Claim Missing Document
Check
Articles

Found 3 Documents
Search
Journal : Teras Jurnal

STRUT AND TIE MODEL STRUKTUR BALOK TINGGI BERLUBANG Nazila, Kamila Shaomi; Priastiwi, Yulita Arni; Sukamta, Sukamta
Teras Jurnal : Jurnal Teknik Sipil Vol. 11 No. 1 (2021): Maret 2021
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v11i1.362

Abstract

Abstrak Mendesain suatu bangunan tingkat tinggi dengan tidak menggunakan plafon dibutuhkan perencanaan yang ekonomis tanpa mengurangi kekuatan dan keindahan dari bangunan tersebut. Balok tinggi berlubang dengan material struktur beton digunakan untuk menghindari terjadinya sistem utilitas pada suatu bangunan tingkat tinggi dengan tidak menggunakan plafon. Balok tinggi berlubang ini ditinjau menggunakan metode Strut and Tie Model (STM). Untuk mengatasi permasalahan yang ada biasanya para perencana merancang daerah D (Disturbed Region) dengan menggunakan konsep pendetailan berdasarkan aliran gaya, sehingga metode strut and tie merupakan pendekatan yang sesuai untuk menganalisis struktur beton di daerah D. Program analisa struktur digunakan untuk melakukan analisis gaya dalam berupa momen dan geser pada struktur beton balok tinggi berlubang. Hasil analisis yang diperoleh pada struktur beton balok tinggi berlubang yaitu bahwa semakin dekat lubang balok dengan tumpuan maka nilai tulangan lentur akan lebih tinggi dan semakin bertambah pula tulangan gesernya. Kata kunci: Balok Tinggi Berlubang, Daerah D, Metode Strut and Tie  Abstract Designing a high rise building without using a ceilings requires an economical plan without reducing the strength and the art of the building. The deep beam with holes, which have the structure of concrete materials is need to be used to avoid the utility system in a high rise building without ceilings. This deep beam with holes is reviewed by the Strut and Tie Model (STM) method. To solve the existing problems, planners usually design the D region (Disturbed Region) use the concept of detail based on the flow of force. So the strut and tie method is an appropriate method to analyze the structure of concrete at D region (Disturbed Region). The program of analysis structure is used to analyze the internal forces, which are Moment and Shear, in the deep beams with holes' structure. The result of the analysis in the  deep beam concrete with holes is the more position of the hole is close to its pedestal, the value of the Flexural reinforcement will be more increase, and teh Shear reinforcement will be higher too. Keywords: Deep Beam Hollow, D Region, Strut and Tie Model
ANALISIS ALTERNATIF DALAM MERANCANG BALOK TINGGI MENGGUNAKAN STRUT AND TIE MODEL Luthfiana, Nisa; Priastiwi, Yulita Arni
Teras Jurnal : Jurnal Teknik Sipil Vol. 11 No. 1 (2021): Maret 2021
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v11i1.393

Abstract

Abstrak Perencanaan struktur beton biasanya dilakukan dengan berdasarkan asumsi dari Bernoulli dan Navier untuk menganalisis penampang akibat momen lentur. Distribusi regangan dianggap linier dan ini dianggap masih berlaku meskipun penampang telah retak. Balok tinggi merupakan salah satu contoh kasus pada suatu elemen struktur yang dapat mengakibatkan terjadinya distribusi tegangan non linier, sehingga asumsi diatas tidak berlaku. Balok dikatakan balok tinggi apabila rasio bentang terhadap tingginya lebih kecil dari lima. Salah satu alternatif pendekatan untuk mengatasi elemen struktur seperti balok tinggi adalah menggunakan pendekatan Strut and Tie Model, yaitu dengan membagi struktur dalam daerah B (Bernoulli) dan D (Disturb) dan menggambarkan alur gaya (load path) sebagai transfer gaya yang terjadi pada struktur beton bertulang pada kondisi retak akibat pembebanannya. Parameter-parameter dari Strut and Tie Model yaitu batang tekan (strut), batang tarik (tie) dan titik nodal (nodal zone) sebagai daerah pertemuan. Tujuan dari tulisan ini adalah untuk menganalisis alternatif perencanaan/desain tulangan struktur balok tinggi beton bertulang diatas dua tumpuan sederhana akibat beban merata yang dikonversi menggunakan beban terpusat 2 titik pembebanan.Metode yang digunakan adalah Strut and Tie Model yang akan menghasilkan luas tulangan longitudinal yang lebih kecil dengan selisih 25%, di mana dengan luas tulangan yang lebih kecil dari segi kekuatan masih memenuhi syarat. Hal ini menunjukkan bahwa perhitungan perencanaan balok tinggi tanpa bearing plate dengan menggunakan metode Strut and Tie Model pun dapat lebih optimum/efisien. Kata kunci: Prinsip Bernoulli, Strut and Tie Model, D - Region, B - Region   Abstract Concrete structure planning is usually carried out based on the assumptions of Bernoulli and Navier to analyze the section due to bending moments. The strain distribution is considered linear and it is considered still valid even after the section has cracked.  The deep beam is one example of a structural element that can result in a non-linear stress distribution, so the above assumption does not apply. A beam is said to be a deep beam if the span to height ratio is less than five. One alternative approach to dealing with structural elements such as deep beams is to use the Strut and Tie Model approach, namely by dividing the structure into areas B (Bernoulli) and D (Disturb) and describing the load path as a force transfer that occurs in the concrete structure. Reinforced in cracked conditions due to loading. The parameters of the Strut and Tie Model are the strut, tie, and nodal zone as the meeting area. The purpose of this paper is to analyze the alternative planning/design of reinforced concrete beams structure on two simple supports due to evenlydistributed loads that are converted using the two-point load centered load. The method used is the Strut and Tie Model which will produce a smaller area of longitudinal reinforcement with a difference of 25%, where the area of reinforcement is smaller in terms of strength still meets the requirements. This shows that the calculation of deep beam planning without bearing plate using the strut and tie model method can be more optimal/efficient. Keywords: Bernoullis Principle, Strut and Tie Model, D - Region, B - Region
Pemanfaatan Batu Pumice Dalam Mengurangi Penurunan Performa Beton Pasca Kebakaran Thoyfurrohman, Muhammad Akhis; Cahyo, Bagas Indra; Yulianti, Erika; Nuroji, Nuroji; Priastiwi, Yulita Arni
Teras Jurnal : Jurnal Teknik Sipil Vol. 12 No. 1 (2022): Volume 12 Nomor 1, Maret 2022
Publisher : UNIVERSITAS MALIKUSSALEH

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.29103/tj.v12i1.569

Abstract

Abstrak Beton yang mengalami kebakaran pada suhu 400ËšC akan mengalami degradasi kekuatan hingga kuat tekan sisa 58,40% Hal ini akan mempengaruhi kualitas/kekuatan struktur beton tersebut dan akan menyebabkan beton menjadi getas, dan memungkinkan struktur mengalami kegagalan. Diperlukan upaya proteksi pasif kebakaran dengan menggunakan material yang memiliki ketahanan terhadap api. Salah satu material yang memiliki ketahanan terhadap api yang baik adalah batu pumice. Penelitian ini bertujuan untuk mengetahui nilai kuat tekan dan laju penurunan kekuatan beton pumice yang menggunakan Pasir Muntilan sebagai agregat halus akibat perubahan suhu pembakaran pada 27°C, 300°C, dan 600°C. Penelitian menggunakan 45 buah benda uji silinder beton berukuran diameter 15 cm dan tinggi 30 cm. Dengan variasi penggantian batu pumice 0% , 25%, 50%, 75% dan 100% dari volume agregat kasar dan Faktor Air Semen (FAS) sebesar 0,5. Pengujian kuat tekan dengan alat compression saat umur 28 hari. Hasil penelitian ini menunjukkan bahwa suhu pembakaran mempengaruhi kuat tekan beton pumice dengan pasir Muntilan pada semua komposisi proporsi. Semakin tinggi suhu pembakaran maka semakin besar penurunan yang terjadi. Besaran penurunan kuat tekan akibat kenaikan suhu pembakaran berkisar antara 0,16% hingga 55,38% lebih lambat dibandingkan dengan beton tanpa menggunakan batu pumice Kata kunci: Beton, Batu Pumice, Performa Beton  Abstract Concrete that has been burned at 400° C will experience degradation to a residual compressive strength of 58.40%. This will affect the strength of the concrete structure and will cause the concrete to become brittle, thus allowing the structure to fail. Then it will require passive fire protection by using materials that have some resistance to the fire. One material that has the potential to create fire resistance is pumice stone. The purpose of this study was to determine the value of compressive strength and the rate of reduction in compressive strength of Muntilan sand pumice concrete due to the changes in combustion temperature of 27ËšC,300ËšC, and 600ËšC. In this study, used a 45 pieces concrete cylinder with a diameter of 15 cm and a height of 30 cm. with variations of pumice stone proportion of 0%, 25%, 50%,75% and 100% of the volume of coarse aggregate with a water cement ratio of 0.5. Compressive strength test with a compression device at the age of 28 days. The results of this study indicate that the combustion temperature affects the compressive strength of pumice concrete. The higher the combustion temperature, the higher the strength reduction that occurs. The amount of reduction in compressive strength due to an increase in combustion temperature ranged from 0.16% to 55.38% of the control specimens. Keywords: Pumice, Compressive Strength, Temperature