STUDI SISTEM PROTEKSI LINE CURRENT DIFFERENTIAL RELAY PADA SALURAN TRANSMISI 150 KV Dharmawan, N. B.; Ariastina, W. G.; Amrita, A. A. N.
Jurnal SPEKTRUM Vol 7 No 1 (2020): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.24843/SPEKTRUM.2020.v07.i01.p22

Abstract

Increasing electricity demand in South Bali requires a reliable electrical system. Reliable electrical systems can be achieved in various ways, one of which is the replacement of high voltage overhead line to high voltage underground cable. The replacement high voltage overhead line to high voltage underground cable requires adjustment of the protection system. The previous main protection system used in high voltage overhead line is distance relay, while the protection system for the new transmission network is line current differential relay. The purpose of this study is to analyze GIS Pesanggaran to GI Nusa Dua transmission line?s protection system. The covered in this analysis is to power flow analysis simulation, 3 phase short circuit simulation, relays setting calculation and testing the relays setting.The power flow simulation showed that the current at peak load from GIS Pesanggaran to GI Nusa Dua is 337 A. The 3 phase short circuit simulation showed that the largest short circuit, if a fault occurs on the GI Nusa Dua of 9.54 kA. The relays setting calcullation showed that of 0,2 A with 20 % slope for Is1 and 2 A with 150% slope for Is2. The results showed that the relays setting has worked properly.
KAJIAN KUAT MEDAN LISTRIK PADA KONFIGURASI HORISONTAL SALURAN TRANSMISI 150 KV I.P.H. Wahyudi; A.A.N. Amrita; W.G. Ariastina
Jurnal SPEKTRUM Vol 2 No 2 (2015): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (230.046 KB)

Abstract

Kajian kuat medan listrik pada konfigurasi horisontal saluran transmisi 150 kV dilakukan untuk menganalisis karakteristik hasil pengukuran kuat medan listrik yang ditimbulkan saluran transmisi. Metode yang digunakan dalam penelitian ini dengan melakukan perhitungan kuat medan listrik dan melakukan pengukuran langsung di lokasi pengukuran. Perhitungan dan pengukuran kuat medan listrik menggunakan 7 titik yang berada di bawah konduktor saluran transmisi 150 kV. Selanjutnya, dilakukan analisis karakteristik hasil perhitungan dan pengukuran kuat medan listrik. Hasil perhitungan kuat medan listrik tertinggi berada di lokasi 3 sebesar 4040 V/m dan hasil pengukuran tertinggi kuat medan listrik terjadi di lokasi 3 sebesar 5387 V/m. Hasil perhitungan dan pengukuran tertinggi di lokasi ini disebabkan oleh jarak konduktor terhadap tanah lebih dekat dari lokasi yang lain. Karakteristik bentuk hasil perhitungan kuat medan listrik dengan jarak yang sama dari pusat titik perhitungan sama, disebabkan tegangan masing-masing fase tetap. Karakteristik hasil pengukuran kuat medan listrik pada masing-masing titik pengukuran berbeda. Perbedaan karakteristik tersebut disebabkan oleh waktu pengukuran kuat medan listrik di masing-masing titik pengukuran berbeda, sehingga tegangan pada masing-masing fase berubah-ubah.
STUDI INTENSITAS MEDAN LISTRIK SUTT 150 KV KONFIGURASI HORIZONTAL UNTUK LINGKUNGAN PEMUKIMAN I.G.N. Adi Kurniawan; A.A.N. Amrita
Jurnal SPEKTRUM Vol 2 No 4 (2015): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (590.394 KB)

Abstract

Tegangan pada kawat penghantar SUTT akan membangkitkan medan listrik di sekitar kawat penhantar SUTT tersebut. Paparan intensitas medan listrik yang diijinkan oleh SNI terhadap manusia yang berada di sekitarnya yaitu tidak boleh melebihi 5 kV untuk pemaparan dalam jangka waktu 24 jam. Studi intensitas medan listrik SUTT 150 kV konfigurasi horizontal untuk lingkungan pemukiman dilakukan untuk menganalisa intensitas medan listrik di sepanjang saluran transmisi berdasarkan tinggi konduktor ke permukaan tanah yang nantinya akan dibangun sebagai rumah tinggal. Metode yang digunakan dalam penelitian ini adalah dengan melakukan pengukuran tinggi konduktor ke permukaan tanah di sepanjang saluran antara dua tiang transmisi. Hasil pengukuran tinggi konduktor dijadikan dasar untuk menghitung dan menganalisa intensitas medan listrik di sepanjang saluran transmisi 150 kV. Berdasarkan hasil perhitungan yang mengacu pada standar SNI, pembangunan rumah dengan ketinggian lantai 3 meter di atas permukaan tanah dengan asumsi ketinggian manusia tertinggi yang berdiri diatasnya adalah 2 meter hanya boleh di bangun di titik perhitungan A,B,C,G,H dan I atau jarak 0,10,20,60,70 dan 80 meter dari tiang, sedangkan pembangunan rumah dengan ketinggian lantai 4 meter di atas permukaan tanah dapat dibangun di titik A dan I saja. Pembangunan rumah dengan ketinggian lantai 1 sampai dengan 2 meter dari permukaan tanah dapat dibangun di semua titik perhitungan. Hasil dari perhitungan intensitas medan listrik tersebut akan dijadikan sebagai rekomendasi untuk pembangunan rumah tinggal di bawah saluran transmisi 150 kV.
STUDI PENGARUH UPRATING SALURAN TRANSMISI TEGANGAN TINGGI 150 kV TERHADAP SETTING RELE JARAK ANTARA GI KAPAL – GI PADANG SAMBIAN – GI PESANGGARAN S.K. Supriana; I.G. Dyana Arjana; A.A.N. Amrita
Jurnal SPEKTRUM Vol 1 No 1 (2014): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (338.65 KB)

Abstract

Uprating saluran transmisi pada penelitian ini merupakan pembesaran penampang yang sebelumnya ACSR 240 mm2 menjadi ACCC Lisbon 300 mm2. Adanya uprating saluran transmisi menyebabkan perubahan nilai impedansi. Penelitian ini bertujuan untuk mendapatkan nilai setting rele jarak yang sesuai dengan impedansi zone reach setelah dilakukan uprating SUTT 150 kV. Hasil perhitungan diperoleh nilai setting rele jarak setelah dilakukan uprating yaitu zone pengaman Kapal – Padang Sambian nilai setting rele jaraknya sebesar zone 1 : 1,428 ? (122%), zone 2 : 2,240 ? (197%), zone 3 : 3,640 ? (361%), dan zone 3 reverse : 0,385 ?. Zone pengaman Padang Sambian – Pesanggaran nilainya zone 1 : 1,040 ? (133), zone 2 : 3,300 ? (142%), zone 3 : 6,160 ? (259%), dan zone 3 reverse : 0,302 ?.
RANCANG BANGUN SISTEM MONITORING LAMPU PENERANGAN JALAN UMUM BERBASIS WEB Putu Vendi Arya Wibawa; Komang Oka Saputra; Anak Agung Ngurah Amrita
Jurnal SPEKTRUM Vol 6 No 4 (2019): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (395.476 KB) | DOI: 10.24843/SPEKTRUM.2019.v06.i04.p8

Abstract

Beberapa masalah yang terjadi pada lampu penerangan jalan umum kadang kala terabaikan, karena tidak ada laporan atau pengecekan yang rutin dilakukan, hal ini bisa sangat membahayakan pengguna jalan umum terutama pada malam hari. Dalam penelitian ini dibuatkan rancangan sistem monitoring lampu penerangan jalan umum berbasis web. Perancangan sistem monitoring dibagi menjadi dua metode yaitu perancangan perangkat keras dan perancangan web. Untuk perangkat keras ditambahkan modul Wifi ESP8266 sebagai media pengiriman data ke web, perancangan web yang digunakan yaitu memanfaatkan Sistem Informasi Geografis (SIG) untuk mengetahui lokasi LPJU. Pada SIG ada mark yang berisi informasi tentang lokasi alat monitoring dan informasi tentang data nilai-nilai pada sensor. Apabila terjadi gangguan pada lampu penerangan jalan umum seperti lampu mati dan kabel terputus, akan ada penurunan nilai pada sensor, jika nilai sensor yang dibaca di bawah dari yang sudah di tentukan maka mark yang ada pada map web monitoring akan berganti, menandakan terjadinya gangguan pada lampu penerangan jalan umum.
PENENTUAN KONDISI TRANSFORMATOR BERDASARKAN KANDUNGAN GAS TERLARUT MENGGUNAKAN METODE SEGITIGA DUVAL I M.T. Sismantara; W.G. Ariastina; A.A.N. Amrita
Jurnal SPEKTRUM Vol 8 No 1 (2021): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (571.075 KB) | DOI: 10.24843/SPEKTRUM.2021.v08.i01.p12

Abstract

Transformer failure may interrupt the electrical power delivery and causing a very highcost to the utility. In order to prevent failure in the transformer, continuous condition monitoringof a power transformer is necessary. Dissolved Gas Analysis (DGA) has been well knownmethod for transformer condition monitoring. A number of techniques have been developed inorder to assist engineers in interpreting the DGA test results. In this research, interpretation ofDGA test results using Fuzzy Logic approach based on Duval's Triangle is introduced. TheFuzzy Logic was developed based on the mapping of the different areas within the DuvalTriangle. The program validation was carried out by comparing the output program with thesimulated fault condition. The analysis results indicated that the introduced approach hassuccessfully determined the condition of the tested transformers. This approach, thus, wouldprovide advantages over the conventional method in determining the transformer condition.
STUDI SISTEM PROTEKSI LINE CURRENT DIFFERENTIAL RELAY PADA SALURAN TRANSMISI 150 KV N. B. Dharmawan; W. G. Ariastina; A. A. N. Amrita
Jurnal SPEKTRUM Vol 7 No 1 (2020): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (498.812 KB) | DOI: 10.24843/SPEKTRUM.2020.v07.i01.p22

Abstract

Increasing electricity demand in South Bali requires a reliable electrical system. Reliableelectrical systems can be achieved in various ways, one of which is the replacement of highvoltage overhead line to high voltage underground cable. The replacement high voltageoverhead line to high voltage underground cable requires adjustment of the protection system.The previous main protection system used in high voltage overhead line is distance relay, whilethe protection system for the new transmission network is line current differential relay. Thepurpose of this study is to analyze GIS Pesanggaran to GI Nusa Dua transmission line’sprotection system. The covered in this analysis is to power flow analysis simulation, 3 phaseshort circuit simulation, relays setting calculation and testing the relays setting.The power flowsimulation showed that the current at peak load from GIS Pesanggaran to GI Nusa Dua is 337A. The 3 phase short circuit simulation showed that the largest short circuit, if a fault occurs onthe GI Nusa Dua of 9.54 kA. The relays setting calcullation showed that of 0,2 A with 20 %slope for Is1 and 2 A with 150% slope for Is2. The results showed that the relays setting hasworked properly.
STUDI INTENSITAS MEDAN LISTRIK DI SUTT 150 kV KONFIGURASI VERTIKAL UNTUK LINGKUNGAN PEMUKIMAN I.N.Y. Prayoga; A.A.N. Amrita; C.G.I. Partha
Jurnal SPEKTRUM Vol 2 No 4 (2015): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (386.209 KB)

Abstract

Rekomendasi pembangunan rumah yang aman di bawah SUTT 150 kV konfigurasi vertikal dibutuhkan untuk menghindari paparan medan listrik yang dapat menyebabkan gangguan kesehatan manusia sesuai dengan standar yang telah ditetapkan oleh SNI dan WHO yaitu sebesar 5 Kv/m. Perhitungan kuat medan listrik pada 9 titik di bawah SUTT 150 kV konfigurasi vertikal menunjukkan kuat medan listrik tertinggi berada pada andongan terendah diantara 2 tiang SUTT. Rekomendasi pembangunan rumah pada andongan terendah sampai ketinggian lantai 4 meter dari permukaan tanah dengan intensitas medan listrik sebesar 4,75 kV/m. Intensitas medan listrik terendah berada tepat di bawah tiang SUTT dan direkomendasikan pembangunan rumah sampai ketinggian lantai 7 meter dari permukaan tanah dengan intensitas medan listrik sebesar 4,95 kV/m.
PERAMALAN BEBAN LISTRIK JANGKA PENDEK MENGGUNAKAN METODE ADAPTIVE NEURO FUZZY INFERENCE SYSTEM (ANFIS) DI GARDU INDUK NUSA DUA BALI I Made Satriawan; I Made Mataram; A. A. Ngurah Amrita
Jurnal SPEKTRUM Vol 7 No 1 (2020): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (396.46 KB) | DOI: 10.24843/SPEKTRUM.2020.v07.i01.p12

Abstract

Electric load in Nusa Dua Bali has increased from 2013-2017 by an average of 11.83%. The increase in electric load requires the electrical energy service provider to be able to adjust the electricity demand and be able to increase its reliability, The effort that can be done is to predict the electric load. Electric load forecasting can be done by various methods, ANFISo (Adaptiveo Neuroo Fuzzyo Inferenceo Systemo) is one method that is often used in forecasting electrical loads. ANFIS is able to explain the reasoning process and do data learning. The data used are the electric load, temperature, humidity and time, the data was chosen because changes in temperature and humidity affect people's habitual patterns in using air conditioners (electric load patterns). The electric load pattern is trained 100 times using ANFIS with the type of membership function is trimf, and [3 3 3 3] is the number of membership function. The indicator to determining the accuracy of the electrical load forecasting pattern results with the real electric load pattern used the MAPE (Mean Absolute Percentage Error) value, which the MAPE standard value that good is less than 10%. The test results from this study produced a MAPE value of 6.98%.
Studi Tegangan Tembus Minyak Transformator I Nyoman Oksa Winanta; Anak Agung Ngurah Amrita; Wayan Gede Ariastina
Jurnal SPEKTRUM Vol 6 No 3 (2019): Jurnal SPEKTRUM
Publisher : Program Studi Teknik Elektro UNUD

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (209.806 KB) | DOI: 10.24843/SPEKTRUM.2019.v06.i03.p02

Abstract

This study aims to identify the effect of changes in temperature, water content, andelectrode gap on the breakdown voltage of transformer oil. The transformer oil used in this studywas Shell Diala-B and Nynas oil. Testing the effect of temperature was carried out attemperature variation of 280 C to 810 C, the effect of water content was carried out withvariations ranging from 11 ppm to 31 ppm, and the effect of electrode gap was carried out invariation ranges between 1.2 mm to 2.5 mm. Breakdown voltage testing method useshemispherical electrodes according to IEC 60156 standard of 1995. The results of the studyshow that the higher the temperature, the higher the breakdown voltage of transformer oil. Thehighest breakdown voltage in Nynas oil occurs when the temperature is 810 C which is equal to59.27 kV. The results also show that the higher the water content, the breakdown voltage islower. The highest breakdown voltage in Shell Diala-B oil occurs with a water content of 11 ppmwhich is equal to 61.35 kV. Also the greater the electrode gap, the greater the breakdownvoltage. The highest breakdown voltage in Nynas oil occurs with the gap of electrode 2.5 mmwhich is equal to 60.02 kV.