Claim Missing Document
Check
Articles

Found 15 Documents
Search

Digital Filter Design to Reduce Motion Artifacts in Electrocardiogram Signals Based on IIR Filter Maghfiroh, Anita Miftahul; Setiawan, Singgih Yudha; Mujahid, Muhammad Umer Farooq
Jurnal Teknokes Vol. 16 No. 4 (2023): December
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Developed a new method to overcome motion artifacts in Electrocardiogram (ECG) signals, which often interfere with accurate clinical analysis. Motion artifacts, such as body movements, can cause significant distortions in the ECG signal, resulting in incorrect interpretation and affecting medical diagnosis. The main objective of this research is to design and implement an infinite impulse response (IIR) filter with a predetermined sequence, namely orders 2, 4, 6, and 8 to reduce motion artifacts in the ECG signal. We aim to improve ECG signal quality by preserving important ECG signal information and reducing noise caused by motion artifacts. This research contributes to developing more precise and reliable ECG signal processing techniques. The proposed method provides an effective approach to handling motion artifacts, enabling more accurate and reliable ECG interpretation by medical professionals. We used an ECG simulator that provides body movement simulation as a basis for experiments. The detected ECG signal is processed with a predetermined order IIR filter. We compare the filtered signal to the original signal to measure the effectiveness of reducing motion artifacts. Experimental results show that the applied IIR filter efficiently reduces motion artifacts in the ECG signal. The SNR assessment showed a significant improvement, proving the success of this method in maintaining ECG signal quality. The result is that in the 2nd order, the SNR value is 22.25 dB, in the 4th order the SNR value is 22.75 dB, in the 6th order the SNR value is 22.99 dB, in the 6th order the SNR value is 22.99 dB. 8 obtained an SNR value of 23dB. This study successfully demonstrated that using IIR filters in a specified order effectively reduces motion artifacts in the ECG signal, increases SNR, and maintains the integrity of clinical information in the ECG signal. The implications of this research extend to medical technology development and clinical applications, providing a strong foundation for continued research in more efficient and reliable ECG signal processing.
Implementation Of Entrepreneurship Strategies Based On Digital Marketing For Students' Micro Enterprises In The Surabaya Kemenkes Poltekkes Environment Maghfiroh, Anita Mifthahul; Setiawan, Singgih Yudha; Wakidi, Levana Forra
Frontiers in Community Service and Empowerment Vol. 3 No. 4 (2024): December
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ficse.v3i4.75

Abstract

Entrepreneurship Development Program: Implementation of Digital Marketing-Based Entrepreneurship Strategies for Student Micro Enterprises in the Surabaya Ministry of Health Polytechnic Environment, motivated by the need to increase students' entrepreneurial competence in facing business competition in the digital era. Students who run micro businesses often do not utilize digital marketing strategies optimally. The aim of this program is to equip students with digital marketing skills so that their businesses can develop more effectively. The main contribution of this program is providing training, guidance and business capital to five selected MSMEs, so that students are able to implement digital-based marketing strategies independently. Methods for implementing activities include digital marketing workshops, submitting and selecting business proposals, as well as mentoring for MSMEs that pass the selection. Every MSME is given access and training in using digital platforms such as social media, e-commerce and other digital marketing tools. The program results show that the student MSMEs involved were able to optimize the marketing of their products and services through digital platforms, such as Instagram, YouTube and Shopee. Apart from that, five MSMEs that passed the proposal selection received business capital support and succeeded in increasing visibility and sales through the digital marketing strategy implemented. In conclusion, this program succeeded in increasing students' capacity to manage micro businesses in a more professional and competitive manner. The implication is that the development of digital-based entrepreneurship has the potential to accelerate the growth of student MSMEs and contribute to improving the local economy in the campus environment.
Digital Filter Design to Reduce Motion Artifacts in Electrocardiogram Signals Based on IIR Filter Maghfiroh, Anita Miftahul; Setiawan, Singgih Yudha; Mujahid, Muhammad Umer Farooq
Indonesian Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol. 5 No. 4 (2023): November
Publisher : Jurusan Teknik Elektromedik, Politeknik Kesehatan Kemenkes Surabaya, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijeeemi.v5i4.187

Abstract

Developed a new method to overcome motion artifacts in Electrocardiogram (ECG) signals, which often interfere with accurate clinical analysis. Motion artifacts, such as body movements, can cause significant distortions in the ECG signal, resulting in incorrect interpretation and affecting medical diagnosis. The main objective of this research is to design and implement an infinite impulse response (IIR) filter with a predetermined sequence, namely orders 2, 4, 6, and 8 to reduce motion artifacts in the ECG signal. We aim to improve ECG signal quality by preserving important ECG signal information and reducing noise caused by motion artifacts. This research contributes to developing more precise and reliable ECG signal processing techniques. The proposed method provides an effective approach to handling motion artifacts, enabling more accurate and reliable ECG interpretation by medical professionals. We used an ECG simulator that provides body movement simulation as a basis for experiments. The detected ECG signal is processed with a predetermined order IIR filter. We compare the filtered signal to the original signal to measure the effectiveness of reducing motion artifacts. Experimental results show that the applied IIR filter efficiently reduces motion artifacts in the ECG signal. The SNR assessment showed a significant improvement, proving the success of this method in maintaining ECG signal quality. The result is that in the 2nd order, the SNR value is 22.25 dB, in the 4th order the SNR value is 22.75 dB, in the 6th order the SNR value is 22.99 dB, in the 6th order the SNR value is 22.99 dB. 8 obtained an SNR value of 23dB. This study successfully demonstrated that using IIR filters in a specified order effectively reduces motion artifacts in the ECG signal, increases SNR, and maintains the integrity of clinical information in the ECG signal.
Design of Single Lead Electrocardiography using Filter Order 3 to Reduce Noise Using Spektrum Analysis Based on Fast Fourier Transform Anita Miftahul Maghfiroh; Singgih Yudha Setiawan; Levana Forra Wakidi
International Journal of Advanced Health Science and Technology Vol. 3 No. 3 (2023): June
Publisher : Forum Ilmiah Teknologi dan Ilmu Kesehatan (FORITIKES)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/ijahst.v3i3.227

Abstract

Electrocardiography (EKG) is a method commonly used to measure the performance of the human heart through the heart's electrical activity. To obtain the ECG signal, a lead is carried out using electrodes attached to the skin surface which are recorded in the frequency range 0.05-150Hz. The characteristics of the ECG signal consist of the PR interval, QRS complex and QT interval, from these waveforms doctors can diagnose a disease. However, to get a quality ECG signal, there are often disturbances, such as interference with the 50Hz frequency from electrical grids, respiratory movements, or it could also be caused by the ECG processing algorithm, so it is feared that an error will occur in the diagnosis. From these problems, an appropriate ECG filter is needed to reduce the error rate in generating a wave and maintain signal quality so that it can be accepted clinically. This study aims to design an ECG using a 3rd order filter. The ECG input signal is amplified by an instrument amplifier with 100-fold gain, then a filter process is carried out using a 3rd order Low pass filter to reduce noise interference and then a notch filter is used to ward off the 50Hz network frequency. The results of making a 3rd order filter are able to reduce noise and be able to detect ECG signals properly. It is hoped that this research can be used as a reference for filter design for EKG production and can be utilized in clinical use.
Strategi Digital Marketing dan Edukasi Gizi untuk Daya Saing Wirausaha Mahasiswa di Lingkungan Poltekkes Kemenkes Surabaya Anita Miftahul Maghfiroh; Singgih Yudha Setiawan; Levana Forra Wakidi; Oskar Natan
Jurnal Inovasi Pengabdian dan Pemberdayaan Masyarakat Vol 5 No 2 (2025): JIPPM - Desember 2025
Publisher : CV Firmos

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54082/jippm.974

Abstract

Transformasi digital telah membawa perubahan besar dalam dunia kewirausahaan, terutama di sektor kesehatan dan gaya hidup yang menuntut integrasi teknologi dan nilai gizi. Mahasiswa Poltekkes Kemenkes Surabaya, khususnya dari Jurusan Gizi dan Teknologi Elektromedis, memiliki potensi besar dalam mengembangkan usaha inovatif berbasis edukasi gizi dan digital marketing. Namun, rendahnya literasi gizi dan keterbatasan kompetensi pemasaran digital menjadi tantangan dalam meningkatkan daya saing produk mahasiswa. Kegiatan Pengabdian Kepada Masyarakat (PKM) skema Program Pengembangan Kewirausahaan (PPK) ini bertujuan meningkatkan kemampuan mahasiswa dalam branding produk berbasis nilai gizi serta penguasaan strategi pemasaran digital untuk memperluas jangkauan pasar. Program ini berlangsung selama tiga bulan melalui tiga tahap: survei kebutuhan, pelatihan dengan praktisi gizi RSUD Dr. Soetomo dan konsultan digital marketing, serta pendampingan praktik promosi digital (SEO, content creation, dan marketplace optimization). Hasil menunjukkan peningkatan kompetensi mahasiswa pada tiga aspek utama: pemahaman pelabelan gizi, kemampuan pembuatan konten kreatif, dan jangkauan promosi digital dengan kenaikan rata-rata 20% pengikut media sosial. Kesimpulannya, pelatihan dan pendampingan digital marketing berbasis edukasi gizi terbukti efektif meningkatkan kemampuan branding serta daya saing wirausaha mahasiswa di era ekonomi digital.