahan buruk. Hasil penelitian menunjukan bahwa volumesedimentasi pada kondisi tataguna lahan pada kala ulang 12 tahun untuk kondisitataguna lahan baik 206,91 m3, dan kondisi tataguna lahan buruk 304,16 m3.Apabila kedua volume tersebut jika dibandingkan terhadap batas ruangsedimentasi embung 288 m3, maka untuk kondisi tataguna lahan baik secarateoritis volumenya belum melampaui, dan kondisi tataguna lahan buruk secarateoritis telah melampaui batas ruang sedimentasi embung.
PENGARUH VARIASI PERHITUNGAN TEGANGAN DAN REGANGAN KOLOM BETON BERTULANG TERHADAP DAKTILITAS PENAMPANG TAKTERKEKANG Simatupang, Partogi H.; Siallagan, Gisella D.; Pah, Jusuf J. S.
Jurnal Teknik Sipil Vol 7, No 1 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (262.065 KB)

Abstract

Salah satu parameter penting dalam  perencanaan suatu kolom adalah daktilitas.  Nilai daktilitas suatu kolom dapat ditentukan dari kurva hubungan antara momen dan kurvatur. Nilai momen dan kurvatur didapat dari perhitungan tegangan dan regangan beton.Tujuan penelitian ini adalah untuk mengetahui pengaruh variasi tegangan dan regangan kolom beton bertulang terhadap daktilitas penampang tak terkekang. Dalam analisis ini hubungan tegangan dan regangan menggunakan 4 metode yaitu Kent and Park, Popovics, Thorenfeldt dan Hognestad yang kemudian dilakukan analisis momen dan kurvatur secara manual dari hubungan tegangan dan regangan. Selain menghitung secara manual juga digunakan program bantuResponse 2000. Output Response 2000 digunakan sebagai pembanding dengan cara perhitungan manual. Hasil analisis secara manual maupun menggunakan Response 2000 menunjukkan luas tulangan longitudinal dan mutu tulangan longitudinalyang meningkat dapat menurunkan nilai daktilitas kolom sedangkan mutu beton yang meningkat maka daktilitas juga meningkat. Selain itu, konfigurasi tulangan longitudinal juga dapat mempengaruhi nilai daktilitas suatu kolom dengan nilai daktilitas paling kecil terdapat pada sampel UC3-01.One of the important parameter in a column planning is ductility. Ductility of a column can determined from relation curve between moment and curvature.Moment and curvature value is obtained from the calculation of concrete stress and strain.This research aims is to know the effect of stress and strain variation of reinforced concrete column on unconfined section ductility.In this research, stress and strain relation use 4 methods such as Kent and Park, Popovics, Thorenfeldt and Hognestad and then moment-curvature analysis is done manually by Ms.Excel 2013 from stress-strain relation. Besides counting manually also used the Response 2000 program. Output of Response 2000 is used as a comparison by manual calculation. The results of manual analysis or using Response 2000 indicates that an increase in the area of longitudinal reinforcement and the steel yield strength can decreases the ductility while an increase in the concrete strength increases the ductility. In addition, the configuration of longitudinal reinforcement also affects the ductility of a column with the smallest ductility value in the UC3-01.
PENGGUNAAN METODE KAGAN UNTUK ANALISIS KERAPATAN JARINGAN STASIUN HUJAN PADA WILAYAH SUNGAI (WS) WAE-JAMAL DI PULAU FLORES Krisnayanti, Denik Sri; Bunganaen, Wilhelmus; Kedoh, Jacob
Jurnal Teknik Sipil Vol 1, No 3 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1094.784 KB)

Abstract

ABSTRAKData stasiun hujan sangat penting dalam analisis hidrologi suatu Wilayah Sungai (WS). Tujuan setiappengukuran curah hujan suatu lokasi adalah untuk memperoleh data yang benar-benar mewakili lokasi tersebut.Dalam melakukan pengukuran curah hujan terdapat beberapa pertimbangan antara lain adalah bagaimanamenentukan lokasi jaringan kerja alat penakar tersebut agar dapat mewakili daerah yang dikehendaki gunamenghitung curah hujan suatu area.Untuk mengetahui ketelitian perkiraan hujan pada WS Wae-Jamal metode yang digunakan adalah metodeKagan.Wilayah Sungai Wae-Jamal terletak di Propinsi NTT khususnya Pulau Flores. WS Wae-Jamal mempunyailuas 6623,55 km2 dan memiliki jumlah stasiun yang aktif adalah 7 buah stasiun.Hubungan jarak dan besarnya curahhujan yang ditunjukan oleh koefisien korelasi untuk hujan harian diperoleh 0,412 dan curah hujan bulanan 0,123.Kedua nilai koefisien korelasi ini, menunjukkan korelasi yang lemah antar stasiun hujan dalam WS Wae-Jamalsehingga akan menghasilkan data hujan yang kurang akurat. Besarnya kesalahan perataan dengan jumlah 7 stasiunpada WS Wae-Jamal sebesar 11,242 % untuk curah hujan harian dan untuk curah hujan bulanan kesalahannyasebesar 13,809 %. Dari data curah hujan harian, untuk kesalahan 10% diperoleh jumlah stasiun sebanyak (n) = 10buah dengan kerapatan = 662,355 km2/stasiun dan untuk kesalahan 5% jumlah stasiun yang diperoleh (n) = 36 buahdengan kerapatan = 183,988 km2/stasiun, sedangkan curah hujan bulanan diperoleh jumlah stasiun sebagai berikut,kesalahan 10% menghasilkan jumlah stasiun sebanyak (n) = 15 buah dengan kerapatan = 441,57 km2/stasiun dankesalahan 5% diperoleh jumlah stasiun hujan sebanyak (n) = 55 dengan kerapatan = 120,428 km2/stasiun
PERBANDINGAN KUAT TEKAN BATA RINGAN CLC MENGGUNAKAN PASIR GUNUNG BOLENG DAN PASIR TAKARI Eban, Kornelis K.; Utomo, Sudiyo; Simatupang, Partogi H.
Jurnal Teknik Sipil Vol 7, No 2 (2018): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1222.769 KB)

Abstract

Penelitian ini bertujuan untuk mengetahui karakteristik bata ringan yang menggunakan pasir Gunung Boleng sebagai bahan campuran bata ringan Cellular Lighweight Concrete (CLC) terhadap berat volume, kuat tekan, dan serapan air. Metode yang digunakan dalam penelitian ini yaitu pengujian laboratorium yakni dengan membuat bata ringan CLC yang menggunakan pasir Takari sebagai pembanding. Bata ringan CLC yang telah dicuring selama 7, 14, 21, dan 28 hari diuji untuk mendapatkan nilai berat volume, kuat tekan, dan serapan air. Hasil pengujian bata ringan CLC yang menggunakan pasir Takari memiliki nilai berat volume rata-rata selama masa perawatan berturut-turut 0,733 gr/cm3, 0,726 gr/cm3, 0,708 gr/cm3,dan 0,683 gr/cm3lebih besar dari bata ringan CLC yang menggunakan pasir Gunung yaitu 0,643 gr/cm3, 0,625 gr/cm3, 0,611 gr/cm3,dan 0,564 gr/cm3. Nilai kuat tekan bata ringan CLC yang menggunakan pasir Takari selama masa perawatan berturut – turut yakni 0,808 MPa, 0,892 MPa, 0,931 MPa, 0,975 MPa lebih besar dari kuat tekan bata ringan CLC yang menggunakan pasir Gunung Boleng turut yakni 0,592 MPa, 0,642 MPa, 0,708 MPa, 0,814 MPa. Nilai serapan air pada bata ringan CLC yang menggunakan pasir Takari lebih kecil yakni 18,161 % dibandingkan dengan nilai serapan air pada bata ringan CLC yang menggunakan Gunung Boleng yakni 21,747 %.The purpose of this study is to find out the characteristics of light bricks in using the Mount Boleng sand as a lightweight material of lightweight Concrete Lightweight Concrete (CLC) for weight volume, compressive strength and water absorption. The method that is used in this research is laboratory testing that is to make CLC lightweight brick by using Takari sand as the comparison. The Lightweight CLC bricks for 7, 14, 21, and 28 days were tested for weight volume, compressive strength, and the water absorption. The results of the CLC lightweight brick testing used Takari sand have average volume weight values during the treatment periods of 0.733 gr / cm3, 0.726 gr / cm3, 0.708 gr / cm3, and 0.683 gr / cm3 that is larger than the CLC light bricks that use mountain sand that was 0.643 gr / cm3, 0.625 gr / cm3, 0.611 gr / cm3, and 0.564 gr / cm3. The value of CLC lightweight brick which used Takari sand during the treatment period was 0,808 MPa, 0,892 MPa, 0,931 MPa, 0.975 MPa bigger than the CLC light brick strength which used the Gunung Boleng sand which was 0.592 MPa, 0.642 MPa, 0.708 MPa, 0.814 MPa. The water absorption value of CLC light brick that used Takari sand is less than 18,161% compared to the water absorption value of CLC light bricks that used Mount Boleng which is 21,747%.
PENGARUH PENAMBAHAN CACAHAN LIMBAH PLASTIK JENIS HIGH DENSITY POLYETHYLENE (HDPE) PADA Sina, Dantje A. T.; Udiana, I Made; Da Costa, Bernad D.
Jurnal Teknik Sipil Vol 1, No 4 (2012)
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (432.284 KB)

Abstract

Waste is a very complex problem in urban area. Plastic waste is increasing every year. Kupang with population of 291,794 people generate waste reaches 926 m3/day. Organic waste to 700 m3 and inorganic waste about 226 m3. Concrete is planned by strength quality 25 MPa. Based on the analysis in this study obtained that concrete flexural strength value increased due to the addition of HDPE plastic shredded into the concrete, with chopped levels are added to the concrete at 0%, 0.50% and 0.90% .0,70%. Flexural strength value of normal concrete without the addition of shredded plastic (0%) is 4.12 MPa, flexural strength of concrete with the addition of shredded plastic 0.50% is 4.30 MPa increased 4.37% from normal concrete flexural strength, flexural strength of concrete with the addition of shredded plastics 0.70% is 4.21 MPa increased 2.19% from the normal concrete flexural strength and flexural strength of concrete with the addition of shredded plastic 0.90% is 3.94 MPa decreased 3.64% of flexural strength normal concrete.
ANALISIS ATAS GORONG-GORONG JALUR LINGKAR LUAR BENDUNGAN RAKNAMO Touselak, Iin A. L.; Krisnayanti, Denik S.; Simatupang, Partogi H.; Ramang, Ruslan
Jurnal Teknik Sipil Vol 8, No 1 (2019): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (600.44 KB)

Abstract

Bendungan Raknamo berlokasi di Desa Raknamo, Kecamatan Amabi Oefeto, Kabupaten Kupang dan terdapat jalur lingkar luar yang mengelilingi waduk bendungan tersebut. Sepanjang jalur lingkar luar Bendungan Raknamo terdapat 49 titik gorong-gorong yang berfungsi untuk mengalirkan air dari sungai utama Noel Puames maupun anak sungai pada DAS Bendungan Raknamo. Penelitian ini bertujuan untuk mengetahui kapasitas dan kekuatan struktur gorong-gorong pada jalur lingkar luar Bendungan Raknamo. Metode yang digunakan dalam perhitungan debit rencana adalah  metode Rasional dan metode HSS Nakayasu.Hasil analisis debit rencana gorong-gorong CK 9 dengan kala ulang 10 tahun sebesar 10,6559 m3/dtk, sedangkan debit existing gorong-gorong CK 9 sebesar 4,1095 m3/dtk. Oleh karena itu, gorong-gorong CK 9 tersebut perlu diperbesar agar dapat melewatkan debit rencana kala ulang 10 tahun.Hasil analisis struktur gorong-gorong CB 3adalah tegangan kerja maksimum akibat beban-beban yang bekerja sebesar 30,06 kN/m2 pada dinding geser gorong-gorong, sedangkan kekuatan struktur gorong-gorong untuk tegangan ultimate sebesar 1512,95 kN/m2 dan modulus keruntuhan beton sebesar 3492,99 kN/m2. Nilai tegangan kerja maksimum lebih kecil daripada kekuatan struktur gorong-gorong, sehingga tidak terjadi keruntuhan struktur dan tidak terjadi rembesan.Raknamo Dam is located in RaknamoVillage, AmabiOefetoDistrict, KupangRegency and there is an outer ring road arround reservoir area. Along the Raknamo Dam outer ring road, there are 49 culvert points to let the water flow from the main river Noel Puames and the tributaries in RaknamoDam watershed. Thisresearch aimed to determine the capacity and structure strength of culverts on Raknamo Dam outer ring road. Discharge design calculated using Rationalmethod and Synthetic Unit Hydrograph Nakayasu method. The analysis result of water discharge design for CK 9 are10,6559 m3/sec and existing culvert discharge for CK 9are 4,1095 m3/sec. Therefore, the dimension of culvert CK 9 need to be enlarged to drain the water stream with discharge design for 10-year return period. Results of culvert CB 3’s structure analysis are the maximum working stresses due the loads work are30,06kN/m2, while the structure strength for ultimate stresses are 1512,95 kN/m2and the modulus of rupture are 3492,99 kN/m2. The maximum working stresses are smaller than the structure strength, therefore not occurred structural collapse also the seepage
PENGENDALIAN WAKTU DAN BIAYA PEKERJAAN KONSTRUKSI SEBAGAI DAMPAK DARI PERUBAHAN DESAIN Messah, Yunita Afliana; Lona, Lazry Hellen Paula; Sina, Dantje A. T.
Jurnal Teknik Sipil Vol 2, No 2 (2013): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (3053.519 KB)

Abstract

The purpose of this study is to describe the effect of changing control of the design that have an impact on the time and cost of construction work that affects the performance of construction work Embung Irrigation Oenaem. This study used two methods of controlling the Earned Value Analysis (EVA) and integrated method of shortening the duration of the critical path (Crashing Length) at Critical Path Method (CPM) using the application as an alternative to controlling overtime. To use of the two methods mentioned above it can be seen and obtained alternative pengedalian time and construction costs as a result of design changes that occurred in the Irrigation Development Project Embung Oenaem. Based on the analysis that had been done when a deviation occurs at 7 weeks, the total work period to 37 weeks from 30 weeks the amount of time a plan with estimated cost is Rp. 9,489,206,129.03. Then controlled using the method of shortening the duration (Crashing Length) with future application of the overtime work to 35 weeks (5 weeks delay) with the amount of the cost of Rp. 9.458.239.978,70 (excluding VAT) of the total contract value of Rp. Rp. 8.563.635.912,98 (excluding VAT 10%).
STUDI KELAYAKAN TEKNIS PENGGUNAAN PASIR LAUT ALOR KECIL TERHADAP KUALITAS BETON YANG DIHASILKAN Ramang, Ruslan; Sina, Dantje A. T.; Irpan, Muhamad
Jurnal Teknik Sipil Vol 3, No 2 (2014): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (149.903 KB)

Abstract

Pembangunan di Kabupaten Alor khususnya di Desa Alor Kecil masih menggunakan pasir laut untuk dijadikan sebagai bahan agregat halus dalam pembuatan beton. Namun secara ilmiah belum diketahui kualitasnya, sehingga perlu dilakukan kajian atau studi tentang kelayakan kualitas beton dari bahan tersebut. Tujuan penelitian ini adalah untuk mengetahui kelayakan berdasarkan kualitas beton yang dilihat dari nilai kuat tekan serta kuat tarik belah beton menggunakan pasir laut Alor Kecil kondisi asli maupun yang dicuci terlebih dahulu dengan sampel beton pasir takari pada umur 7 hari, 14 hari dan 28 hari. Benda uji yang digunakan adalah beton silinder (diameter 15 cm dan tinggi 30 cm). Metode yang digunakan untuk analisa data adalah statistik deskriptif berupa perbandingan hasil pengujian berupa grafik dan tabel serta perhitungan statistik berupa analisis varians. Berdasarkan hasil uji kualitas diperoleh hasil bahwa untuk kuat tekan beton pasir takari memiliki nilai lebih besar dibandingkan beton pasir laut Alor Kecil baik kondisi asli maupun yang dicuci terlebih dahulu, hal yang sama juga diperoleh untuk pengujian kuat tarik belah beton. Selain itu pengujian kuat tekan untuk semua beton memenuhi kuat tekan perlu yang disyaratkan oleh SNI. Di samping itu, hasil pengujian statistik berupa analisis varians diperoleh kesimpulan bahwa tidak ada perbedaan yang signifikan dari hasil pengujian kuat tekan untuk masing masing sampel beton tersebut.
EVALUASI KINERJA EMBUNG OELTUA Dethan, Yulianthi; Bunganaen, Wilhelmus; Messah, Yunita A.
Jurnal Teknik Sipil Vol 4, No 1 (2015): Jurnal Teknik Sipil
Publisher : Jurnal Teknik Sipil

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (157.161 KB)

Abstract

Di Desa Oeltua Kecamatan Taebenu Kabupaten Kupang telah dibangun sebuah embung sebagai upaya untuk memenuhi kebutuhan air bagi masyarakat. Embung ini dibangun pada Maret 1997. Berdasarkan hasil pengamatan, saat ini Embung Oeltua mengalami penurunan fungsi sehingga penulis memilih embung Oeltua sebagai subyek penelitian untuk mengetahui sejauh mana kinerja Embung Oeltua. Kinerja embung ditinjau dengan menggunakan sistem pendekatan pada aspek-aspek sebagai berikut: aspek ketersediaan air, aspek fisik, aspek pemanfaatan, aspek operasional dan pemeliharaan (O&P), dan aspek manajemen organisasi. Metode yang digunakan dalam penelitian ini yaitu metode survey dan analisis deskriptif, yaitu menguraikan hasil penelitian dengan memberikan nilai tertentu terhadap setiap variabel aspek yang ditinjau. Penilaian yang diberikan dengan menggunakan metode skala likert yakni pengukuran terhadap sikap, pendapat dan persepsi seseorang atau sekelompok tentang kejadian atau gejala sosial. Kejadian atau gejala sosial ditetapkan secara spesifik sebagai variabel penelitian. Berdasarkan hasil analisis, diperoleh nilai aspek ketersediaan air pada Embung Oeltua sebesar 5,00 dengan kondisi sangat baik, nilai aspek fisik sebesar 4,15 dengan kondisi baik, nilai aspek pemanfaatan sebesar 3,58 dengan kondisi baik, nilai aspek operasional sebesar 1,88 dengan kondisi tidak baik, nilai aspek manajemen organisasi sebesar 1,00 dengan kondisi sanga tidak baik. Hasil analisis untuk kinerja Embung Oeltua dengan nilai 3,12, berada pada kondisi cukup baik. In the Village Oeltua, Sub-district Taebenu, District Kupang has built a dam to meet water needs for the community. This Dam was built in March 1997. Based on observations, Oeltua Dam has experienced a decline in function so that the authors chose Oeltua Dam as research subjects to determine the extent to which performance of Oeltua Dam. The performance of Dam is reviewed using a system approach on the following aspects: the availability of water aspect, the physical aspect, the aspect of utilization, operational and maintenance aspect (O & M), and management aspects of the organization. The method used in this study is a survey method and descriptive analysis, which describes the results of research by providing specific values for each variable aspect reviewed. Assessment is given by using the Likert scale method, that is by measuring the attitudes, opinions and perceptions of a person or group of events or social phenomena. Events or social phenomena defined specifically as research variables.Based on the analysis, obtained value of the availability of water in Oeltua Dam is 5.00 with a very good condition, the value of the physical aspects is 4,15 with a good condition, the value of the aspects of utilization is 3,58 with a good condition, the value of the operational and maintenance aspects is 1,88 with a not good condition, the value of management aspects of organization is 1,00 with a not very good condition. The results of the analysis for the performance of Oeltua Dam with values 3.12, to be a fairly good condition.

Page 7 of 19 | Total Record : 185