cover
Contact Name
-
Contact Email
-
Phone
-
Journal Mail Official
-
Editorial Address
-
Location
Kota malang,
Jawa timur
INDONESIA
Jurnal Mahasiswa TEUB
Published by Universitas Brawijaya
ISSN : -     EISSN : -     DOI : -
Core Subject : Education,
Arjuna Subject : -
Articles 18 Documents
Search results for , issue "Vol 9, No 1 (2021)" : 18 Documents clear
DESAIN DAN IMPLEMENTASI MODEL REFERENCE ADAPTIVE SYSTEM (MRAS) PADA SISTEM KONTROL KECEPATAN MOTOR DC MINERTIA TIPE UGTMEM-03STC25 Patriot Keliat; Goegoes Dwi Nusantoro; Tri Nurwati
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Plant Motor DC Minertia tipe UGTMEM-03STC25 merupakan salah satu panel pelatihan di Laboratorium Sistem Kontrol Universitas Brawijaya Malang. Motor DC memiliki respon yang cepat namun masih memiliki error steady state. Oleh karena itu diperlukan suatu sistem kontrol untuk mendapatkan kestabilan kecepatan motor. Penerapan Model Reference Adaptive System (MRAS) dengan kontroler PI pada plant Motor DC-Minertia bertujuan agar respon sistem memiliki settling time kurang dari 2 detik, tidak memiliki error steady state, dan memiliki Maximum overshoot (Mp) kurang dari 5%. Fungsi alih motor DC-Minertia merupakan orde dua dengan best fit 67,54%, diperoleh dari pemodelan dengan membangkitkan sinyal Pseudo Random Binary Sequence (PRBS). Dalam mendesain kontroler PI menggunakan metode MRAS, struktur model referensi diperoleh berdasarkan fungsi alih sistem closed loop. Parameter kontrol ditentukan menggunakan MIT Rule yaitu dengan meminimalisasi loss function . Berdasarkan simulasi yang dilakukan maka didapatkan parameter gain kontroler yang ideal, dengan  dan . Pada implementasi sistem dengan perubahan setpoint, sistem membutuhkan 2 detik untuk mencapai keadaan steady namun di perubahan setpoint berikutnya sistem hanya membutuhkan 0,5 detik. Kata Kunci: Motor DC, Model Reference Adaptive System (MRAS), kontroler PI, MIT Rule, PRBS ABSTRACT UGTMEM-03STC25 Minertia DC Motor plant is one of the training panels in the Control System Laboratory of Brawijaya University Malang. The DC motor has a fast response but still has a steady state error. Therefore we need a control system to get the motor speed stability. The application of the Model Reference Adaptive System (MRAS) with a PI controller at the DC-Minertia Motor plant aims to ensure that the system response has a settling time of less than 2 seconds, has no steady state error, and has a Maximum overshoot (Mp) of less than 5%. The DC-Minertia motor transfer function is second order system with a best fit of 67.54%, obtained from modeling by generating a Pseudo Random Binary Sequence (PRBS) signal. In designing the PI controller using the MRAS method, the reference model structure is obtained based on the closed loop system transfer function. Control parameters are determined using the MIT Rule, namely by minimizing the loss function . Based on the simulation, the ideal controller gain parameter is obtained, with γp = 0,269 and γi = 46,18. In a system implementation with a change in setpoint, the system needs 2 seconds to reach a steady state, but at the next setpoint change, the system only takes 0.5 seconds. Keywords: DC Motor, Model Reference Adaptive System (MRAS), PI Controller, MIT Rule, PRBS
RANCANG BANGUN SMART HOME DENGAN DELAPAN INTEGRASI PERANGKAT BERBASIS PROGRAMMABLE LOGIC CONTROLLER (PLC) Iqbal Alfawwazi Hakim; Mochammad Rusli; Bambang Siswojo
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Smart home atau rumah cerdas merupakan rumah yang menyediakan kenyamanan, keamanan, efisiensi energi bagi penghuninya. Seluruh perangkat keras yang akan dirancang akan diintegrasikan menggunakan Programmable Logic Controller (PLC) dengan pemrograman menggunakan Ladder diagram yang nantinya akan diimplementasikan pada perangkat lunak CX-Programmer. Perangkat input yang digunakan berupa sensor float switch, sensor PIR, sensor Infrared, sensor Ultrasonik, rain sensor, sensor MQ-7, sensor getaran, dan push button. Serta perangkat output yang digunakan adalah Solenoid Valve, lampu, motor pompa, motor servo, dan buzzer. Hal ini juga dibantu oleh Relay module yang berfungsi mengendalikan sirkuit tegangan tinggi dengan bantuan dari signal tegangan rendah pada perangkat input yang memiliki tegangan lebih rendah dari tegangan pada port input PLC. Kesimpulan yang dapat diambil adalah sistem Smart home yang berbasis PLC Omron CP1E N20DRA ini dapat berjalan sesuai apa yang telah diharapkan dan dirancang dengan mengandalkan dua belas input yang terintegrasi dengan Relay module serta delapan output. Kata Kunci: Smart home, Programmable Logic Controller, CP1E.   ABSTRACT   Smart home is a home that provides comfort, security, energy efficiency for its residents. All hardware to be designed will be integrated using Programmable Logic Controller (PLC) with programming using the Ladder diagram, which will be implemented in CX-Programmer software. Input devices used in the form of float switch sensors, PIR sensors, Infrared sensors, Ultrasonic sensors, rain sensors, MQ-7 sensors, vibration sensors, and push-buttons. As well as the output devices used are Solenoid Valve, lamps, pump motors, servo motors, and buzzers. It is also assisted by a Relay module that serves to control high voltage circuits with the help of low voltage signals on input devices that have a voltage lower than the voltage on the PLC input port. The conclusion that can be taken is that the Smart home System based on OMRON CP1E N20DRA PLC can run as expected and designed by relying on twelve inputs integrated with the relay module and eight outputs. Keywords: Smart home, Programmable Logic Controller, CP1E.
PENGARUH VARIASI PANJANG SIRIP PADA ISOLATOR POLIETILEN TERHADAP NILAI ARUS BOCOR Ahmad Reza Yahya; Mochammad Dhofir; Hadi Suyono
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penelitian ini menganalisa pengaruh variasi panjang sirip dari bentuk permukaan isolator terhadap tingkat arus bocor dan tegangan flashover pada kondisi kering dan basah, dimana isolator yang digunakan dalam penelitian ini terbuat dari bahan polietilen. Pada penelitian ini diterapkan tiga variasi panjang sirip. Bentuk isolator terdiri dari dua jumlah sirip dengan jarak rambat yang sama yaitu sebesar 18 cm.  Metode penelitian yang digunakan adalah dengan mengambil data arus bocor dan tegangan flashover secara langsung yang dilakukan di Laboratorium Tegangan Tinggi Universitas Brawijaya. Pengujian ini menggunakan tegangan tinggi AC. Pengujian dilakukan dalam dua tipe kondisi yaitu kering dan basah dimana pada pengujian dalam kondisi basah menggunakan debit pembasahan sebesar 30 mL/s yang mengacu pada data tren curah hujan di indonesia. Hasil yang didapat pada penelitian ini antara lain pengaruh variasi panjang sirip terhadap distribusi medan listrik, arus bocor dan tegangan flashover adalah arus bocor akan mengalami peningkatan pada kondisi basah sehingga mempercepat terjadinya fenomena tegangan flashover dan terjadinya peningkatan rugi daya, serta distribusi medan listrik pada permukaan isolator yang tidak seragam. Kata kunci: Isolator Polietilen, Arus Bocor, Tegangan Flashover, Variasi Panjang Sirip This study analyze about effect of  the variation of shed length to the insulator creepage on leakage current dan flashover voltage over dry and wet condition, where the insulator that used in this research made from polyethelene material. In this study, three variation of the shed length were aplied. The form of the insulator consists of two numbers of shed with the same creepage distance of 18 cm. The research method used is to take the leakage current and flashover voltage data directly which is carried out at the High Voltage Laboratory of Brawijaya University. This test uses a high voltage AC circuit. The test has two types of conditions, namely dry and wet where the wet test uses a wetting rate of 30 mL / s which refers to the rainfall trend data in Indonesia. The results obtained in this study are there are effects of varation of shed length to the insulator creepage on electric field distribution, leakage current and flashover voltage over dry and wet condition that the leakage current will increase in wet conditions, thereby accelerating the phenomenon of flashover voltage and an increase in power loss, as well as the non-uniform distribution of the electric field on the insulator surface. Keywords: Polyethylene Isolator, Leakage Current, Flashover Voltage, Variation of shed Length
IMPLEMENTASI SISTEM KONTROL PID DAN MONITORING BERBASIS IOT PADA KELEMBAPAN TANAH TANAMAN CABAI Ergan Pratu Handistya; n/a Rahmadwati; Muhammad Aziz Muslim
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Kelembapan tanah adalah jumlah air yang ditahan di dalam tanah setelah kelebihan air dialirkan, apabila tanah memiliki kadar air yang tinggi maka kelebihan air tanah dikurangi melalui evaporasi, transpirasi dan transpor air bawah tanah (Budi, 2009).  Secara umum tanaman cabai dapat ditanam di area sawah maupun tegal, di dataran tinggi maupun rendah. Namun demikian, ada beberapa persyaratan yang diperlukan agar tanaman cabai dapat tumbuh dengan baik seperti ketinggian tempat, iklim, air, tanah, dan kelembapan. Kelembapan dapat berupa kelembapan pada udara maupun kelembapan tanah. Kelembapan tanah yang sesuai dengan tanaman cabai adalah 50%-60%. Semakin rendah kelembapan tanahnya, maka tanaman cabai akan mengalami kekerdilan tidak maksimal dan semakin tinggi kelembapan tanahnya maka tanaman cabai akan layu (www.pens.ac.id.2013). Oleh sebab itu maka diperlukan upaya pengaturan kelembapan tanah yang baik dan efisien. Suatu sistem yang dapat mengontrol kelembapan tanah secara otomatis sangat diperlukan guna mengatasi hal tersebut, yaitu implementasi sistem kontrol pid dan monitoring berbasis iot pada kelembapan tanah tanaman cabai. Pada penggunaan kontroler PID didapatkan nilai parameter Kp= 3, Ki= 0,075, dan Kd= 30, sehingga dapat mempercepat sistem untuk mencapai keadaan steadystate sesuai dengan setpoint yang telah ditentukan berupa kelembapan tanah 60%. Kata Kunci: Sistem Kontrol PID, Berbasis IoT, Kelembapan Tanah, Kontroler PID, Ziegler Nichols 1.   Abstract Soil moisture is the amount of water that is retained in the ground after excess water is drained, if the soil has a high water content, the excess groundwater is reduced through evaporation, transpiration and underground water transport (Budi, 2009). In general, chili plants can be planted in rice fields, in the high and lowlands. However, there are a number of requirements needed for chili plants to grow well, such as altitude, climate, water, soil and humidity. Humidity can be in the form of humidity in the air or moisture in the soil. Soil humidity suitable for chili plants is 50% -60%. The lower the soil moisture, the chili plants will experience less optimal dwarfism and the higher the soil moisture, the chili plants will wither (www.pens.ac.id.2013). Therefore, it is necessary to regulate soil moisture that is good and efficient. A system that can control soil moisture automatically is needed to overcome this, namely Implementation Of The PID Control System And IoT-Based Monitoring Of Soil Moisture Of Chilli Plants. When using the PID controller, the parameter values ​​of Kp = 3, Ki = 0,075, and Kd = 30 are obtained, so that it can accelerate the system to reach a steadystate state in accordance with the predetermined setpoint in the form of 60% soil moisture. Keywords: PID Control System, IoT Based, Soil Moisture, PID Controller, Ziegler Nichols 1.
ANALISIS SISTEM PENTANAHAN ELEKTRODA RADIAL DENGAN PENAMBAHAN TANAH KATEL Avif Septian Imandyan; Mochammad Dhofir; Mahfudz Shidiq
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Abstrak— Dalam penyaluran energi listrik biasannya ditemukan gangguan yang mengakibatkan terhambatnya penyaluran energi listrik ke konsumen. Penyebab yang terjadi biasannya gangguan antara peralatan dengan peralatan atau peralatan dengan manusia bahkan terjadi akibat pengaruh dari lingkungan. Salah satunya yang dapat merusak peralatan akibat lingkungan adalah sambaran petir. Akibatnya perlu sistem pentanahan yang efektif yang dapat mengamankan sistem atau peralatan dari hubung singkat ke tanah. Dalam penelitian ini akan dilakukan perbaikan pada tanah dengan melakukan penambahan tanah katel pada sistem pentanahan elektroda radial dengan beberapa variasi kedalaman tanam elektroda dan variasi panjang elektroda. Pengukuran dilakukan dengan menggunakan tanah di lokasi dan menggunakan penambahan tanah katel. Variasi kedalaman elektroda adalah 20 cm, 40 cm, 60 cm, 80 cm dan 100 cm. Variasi panjang elektroda radial adalah model A (100 cm), model B (200 cm), model C (300 cm), dan model D (400 cm). Pengukuran tahanan pentanahan menggunakan metode 3-node. Dari hasil penelitian didapatkan nilai tahanan pentanahan terendah pada elektroda model D dengan kedalaman tanam 100 cm dengan penambahan tanah katel sebesar 15,53 ohm. Kata kunci — Sistem pentanahan, Elektroda radial, Tanah katel.   Abstract—. In the distribution of electrical energy is usually found disruptions that result in the inhibition of the distribution of electrical energy to consumers. The cause of the usual disturbance between equipment and equipment or equipment with humans even occurs due to the influence of the environment. One of them that can damage equipment due to the environment is lightning strikes. As a result, it is necessary an effective grounding system that can secure the system or equipment from a short circuit to the ground.The research will conduct the soil refinement by addition of alluvial soil to a radial electrode grounding system with some variations in the depth of electrode planting and variation of electrode length. Measurements are made using soil on location and using the addition of alluvial soil. The variations in the depth of the electrode were 20 cm, 40 cm, 60 cm, 80 cm and 100 cm. The variations for the radial electrode length are model A (100 cm), model B (200 cm), model C (300 cm), and model D (400 cm). Measurement of grounding resistance using the 3-node method. From the research results, the lowest grounding resistance value was obtained at the model D electrode with depth of planting100 cm using alluvial soil addition of 15.53 ohm. Keywords— Grounding system, Radial electrode, Alluvial soil.
ANALISIS PENGARUH VARIASI BEBAN TERHADAP KINERJA EARTH LEAKAGE CIRCUIT BREAKER (ELCB) Hatorangan, Orlando; Hasanah, Rini Nur; Suyono, Hadi
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Earth Leakage Circuit Breaker (ELCB) merupakan pemutus yang peka terhadap arus bocor, yang dapat memutuskan sirkuit termasuk penghantar netralnya secara otomatis dalam waktu tertentu. ELCB merupakan komponen listrik yang melindungi dari sengatan listrik atau arus bocor. Jenis beban listrik dibagi menjadi dua yaitu beban resistif dan beban resistif campuran. Variasi beban mempengaruhi kinerja dari ELCB. Dalam penelitian ini, variasi daya aktif pada beban ada 4 untuk 100 W, 225 W, 450 W dan 900 W. Variasi daya reaktif pada beban berdasar nilai faktor daya dari 0.707 sampai dengan 1. Penelitian ini dilakukan dengan bantuan software SIMULINK MATLAB dengan rangkaian sederhana dari ELCB yang diatur hingga rangkaian ELCB trip dan menemukan nilai arus bocor yang menyebabkan ELCB trip. Berdasarkan hasil simulasi dengan variabel di atas, diketahui nilai arus bocor yang menyebabkan ELCB trip untuk variasi daya 100 W dari rentang 31,337 mA sampai dengan 21,645 mA. Untuk daya 225 W dari rentang 30,089 mA sampai dengan 22,258 mA. Untuk daya 450 W dari rentang 29,582 mA sampai dengan 22,004 mA. Untuk daya 900 W dari rentang 29,357 mA sampai dengan 20,703 mA. Kata Kunci : Earth Leakage Circuit Breaker (ELCB), Arus bocor, Daya Aktif, Daya Reaktif, Trip. ABSTRACT Earth Leakage Circuit Breaker (ELCB) is a breaker that is sensitive to leakage currents, which can break the circuit including its neutral conductor automatically at a certain time. The ELCB is an electrical component that protects against electric shock or leakage currents. Types of electric loads are divided into two, namely linear loads and non-linear loads. Non linear load affects the performance of the ELCB. In this research, the variation of the active power at the load was 4 to 100 W, 225 W, 450 W and 900 W. The variation of the reactive power at the load was based on the power factor value from 0.707 to 1. This research was conducted with the help of SIMULINK MATLAB software with a simple circuit. from the set ELCB to the ELCB trip and find the leakage current value that causes the ELCB to trip. Based on the simulation results with the variables above, it is known the value of the leakage current that causes the ELCB to trip for a power variation of 100 W from 31.337 mA - 21.645 mA. For 225 W power from 30.089 mA - 22.258 mA. For 450 W power from 29,582 mA - 22,004 mA. For 900 W power 29,357 mA - 20,703 mA. Keywords : Earth Leakage Circuit Breaker (ELCB), Leakage Current, Active Power, Reactive Power, Trip.
ANALISIS PERFORMANSI ENERGY HARVESTING DEMO BOARD DENGAN PEMBEBANAN MIKROKONTROLER Novia Alifianti; Onny Setyawati; Adharul Muttaqin
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Tegangan keluaran dan arus keluaran yang dihasilkan oleh DC2509A energy harvesting demo board sangatlah rendah, sehingga tidak semua piranti elektronik dapat dihidupkan oleh DC2509A energy harvesting demo board. NodeMCU ESP8266 memiliki suplai tegangan dan arus yang rendah yaitu sebesar 3,3 Volt 50mA dan sangat mudah ditemukan di pasaran, selain itu dalam mikrokontroler tersebut telah tersematkan Wi-Fi, sehingga dapat dipantau dengan jarak jauh. Analisis diperlukan untuk membahas tentang karakterisasi dari mikrokontroler yang dijadikan beban untuk DC2509A dan performansi dari DC2509A energy harvesting demo board dengan memperhatikan konsumsi daya oleh beban yang terhubung dengan board tersebut. Tujuan penelitian ini adalah menganalisis daya yang dikeluarkan oleh DC2509A energy harvesting demo board untuk menghidupkan NodeMCU ESP8266 yang merupakan mikrokontroler eksternal yang tidak didesain khusus untuk DC2509A energy harvesting demo board. Setelah analisis dilakukan dapat diketahui kondisi waktu operasional DC2509A untuk menghidupkan NodeMCU ESP8266. Kata kunci: energy harvesting, DC2509A, Node MCU ESP8266, karakteristik ABSTRACT The output voltage and output current generated by the DC2509A energy harvesting demo board was very low. Therefore not all of the electronic devices could be powered by the DC2509A energy harvesting demo board. NodeMCU ESP8266 has a low voltage and current supply, 3.3 Volt 50 mA, and very easy to find in a market place. Also, the Wi-Fi has been embedded in the microcontroller; therefore, it can be monitored remotely. An analysis is required to examine the microcontroller's characterization, which is used as a load for the DC2509A and performance from the DC2509A energy harvesting demo board, noticing the power consumption by its load that connected to the board. The purpose of this study to analyze the power generated by the DC2509A energy harvesting demo board to activate NodeMCU ESP8266 in order to find out the operational time of DC2509A. Keywords: energy harvesting, DC2509A, Node MCU ESP8266, characteristic
PENGARUH PENURUNAN KADAR AIR MENGGUNAKAN OVEN ELEKTRIK TERHADAP KEKUATAN DIELEKTRIK VIRGIN COCONUT OIL (VCO) Dimas Hariyo Kuncoro; Mochammad Dhofir; Mahfudz Shidiq
Jurnal Mahasiswa TEUB Vol 9, No 1 (2021)
Publisher : Jurnal Mahasiswa TEUB

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Penggunaan minyak isolasi pada pada peralatan tegangan tinggi seperti transformator memiliki fungsi sebagai pemisah antar penghantar-penghantar bertegangan dan juga sebagai media pendingin. VCO dapat digunakan pada peralatan tegangan tinggi sebagai isolasi cair. Namun VCO masih memiliki kekuatan dielektrik yang rendah. Salah satu faktor penurunan kekuatan dielektrik adalah adanya uap air pada bahan isolasi. Kandungan kadar air pada VCO menyebabkan nilai konduktivitas menjadi meningkat dan tegangan tembus pada VCO menjadi menurun. Karena itu VCO perlu dipanaskan agar kadar airnya berkurang dengan menggunakan oven elektrik. Penelitian ini menggunakan metode pengujian kadar dengan oven elektrik untuk menurunkan kadar air VCO dan menggunakan metode pengujian tegangan tinggi AC untuk mengetahui nilai tegangan tembus.  Dari hasil pengujian kadar air VCO tanpa pemanasan oven elektrik didapatkan kadar air sebesar 1700,94 ppm dan tegangan tembus sebesar 15,43 kV. Nilai tersebut masih jauh dari standar yang ditetapkan oleh IEC 296 maupun SPLN 49-1. Nilai tegangan tembus yang harus dipenuhi oleh VCO jika digunakan sebagai isolasi cair berdasarkan IEC 296 berkisar 30 kV hingga 50 kV.  VCO dengan pemanasan variasi suhu 50°C, 60°C dan 70°C dan lama pemanasan 30 menit, 45 menit dan 60 menit mengakibatkan terjadinya penurunan kadar air serta meningkatnya tegangan tembus. Kekuatan dielektrik tertinggi VCO sebesar 35,71 kV diperoleh ketika dipanaskan dengan oven elektrik pada suhu 70°C selama 30 menit serta kandungan kadar air 853,12 ppm.  VCO yang telah dipanaskan dengan oven elektrik, masih belum memenuhi standar kadar air yang ditetapkan JIS (Japanese Industrial Standard) 2320 sebesar 50 ppm (part per million) namun terjadi peningkatan tegangan tembus sebesar 131% dibandingkan VCO tanpa melalui proses pemanasan. Kata kunci: Minyak Isolasi, VCO, Kadar Air, Tegangan Tembus, Kekuatan Dielektrik   ABSTRACT The use of insulating oil on high voltage machines like transformer used to separate between conductors and cooling methods.  VCO is used in high voltage machines as insulating oil.  However, VCO has a low the dieletric strength.  One of the main factors that caused the reduction of the dielectric strength is the existence of steam at isolator.  As water content on VCO decreases, conductivity increases and breakdown voltage on VCO decreases.  Because of that VCO needs to be heated to decrease the water content with electric oven. This study used the content testing method with an electric oven to reduce the air content of the VCO and used the AC high voltage test method to determine the breakdown voltage value.  From the results of testing the water content of VCO without heating the electric oven process, the water content was 1700.94 ppm and the breakdown voltage was 15.43 kV.  This value is still far from the standard set by IEC 296 and SPLN 49-1.  The breakdown voltage value that must be met by VCO if used as liquid insulation according to IEC 296 ranges from 30 kV to 50 kV.  VCO which goes through an electric oven heating process with temperature variations of 50°C, 60°C and 70oC and with a heating time of 30 minutes, 45 minutes and 60 minutes results in a decrease in water content and an increase in the breakdown voltage.  The highest dielectric strength of VCO of 35.71 kV was obtained when heated at 70°C for 30 minutes with the lowest moisture content of 853.12 ppm.  VCO that has been heated with an electric oven, still does not fulfill the water content standard set by JIS (Japanese Industrial Standard) 2320 of 50 ppm (parts per million) but there is an increase in the breakdown voltage of 131% compared to VCO without going through the heating process. Key word: Insulating Oil, VCO, Water Content, Breakdown Voltage, Dielectric Strength

Page 2 of 2 | Total Record : 18


Filter by Year

2021 2021


Filter By Issues
All Issue Vol. 14 No. 2 (2026) Vol. 14 No. 1 (2026) Vol. 13 No. 7 (2025) Vol. 13 No. 6 (2025) Vol. 13 No. 5 (2025) Vol. 13 No. 4 (2025) Vol. 13 No. 3 (2025) Vol. 13 No. 2 (2025) Vol. 13 No. 1 (2025) Vol. 12 No. 6 (2024) Vol. 12 No. 5 (2024) Vol. 12 No. 4 (2024) Vol. 12 No. 3 (2024) Vol. 12 No. 2 (2024) Vol. 12 No. 1 (2024) Vol. 11 No. 6 (2023) Vol. 11 No. 5 (2023) Vol. 11 No. 4 (2023) Vol. 11 No. 3 (2023) Vol. 11 No. 2 (2023) Vol. 11 No. 1 (2023) Vol. 10 No. 6 (2022) Vol. 10 No. 5 (2022) Vol. 10 No. 4 (2022) Vol. 10 No. 3 (2022) Vol. 10 No. 3 (2022): Vol. 10 No. 2 (2022) Vol 10, No 2 (2022) Vol 10, No 1 (2022) Vol 9, No 8 (2021) Vol 9, No 7 (2021) Vol 9, No 6 (2021) Vol 9, No 5 (2021) Vol 9, No 4 (2021) Vol 9, No 3 (2021) Vol 9, No 2 (2021) Vol 9, No 1 (2021) Vol 8, No 5 (2020) Vol 8, No 4 (2020) Vol 8, No 3 (2020) Vol 8, No 2 (2020) Vol 8, No 1 (2020) Vol 7, No 7 (2019) Vol 7, No 6 (2019) Vol 7, No 5 (2019) Vol 7, No 4 (2019) Vol 7, No 3 (2019) Vol 7, No 2 (2019) Vol 7, No 1 (2019) Vol 6, No 7 (2018) Vol 6, No 6 (2018) Vol 6, No 5 (2018) Vol 6, No 4 (2018) Vol 6, No 3 (2018) Vol 6, No 2 (2018) Vol 6, No 1 (2018) Vol 5, No 6 (2017) Vol 5, No 5 (2017) Vol 5, No 4 (2017) Vol 5, No 3 (2017) Vol 5, No 2 (2017) Vol 5, No 1 (2017) Vol 4, No 8 (2016) Vol 4, No 7 (2016) Vol 4, No 6 (2016) Vol 4, No 5 (2016) Vol 4, No 4 (2016) Vol 4, No 3 (2016) Vol 4, No 2 (2016) Vol 4, No 1 (2016) Vol 3, No 7 (2015) Vol 3, No 6 (2015) Vol 3, No 5 (2015) Vol 3, No 5 (2015) Vol 3, No 4 (2015) Vol 3, No 3 (2015) Vol 3, No 2 (2015) Vol 3, No 1 (2015) Vol 2, No 7 (2014) Vol 2, No 6 (2014) Vol 2, No 5 (2014) Vol 2, No 4 (2014) Vol 2, No 3 (2014) Vol 2, No 3 (2014) Vol 2, No 2 (2014) Vol 2, No 2 (2014) Vol 2, No 1 (2014) Vol 1, No 5 (2013) Vol 1, No 4 (2013) Vol 1, No 3 (2013) Vol 1, No 2 (2013) Vol 1, No 1 (2013) Vol 1, No 1 (2013) More Issue