Jurnal Ampere
ISSN : 24772755     EISSN : 26222981     DOI : http://dx.doi.org/10.31851/ampere
Jurnal Ampere, The aim of this journal is to publish articles to all aspects of the latest outstanding developments in the field of Electrical Engineering. Power Systems ·Generator ·Power Distribution ·Electrical Power Convertion ·Protection Systems ·Electrical Materials ·Newreble Energy Signal, System and Electronics ·Digital Signal Processing ·Robotic Systems ·Micro Electronics ·Embedded Systems Computer system ·Information Technology ·Communication Systems
Articles 291 Documents
RUGI-RUGI DAYA PADA TRANSFORMATOR U.019 PT PLN (PERSERO) WS2JB RAYON AMPERA AKIBAT KETIDAKSEIMBANGAN BEBAN Azis, Abdul; Nurdiana, Nita; Nisa, Ulfa Lathifatun
JURNAL AMPERE Vol 3, No 1 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (20.08 KB) | DOI: 10.31851/ampere.v3i1.2145

Abstract

Power losses in distribution transformers can cause neutral currents. Neutral currents in distribution transformers can be caused by load imbalances. This study investigates the load imbalance on the secondary side of the transformer U.019 PT. PLN (PERSERO) Palembang Ampera Rayon. Measurement results and calculations show that if a neutral current load is equalized and power losses due to load imbalance in the distribution transformer are reduced. Unbalanced expense loss due to the neutral current of Peak Expense of 41,5090A and the lowest Expense of 12,1244A so that the percentage of loss in Peak Load loss is 5,3443% and the lowest expense is 1,8562%, and due to the falling unbalanced load voltage is obtained Percentage of Peak Loads of 7.28365% and Lowest Load of 2.43736% of balanced load loss due to neutral currents at balanced load, At Peak Load of 4.9482% and afternoon of 1.7647% and due to balanced load voltage drop in Peak can be 4,94819% and the lowest load can be 1,76471%. The load equalization results in the average peak load that is 262.66667 A with the current load current is IR 262A, IS 263A and IT 263A and at the lowest load average current is 95.0000 A, with a perfect load current IR 94 A, IS 95 A and IT 95 A. Difference Between Unbalanced Charges due to neutral currents with a balanced load at peak loads of 3.961% and the lowest load of 915% while the difference in the voltage drop is unbalanced and balanced at peak load 2.33546% and the Lowest Load amounting to 0.67265% ABSTRAK Rugi-rugi daya pada transformator distribusi dapat menimbulkan arus netral. Arus netra lpad atransformator distribusi dapat disebabkan ketidakseimbangan beban. Penelitian ini menyelidiki ketidakseimbangan beban pada sisise kunder transformator U.019 PT. PLN  (PERSERO) Rayon Ampera Palembang. Hasil pengukuran dan perhitungan menunjukkan bahwaapa bila dilakukan pemerataan beban arus netral dan rugi – rugidayaakibatketidakseimbanganbebanpadatransformatordistribusiberkurang.rugi rugi beban ketidak seimbang akibat arus netral Beban Puncak sebesar 41,5090A dan Beban terendah sebesar  12,1244A sehingga persentase rugi rugi daya Beban Puncak sebesar  5,3443% dan beban Terendah 1,8562% ,dan akibat jatuh tegangan beban ketidak seimbang di peroleh persentase pada Beban Puncak  Sebesar 7,28365%  dan Beban Terendah 2,43736% rugi rugi beban seimbang akibat arus netral pada beban seimbang, Pada Beban Puncak sebesar  4,9482% dan siang 1,7647%  dan akibat jatuh tegangan beban seimbang  Benan Puncak  di dapat 4,94819% dan Beban Terendah di dapat  1,76471%. Hasil pemerataan beban di dapat arus rata rata Beban Puncak  yaitu 262,6667 A dengan arus beban perfasa yaitu IR  262A , IS 263A dan  IT  263A dan pada beban Terendah arus rata rata  yaitu 95,0000 A ,dengan arus beban perfasa yaitu IR 94 A , IS 95 A dan  IT 95 A. Selisih Antara Beban Tidak Seimbang akibat arus netral  dengan beban seimbang pada beban puncak sebesar 3,961% dan beban Terendah sebesar 915% sedangkan selisih pada jatuh tegangan tidak seimbang dan seimbang pada beban puncak 2,33546% dan Beban Terendah sebesar 0,67265% 
STUDI KEMAMPUAN PANEL LVMDP TERHADAP PEMBEBANAN Al Amin, M. Saleh
JURNAL AMPERE Vol 3, No 1 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (427.52 KB) | DOI: 10.31851/ampere.v3i1.2115

Abstract

ABSTRACT In today's highly competitive industry, manufacturing and production industries are required to always be ready and reliable in the availability of products offered to consumers. This is absolutely absolute because ultimately it involves consumer satisfaction as the final part of a business chain. One of the factors that plays an important role in the industrial world is the facilities and facilities, facilities and facilities including production machinery, buildings, materials, and other supporting facilities. In this case the production machine is a vital part in a work / manufacturing location, where the production machine generally uses an electric motor as a driver in operating it. One type of electric motor that is widely used is the type of commutator induction motor, because according to their needs, namely for high speed, such as drilling machines, planers, mixers, which are the driving force of workshop and production equipment, which are often used in frame making workshops, workshops lathe, and other workshop. On continuous operation, only a few seconds of operation will stop, the motor coil will heat up, which means expansion of the coil wire. This will result in changes in motor impedance, so that the motor rotation will also change. The provisional guess of the test is that there is a expansion of coil wire due to heating, which results in an increase in motor impedance, so that the motor rotation will decreaseABSTRAK Panel LVMDP merupakan peralatan listrik yang terdiri dari beberapa komponen listrik, yang berfungsi sebagai pembagi utama saluran distribusi tegangan rendah ke setiap saluran beban, sebagai pembatas daya utama, dan pengaman pada rangkaian utama sistem distribusi tegangan rendah. Komponen-komponen yang terdapat pada panel LVMDP ini antara lain, MCCB utama, MCCB salauran setiap beban atau cabang, Selector  Switch, Contactor, KWh meter, ACB, UVT, OVT, OCR, EFR, RPR, GFCI, RCD, TOR, Busbar tembaga, CT, Alat ukur arus, tegangan, frekwensi, Faktor kerja, Synkronous meter, Capacitor Bank, Pushbutton, Pilot Lamp, dan peralatan penunjang lainnya, seperti terminal, dan lainnya. Komponen utama yang sangat berperan dalam penyaluran daya suatu panel LVMDP dalam keadaan normal adalah MCCB, yang dapat memikul seluruh beban panel dalam keadaan steady state. MCCB ini akan ditunjang oleh komponen-komponen lainnya apabila terjadi gangguan, seperti bila terjadi hubung singkat, yang terjadi setelah MCCB. Bila terjadi gangguan sebelum MCCB, maka komponen yang akan bekerja adalah UVT atau OVT, dan seterusnya, sehingga bila terjadi gangguan maka MCCB akan di backup oleh komponen penunjang.  Tetapi bila terjadi kegagalan pada komponen penunjang, maka MCCB harus dapat berfungsi sebagai proteksi terhadap panel LVMDP secara keseluruhan, baik dari gangguan beban lebih, maupun gangguan hubung singkat, tetapi MCCB tidak dapat menanggulangi gangguan di luar kemampuannya. Dengan demikian kemampuan MCCB untuk melindungi panel LVMDP dari gangguan beban lebih dan hubung singkat, tertera pada nameplate MCCB tersebut.
ANALISA SISTEM PENTANAHAN TRANSFORMATOR Febrianti, Irine Kartika
JURNAL AMPERE Vol 3, No 1 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31851/ampere.v3i1.2146

Abstract

Grounding is connecting a circuit or equipment to the earth. Poor earthing systems can lead to decreased quality of electric power. Studies of land is often underestimated, but a good grounding is very important.While doing research in substations gutter oil, load imbalance on a substation Gutter oil, causing the flow of each phase at # 3 60MVA power transformer 150/20 KVPT. PLN (Persero) substation Talang Kelapa Banyuasin become unbalanced that IR = 954.37 A, IS = 968.32, IT = 950.24 A. The amount of load imbalance (%) between each phase at # 3 60MVA power transformer 150/20 KV is 0.7412%,This is because the use of an uneven load. As a result of load imbalance between each phase at # 3 60MVA power transformer 150/20 kV, the current will flow in the neutral transformer IN = 16,40574Ð-72,59°.power loss due to the neutral current is 0.7073 W. neutral point voltage to ground -22.32 V. neutral current flowing to ground is 23.1768 A. power loss due to neutral current flowing to ground is 1 , 4116 W. current flowing to the ground from the second transformer is 22.23699 Ampere. Prisoners to the substation earthing gutter oil is R10,0692  Ω and R2 0,1856 Ω, while the resistance value of the grounding in a way parallel 1Ω, so either one very effective way to lose custody of land is to deepen the grounding electrodePentanahan adalah melakukan koneksi sirkuit atau peralatan ke bumi. Sistem pentanahan yang kurang baik dapat menyebabkan penurunan kualitas tenaga listrik. Ilmu pertanahan sering kali dianggap remeh, padahal pentanahan yang baik sangatlah penting. ketidakseimbangan beban menyebabkan arus tiap fasa pada Transformator daya #3 60MVA 150/20 KV menjadi tidak seimbang yaitu IR = 954,37 A, IS = 968,32, IT = 950,24 A. Besarnya ketidak seimbangan beban (%) antara tiap-tiap fasa pada Transformator daya #3 60MVA 150/20 KV adalah 0,7412 %, hal ini disebabkan karena penggunaan beban yang tidak merata. Sebagai akibat dari ketidakseimbangan beban antara tiap-tiap fasa pada Transformator daya #3 60MVA 150/20 KV maka akan mengalir arus di netral transformator IN = 16,40574Ð-72,59°. rugi-rugi daya akibat adanya arus netral adalah 0,7073 W. tegangan titik netral terhadap tanah -22,32 V. arus netral yang mengalir ke tanah adalah 23,1768 A. rugi-rugi daya akibat arus netral yang mengalir ke tanah adalah 1,4116 W.Arus yang mengalir ketanah dari kedua transformator adalah 22,23699 Ampere.Tahanan pentanahan adalah R10,0692  Ω dan R2 0,1856 Ω, sedangkan nilai tahanan pentanahan dengan cara parallel sebesar 1Ω, jadi salah Satu cara yang sangat efektif untuk menurunkan tahanan tanah adalah dengan memperdalam elektroda pentanahan.
PENGUKURAN GROUNDING SDP PANEL DISTRIBUSI INSTALASI REKAM MEDIS RSUP DR. MOHAMMAD HOESIN PALEMBANG Putra, Dian Eka; Udi, Jaka
JURNAL AMPERE Vol 3, No 1 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (557.699 KB) | DOI: 10.31851/ampere.v3i1.2157

Abstract

The use of electrical energy is directly proportional to the reliability of electrical installations used in the building of General Hospital DR. Mohammad Hoesin Palembang, in his activities using sophisticated (complicated) equipment. One of them is in the electrical installation, namely the installation of grounding or earthing. Grounding resistance value according to General Electrical Installation (PUIL) 2000 does not exceed 5Ω, so that based on the calculation with the variables, the resistance value is 0.67 Ω, so there is a need for a comparison of the value of the resitance from the calculation with the value of the resitance directly to grounding, grounding system in the morning and evening in the electrical panel of General Hospital medical record installation Dr. Mohammad Hoesin Palembang. From the results of direct measurements in the morning between 7:30 a.m. and 10:30 p.m, resistance resistance values were obtained with an average of 0.11Ω. Based on measurements of ground resistance resistance in the afternoon at 3:00 p.m. to 5:00 p.m., resistance resistance values were obtained with an average of 0.07Ω. ABSTRAK  Penggunaan Energi Listrik berbanding lurus dengan keandalan instalasi listrik yang digunakan pada gedung instalasi rekam medis RSUP DR. Mohammad Hoesin Palembang, didalam aktivitasnya menggunakan peralatan canggih (complicated). Salah satunya pada instalasi listrik yaitu pada instalasi grounding atau pentanahan. Nilai resitansi atau tahanan pentanahan menurut Persyratan Umum Instalasi Listrik (PUIL) 2000 tidak melebihi 5Ω, sehingga Berdasarkan perhitungan dengan variabel-variabel didapat nilai resistansi yaitu 0,67 Ω, sehingga perlunya ada perbandingan nilai resitansi dari hasil perhitungan dengan nilai resitansi hasil pengukuran langsung pada sistem grounding tahanan pentanahan pada waktu pagi dan sore hari di panel listrik instalasi rekam medis RSUP Dr. Mohammad Hoesin Palembang. Dari hasil pengukuran langsung pada pagi hari antara pukul 07.30 sampai 10.30 Wib didapatkan nilai tahanan resistansi dengan rata-rata 0.11Ω, Berdasarkan pengukuran resistansi tahanan pentanahan pada waktu sore hari pada pukul 15.00 sampai 17.00 Wib didapatkan nilai tahanan resistansi dengan rata-rata 0.07Ω.
KONVERSI LAMPU TL KE LAMPU LED ( STUDI KASUS : JAKABARING SHOOTING RANGE JAKABARING SPORT CITY PALEMBANG ) Nurdiana, Nita; Amin, Saleh Al; Thohari, Abdurrahman
JURNAL AMPERE Vol 3, No 2 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (759.417 KB) | DOI: 10.31851/ampere.v3i2.2394

Abstract

Asian Games 2018 which will be held in Jakarta and Palembang, Jakabaring Shooting Range Palembang to renovate the building to support the success of Asian Games 2018 at shooting sport. This renovation also replace or convert lamps that previously used TL 2 x 36 Watt lamps to use 40 Watt LED flat lights. In this case the aim to know this comparison is by calculating theoretically strong illumination, the power generated as well as the cost incurred. From the comparison results obtained the comparison terotirs how the better and see the two lights are whether the standard qualified lighting in the arena shooting space That LED lights have a strong light almost the same as the TL lamps but in terms of electric power used LED lights generate more electrical power small with a smaller electric power is obtained electricity tariffs are also cheap, so LEDs can be very energy-efficient lamps and save money.Dengan adanya momentum pergelaran kompetisi olahraga tingkat Asia yaitu Asian Games 2018 yang akan diadakan di Jakarta dan Palembang, Jakabaring Shooting Range Palembang melakukan renovasi pada gedungnya untuk menunjang suksesnya Asian Games 2018 pada cabang olahraga menembak. Renovasi ini juga menganti atau mengkonversikan lampu yang sebelumnya menggunakan lampu TL 2 x 36 Watt menjadi menggunakan lampu flat LED 40 Watt. Dalam hal ini bertujuan untuk mengetahui perbandingan ini adalah dengan menghitung secara teoritis kuat penerangan, daya yang dihasilkan serta biaya yang dikeluarkan. Dari hasil perbandingan didapatkan perbandingan secara terotirs bagaimana yang lebih baiknya dan melihat kedua lampu tersebut apakah memenuhi syarat standar penerangan pada ruang arena menembak Bahwa lampu LED memiliki kuat penerangan hampir sama dengan lampu TL tetapi dari segi daya listrik yang digunakan lampu LED menghasilkan daya listrik yang lebih kecil dengan daya listrik yang lebih kecil ini didapat tarif listrik yang murah pula, dengan begitu LED sangat bisa menjadi lampu yang hemat energi serta hemat pengeluaran uang.
PENGARUH JARAK ANTAR SUB KONDUKTOR BERKAS REAKTANSI INDUKTIF SALURAN TERHADAP TRANSMISI 150 KV DARI GARDU INDUK KERAMASAN KE GARDU INDUK MARIANA Nurdin, Alimin; Azis, Abdul
JURNAL AMPERE Vol 3, No 2 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (968.723 KB) | DOI: 10.31851/ampere.v3i2.2395

Abstract

Electricity is a source of energy that is very much needed by society and electricity is one of the most important needs to support human life today in meeting daily needs, both in the household and in business. The generated electricity is then channeled through the transmission line. In the distribution of electric power, there will be a channeling power losses which are proportional to the length of the channel. The use of a higher voltage level is the solution to these problems, but if the voltage is increased continuously there will be a corona and to reduce the environmental impact of the corona can use a file conductor. Increasing the amount of conductive wire in a beam reduces the corona effect and reduces reactance, reducing reactance due to an increase in GMR from the conductor. Elevation of the voltage on the electric power transmission line can reduce power losses, but the transmission voltage increase can cause corona in the transmission wire. This corona causes power losses and interference with radio communications. One way to reduce the corona effect is to use a condenser file on the transmission line. Besides reducing the corona effect, the beam conductor can also reduce the channel's inductive reactance. From the results of the study, the results show that the distance between the file sub conductors affects the size of the GMR of the file conductor, where the distance between the file sub conductors is greater, the GMR of the conductor will increase. With the increasing size of GMR conductor, the inductive reactance on the transmission line will be even greater. With the increasing conductivity of the beam conductor reactance, the reactive power losses on the transmission line will be even greater. Listrik adalah sumber energi yang sangat dibutuhkan oleh masyarakat dan listrik merupakan salah satu kebutuhan yang paling penting untuk menunjang kehidupan manusia saat ini dalam memenuhi kebutuhan sehari-hari, baik dalam rumah tangga maupun dalam bisnis. Untuk memenuhi kebutuhan tenaga listrik tersebut, maka pemerintah membangun pusat-pusat pembangkit tenaga listrik. Dalam penyaluran daya listrik akan terjadi rugi-rugi daya penyaluran yang besarnya sebanding dengan panjang saluran. Penggunaan tingkat tegangan yang lebih tinggi merupakan solusi dari permasalahan tersebut, tetapi jika tegangan ditingkatkan terus menerus akan terjadi korona dan untuk mengurangi dampak lingkungan dari korona tersebut dapat menggunakan konduktor berkas. Peningkatan jumlah kawat penghantar dalam suatu berkas mengurangi efek korona dan mengurangi reaktansi, pengurangan reaktansi disebabkan oleh kenaikan GMR dari konduktor. Peninggian tegangan pada saluran transmisi daya listrik dapat mengurangi rugi-rugi daya, tetapi peninggian tegangan transmisi dapat menimbulkan korona pada kawat transmisi. Korona ini menimbulkan rugi-rugi daya dan gangguan terhadap komunikasi radio. Salah satu cara untuk mengurangi efek korona yang dilakukan adalah dengan menggunakan kondukor berkas pada saluran transmisi. Di samping mengurangi efek korona, penghantar berkas dapat juga mengurangi reaktansi induktif saluran. Dari hasil penelitian diperoleh hasil bahwa jarak antar sub konduktor berkas mempengaruhi besarnya GMR konduktor berkas, dimana apabila jarak antar sub konduktor berkas semakin besar maka GMR konduktor berkas akan semakin besar. Dengan semakin besarnya GMR konduktor berkas maka reaktansi induktif pada saluran transmisi akan semakin besar. Dengan semakin besarnya reaktansi induktif konduktor berkas maka rugi-rugi daya reaktif pada saluran transmisi akan semakin besar.
PENGUJIAN EFFISIENSI TRANSFORMATOR INTI FERRIT DI LABORATORIUM TEKNIK ELEKTRO UNIVERSITAS PGRI PALEMBANG Emidiana, Emidiana; Saputra, Febrianto
JURNAL AMPERE Vol 3, No 2 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (669.864 KB) | DOI: 10.31851/ampere.v3i2.2396

Abstract

The transformer is a static electromagnetic device that functions to transfer the electrical power of an electrical circuit to another electrical circuit with the principle of electromagnetic induction. The transformer is widely used, both in the field of electricity and electronics. In this study we will discuss the efficiency of ferrite core transformers compared to iron core transformers, if used in electric power. This research was located at the Electrical Engineering laboratory Universitas PGRI Palembang. From the measurement results concluded that the ferrite core transformer efficiency is lower when compared to iron core transformers and not feasible if used in electric power. Transformator merupakan alat listrik elektromagnetik statis yang berfungsi memindahkan dan mengubah daya listrik dari suatu rangkaian listrik ke rangkaian listrik lainnya dengan prinsip induksi elektromagnetis. Transformator digunakan secara luas, baik dibidang tenaga listrik maupun elektronika, dengan bermacam-macam klasifikasi, salah satunya dari sisi inti transformatornya. Pada penelitian ini akan dibahas tentang effisiensi transformator inti ferrit yang dibandingkan dengan transformator inti besi, jika digunakan pada tenaga listrik. Penelitian ini yang dilakukan di laboratorium Teknik Elektro Universitas PGRI Palembang. Dari hasil pengukuran didapat bahwa effisiensi transformator inti ferrit lebih rendah jika dibandingkan dengan transformator inti besi dan tidak layak jika digunakan pada tenaga listrik. 
APLIKASI MATRIK KOOKURANSI TINGKAT KEABUAN UNTUK ANALISA CITRA IKAN TENGGIRI Jumnahdi, Muhammad; Anisah, Masayu; Rasyad, Sabilal
JURNAL AMPERE Vol 3, No 1 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (391.936 KB) | DOI: 10.31851/ampere.v3i1.2118

Abstract

Mackerel fish (Cybium commersoni) which is a lot of fish found in the waters of Indonesia with high economic value. This study aims to analyze the image of mackerel fish with 25 fish tail that has an average length of 40cm with weight of 250-300 gram taken in fresh condition from Fish Auction Place located in Kurau village and Pantairebo village of Bangka Island. The image of the fish is taken by using 12Mpiksel digital camera. Image retrieval period is 0 to 6 hours, 6 hours and 6 hours. The image is passed to the RGB filter, which is then extracted using GLCM resulting in a mean of Entropy 3.2039 for fresh fish while for fresh fish 3.5714; Energy 0,0531 for fresh fish while for fresh fish 0,0053; contrast produced 63,6157 for fresh fish while fish not fresh equal to 33,8951; The correlation of 0.5673 for fresh fish and 0.7822 for fish is not fresh homogeneity 0.2357 for fresh fish and 0.1345 for non fresh fish.ABSTRAK Ikan tenggiri (Cybium commersoni) yang merupakan ikan yang banyak ditemukan diperairan Indonesia dengan nilai ekonomis yang tinggi. Penelitian ini bertujuan untuk menganalisa citra Citra ikan tenggiri dengan  sampel ikan 25 ekor yang memiliki panjang rata-rata 40cm dengan berat 250-300 gram diambil dalam kondisi segar dari Tempat Pelelangan Ikan yang berada di desa Kurau dan desa Pantairebo Pulau Bangka. Citra ikan diambil dengan menggunakan camera digital 12Mpiksel. Jangka waktu pengambilan Citra 0 sampai dengan 6 jam pertama, 6 jam kedua dan 6 jam ketiga. Citra dilewatkan pada filter RGB, yang kemudian diekstraksi dengan menggunakan GLCM yang menghasilkan rerata Entropi 3.2039 untuk ikan segar sedangkan untuk ikan tidak segar 3,5714; Energi 0,0531 untuk ikan segar sedangkan untuk ikan tidak segar sebesar 0,0053; kontras dihasilkan 63,6157 untuk ikan segar sedangkan ikan tidak segar sebesar 33,8951; Korelasi 0,5673 untuk ikan segar dan 0,7822 untuk ikan tidak segar homogenitas 0,2357 untuk ikan segar dan 0,1345 untuk ikan tidak segar
EVALUASI KETERSEDIAAN DAYA PADA PT. PLN (PERSERO) GARDU INDUK BUNGARAN PALEMBANG Azis, Abdul; Febrianti, Irine Kartika
JURNAL AMPERE Vol 3, No 2 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (699.748 KB) | DOI: 10.31851/ampere.v3i2.2397

Abstract

Power losses are the loss of electrical power in the network and the load where the lost power is not used by the load, so the power available on the network will be reduced. Power losses in the distribution network are caused by the presence of prisoners in the carrier. The lost power can be in the form of heat energy generated on the channel, and unused heat energy is called active power losses. Power losses in each channel are very important to take into account because power losses in the network can cause a reduction in electrical energy after arriving at the load. Power requirements that must be supplied by the source to the load depend on the absorption of power by the load and power losses on the network. Large capacity of power requirements is influenced by the amount of power losses, so it can be said that the capacity of power needs is the amount of absorption of power by the load and power losses on the network. One of the substations in the city of Palembang is the Bungaran Substation which has the function of delivering electrical energy to consumers through a medium voltage distribution system. To serve consumers electrical energy needs, currently the Bungaran Palembang Substation has a Transformer 1, 30 MVA 70/20 kV which has a load of four feeders, namely: Akasia Feeder, Sungkai Feeder, Tembesu Feeder, and Cendana Feeder. The results showed that Transformer 1 had an installed power capacity of 30 MVA or 255,000,000 Watts. While the capacity of the total power requirements of the four feeders is 18,786,167.4264 W. So the availability of transformer 1 power is still sufficient to serve the load of four feeders, because only 7.3671% of the installed power capacity is absorbed by the load. Rugi-rugi daya adalah kehilangan daya listrik di jaringan dan beban dimana daya yang hilang tersebut tidak terpakai oleh beban, sehingga daya yang tersedia di jaringan akan berkurang. Rugi-rugi daya pada jaringan distribusi disebabkan oleh adanya tahanan pada penghantar. Daya yang hilang dapat berupa energi panas yang ditimbulkan pada saluran, dan energi panas yang tidak terpakai disebut sebagai rugi-rugi daya aktif. Rugi-rugi daya disetiap saluran sangatlah penting untuk diperhitungkan karena rugi-rugi daya di jaringan dapat menyebabkan berkurangnya energi listrik setelah sampai di beban. Kebutuhan daya yang harus disuplai oleh sumber ke beban tergantung pada penyerapan daya oleh beban dan rugi-rugi daya di jaringan. Besar kapasitas kebutuhan daya dipengaruhi oleh besarnya rugi-rugi daya, sehingga dapat dikatakan bahwa kapasitas kebutuhan daya merupakan jumlah penyerapan daya oleh beban dan rugi-rugi daya di jaringan. Salah satu gardu induk di Kota Palembang adalah Gardu Induk Bungaran yang mempunyai fungsi menyalurkan energi listrik ke konsumen melalui sistem distribusi tegangan menengah. Untuk melayani kebutuhan energi listrik konsumen, saat ini Gardu Induk Bungaran Palembang mempunyai Transformator 1, 30 MVA 70/20 kV yang mempunyai beban empat buah penyulang, yaitu: Penyulang Akasia, Penyulang Sungkai, Penyulang Tembesu, dan Penyulang Cendana. Dari hasil penelitian diperoleh hasil bahwa Transformator 1 mempunyai kapasitas daya terpasang sebesar 30 MVA atau 255.000.000 Watt. Sedangkan kapasitas kebutuhan daya total dari empat penyulang adalah 18.786.167,4264 W. Jadi ketersediaan daya Transformator 1 masih mencukupi untuk melayani beban dari empat penyulang, karena hanya 7,3671 % dari kapasitas daya terpasang daya yang diserap oleh beban.
KENDALI SUHU AIR DENGAN SENSOR TERMOKOPEL TIPE-K PADA SIMULATOR SISTEM PENGISIAN BOTOL OTOMATIS Sari, Dewi Permata; Rasyad, Sabilal; Amperawan, Amperawan; Muslimin, Selamat
JURNAL AMPERE Vol 3, No 2 (2018): JURNAL AMPERE
Publisher : Universitas PGRI Palembang

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (710.382 KB) | DOI: 10.31851/ampere.v3i2.2393

Abstract

This observation discusses about water temperature control by using thermocouple K-type sensor in an automatic bottle filling system simulator. This control system is purposed to keep the bottle unexpand in the effect of high temperature water. In this observation, we obtained that the bottle will defend or unexpand if it is filled with water in a temperature of ±65°c. This temperature will be used as reference in a water temperature control by using thermocouple sensor. The control system works by monitoring the heater activites in order not to heat the water more than the deterimined setpoint temperature, which is 60°c. In the control process, a thermocouple sensor is supported by PLC Schneider Modicon TM221M16R. The communication process between the thermocouple sensor and PLC utilizes analog input in PLC device. Generated voltage by a thermocouple in the effect of temperature difference between hot junction and cold junction is read by PLC. Generated voltage in the effect of these two points difference is very small, about 40μV/°c. Therefore, IC op amp LM 358 is used as a voltage amplifier. The output of LM 358 is used as PLC analog input to control the water temperature.Abstrak— Pada penelitian ini dibahas mengenai kendali suhu air dengan sensor termokopel tipe-K pada simulator system pengisian botol otomatis. Pengontrolan ini ditujukan untuk menjaga agar botol yang digunakan tidak mengalami pemuaian akibat terisi oleh air dengan suhu tinggi. Dari peneltian didapatkan bahwa botol yang digunakan dalam system ini dapat bertahan atau tidak mengalami pemuaian jika diisi oleh air dengan suhu ± 65oC. Suhu inilah yang kemudian dijadikan sebagai referensi dalam kendali suhu air oleh sensor termokopel. Kendali suhu ini dilakukan dengan cara memantau aktivitas heater agar tidak memanaskan air melebihi suhu setpoint yang ditentukan yaitu 60oC. Pada proses kendalinya, sensor termokopel dibantu oleh PLC Schneider Modicon TM221M16R. Proses komunikasi antara sensor termokopel dan PLC memanfaatkan analog input yang tersedia diperangkat PLC. Adapun yang dibaca oleh PLC adalah tegangan yang dihasilkan oleh termokopel akibat perbedaan suhu antara hot junction dan cold junction. Tegangan yang dihasilkan oleh perbedaan kedua titik ini sangat kecil, berkisar antara 40μV/oC. Oleh karena itu digunakanlah IC op amp LM 358 sebagai penguat tegangan. Keluaran dari LM 358 inilah yang dijadikan sebagai input analog PLC untuk mengontrol suhu air.

Page 4 of 30 | Total Record : 291