cover
Contact Name
Syafii
Contact Email
jnte@ft.unand.ac.id
Phone
-
Journal Mail Official
Syafii@ft.unand.ac.id
Editorial Address
-
Location
Kota padang,
Sumatera barat
INDONESIA
JURNAL NASIONAL TEKNIK ELEKTRO
Published by Universitas Andalas
ISSN : 23022949     EISSN : 24077267     DOI : -
Core Subject : Engineering,
Jurnal Nasional Teknik Elektro (JNTE) adalah jurnal ilmiah peer-reviewed yang diterbitkan oleh Jurusan Teknik Elektro Universitas Andalas dengan versi cetak (p-ISSN:2302-2949) dan versi elektronik (e-ISSN:2407-7267). JNTE terbit dua kali dalam setahun untuk naskah hasil/bagian penelitian yang berkaitan dengan elektrik, elektronik, telekomunikasi dan informatika.
Arjuna Subject : -
Articles 610 Documents
Analisis Performansi Agregasi Link dengan Lacp pada SDN menggunakan RYU sebagai Controller Rohmat Tulloh
JURNAL NASIONAL TEKNIK ELEKTRO Vol 6, No 3: November 2017
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (526.375 KB) | DOI: 10.25077/jnte.v6n3.444.2017

Abstract

As time goes by, the world of communication has flourished quickly, especially in network. One of the network technologies by now called SDN (Software Defined Network), is a new paradigm in network technology that is able to virtualize network device by taking the function of control plane, that is usually taken by controller, and separate between control plane and data plane into a network device. Besides the coming of that new paradigm, the need of bandwidth consumption on data communication by this time has increased. Link aggregation is a method that combines several physical links into a logical link in the form of multiplying the bandwidth capacity. Link aggregation can be implemented in SDN network, that makes bandwidth consumption in network has good effect on service quality. In this research, the writer will show the comparison analysis between link aggregation and not using link aggregation in SDN network. This comparison analysis is done by analyzing some parameters, like throughput, packetloss, jitter and fault tolerance from the service in network, called video streaming.Keywords : SDN, Link aggregation, LACP, Redundansi, Bandwith.AbstrakDunia telekomunikasi saat ini berkembang dengan sangat pesat terutama dalam dunia jaringan. Salah satu teknologi jaringan masa kini adalah SDN (Software Defined Network) yaitu sebuah paradigma baru dalam teknologi jaringan yang dapat memvirtualisasi perangkat jaringan dengan mengambil fungsi control plane oleh controller dan memisahkan antara control plane dengan data plane dalam sebuah perangkat jaringan. Selain adanya paradigma baru tersebut, kebutuhan akan konsumsi bandwidth dalam komunikasi data saat ini juga meningkat. Link aggregation merupakan metode penggabungan link fisik menjadi satu link logis guna meningkatkan kapasitas bandwidth. Link aggregation dapat di implementasikan dalam jaringan SDN, hal ini membuat konsumsi sejumlah bandwidth pada jaringan berdampak baik terhadap kualitas layanan pada jaringan. Dalam penelitian ini, ditunjukkan analisis perbandingan terhadap jaringan SDN yang menggunakan metode link aggregation dengan jaringan SDN yang tanpa metode link aggregation. Analisis ini memperhatikan hasil pengukuran throughput, packet loss, jitter dan fault tolerant dari layanan video streaming pada jaringan.Kata Kunci : SDN, Link aggregation, LACP, Redundansi, Bandwith.
Perancangan Sistem Navigasi Robot Kapal Katamaran untuk Menghindari Rintangan Menggunakan Logika Fuzzy Rossi Passarella; Kemahyanto Exaudi; Sayyidatina Fatimah
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (779.814 KB) | DOI: 10.25077/jnte.v7n1.446.2018

Abstract

The robotic ship Katamaran is a robotic ship which has two extra hulls at both side. The existence of the hulls aims to keep the ship balance. The navigation of the robot or known as maneuver is set by the movement towards rudder which is installed at stern of ship. To do this Fuzzy Sugeno Logic is applied. The input of this fuzzy logic is obtained by camera which is placed at the prow. The input is an image video, the image then separated out three areas by using image processing which is being formed into left area, middle area, and right area. As the result of fuzzy calculation is the angle which is sent to the servo motors to move the rudder.  The maneuver of the robotic ship katamaran, has a good level.Keywords : Fuzzy Logic Sugeno, robotic ship Katamaran, Rudder, navigation systemAbstrakRobot kapal katamaran adalah sebuah kapal robot yang memiliki 2 buah lambung tambahan disisi kanan dan kiri yang berfungsi untuk menjaga kestabilan robot kapal. Pada penelitian ini dilakukan perancangan sistem navigasi pergerakan atau manuver robot kapal yang ditentukan oleh pergerakan rudder yang berada  di buritan kapal  dan dikendalikan secara otomatis mengadopsi teknik logika fuzzy Sugeno. Input logika fuzzy  ini didapat dari kamera yang terletak pada haluan robot kapal. Input ini dibagi menjadi 3 menggunakan proses pengolahan citra berupa daerah kiri, tengah dan kanan. Hasil dari  perhitungan fuzzy berupa nilai sudut yang dikirimkan ke motor servo untuk menggerakkan rudder. Pergerakan kapal katamaran menjadi baik.Kata Kunci : Fuzzy Logic Sugeno, , Robot Kapal Katamaran, Rudder, Sistem Navigasi
Analisa Perbandingan Tahanan Pembumian Peralatan Elektroda Pasak pada Gedung Laboratorium Teknik Universitas Borneo Tarakan Achmad Budiman
JURNAL NASIONAL TEKNIK ELEKTRO Vol 6, No 3: November 2017
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (647.314 KB) | DOI: 10.25077/jnte.v6n3.454.2017

Abstract

Earthing systems are less well able to cause damage to electrical equipment. The risks are more current can not be optimally channeled back to earth. The smaller the resistance value, The better the earthing system. In certain soil conditions, grounding resistance value is also influenced by the depth of planting electrodes. The measurement results one ground rod resistance value with each length of 1.5 m and 2 m, diameter 0.045 m, respectively depth of 3 m and 3.25 m in Building Engineering Laboratory of the University of Borneo Tarakan successively obtained values of R (earthing) amounted to 12.76 Ω and 12 Ω while the calculation, the value of R (earthing) of 12.85 and 12.10 Ω Ω with the average value of muddy clay resistivity (ρ) of 38.58 Ω-m and 38.84 Ω-m. The installation of a ground rod 1,5m  of minimum 3 pieces in parallel has an R (earthing) value of 4.28 Ω complied with General Term Electrical Installation (PUIL 2000) ≤ 5 Ω and minimum installation distance between electrodes of 2 (two) times in length.Keywords : single rod electrodes, resistivity, earthing resistance.Abstrak - Sistem pembumian yang kurang baik dapat menyebabkan kerusakan pada peralatan listrik. Resiko yang ditimbulkan adalah arus lebih tidak dapat disalurkan secara maksimal kembali ke bumi. Semakin kecil nilai tahanan pembumian maka semakin baik sistem pembumiannya. Pada kondisi tanah tertentu, nilai tahanan pembumian juga dipengaruhi oleh kedalaman penanaman elektroda.  Hasil pengukuran nilai tahanan pembumian elektroda pasak tunggal dengan panjang masing-masing 1,5 m dan 2 m, diameter 0,045 m, masing-masing kedalaman 3 m dan 3,25 m pada Gedung Laboratorium Teknik Universitas Borneo Tarakan berturut-turut diperoleh nilai R(pembumian) sebesar 12,76 Ω dan 12 Ω sedangkan hasil perhitungan diperoleh nilai R(pembumian) sebesar 12,85 Ω dan 12,10 Ω dengan nilai rata-rata tahanan jenis tanah liat berlumpur (
Analisa Operasi Ekonomis Pembangkit Termal untuk Melayani Beban Puncak Sistem Kelistrikan Sumbar Syafii Syafii; Kartika Ika Putri
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (782.557 KB) | DOI: 10.25077/jnte.v7n1.458.2018

Abstract

The economical operation of electric power systems is an important aspect in energy system management. The research aim is analyzing the economical operation of thermal generators by performing calculations to obtain optimal power and minimum generation costs, using the lamda iteration method. The case study of the operation of the plant in serving the peak load is taken on the West Sumatera electrical system with the assumption that the thermal generator units used are the PLTD, PLTG Pauh Limo, and PLTU Ombilin power plant. The power demand (PD) to be serviced by the thermal generator is 76.8 MW taken from 15% of maximum load duration curve 512 MW. The distribution of load demand for each thermal generating unit obtained through the economic dispatch calculation. The resulted of economical operation of the thermal generator P1 = 1,25 MW, P2 = 15,867 MW, and P3 = 59,683 MW with total generation cost 57,295,977.57 IDR/h. The calculation and comparison with other configuration scheduling results showed that by using economic dispatch method in power generation scheduling, has obtained efficient generation configuration with minimum operating cost to serve the peak load. Thus, the generation cost can be saved as the generation capacity can be optimized or operated in accordance with the calculation of economic operation.Keywords : Thermal Power Plant, Economic Dispatch, Lamda Iteration MethodAbstrakOperasi ekonomis sistem tenaga listrik merupakan aspek penting dalam manajemen sistem energi. Penelitian ini bertujuan melakukan analisa operasi ekonomis pembangkit termal dengan melakukan perhitungan untuk mendapatkan daya yang optimal serta biaya pembangkitan minimum, dengan  menggunakan metode iterasi lamda. Studi kasus operasi pembangkit dalam melayani beban puncak diambil pada sistem kelistrikan Sumbar dengan asumsi unit pembangkit termal yang digunakan adalah PLTD, PLTG Pauh Limo, dan PLTU Ombilin. Besar daya beban (PD) yang akan dilayani oleh pembangkit termal tersebut diambil 15 % dari kurva lama beban harian maksimum 512 MW yaitu 76,8 MW. Pembagian pembebanan untuk masing-masing unit pembangkit termal diperoleh melalui perhitungan economic dispatch. Hasil perhitungan operasi ekonomis untuk masing-masing pembangkit termal tersebut adalah P1 = 1,25 MW, P2 = 15,867 MW, dan P3 = 59,683 MW dengan total biaya pembangkitan Rp 57.295.977,57 per jam. Hasil perhitungan dan perbandingan dengan konfigurasi penjadwalan lainnya memperlihatkan bahwa dengan menggunakan perhitungan operasi ekonomis dalam penjadwalan pembangkit, telah diperoleh konfigurasi pembangkitan yang efisien dengan biaya operasi minimum untuk melayani beban puncak.  Dengan demikian biaya pembangkitan dapat dihemat sekirannya kapasitas pembangkitan dapat dioptimalkan atau dioperasikan sesuai dengan hasil perhitungan operasi ekonomis.Kata Kunci :  Pembangkit Termal, Economic Dispatch, Metode Iterasi Lamda
Analisis Aliran Daya Berbasis Injeksi Arus dalam Bentuk Vektor Ahmad Wira Satriawan; Lukmanul Hakim; Khairudin Khairudin
JURNAL NASIONAL TEKNIK ELEKTRO Vol 6, No 3: November 2017
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (505.613 KB) | DOI: 10.25077/jnte.v6n3.460.2017

Abstract

This paper discusses two different voltage representation models (polar and rectangular coordinates) of power flow analysis based on current injection method in vector form. This thesis conducted to obtained power flow analysis method with a faster and more accurate computation, and less iteration number. Newton-Raphson iteration method was adopted in this work and an in-house software was developed using python programming language and its vector operation-supported libraries. Analysis on convergence characteristics of the two voltage representations was carried out to the IEEE 14-bus test system. Result in this paper reveals that the full rectangular representation is more superior than the polar form for current injection method power flow in this particular case.Keywords : power flow, mismatch current injection, vector form, polar form, rectangular formAbstrakTulisan ini memaparkan hasil penelitian yang telah dilakukan untuk membandingkan metode analisis aliran daya berbasis injeksi arus dalam bentuk vektor dengan format polar dan rektangular. Penelitian ini dilakukan untuk memperoleh metode analisa aliran daya dengan perhitungan yang lebih cepat dan akurat, serta iterasi yang lebih sedikit. Metode iterasi Newton Raphson diadopsi dalam  penelitian ini dan bahasa pemrograman Python serta library komputasinya digunakan. Analisis terhadap karakteristik konvergensi dari kedua format dilakukan pada IEEE 14-bus Test System. Dari penelitian ini diperoleh hasil bahwa format rektangular lebih  unggul dibandingkan format polar untuk kasus yang diteliti.Kata kunci : aliran daya, mismatch injeksi arus, bentuk vektor, format polar, format rektangular
Studi Penempatan dan Kapasitas Pembangkit Tersebar terhadap Profil Tegangan dan Rugi Saluran pada Saluran Marapalam Syukri Yunus; Imbang Ismail
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (858.867 KB) | DOI: 10.25077/jnte.v7n1.462.2018

Abstract

This study aims to reduce the power loss and increase the voltage profile based on optimal placement and DG capacity on feeder Marapalam. The applied methods are the Sensitivity analysis method with Loss Sensitivity Factor (LSF) and Voltage Sensitivity Index (VSI). The results of both methods are compared with trial and error method. DG can reduce power losses on the lines and DG placement must be appropriate to obtain minimal power loss. Using ETAP 12.6, the sensitivity of power losses and the sensitivity of network voltages of Marapalam distribution network are calculated. The optimal location on DG photovoltaic is on a 147B bus with a power injection of 75%, able to reduce active and reactive power losses from 35,792 kW and 57,363 kVar to 8,159kW and 13,079kVar. While the optimal location on DG wind turbine is on bus 293T with penetration of 45% of the power supplied to the Marapalam line, able to reduce the active and reactive power to 24,89kW and 39,9kVar.Keywords : Distributed Generator power loss, sensitivity analysisAbstrakPenelitian ini bertujuan untuk untuk mengurangi rugi daya dan meningkatkan profil tegangan berdasarkan penempatan dan kapasitas DG yang optimal di jaringan distribusi penyulang Marapalam. Metode yang digunakan adalah metode Sensitivity analisis dengan salah satu analisisnya adalah menggunakan Loss Sensitivity Factor (LSF) dan metode Voltage Sensitivity Index (VSI). Hasil kedua metode ini dibandingkan dengam metode trial and error. DG dapat mengurangi rugi daya pada saluran dan penempatan DG yang tepat untuk mendapatkan rugi daya yang minimal. ETAP 12.6 diaplikasikan untuk menghitung sensitivitas rugi daya, sensitivitas tegangan jaringan guna memperoleh penempatan DG yang optimal. Berdasarkan studi kasus jaringan distribusi penyulang marapalam, diperoleh lokasi optimal dari DG photovoltaic adalah pada bus 147B dengan injeksi daya sebesar 75%  daya yang disalurkan ke saluran Marapalam. Penempatan ini mampu mengurangi rugi daya aktif dan reaktif dari 35,792 kW dan 57,363 kVar menjadi 8,159kW dan 13,079kVar. Sedangkan lokasi yang optimal dari DG turbin angin adalah pada bus 293T dengan penetrasi 45% dari daya yang disalurkan ke saluran Marapalam mampu mengurangi rugi daya aktif dan reaktif menjadi 24,89kW dan 39,9kVar.Kata Kunci : Pembangkit Tersebar, rugi daya, analisa sensitivitas.
Tracker Tiga Posisi Panel Surya untuk Peningkatan Konversi Energi dengan Catu Daya Rendah Welly Yandi; Syafii Syafii; Ali Basrah Pulungan
JURNAL NASIONAL TEKNIK ELEKTRO Vol 6, No 3: November 2017
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1470.277 KB) | DOI: 10.25077/jnte.v6n3.468.2017

Abstract

This article describes the use of a three-position tracker to increase the conversion of electrical energy from the sun with a low power supply. The three-position tracker system has been tested using two identical solar panels with 250 Wp capacities mounted flat and with tracker. The testing process carried out for 3 days in the top of the building Department of Electrical Engineering Andalas University of Padang. The test results show the average percentage increase in energy conversion is 0.263 kWh / day or 27.9% per day. While the energy requirement for three position tracker actuator are 0.624 Wh / day and track control system of 18 Wh / day. So that the energy consumption of tracker system three positions is equal to 0.0186 kWh / day. This is because the three-position tracker system uses actuators with DC motors equipped with a gearbox so that the tracker's torque becomes greater. Energy consumption for tracker control using arduino is greater than tracker energy itself because the control is always active for 24 hours. While the three-position tracker is only active for 100 seconds. Thus, the energy consumption used by the three-position tracker system is much smaller than the increase in energy conversion produced by solar panels.Keywords : Three position tracker, Increased solar panel energy conversionAbstrak Artikel ini memaparkan tentang penggunaan tracker tiga posisi untuk meningkatkan konversi energi listrik dari matahari dengan catu daya rendah. Sistem tracker tiga posisi telah diuji menggunakan dua buah panel surya yang identik dengan kapasitas 250 Wp yang dipasang flat dan dengan tracker. Proses pengujian dilakukan selama 3 hari di atas gedung Jurusan Teknik Elektro Universitas Andalas Padang.  Hasil pengujian menunjukkan  persentase rata-rata peningkatan konversi energi sebesar 0,263 kWh/hari atau 27,9% per hari. Sedangkan kebutuhan energi untuk aktuator tracker tiga posisi sebesar 0,624 Wh/hari dan sistem kontrol tracker sebesar 18 Wh/hari. Sehingga besar konsumsi energi sistem tracker tiga posisi adalah sebesar 0,0186 kWh/hari. Hal ini disebabkan karena sistem tracker tiga posisi menggunakan aktuator dengan motor DC yang dilengkapi gearbox sehingga kemampuan torsi tracker menjadi lebih besar. Konsumsi energi untuk pengontrolan tracker menggunakan arduino lebih besar dibandingkan energi tracker itu sendiri karena pengontrolan selalu dalam keadaan aktif selama 24 jam. Sementara tracker tiga posisi hanya aktif selama 100 detik. Dengan demikian, konsumsi energi yang digunakan oleh sistem tracker tiga posisi jauh lebih kecil dibandingkan peningkatan konversi energi yang dihasilkan panel surya.Kata Kunci : Tracker tiga posisi, Peningkatan konversi energi panel surya
Antena Mikrostrip Linear Array dengan Slot U untuk Internal Pesawat Televisi pada Band Frekuensi UHF Aditya Wardhani; Ikhwana Elfitri
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (759.391 KB) | DOI: 10.25077/jnte.v7n1.470.2018

Abstract

Television (TV) can be considered as the most popular information media. TV at Ultra High Frequency (UHF) normally has larger size of antenna than the TV terminal itself, and is usually connected as external equipment so that they are not suitable for portable TV terminal. In this paper, a 4-element linear array microstrip antenna with U-slot has been designed. Simulation with Zeland IE3D shows that the proposed antenna is capable of operating at frequency of 486 – 734 MHz (within overall UHF band) and has a relatively smaller size with dimension of 80 x 27 cm, hence it is suitable for TV with screen size larger than 32 inch. The results of the experiment also show that the antenna can achieve Gain higher than 3.5 dB.Keywords : Ultra High Frequency (UHF), Microstrip Antenna, U-SlotAbstrakTelevisi (TV) adalah salah satu media informasi yang sangat populer di masyarakat. Antena TV pada frekuensi UHF yang saat ini tersedia umumnya berukuran relatif besar dan dipasang di luar pesawat TV sehingga kurang cocok apabila diterapkan pada peralatan yang bersifat portable. Pada tulisan ini dirancang sebuah antenna mikrostrip dengan slot berbentuk U dan disusun secara linear array empat elemen. Hasil simulasi menggunakan perangkat lunak Zeland IE3D menunjukkan bahwa antena yang dirancang mampu bekerja pada rentang frekuensi 486 – 734 MHz (keseluruhan rentang frekuensi UHF) dan memiliki ukuran yang relatif kecil yakni 80 x 27 cm, sehingga cocok dipasang pada TV dengan ukuran minimal 32 inchi. Hasil simulasi juga memperlihatkan bahwa antena yang dirancang memiliki Gain lebih besar dari 3.5 dB.Kata Kunci : Ultra High Frequency (UHF), Antena Mikrostrip,U-Slot.
Implementasi Electrinic Nose Dan Support Vector Machine Pada Aplikasi Olfactory Mobile Robot Dalam Mengenali Gas Rendyansyah - Rendyansyah; Aditya P.P. Prasetyo; Kemahyanto Exaudi
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (917.809 KB) | DOI: 10.25077/jnte.v7n1.475.2018

Abstract

The aroma of gas can be perceived by the human sense of smell. The presence of the scent comes from the gas source itself or the gas leaks through cracks such as valves or pipe connections. The smell of certain gases (gas with a stinging smell) can disrupt the human nervous system and nose. Hence, it is required a tool that can mimic the sense of smell which is called the electronic nose (abbreviated to e-nose). E-nose is a combination of two or more gas sensors. In a situation of searching the source of the gas scent, the e-nose was developed into a mobile robotic olfactory application for detection and identification process. In this study, the system was designed to recognize ethanol, benzene and thinner gases. The signal pattern recognition of e-nose uses the Support Vector Machine (SVM) programmed into the computer. Illustration of gas scent detected by e-nose produces a pattern of electrical signals that are wirelessly transferred to a computer and processed to be recognizable. The experimental results show that olfactory mobile robots can be applied to detect and identify types of gas with good accuracy, according to the value above 97% for kernel selection γ = 100 and γ = 1000.Keywords : E-nose, Olfactory Mobile Robot, Support Vector MachineAbstrak Aroma gas dapat dirasakan oleh indra penciuman manusia. Adanya aroma karena berasal dari sumber gas itu sendiri atau gas bocor melalui cela-cela seperti katup atau sambungan pipa. Aroma gas tertentu (gas dengan aroma yang menyengat) dapat mengganggu sistem saraf dan hidung manusia. Oleh karena itu perlu alat yang dapat meniru indra penciuman yaitu electronic nose (disingkat e-nose). E-nose merupakan kumpulan dari dua sensor gas atau lebih. Dalam situasi pencarian sumber aroma gas maka pada penelitian ini dikembangkan e-nose kedalam bentuk aplikasi olfactory mobile robot untuk deteksi dan identifikasi. Pada penelitian ini sistem dirancang untuk mengenali gas etanol, benzene dan thiner. Pengenalan pola sinyal dari e-nose menggunakan Support Vector Machine (SVM) yang sudah diprogram di dalam komputer. Secara ilustrasi aroma gas yang dideteksi oleh e-nose menghasilkan pola sinyal elektrik yang ditransfer via wireless ke komputer dan diproses untuk dikenali. Hasil percobaan menunjukkan bahwa olfactory mobile robot dapat diaplikasikan untuk mendeteksi dan mengidentifikasi jenis gas dengan akurasi yang baik, yaitu di atas 97% untuk pemilihan kernel γ = 100 dan γ = 1000.Kata Kunci : E-nose, Olfactory Mobile Robot, Support Vector Machine
Analisa Kinerja Pengkodean Kanal Type Reed Solomon Coding pada Kualitas Transmisi Citra Baharuddin Abbas
JURNAL NASIONAL TEKNIK ELEKTRO Vol 7, No 1: March 2018
Publisher : Jurusan Teknik Elektro Universitas Andalas

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (597.945 KB) | DOI: 10.25077/jnte.v7n1.480.2018

Abstract

In the telecommunication systems, the data like audio, image, and video are transmitted to a receiver through a communication channel. However, the presence of noise and fading in the channel will degrade its performance. The degradation may cause error on signal detection and change the bits or symbols on the receiver. By applying a RS Code channel coding technique on the transmitter and the receiver, it may improve the performance of digital communication system. The influence of employing the RS Code channel coding technique on the system with noise Additive White Gaussian Noise (AWGN) and Rayleigh fading has been analyzed through a simulation. Performance evaluation on the use of RS Code channel coding technique can be determined from the analysis of Bit Error Rate (BER) and Peak Signal to Noise Ratio (PSNR). The simulation result shows that the system is improved by 5dB on the receiver compares to the system without using RS Code channel coding technique. Keywords : Reed Solomon Code , Noise AWGN, Fading Rayleigh, PSNR, BER AbstrakDalam sistem telekomunikasi, data multimedia berupa audio, citra, dan video ditransmisikan ke penerima melalui sebuah kanal komunikasi. Pada sistem telekomunikasi yang menggunakan kanal komunikasi wireless, selain pengaruh redaman, gangguan yang paling dominan adalah noise dan fading. Fading dan noise dikanal akan menurunkan kinerja sistem telekomunikasi digital karena dapat menyebabkan terjadinya kesalahan pendeteksian sinyal, sehingga terjadi perubahan bit atau simbol pada sisi penerima. Dengan menerapkan teknik pengkodean kanal tipe Reed Solomon Code pada sisi pengirim dan penerima, maka dapat ditingkatkan kinerja dari sistem komunikasi digital tersebut. Melalui simulasi dalam penelitian ini, telah dianalisa pengaruh penerapan teknik pengkodean kanal Reed Solomon Code pada sistem yang dipengaruhi noise Additive White Gaussian Noise (AWGN) dan fading Rayleigh. Besarnya pengaruh penggunaan dari teknik pengkodean kanal Reed Solomon Code dapat diketahui melalui analisa Bit Error Rate (BER) dan Peak Signal to Noise Ratio (PSNR). Hasil simulasi dari penelitian ini menunjukkan bahwa adanya peningkatan perbaikan sistem dipenerima rata-rata 5dB bila dibandingkan dengan tanpa menggunakan teknik pengkodean kanal Reed Solomon Code.Kata Kunci : Reed Solomon Code , Noise AWGN, Fading Rayleigh, PSNR, BER