Claim Missing Document
Check
Articles

Found 4 Documents
Search
Journal : Extrapolasi

KINERJA STRUKTUR GEDUNG BETON BERTULANG DENGAN BENTANG KANTILEVER 4 M MENGGUNAKAN METODE ANALISIS PUSHOVER Trimurtiningrum, Retno; Saves, Faradlillah; Fatmawati, Laily Endah; Setiawan, Yusak Adi
EXTRAPOLASI Vol 17 No 2 (2020)
Publisher : Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30996/exp.v17i2.4429

Abstract

AbstractThe advance of technology and design in construction field are developing. Therefore, variety of structural design becomes unique. The shape of building with cantilever seems increasingly atrractive because it is rated to have high architecture. Cantilever form with a longer span of more than 1/3 L is increasingly desirable because it provides a unique exterior appearance,as well as a double function other than as a room can also functioned as a canopy.The building is designed to be a 7-storey building with cantilever beam on the 6th – 7th floor for 4 m. This study used the reference of SNI 03-2847-2013 in designing the main structural elements of reinforced concrete, SNI 03-1726-2012 for the designing the earthquake load, SNI 03-1727-2013 and PPIUG1983 for gravity load planning. From the results of analysis, the interstory drift that occurs both the X-direction and the direction of Y is 50.544 mm and 39.956 mm, each of which qualifies the interstory drift limit according to SNI 03-1726-2012. Structural performance levels are being catagories in immediate occupancy level which means there is no structural damage and the building can be used immediately according to its function AbstrakKemajuan teknologi dan desain di bidang konstruksi semakin berkembang. Hal tersebut, membuat beragamnya variasi desain struktur yang semakin hari semakin unik. Bentuk-bentuk gedung dengan kantilever tampaknya semakin diminati karena dinilai mempunyai arsitektur yang tinggi. Bentuk kantilever yang mempunyai bentang lebih panjang, yaitu lebih dari 1/3 L makin diminati karena memberikan tampilan eksterior yang unik, serta dapat berfungsi ganda selain sebagai ruangan juga dapat difungsikan sebagai kanopi. Gedung yang didesain merupakan gedung 7 lantai dengan balok kantilever pada lantai 6 dan 7 sepanjang 4 m. Penelitian ini menggunakan acuan SNI 03-2847-2013 dalam mendesain elemen struktur utama beton bertulang, SNI 03-1726-2012 untuk perencanaan beban gempa, SNI 03-1727-2013 dan PPIUG 1983 untuk perencanaan beban gravitasi. Dari hasil analisis didapatkan besar simpangan yang terjadi baik arah x maupun arah Y adalah sebesar 50,544 mm dan 39,956 mm, dimana masing-masing memenuhi syarat batas simpangan antar lantai sesuai SNI 03-1726-2012. Level kinerja struktur termasuk level immediate occupancy yang berarti tidak terjadi kerusakan structural dan gedung dapat segera dipakai sesuai dengan fungsinya.
PERENCANAAN POLA TANAM PADA JARINGAN IRIGASI GANGSIRAN DESA TEBEL KABUPATEN JOMBANG Saves, Faradlillah
EXTRAPOLASI Vol 18 No 1 (2021)
Publisher : Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30996/exp.v18i1.5216

Abstract

AbstractThe availability ofiwateriin the jombang area tends to be uneven because it is influenced by the rain and dry season. This makes the implementation of the cropping pattern in the village of Tebel Bareng district not in accordance with the available water availability, to obtain maximum production a goog irrigation system management is required. By conducting an analysis to determine the value of the monthly reliable discharge with the transformation of monthly rainfall data, water requirements and cropping patterns are expectedito be able to overcome problems that occur in the existing irrigation network in Tebel village Bareng sub-district Jombang district. To find out the average rainfalliusingitheialgebraic averageimethod with 10 years of rainfall data, then to find out the evapotranspiration is calculated using the penman method and reliable discharge calculations using the FJ Mock method. From the results of the analysis on the village irrigation in Tebel the reliable discharge value is 0,0165 m³/sec. Analysis of rrigation water needs was carried out using 24 alternatives. TheiNFR value of 88,29 mm/day was converted to 0,001021875 m³/sec or 10,022 l/sec. The alternative used is the 24 th alternative with the initial planting period in December II period. The cropping pettern used is paddy-paddy-secondary crops.AbstrakKetersediaan air didaerah jombang cenderung tidak merata karena dipengaruhi oleh musim hujan dan kemarau. Hal itu membuat pelaksanaan pola tanam di desa Tebel Kecamatan Bareng tidak sesuai dengan ketersediaan air yang ada, sehinga untuk mendapatkan hasil produksi yang maksimal diperlukan sebuah pengelolahan sistem irigasi yang baik. Dengan melakukan analisis untuk mengetahui nilai debit andalan bulanan dengan transformasi data curah hujan bulanan, kebutuhan air dan pola tata tanam diharapkan mampu mengatasi masalah yang terjadi pada jaringan irigasi yang ada di Desa Tebal Kecamatan Bareng Kabupaten Jombang. Untuk mengetahui curah hujan rata-rata menggunakan metode rata-rata aljabar dengan data curah hujan 10 tahun, lalu untuk mengetahui evapotranspirasi dihitung menggunakan metode penman dan perhitungan debit andalan diperoleh dengan menggunakan metode FJ. Mock. Dari hasil analisis pada daerah irigasi desa Tebel diperoleh nilai debit andalan sebesar 0,0165 m³/detik. Analisis kebutuhan air irigasi dilakukan menggunakan 24ialternatif Didapat nilai NFR sebesar 88,29 mm/hari dikonversikan menjadi 0,001021875 m³/detik atau 10,022 lt/detik. Alternatifiyang digunakan adalah alternatifike 24 dengan masa awal tanam pada Desember priode II. Pola tanam yang digunakan adalah padi-padi-palawija.
ANALISIS DEBIT AIR ANDALAN PDAM DI DAERAH ZONA 5 WILAYAH SURABAYA BARAT PERTUMBUHAN PENDUDUK TAHUN 2028 Saves, Faradlillah; Rochmah, Nurul; Putra, R. Firdaus Alamsyah
EXTRAPOLASI Vol 17 No 1 (2020)
Publisher : Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30996/exp.v17i1.3614

Abstract

AbstractPDAM Surya Sembada Surabaya City is a regional company authorized to produce and distribute water to customers. Utilization is not only limited to household needs, but also for public facilities. Along with the growth of clean water, of course, it will increase as well. This Final Project will explain the calculation of the reliable discharge of PDAM Surya Sembada Surabaya City in the Zone 5 area of West Surabaya Region. It also analyzes population growth projections using the Arithmetic and Geometric methods and calculates water needs, so that the water needs of PDAMs in Zone 5 can be identified. West Surabaya Region in the next 10 years, namely in 2028. After knowing the reliable discharge and water needs of PDAMs in the Zone 5 area of West Surabaya Region, the water balance can be known. PDAM water demand in the Zone 5 region of West Surabaya Region in the next 10 years, namely in 2028, is 3,914.59 liters / second smaller than the current mainstay discharge based on data from PDAM Surya Sembada of Surabaya, which is 3,955.99 liters / second. This means that the mainstay discharge of PDAM water for customers in the Zone 5 region of West Surabaya Region is able to meet water needs until 2028. AbstrakPDAM Surya Sembada Kota Surabaya adalah perusahaan daerah yang berwenang untuk memproduksi dan mendistribusikan air kepada pelanggan. Pemanfaatannya tidak hanya terbatas untuk keperluan rumah tangga, tetapi untuk fasilitas umum juga. Seiring dengan pertumbuhan air bersih tentu saja akan semakin meningkat pula. Tugas Akhir ini akan menjelaskan perhitungan debit andalan PDAM Surya Sembada Kota Surabaya di daerah Zona 5 Wilayah Surabaya Barat. Selain itu juga menganalisa proyeksi pertumbuhan penduduk dengan menggunakan metode Aritmatik dan Geometrik serta menghitung kebutuhan air, sehingga dapat diketahui kebutuhan air PDAM di daerah Zona 5. Wilayah Surabaya Barat 10 tahun kedepan yaitu pada tahun 2028. Setelah diketahui debit andalan dan kebutuhan air PDAM di daerah Zona 5 Wilayah Surabaya Barat, maka dapat diketahui keseimbangan airnya. Kebutuhan air PDAM di daerah Zona 5 Wilayah Surabaya Barat 10 tahun kedepan yaitu pada tahun 2028 adalah 3.914,59 liter/detik lebih kecil dari debit andalan saat ini yang didasarkan dari data PDAM Surya Sembada Kota Surabaya yaitu sebesar 3.955,99 liter/detik. Artinya debit andalan air PDAM untuk pelanggan di daerah Zona 5 Wilayah Surabaya Barat mampu memenuhi kebutuhan air sampai tahun 2028.
PERENCANAAN POLA TANAM PADA JARINGAN IRIGASI GANGSIRAN KABUPATEN JOMBANG Saves, Faradlillah; Widhiarto, Herry; Fatmawati, Laily Endah
EXTRAPOLASI Vol 18 No 2 (2021)
Publisher : Universitas 17 Agustus 1945 Surabaya

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30996/extrapolasi.v18i2.6023

Abstract

AbstrakKondisi musim di Kabupaten jombang yaitu musim hujan dan kemarau membuat ketersediaan air didaerah tersebut tidak merata. Hal ini tentu diperlukan perencanaan pola tata tanam yang tepat pada jaringan irigasi gangsiran Desa Tebel Kecamatan Bareng agar terjadi kestabilan antara ketersediaan dan kebutuhan. Untuk mengetahui curah hujan rata-rata menggunakan metode rata-rata aljabar dengan data curah hujan 10 tahun yaitu 2009 - 2018, lalu untuk mengetahui evapotranspirasi dihitung menggunakan metode penman dan perhitungan debit andalan diperoleh dengan menggunakan metode FJ. Mock. Dari hasil analisis pada daerah irigasi desa Tebel diperoleh nilai debit andalan sebesar 0,017 m³/detik.Berdasarkan debit andalan tersebut diperoleh nilai NFR sebesar 88,29 mm/hari dengan perencanaan pola tata tanam padi-padi-palawija.AbstractSeasonal conditions in Jombang Regency, namely the rainy and dry seasons make the availability of water in the area uneven. This certainly requires planning the right cropping pattern on the gangsiran irrigation network in Tebel Village, Bareng District so that there is stability between availability and demand. To find out the average rainfall using the algebraic average method with rainfall data for 10 years, namely 2009 - 2018, then to find out evapotranspiration is calculated using the Penman method and the reliable discharge calculation is obtained using the FJ method. mock. From the analysis results in the irrigation area of Tebel village, the mainstay discharge value is 0.017 m³/second