cover
Contact Name
Nizirwan Anwar
Contact Email
nizirwan.anwar@esaunggul.ac.id
Phone
-
Journal Mail Official
telkomnika@ee.uad.ac.id
Editorial Address
Ahmad Yani st. (Southern Ring Road), Tamanan, Banguntapan, Bantul, Yogyakarta 55191, Indonesia
Location
Kota yogyakarta,
Daerah istimewa yogyakarta
INDONESIA
TELKOMNIKA (Telecommunication Computing Electronics and Control)
ISSN : 16936930     EISSN : 23029293     DOI : 10.12928
Core Subject : Science,
Submitted papers are evaluated by anonymous referees by single blind peer review for contribution, originality, relevance, and presentation. The Editor shall inform you of the results of the review as soon as possible, hopefully in 10 weeks. Please notice that because of the great number of submissions that TELKOMNIKA has received during the last few months the duration of the review process can be up to 14 weeks. Communication Engineering, Computer Network and System Engineering, Computer Science and Information System, Machine Learning, AI and Soft Computing, Signal, Image and Video Processing, Electronics Engineering, Electrical Power Engineering, Power Electronics and Drives, Instrumentation and Control Engineering, Internet of Things (IoT)
Articles 3,452 Documents
A new resonant-based sensor for non-invasive measurement of blood glucose levels Abolfazl Bijari; Faeze Foolad; Mohammadreza Khorshidi
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 4: August 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i4.26280

Abstract

This paper presents a rapidly developed non-invasive microstrip sensor for measuring blood glucose levels (BGLs). The sensor features a microstrip closed-loop square resonator integrated with an interdigital capacitor (IDC), creating a sensitive area for glucose detection when a patient’s finger is placed on it. Using odd and even mode analytical methods and transmission line theory, we analyzed the sensor’s performance. Results indicate that the second even mode demonstrates significant changes across a standard glucose concentration range. The sensor was designed and simulated in ANSYS high frequency structure simulator (HFSS), showing a resonance frequency shift of up to 24.9 MHz at 1.94 GHz and a sensitivity of 110 kHz per mg/dL over a detection range of 0 to 216 mg/dL. Additionally, the frequency shift exhibits a high linear correlation (0.9485). In summary, the proposed sensor shows significant promise for achieving precise measurements of BGLs.
PSO optimization on backpropagation for fish catch production prediction Yuslena Sari; Eka Setya Wijaya; Andreyan Rizky Baskara; Rico Silas Dwi Kasanda
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 18, No 2: April 2020
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v18i2.14826

Abstract

Global climate change is an issue that is enough to grab the attention of the world community. This is mainly because of the impact it has on human life. The impact that is felt also occurs in waters on the South Kalimantan region. This is of course can disrupt the productivity of fish in the marine waters of South Kalimantan. This study aims to make fish catch production prediction models based on climate change in the South Kalimantan Province because the amount of productivity of marine fish has fluctuated. This study uses climate data as input and fish production as output which is divided into two, namely training and testing data. Then the prediction is conducted using Backpropagation method combined with Particle Swarm Optimization method. The results of the study produced a prediction model with RMSE of 0.0909 with a combination of parameters used, namely, C1: 2, C2: 2, w: 0.7, learning rate: 0.5, Momentum: 0.1, Particles: 5, and epoch: 500. While the model used when predicting testing data produces RMSE of 0.1448.
Performance enhancement of FSO link with RIS-aided over Weibull distribution for 5G/6G and IoT applications Duong Huu Ai; Van Loi Nguyen; Hoang Huu Duc; Khanh Ty Luong; Viet Truong Le
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 1: February 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i1.25535

Abstract

With continuous development of wireless communication and internet of things (IoT) technology enables many terminals to be interconnected with each other through the external environment by wireless communication. Along with that, 5G/6G technology provides services with enhanced quality and high data transmission speeds, requiring the implementation of IoT in the 5G/6G architecture. Free space optical (FSO) communication is considered as a promising technique that can connect IoT devices by high-speed communication link, so for wireless networks to fully realize the potential of 5G/6G technology providing speeds of 100 Gb/s or more, FSO is the optimal choice. By implementing FSO features in IoT, the performance and convegare of IoT will be improved and enhanced by using techniquaes for FSO systems. Therefore, this paper proposed and investigated the FSO communication system using reconfigurable intelligent surfaces (RISs) over Weibull distribution. The performance of system is evaluated according to the average channel capacity (ACC) parameters in the case with and without RIS, while the the different of the model is changed. The average spectral efficiency (ASE) parameters can also be represented ACC.
Gain enhanced 5.8 GHz patch antenna with defected ground structure: design and measurement Md. Nahid Hasan; Md. Sohel Rana
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 5: October 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i5.26755

Abstract

A rectangular microstrip patch antenna including a rectangular defective ground structure (DGS) is introduced to simultaneously enhance gain, bandwidth, and return loss while reducing antenna dimensions. This small antenna is engineered for 5.8 GHz applications, functioning throughout the frequency spectrum of 5.62 to 5.94 GHz. The design was executed on a 1.6 mm thick FR-4 substrate with a relative permittivity of 4.3, utilizing a microstrip line feed. The dimensions of the antenna are 31.75×28 ×1.6 mm³. The design approach utilized computer simulation technology (CST) Microwave Studio simulation software. The antenna attains resonance at 5.8 GHz, providing an initial bandwidth of 270 MHz and a return loss of -26 dB. A rectangular DGS was implemented to boost performance, yielding a 21.89% increase in bandwidth to 323 MHz and substantially enhancing the return loss from -23 dB to -47 dB. The gain increased from 3.95 dBi to 5.10 dBi, indicating a 30% enhancement, while sustaining an efficiency of around 83% at the resonant frequency. The antenna was constructed, and experimental measurements of parameters including gain and return loss closely matched the computer results.
Compact miniaturized antenna design and development for a leadless cardiac pacemaker Abdelmouttalib Bousrout; Asma Khabba; Saida Ibnyaich; Tomader Mazri; Mohamed Habibi; Tole Sutikno
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 6: December 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i6.25958

Abstract

Biomedical antennas play a crucial role in implantable medical telemetry, improving patient monitoring and overall well-being. This study presents a compact antenna designed for a lead-free pacemaker, with dimensions of 3.3×4×0.5 mm³. Miniaturization required open cuts in the ground plane and radiating patch, as well as a localized resistance element. The antenna features an exceptional bandwidth of 1646.8 MHz (1.0602-2.7070) GHz, guaranteeing constant performance in the human body. It covers the industrial, scientific and medical bands (ISM, 2.4-2.48 GHz) and ultra-high frequencies (UHF, 0.3-13 GHz). Simulation in a phantom produced a gain of -19.78 dBi at 2.45 GHz and -34.44 dBi at 1.2 GHz. Safety was confirmed by a specific absorption rate (SAR) study using a cardiac model. The antenna’s low SAR (10 g-Avg) enabled maximum input powers to be established: 20.2 mW at 1.2 GHz and 21.23 mW at 2.45 GHz. Comparative simulations using high-frequency structure simulator (HFSS) and computer simulation technology (CST) highlighted the antenna’s superiority over recent systems, demonstrating its effectiveness in the human heart. This antenna represents an advanced solution for improving patient care. Consequently, this antenna emerges as an advanced solution for addressing infectious diseases and cardiovascular conditions in the realm of medical advancements.
Bragg reflector one-dimensional multi-layer structure sensor for the detection of thyroid cancer cells Ranjeet Kumar Pathak; Sumita Mishra; Preeta Sharan
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 21, No 3: June 2023
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v21i3.24282

Abstract

In the proposed work, a defect cavity multi-layer Bragg reflector structure is proposed theoretically to find the presence of thyroid cancer cells in the given sample. The modelling, design and analysis of the sensor is performed using characteristic matrix method (CMM). Proposed structure has central defect cavity with 6 pairs of low and high refractive index layers on each side of the defect. To enhances the sensor sensitivity, the incident light in mid-infrared frequency range is used as input light source. The refractive index of normal and thyroid cancer cells is analysed for the performance of the sensor. The obtained Q factor and sensitivity of the sensor design is 3729 and 2828 nm/RIU respectively. The proposed sensor is a best choice of optical sensor for the detection of thyroid cancer cells in the given test sample for accurate analysis in medical applications.
Advanced pneumonia classification using transfer learning on chest X-ray data with EfficientNet and ResNet Green Arther Sandag; Timothy J. Mulalinda; Gloria A. M. Susanto; Stenly R. Pungus
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 5: October 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i5.26387

Abstract

Pneumonia is a serious lung infection that demands accurate and timely diagnosis to reduce mortality. This study explores the use of deep learning and transfer learning for classifying chest X-ray images into two categories: normal and pneumonia. A total of 5,632 labeled images were used to train and evaluate six pre-trained convolutional neural network (CNN) architectures: EfficientNetB1, B3, B5, B7, ResNet50, and ResNet101. The models were tested across three training scenarios by varying learning rates (LR), batch sizes, and epochs. Among all models, EfficientNetB3 achieved the highest performance, with accuracy of 99.04%, precision of 99.76%, recall of 99.23%, and F1-score of 99.34%. These results indicate that EfficientNetB3 offers a robust and efficient solution for pneumonia detection. This research contributes to the development of intelligent diagnostic tools in the medical field and provides practical guidance for selecting effective deep learning models in clinical imaging applications.
Readiness measurement of IT implementation in Higher Education Institutions in Indonesia Mohamad Irfan; Syopiansyah Jaya Putra
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 18, No 2: April 2020
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v18i2.14902

Abstract

This article elaborates the result of the Pilot Study which is related to IT implementation factors at the Higher Education Institution (HEI), a pilot study is used to validate quantitative readiness model of IT implementation. The main objective of this study is examining the factors that influence the readiness of IT implementation in HEI. This study attempts to analyze IT Content factors, Institutional Context, People, Process, Technology, Service Quality and IT Implementation Readiness (ITIR). The sample of data was taken from 150 HEIs throughout Indonesia which was then processed in statistical techniques through PLS-SEM method. The research finding shows that 9 of the 14 hypotheses used as ITIR model construct have a very significant influence on IT implementation on HEI, so that this finding can provide a comprehensive contribution to the literature of ITIR model development.
Performance of piezoelectric energy harvester with various ratio substrate and micro windmill Adhes Gamayel; Ade Sunardi
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 22, No 2: April 2024
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v22i2.25691

Abstract

One of the mechanical energy harvesters, piezoelectric energy harvesters (PEHs), produces electricity in response to an external load, which leads to stress and strain in the cantilever beam. The study focused on performance PEH due to collisions between micro windmill blades and PEH substrate. The substrate has dimensions of 10 cm × 6 cm × 1 mm in length, width, and thickness, respectively. Experimental setup was in wind tunnel with a cross-section of 250 mm × 250 mm and blower to generated wind flow inside the tunnel. The wind speeds were set up at 6, 7, and 8 m/s, and then three ratios, namely 1:1, 1:2, and 1:3, were analyzed in output voltage and the deflection. The performance of energy harvesting in a ratio of 1:1 and wind speed of 8 m/s produces a deflection of 2.05 cm, the highest voltage of 12.67 volts, and an effective voltage of 5.62 volts. It was found that ratio 1:1 has a greater mass weight and cross-section than others, leading to more curvature in the PEH beam when the collision occurs. Besides that, the high speed of the micro windmill rotation causes collisions between the blades and PEH to become more frequent.
Lightning studies on effects on distribution lines: a bibliometric analysis Vladimir Henao - Céspedes; Luis Fernando Díaz - Cadavid
TELKOMNIKA (Telecommunication Computing Electronics and Control) Vol 23, No 6: December 2025
Publisher : Universitas Ahmad Dahlan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.12928/telkomnika.v23i6.26976

Abstract

The study of lightning effects on distribution lines is of vital importance for the reliability and safety of electrical systems, as lightning is one of the main causes of failures. The purpose of this study is to perform a bibliometric analysis to evaluate academic productivity trends and research trajectories in this field. The methodology was based on a comprehensive search of the Scopus database, from which a total of 545 articles published between 1932 and 2024 were analyzed. For the analysis, the VOSviewer tool and the Bibliometrix library in R were used. The results reveal a constant increase in productivity since the 1970s, with Japan and China emerging as the most prolific countries. The research has evolved from early theoretical and experimental studies toward the use of advanced computational models and, more recently, the application of machine learning techniques for fault detection. In conclusion, the findings of this study provide a consolidated view of the field, which is fundamental for engineers to be able to design more robust protection systems and to guide future research toward model validation and the integration of renewable energy technologies.

Filter by Year

2004 2026


Filter By Issues
All Issue Vol 24, No 4: August 2026 Vol 24, No 3: June 2026 Vol 24, No 2: April 2026 Vol 24, No 1: February 2026 Vol 23, No 6: December 2025 Vol 23, No 5: October 2025 Vol 23, No 4: August 2025 Vol 23, No 3: June 2025 Vol 23, No 2: April 2025 Vol 23, No 1: February 2025 Vol 22, No 6: December 2024 Vol 22, No 5: October 2024 Vol 22, No 4: August 2024 Vol 22, No 3: June 2024 Vol 22, No 2: April 2024 Vol 22, No 1: February 2024 Vol 21, No 6: December 2023 Vol 21, No 5: October 2023 Vol 21, No 4: August 2023 Vol 21, No 3: June 2023 Vol 21, No 2: April 2023 Vol 21, No 1: February 2023 Vol 20, No 6: December 2022 Vol 20, No 5: October 2022 Vol 20, No 4: August 2022 Vol 20, No 3: June 2022 Vol 20, No 2: April 2022 Vol 20, No 1: February 2022 Vol 19, No 6: December 2021 Vol 19, No 5: October 2021 Vol 19, No 4: August 2021 Vol 19, No 3: June 2021 Vol 19, No 2: April 2021 Vol 19, No 1: February 2021 Vol 18, No 6: December 2020 Vol 18, No 5: October 2020 Vol 18, No 4: August 2020 Vol 18, No 3: June 2020 Vol 18, No 2: April 2020 Vol 18, No 1: February 2020 Vol 17, No 6: December 2019 Vol 17, No 5: October 2019 Vol 17, No 4: August 2019 Vol 17, No 3: June 2019 Vol 17, No 2: April 2019 Vol 17, No 1: February 2019 Vol 16, No 6: December 2018 Vol 16, No 5: October 2018 Vol 16, No 4: August 2018 Vol 16, No 3: June 2018 Vol 16, No 2: April 2018 Vol 16, No 1: February 2018 Vol 15, No 4: December 2017 Vol 15, No 3: September 2017 Vol 15, No 2: June 2017 Vol 15, No 1: March 2017 Vol 14, No 4: December 2016 Vol 14, No 3: September 2016 Vol 14, No 2: June 2016 Vol 14, No 1: March 2016 Vol 13, No 4: December 2015 Vol 13, No 3: September 2015 Vol 13, No 2: June 2015 Vol 13, No 1: March 2015 Vol 12, No 4: December 2014 Vol 12, No 3: September 2014 Vol 12, No 2: June 2014 Vol 12, No 1: March 2014 Vol 11, No 4: December 2013 Vol 11, No 3: September 2013 Vol 11, No 2: June 2013 Vol 11, No 1: March 2013 Vol 10, No 4: December 2012 Vol 10, No 3: September 2012 Vol 10, No 2: June 2012 Vol 10, No 1: March 2012 Vol 9, No 3: December 2011 Vol 9, No 2: August 2011 Vol 9, No 1: April 2011 Vol 8, No 3: December 2010 Vol 8, No 2: August 2010 Vol 8, No 1: April 2010 Vol 7, No 3: December 2009 Vol 7, No 2: August 2009 Vol 7, No 1: April 2009 Vol 6, No 3: December 2008 Vol 6, No 2: August 2008 Vol 6, No 1: April 2008 Vol 5, No 3: December 2007 Vol 5, No 2: August 2007 Vol 5, No 1: April 2007 Vol 4, No 3: December 2006 Vol 4, No 2: August 2006 Vol 4, No 1: April 2006 Vol 3, No 3: December 2005 Vol 3, No 2: August 2005 Vol 3, No 1: April 2005 Vol 2, No 1: April 2004 More Issue