RANCANG BANGUN ALAT PORTABLE WARMER CABINET BERBASIS MIKROKONTROLER ARDUINO UNO R3 ZENDRATO, JOFAN RESTU JUA PUTRA; DABUKKE, HOTROMASARI; ULINA, SRI; PRIMASYUKRA, MHD. ALDI
JURNAL MUTIARA ELEKTROMEDIK Vol. 9 No. 1 (2025): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v9i1.6199

Abstract

Latar belakang: Portable warmer cabinet dirancang untuk memenuhi kebutuhan pemanasan cairan infus secara efisien, ringan, dan praktis di berbagai kondisi. Alat ini bertujuan untuk memastikan suhu cairan infus hangat sebelum di berikan kepada pasien tetap steril dan menjadi Solusi dalam mengatasi hipotermia, serta siap digunakan tanpa memerlukan alat pemanas besar. Tujuan: Penelitian ini bertujuan untuk merancang dan mengembangkan alat portable warmer cabinet yang berukuran kecil atau efesien berbasis mikrokontroler Arduino uno R3, menggunakan sensor DS18B20, relay, heater dan LCD 16x2 I2C sebagai layar monitor. Metode: Pendekatan eksperimen digunakan dalam penelitian ini, dengan data kuantitatif diperoleh dari pengukuran suhu, waktu pemanasan, dan konsumsi daya. Analisis naratif menggambarkan proses perancangan, pengembangan, dan pengujian alat. Hasil: Alat ini mampu menjaga suhu antara 37–50°C dengan deviasi ±0.5°C. Waktu pemanasan rata-rata adalah 8 menit untuk mencapai suhu optimal, dengan konsumsi daya 50 watt. Simpulan: Portable warmer cabinet yang dirancang berhasil memenuhi kebutuhan akan alat pemanas praktis dan efisien untuk aplikasi medis.
RANCANG BANGUN PEMANTAUAN SUHU PADA ALAT INFUSION WARMER CABINET PORTABLE BERBASIS MIKROKONTROLER ARDUINO HALAWA, TOMI SAPUTRA; SITUMORANG, HAROLD; DABUKKE, HOTROMASARI; ABDILLAH, KHAIRIL
JURNAL MUTIARA ELEKTROMEDIK Vol. 9 No. 1 (2025): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v9i1.6200

Abstract

Latar Belakang: Infusion Warmer Cabinet adalah perangkat medis untuk menghangatkan cairan infus sebelum diberikan ke pasien. Penelitian ini merancang sistem pemantauan suhu dengan sensor DS18B20 dan mikrokontroler Arduino Uno. Suhu ditampilkan pada LCD 16x2, dikendalikan oleh relay, dan diatur dengan tombol tekan. Pengujian menunjukkan sistem mampu memantau suhu dengan tingkat kesalahan rendah, menjadikannya alternatif perangkat pemantau penghangat infus. Tujuan: Membuat rancang bangun pemantauan suhu pada alat penghangat cairan infus atau warmer cabinet portable berbasis mikrokontroler Arduino uno dengan inovasi memiliki sistem pemantauan, memiliki ukuran yang portable, dan harga yang lebih terjangkau dibandingkan dengan alat warmer cabinet / penghangat cairan infus yang sudah di jual belikan. Metode Penelitian ini menerapkan pendekatan eksperimen, dimana data kuantitatif dikumpulkan melalui pengukuran suhu, durasi pemanasan.analisis naratif digunakan untuk mendeskripsikan proses perancangan, pengembang. Hasil: Perangkat ini dapat memantau suhu ruang cabinet samapai 70°C dengan toleransi deviasi ±0,5°C. Rata-rata waktu yang diperlukan untuk mencapai suhu optimal adalah 8 menit. Simpulan: Alat Pemantauan suhu pada warmer cabinet portable yang telah dirancang berhasil memenuhi kebutuhan akan alat pemantau pemanas praktis dan efisien untuk aplikasi medis.
SOSIALISASI MONITORING SUHU DAN KELEMBAPAN BABY INCUBATOR MENGGUNAKAN SENSOR DHT11 Naomi Hutabarat; Dabukke, Hotromasari; Adiansyah; Salomo Sijabat; Berkat Panjaitan
Jurnal Abdimas Mutiara Vol. 6 No. 2 (2025): JURNAL ABDIMAS MUTIARA (IN PRESS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/jam.v6i2.6174

Abstract

Sosialisasi Sosialisasi Monitoring Suhu Dan Kelembaban Baby Incubator Menggunakan Sensor DHT11 berjalan dengan baik. Kegiatan ini dilakukan di klinik kesehatan dan di ikuti oleh user. Metode yang digunakan observasi, ceramah dan eksperiman. Tujuan kegiatan ini adalah untuk menambah pengetahuan user dalam melakukan pemantauan Suhu Dan Kelembaban Baby Incubator Menggunakan Sensor DHT11. Perawatan bayi baru lahir, khususnya bayi prematur, sangat bergantung pada kestabilan suhu dan kelembapan di dalam inkubator. Sensor DHT11 merupakan salah satu sensor yang mengukur suhu dan kelembapan di sekitarnya. Hasil pembacaan suhu dan kelembapan ditampilkan secara real-time melalui LCD display, sehingga memudahkan tenaga medis melakukan pemantauan tanpa harus membuka inkubator. Pada Sistem monitoring ini, sensor di setting hanya mendeteksi suhu kelembapan dengan rentang nilai 30% - 75% dalam rentang suhu 33℃− 37℃, maka sistem akan mengaktifkan buzzer sebagai peringatan dini. Kegiatan pengabdian kepada masyarakat tentang menunjukkan bahwa teknologi sederhana berbasis mikrokontroler dapat dimanfaatkan sebagai solusi tepat guna dalam mendukung layanan kesehatan, khususnya neonatal. Dukungan pelatihan dan keterlibatan aktif mitra berperan penting dalam keberlanjutan penggunaan alat ini.
SOSIALISASI DAN IMPLEMENTASI ALAT MONITORING ALIRAN UDARA PADA BED DECUBITUS BERBASIS ARDUINO UNO DI RUMAH SAKIT UMUM ESHMUN Sri Ulina; Mhd Aldi Primasyukra; Khairil Abdillah; Hotromasari Dabukke; Juli Yanti Simanullang; M . Rendi Wardana
Jurnal Abdimas Mutiara Vol. 6 No. 2 (2025): JURNAL ABDIMAS MUTIARA (IN PRESS)
Publisher : Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/jam.v6i2.6212

Abstract

Latar belakang: Luka dekubitus merupakan salah satu komplikasi serius yang dialami pasien dengan imobilisasi jangka panjang, khususnya pada pasien di ruang ICU atau pasien geriatri. Upaya pencegahan luka tekan sangat penting untuk meningkatkan kenyamanan dan keselamatan pasien selama menjalani perawatan. Tujuan: Kegiatan Pengabdian Kepada Masyarakat (PKM) ini bertujuan untuk meningkatkan pemahaman tenaga medis serta memperkenalkan solusi inovatif berupa sistem bed decubitus berbasis Arduino Uno yang mampu memonitor aliran udara secara real time menggunakan sensor YF-S201. Metode: Metode pelaksanaan terdiri atas seminar, demonstrasi langsung alat, serta uji coba terbimbing pada pasien dummy di ruang perawatan. Hasil: Hasil dari kegiatan ini menunjukkan antusiasme tinggi dari peserta serta efektivitas sistem monitoring udara dalam menjaga kestabilan tekanan matras secara otomatis. Kesimpulan: Kegiatan ini diharapkan menjadi langkah awal dalam adopsi alat kesehatan inovatif berbasis teknologi lokal yang terjangkau dan aplikatif di lingkungan klinis
ANALISIS BERKAS SINAR-X PADA PERISAI RADIASI BERBASIS POLYESTER TIMBAL ASETAT DI MURNI TEGUH MEMORIAL HOSPITAL Dabukke, Hotromasari; Aritonang, Fitler; Sijabat, Salomo
JPFT (Jurnal Pendidikan Fisika Tadulako Online) Vol. 9 No. 1 (2021): JPFT (Jurnal Pendidikan Fisika Tadulako Online)
Publisher : Universitas Tadulako

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22487/jpft.v9i1.792

Abstract

This research was about the effect of polyester resin as a matrix, and lead acetate as filler in the manufacture of X-ray radiation shields in order to determine its characteristics on physical, mechanical and thermal properties at Murni Teguh Memorial Hospital. Lead acetate was varied (0, 2, 4, 6, 8, and 10) wt% with variations in sample thickness of 0.5 cm, 0.75 cm, 1.0 cm, 1.25 cm and 1.50 cm. The results showed that the physical properties (density 1.9 gr/cm 3) on the composition of 10% wt lead acetate and 85% wt polyester resin with a thickness of 1.5 cm were the best results. The higher the lead acetate composition, the higher the density value is. The light transmission value of 83% was still in accordance with the ISO standard regarding lead glass. The results of the mechanical properties test (compression test 79 kg/cm3 and hardness test 38) were the best values at the composition of 85:10:5% wt with a thickness of 1.5 cm. This shows that the composition of 85:10:5% wt is the most homogeneous composition resulting in optimum mechanical properties. The results of the DSC test showed that an endothermic temperature of 85:10:5% wt with a thickness of 1.5 cm was the best with a temperature of 3770C. From all radiation shield sample tests, the composition of 85:10:5% wt has the best physical properties and mechanical properties in accordance with ISO and SNI-16-6656-2002 standards regarding lead glass.
RANCANG BANGUN SENSOR WATER LEVEL K-0135 PADA ALAT SUCTION PUMP Wardana, Chandra; Sijabat, Salomo; Abdillah, Khairil; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i2.3565

Abstract

Suction pump is an electromedical device that is used manually with the help of the user which functions to suck fluids that are not needed by the body. Then the liquid that is not needed is accommodated in a container. Suction is often damaged due to the presence of mucus or liquid that enters the motor rotation. So from the above problems, the author made a Suction Pump Modification equipped with a K-0135 Water Level Sensor. This sensor will also read the liquid that enters the tube with Minimum and Maximum level readings (Low, Middle and Full). The sensor on this tube is very necessary to make it easier for the user to know the liquid is almost full. This research will be conducted in the Sari Mutiara University lab. The type of research method is experimental research, namely conducting direct experiments on the designed tools.The measurement results from the K0135 Water Level Sensor are displayed on the LCD, with measurements of Low, Middle and Full level points.
ANALISA PEMELIHARAAN KOREKTIF PADA SYRINGE PUMP Sitorus, Tenberry; Dabukke , Hotromasari; Situmorang, Harold; Priyulida, Fitria
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i2.3568

Abstract

Research has been carried out on the analysis of corrective maintenance on Syringe pumps. Maintenance of medical equipment is very important, which is useful for extending the service life of the equipment and ensuring the performance of the equipment to function according to its specifications. Corrective maintenance is a maintenance activity that is repairing damaged equipment with or without replacement of spare parts. This maintenance is intended to restore the damaged equipment to a usable and operational condition. The purpose of the study was to determine the of the Syringe Pump maintenance. The method used is Observational and Qualitative. The results of the research are Damaged Batteries, Soaks, Empty Alarm Sensors, Syringe Size sensors, Power Supply completely dead, the solution is after measurement and analysis. Syringe Pump found a Syringe size sensor problem that is not functioning properly, the solution is to replace the new Syringe size sensor. Syringe pump Supply is totally dead, the solution is to replace the 5 ampere fuse. Empty on the Syringe Pump is damaged, the solution is to replace the empty sensor. So the solution is to replace the battery with a new battery.
ANALISA PEMELIHARAAN PREVENTIF BABY INKUBATOR Harahap, Gunawan Fahri; Sijabat, Salomo; Situmorang, Harold; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v6i2.3570

Abstract

Baby incubator is a tool that has a function as a treatment and temperature adjustment (heater) for premature babies who really need a temperature that is in accordance with the temperature in the mother's womb. The Baby Incubator uses a heating element that is controlled by a temperature control circuit so that the temperature remains stable. the heater will work when the temperature is less than the predetermined temperature, on the contrary if the temperature sensor is greater than the temperature setting it will automatically turn off. Medical equipment, of course, cannot be separated from damage, both light and heavy, because damage can be caused by improper use of standard operating procedures (SOP), lack of maintenance/maintenance, and incidents/accidents caused by human error. Based on the observations that have been made by the author, it is known that medical equipment requires periodic maintenance to ensure the quality of health services. Preventive maintenance of the baby incubator. Preventive maintenance is maintenance and care activities carried out to prevent damage. Preventive maintenance can be carried out daily or monthly.
ANALISA SISTEM PEMELIHARAAN DAN PERBAIKAN ALAT ELEKTROCARDIOGRAPH Siregar, Adlin Khairi; Sijabat, Salomo; Priyulida, Fitria; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 6 No. 2 (2022): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v1i2.3585

Abstract

Electrocardiograph is a tool that can display a graph of the electrical signal of the human heart that shows the process of the occurrence of a heartbeat. Through this tool it can be known whether a person's heart rate is normal or not. The method used in this study is qualitative and descriptive. preventive maintenance both from outside and inside the tool and aims to find out the maintenance of the el ectrocardiograph tool this maintenance function is running well, then the quality of the medical equipment used will be good too. From the results of the maintenance and testing of the electrocardiograph that was carried out at the Teaching Hospital of the University of North Sumatra, Medan. The maintenance of the electrocardiograph was carried out by internal calibration with measurements of 30,60,120,240.and by looking at the value of the graph whether it was still curly or not.The results of this study indicate that in practice, the system of maintenance cannot run as it should, due to the limited number of technicians, lack of training, costs, and maintenance procedures that are not in accordance with the planning, operation, and supervision procedures that are not carried out properly.
ANALISA PEMELIHARAAN KOREKTIF PADA ALAT INFUS PUMP Ulina, Sri; Khalid, Idham; Primasyukra, Mhd. Aldi; Dabukke, Hotromasari
JURNAL MUTIARA ELEKTROMEDIK Vol. 8 No. 2 (2024): Jurnal Mutiara Elektromedik
Publisher : Prodi Teknik Elektromedik Universitas Sari Mutiara Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51544/elektromedik.v8i2.5515

Abstract

Perangkat pompa infus di Rumah Sakit Universitas Sumatre Utara penelitian ini dilakukan untuk mengetahui masalah perbaikan pada pompa infus. Corrective maintenance adalah tindakan pemeliharaan yang dilakukan untuk mengatasi kerusakan atau kemacetan yang terjadi berulang kali kemudian melakukan tindakan korektif pada alat. Pompa infus adalah peralatan medis yang digunakan untuk menyediakan zat elektroloit tambahan berupa cairan yang disuntikkan ke dalam tubuh pasien dalam jumlah tertentu melalui pembuluh darah. Masalah pompa infus adalah layar tampilan tidak menyala. Solusinya adalah dengan mengganti kabel, baterai lemah Solusinya adalah dengan mengganti baterai baru, sensor jatuh berbunyi dalam kondisi cairan normal Solusinya adalah dengan memperbaiki kabel konektor sensor jatuh. Hasil dan solusi penelitian yaitu pompa infus telah berfungsi dengan baik setelah diperiksa dan diperbaiki. Perawatan infus pompa harus rutin dan terjadwal untuk mencegah kerusakan sehingga masa pakai alat lama. Pengujian dan kalibrasi perangkat infus pompa, terutama pada parameter infus pompa, harus diperiksa secara rutin pada pompa infus.