Claim Missing Document
Check
Articles

Found 25 Documents
Search

Analysis of the Electric Power Distribution System Service Reliability Index at PLN Lancang Garam Aslami, Muhammad Mirdasil; Sadrina, Sadrina; Fachri, Muhammad Rizal
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 4 No. 2 (2024): October Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v4i2.8567

Abstract

The level of electrical energy demand in an area reflects the welfare of that community. The greater the use of electrical energy, the higher the community's standard of living, followed by the public's critical attitude towards everything that happens and influences lives, including electricity services. Generally, a network's reliability level can be seen from the size of the SAIDI and SAIFI values on the PLN (state electricity company) side. The calculation and reliability analysis results of the Lhokseumawe ULP above show that the total SAIFI index value is 2.68 times/year. The SAIFI Rayon Lhokseumawe reliability index is categorized as reliable because its value does not exceed the standard set by PLN in SPLN 68-2 of 1986, namely 3.2 times/year. The total value of the SAIDI index is 45.30 hours/year. The Lhokseumawe Rayon SAIDI reliability index is categorized as unreliable because its value exceeds the standard set by PLN in SPLN 68-2 of 1986, namely 21 hours/year. There are certainly differences in infrastructure, electrical equipment, and number of customers in 1986 compared to current years; this has a different influence on electricity reliability values such as SAIDI and SAIFI.
Vocational High School 5 Telkom Banda Aceh's Occupational Safety and Health Module Design Sari, Hasna; Fachri, Muhammad Rizal; Islamadina, Raihan
Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro Vol. 8 No. 1 (2024)
Publisher : PTE FTK UIN Ar-Raniry

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22373/crc.v8i1.20800

Abstract

In educational institutions, occupational safety and health are significant issues. Students and institutions may suffer losses as a result of accidents and issues with occupational health. Thus, it's critical that pupils have comprehensive understanding of K3. SMK Negeri 5 Telkom Banda Aceh observations revealed a deficiency in instructional resources for K3 instruction. Therefore, the goal of the research is to use the ADDIE model (Analysis, Design, Development, Implementation, and Evaluation) in conjunction with the Research and Development (R&D) technique to design an Occupational Safety and Health Module. Student response questionnaires, validation questionnaires from media experts, and material experts were used in the data collection process. According to the research findings, 92.5% of material experts and 77.5% of media experts believe that the K3 module is adequate from a media standpoint. Student responses also attain a score of 92.4%, suggesting that the K3 module is appropriate for use in education. In summary, the K3 module has emerged as a highly successful educational tool for maximizing students' engagement with K3.
The Think Pair Share Learning Model's Active Learning Process in Basic Electrical Subjects at SMKN 1 Lhoknga, Aceh Azmi, Faisal; Fathiah, Fathiah; Fachri, Muhammad Rizal
Circuit: Jurnal Ilmiah Pendidikan Teknik Elektro Vol. 8 No. 2 (2024)
Publisher : PTE FTK UIN Ar-Raniry

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.22373/crc.v8i2.22089

Abstract

Vocational high school curriculum aimed to prepare pupils for careers in specific industries. Student learning results are significantly impacted by the vocational school learning process. Students' comprehension at SMKN 1 Lhoknga is still deficient since the learning model used is not as effective in maximizing the growth of students' understanding. Applying the Think Pair Share learning paradigm, which is in line with the learner-centered curriculum, is one option to solve this issue. This study employs a quantitative methodology and involved 27 pupils in class X TITL SMKN 1 Lhoknga. Questionnaires and observation sheets are the tools employed. The findings demonstrated that, according to the Think Pair Share learning model, students' average level of activity was 79, with a trend of 79 > 73.3, placing them in the very high category. The percentage of students who responded is 77.04%. it can be concluded that the utilization of the Think Pair Share approach can raise students' engagement with basic electrical materials, according to the study's findings. 
Rancang Bangun Blower Otomatis Berbasis Sensor DHT11 untuk Efisiensi Pembakaran Gula Merah Asrizal, Asrizal; Muhammad Rizal Fachri
Aceh Journal of Electrical Engineering and Technology Vol. 5 No. 2 (2025): Desember 2025
Publisher : Program Studi Teknik Elektro Fakultas Teknik Universitas Iskandarmuda Jl. Kampus Unida No.15, Surien, Kec. Meuraxa, Kota Banda Aceh, Aceh 23234 Propinsi Aceh, Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55616/ajeetech.v5i2.1057

Abstract

Pada proses produksi gula merah secara tradisional, pembakaran yang kurang efisien sering menyebabkan konsumsi kayu bakar berlebih dan waktu pemasakan yang lama. Penelitian ini bertujuan merancang dan membangun sistem blower otomatis yang dapat mengoptimalkan pembakaran menggunakan sensor suhu DHT11, Arduino Uno, dan relay. Blower bekerja secara otomatis berdasarkan pembacaan suhu secara real-time, memberikan suplai udara yang konsisten untuk meningkatkan efisiensi pembakaran. Hasil pengujian menunjukkan sistem mampu mengurangi konsumsi kayu bakar sebesar 20% dan waktu pemasakan sebesar 20% dibandingkan metode manual. Akurasi sensor DHT11 mencapai 99,386% dengan rata-rata tingkat kesalahan hanya 0,614%. Penerapan sistem ini memberikan manfaat praktis bagi pabrik gula merah skala kecil, seperti menurunkan biaya operasional, meningkatkan efisiensi energi, dan memperbaiki kualitas produk.
Analysis of the Electric Power Distribution System Service Reliability Index at PLN Lancang Garam Aslami, Muhammad Mirdasil; Sadrina, Sadrina; Fachri, Muhammad Rizal
JURNAL EDUNITRO Jurnal Pendidikan Teknik Elektro Vol. 4 No. 2 (2024): October Issue
Publisher : Department of Electrical Engineering Education, Faculty of Engineering, State University of Manado

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.53682/edunitro.v4i2.8567

Abstract

The level of electrical energy demand in an area reflects the welfare of that community The greater the use of electrical energy the higher the community s standard of living followed by the public s critical attitude towards everything that happens and influences lives including electricity services Generally a network s reliability level can be seen from the size of the SAIDI and SAIFI values on the PLN state electricity company side The calculation and reliability analysis results of the Lhokseumawe ULP above show that the total SAIFI index value is 2 68 times year The SAIFI Rayon Lhokseumawe reliability index is categorized as reliable because its value does not exceed the standard set by PLN in SPLN 68 2 of 1986 namely 3 2 times year The total value of the SAIDI index is 45 30 hours year The Lhokseumawe Rayon SAIDI reliability index is categorized as unreliable because its value exceeds the standard set by PLN in SPLN 68 2 of 1986 namely 21 hours year There are certainly differences in infrastructure electrical equipment and number of customers in 1986 compared to current years; this has a different influence on electricity reliability values such as SAIDI and SAIFI < p>