Claim Missing Document
Check
Articles

Found 10 Documents
Search
Journal : Civil Engineering Scientific Journal

KAJIAN KARAKTERISTIK GELOMBANG PECAH DI PANTAI TEMPAT PELELANGAN IKAN (TPI) PULAU BUNYU, KABUPATEN BULUNGAN Rini, Detya Nurfajar; Utomo, Edy; Hermansyah, Muhammad
Civil Engineering Scientific Journal Vol 1, No 1 (2022): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1407.27 KB) | DOI: 10.35334/cesj.v1i1.2891

Abstract

ABSTRACT: Pulau Bunyu is a district in Bulungan Regency, North Kalimantan Province. TPI (Fish Auction Place) Beach is one of beaches found in Pulau Bunyu. TPI beach is an area frequently visited by many people for recreation. However, people said that a lot of sand has been eroded by the sea water. Thus, it is necessary to have information related to the characteristics of waves by studying the characteristics of breaking waves. Wave forecast was made by the calculation using a deep wave hindcasting method based on the wind data within a period of 10 years from the BMKG Tarakan station to obtain the period and wave height. From the calculation results, the waves at TPI Beach in Pulau Bunyu district were dominated by the eastward waves with the maximum wind speed occurring in March 2020 with H = 2.765 m and T = 6.880 s, Kr = 0.9404 – 1.0023 and Ks = 0.913 – 1.244, Hb = 2.2 m, db = 0.4, and Angle = 17.2°. The dominant wind wave had H = 0.700 m and T = 4.197 s, Kr = 0.8244–1.0545, and Ks = 0.914-1.270, Hb = 0.7 meter, db = 0.2 m, and Angle = 28°. The Average wave had H = 0.720 m and T = 4.391 s, Kr = 0.919-0.9998 and Ks = 0.914-1.27, Hb = 0.74 meter, db = 0.2 m, and Angle = 19°. These were waves damaging the beach because the wave height was more than 1.00 meter. This event only occurred at the maximum wind conditions. Meanwhile, the frequent and average winds, the waves were constructive or not damaging the beach because the wave height was than 1.00 meter.Keywords: Breaking waves, hindcasting, Pulau Bunyu TPI Beach, wave characteristics.ABSTRAK: Pulau Bunyu adalah sebuah kecamatan di Kabupaten Bulungan, Provinsi Kalimantan Utara. Pantai TPI (Tempat Pelelangan Ikan) salah satu pantai di Pulau Bunyu yang  terletak di Desa Bunyu Selatan. Pantai TPI merupakan kawasan yang sering di datangi oleh penduduk untuk melakukan rekreasi. Menurut warga banyak pasir-pasir yang tergerus air laut. Maka perlu adanya informasi tentang karakteristik gelombang pada daerah tersebut yang dapat merusak pantai, salah satunya adalah dengan kajian karakteristik gelombang pecah. Peramalan gelombang di lakukan dengan perhitungan menggunakan metode hindcasting gelombang berdasarkan data angin kurun waktu 10 tahun dari stasiun BMKG Tarakan untuk mendapatkan periode dan tinggi gelombang. Dari hasil perhitungan gelombang di Pantai TPI Pulau Bunyu di dominasi oleh gelombang arah Timur dengan kecepatan angin maksimum terjadi pada bulan Maret 2020 dengan H = 2,765 m dan T= 6,880 det, Kr = 0,9404 – 1,0023 dan Ks = 0,913 – 1,244, Hb = 2,2 m, db = 0,4 dan Sudut = 17,2°. Pada gelombang angin dominan dengan H = 0,700 m dan T = 4,197 det, Kr = 0,8244-1,0545 dan Ks = 0,914-1,270 , Hb = 0,7 meter, db = 0,2 m dan Sudut = 28°. Pada Gelombang Rata-Rata dengan H = 0,720 m dan T = 4,391 det, Kr = 0,9190-0,9998 dan Ks = 0,914-1,270 , Hb = 0,74 meter, db = 0,2 m dan Sudut  = 19°. Pada kondisi angin maksimum gelombang ini termasuk gelombang yang merusak pantai karena tinggi gelombang lebih dari 1.00 meter, sedangkan pada kondisi besaran angin yang sering terjadi dan rata-rata, gelombang tidak merusak pantai.Kata Kunci : Gelombang Pecah, hindcasting, karateristik gelombang, Pantai TPI Pulau Bunyu 
KOMPARASI BAJA KONVENSIONAL DAN BAJA KOMPOSIT SANDWICH PANEL SEBAGAI MATERIAL PELAT LANTAI JEMBATAN PENYEBERANGAN Zulhimantara, Audana; Utomo, Edy
Civil Engineering Scientific Journal Vol 1, No 2 (2022): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (837.374 KB) | DOI: 10.35334/cesj.v1i2.3361

Abstract

ABSTRACT: Floor plate is one of the main parts of civil building structures both buildings and bridges. Sandwich panel is a composite materials of synthetic resin and steel plate. Where the density of Sandwich panel is lighter than conventional steel and has greater flexural strength. Yet, it has never been done before in the realm of civil engineering, so further analysis is needed to obtain optimal result. The used of Sandwich panel with dimensions of 4-10-4 mm changes the beam structure on the pedestrian bridge. The horizontal beam profile used was WF450.200.9.14 with a maximum span of 2 meters and the distance between the beams was 2.6 meters. The vertical beam profile used was WF250.250.9.14 with a span of 2.6 meters and the distance between the beams was 2 meters. The column profile used was WF440.300.11.18 with a height of 5.4 meters. The comparison of the maximum stress values that occur in steel floor plates was 5.227 MPa and the one using a Sandwich panel was 32.271 MPa. The deformation values that occur in steel floor plates was 23.048 mm and the one using a Sandwich panel was 26.517 mm. The comparison of the total weight values that occur in steel floor plates was 22.005 tons and the one using Sandwich panel was 20.590 tons.Keywords: sandwich panel, steel plate, n method, pedestrian bridge ABSTRAK: Plat lantai adalah salah satu bagian utama dari struktur bangunan sipil baik gedung maupun jembatan. Plat lantai sendiri mendistribusikan beban ke balok anak dan balok induk. Sandwich panel adalah material komposit antara synthetic resin dengan plat baja. Dimana densitas sandwich panel lebih ringan dari pada baja konvensional serta memiliki kuat lentur yang lebih besar. Penggunaan sandwich panel dengan dimensi 4-10-4 mm memberikan perubahan struktur balok pada jembatan penyeberangan. Profil balok arah horizontal yang digunakan adalah WF450.200.9.14 dengan bentang maksimal 2 meter dan jarak antar balok adalah 2,6 meter. Profil balok arah vertikal yang digunakan adalah WF250.250.9.14 dengan bentang 2,6 meter dan jarak antar balok adalah 2 meter. Profil kolom yang digunakan adalah WF440.300.11.18 dengan tinggi 5,4 meter. Perbandingan nilai tegangan maksimum yang terjadi pada plat lantai baja adalah sebesar 5,227 Mpa, sedangkan sandwich panel sebesar 32,271 MPa. Nilai deformasi yang terjadi pada plat lantai baja adalah sebesar 23,048 mm dan yang menggunakan sandwich panel sebesar 26,517. Perbandingan nilai berat total yang terjadi pada plat lantai baja adalah sebesar 22,005 Ton dan yang menggunakan sandwich panel sebesar 20,590 Ton.Kata kunci: sandwich panel, plat baja, metode n, tegangan
ANALISIS KUAT TEKAN BETON POROUS DENGAN PERBANDINGAN NILAI FAKTOR AIR SEMEN (FAS) Manan, Muhammad Alfarizi; Utomo, Edy
Civil Engineering Scientific Journal Vol 1, No 1 (2022): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (497.401 KB) | DOI: 10.35334/cesj.v1i1.2887

Abstract

ABSTRACT: As time goes by, the construction world continues to develop, one of which is the innovation of concrete technology with the discovery of concrete that can pass water from the concrete cavity, known as porous concrete. This study aims to determine the characteristics of porous concrete including bulk density, absorption, and compressive strength. The test variables used were A on FAS 0;48, B on FAS 0;53, C on FAS 0;58, and D on FAS 0;64. To obtain good porosity in porous concrete, only 3 aggregate sizes were used which are uniform with the use of cement as much as 1 of 6 weight of aggregate, while the consistency of the paste (cement water) followed the specified FAS value. The total number of test objects was 120 samples with each variable as many as 30 samples and the test was carried out when the test object is 28 days old. The results of this study were statistically tested using a normal distribution to obtain a bulk density value of 1.64 gram/cm3 at FAS 0;48, 1.66 gram/cm3 at FAS 0;53, 1.67 gram/cm3 at FAS. 0;58, and 1.69 gram/cm3 at 0;64 FAS. The absorption value was 1.88% at FAS 0;48, 1.94% at FAS 0;53, 2.17% at FAS 0;58, and 1.82% at FAS 0:64. The compressive strength values were 4.4 MPa at 0;48 FAS, 5.5 MPa at 0;53 FAS, 5.8 MPa at 0;58 FAS, and 3.6 MPa at 0;64 FAS. However, it should be noted that the variable D (FAS 0.64) did not meet the requirements for the appearance/physical properties of porous concrete due to the use of excess water which made the surface of the concrete cover. Keywords: Porous Concrete, Bulk Density, Absorption, Compressive Strength ABSTRAK: Seiring berjalannya waktu dunia konstruksi terus berkembang salah satunya dalam inovasi teknologi beton dengan ditemukannya beton yang dapat meloloskan air dari rongga beton tersebut yang dikenal dengan istilah beton porous. Penelitian ini bertujuan untuk mengetahui nilai karakteristik beton porous meliputi berat isi, penyerapan, dan kuat tekan. Variabel pengujian yang digunakan ialah A pada FAS 0;48, B pada FAS 0;53, C pada FAS 0;58, dan D pada FAS 0;64. Demi memperoleh porositas yang baik pada beton porous maka agregat yang digunakan hanya 3 ukuran agregat yang seragam dengan penggunaan semen sebanyak 1 dari 6 berat agregat sedangkan konsistensi pasta (semen air) mengikuti nilai FAS yang ditetapkan. Total jumlah benda uji sebanyak 120 sampel dengan setiap variabelnya masing-masing sebanyak 30 sampel dan pengujian dilakukan pada saat benda uji berumur 28 hari. Hasil dari penelitian ini diuji secara statistik menggunakan distribusi normal hingga memperoleh nilai berat isi 1,64 gram/cm3 pada FAS 0;48, 1,66 gram/cm3 pada FAS 0;53, 1,67 gram/cm3 pada FAS 0;58, dan 1,69 gram/cm3 pada FAS 0;64. Nilai penyerapan 1,88% pada FAS 0;48, 1,94% pada FAS 0;53, 2,17% pada FAS 0;58, dan 1,82% pada FAS 0;64. Nilai kuat tekan 4,4 MPa pada FAS 0;48, 5,5 MPa pada FAS 0;53, 5,8 MPa pada FAS 0;58, dan 3,6 Mpa pada FAS 0;64. Namun perlu diketahui bahwa pada variabel D (FAS 0,64) tidak memenuhi ketentuan sifat tampak/fisik dari beton porous dikarenakan pengunaan air yang berlebih membuat permukaan beton menjadi tertutup. Kata kunci: Beton Porous, Berat Isi, Penyerapan, Kuat Tekan
STUDI PERUBAHAN TINGGI GELOMBANG LAUT UNTUK RENCANA PENGEMBANGAN INFRASTRUKTUR PELABUHAN DI PANTAI BARAT PULAU TARAKAN KALIMANTAN UTARA Utomo, Edy; Asta, Asta
Civil Engineering Scientific Journal Vol 2, No 3 (2023): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v2i3.4215

Abstract

ABSTRACT: Tarakan City has long been a supporting area for the social, cultural and economic life of the North Kalimantan Province, because of its strategic location, especially on the west side of the coast which is used for port infrastructure. Currently climatological conditions are experiencing changes resulting from global warming. An increase the height of the sea waves, because one of the wave generators in the ocean is wind. In this study, it tries to determine changes in wave height and its transformation to the water area of the Port, by utilizing wind speed and direction data sourced from ECMWF. The method used is a quantitative research method by applying the SPM Method, for forecasting wave generation and long-term wave prediction using the Weibull Method, as a reference for wave transformation for the next 100 years. The results of the prediction of wave height in the waters of the West Coast Port of Tarakan Island for the next 100 years are still within safe limits, as long as the wave height that occurs is less than 0,34 meters. Based on these results, it can be concluded that Port Infrastructure can still operate for the next 100 years, as a support for the social, cultural and economic life of the people in North Kalimantan Province. Keywords: ECMWF, Port, Tarakan, Wave, Wind ABSTRAK: Kota Tarakan telah sejak lama menjadi bagian wilayah penopang kehidupan sosial, budaya, dan perekonomian Provinsi Kalimantan Utara, karena letaknya yang strategis terutama pada sisi barat pantainya yang digunakan untuk infrastruktur Pelabuhan. Saat ini kondisi klimatologi mengalami perubahan yang diakibatkan dari pemanasan global. Peningkatan temperatur mengakibatkan perubahan pada hembusan angin yang akan berdampak pada peningkatan ketinggian gelombang laut, karena salah satu pembangkit gelombang di lautan adalah angin. Pada penelitian ini mencoba untuk mengetahui perubahan tinggi gelombang beserta transformasinya sampai ke wilayah perairan Pelabuhan, dengan memanfaatkan data kecepatan dan arah angin yang bersumber dari ECMWF. Metode yang digunakan adalah metode penelitian kuantitatif dengan menerapkan Metode SPM, untuk peramalan pembangkitan gelombang dan prediksi gelombang jangka panjang menggunakan Metode Weibull, sebagai acuan transformasi gelombang untuk 100 tahun yang akan datang. Hasil prediksi tinggi gelombang di daerah perairan Pelabuhan pantai barat Pulau Tarakan untuk 100 tahun kedepan masih dalam batas aman, selama tinggi gelombang yang terjadi kurang dari 0,34 meter. Berdasarkan hasil tersebut, maka dapat disimpulkan bahwa Infrastruktur Pelabuhan-pelabuhan masih dapat beroperasi untuk 100 tahun yang akan datang, sebagai penopang kehidupan sosial, budaya, dan perekonomian masyarakat di Provinsi Kalimantan Utara.Kata kunci: Angin, ECMWF, Gelombang, Pelabuhan, Tarakan
STUDI DAERAH RAWAN LONGSOR PADA KAWASAN PEMUKIMAN KAMPUNG BUGIS KOTA TARAKAN DENGAN PENERAPAN METODE FOTOGRAMETRI Utomo, Edy; Syarif, Iif Ahmad; Barocah, Alfika Henny; Reni, Reni; Sadam, Muhammad Saipul
Civil Engineering Scientific Journal Vol 2, No 1 (2023): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v2i1.3392

Abstract

ABSTRACT: Landslides are events due to changes in land use in the steep slope classification. The slope of the land can be identified by extracting elevation data from the earth’s surface. One way of measurement is to apply the photogrammetric method. In this research, a study was conducted on landslide-prone areas in the residential area of the Kampung Bugis Tarakan City, with a base map that was the results of processing UAV aerial photographs. The results of the study state that the photogrammetric method of aerial photographs of UAVs is able to provide an accuracy rate of 98%, and is able to provide an overview of landslide prone maps with a precision of 90%. Applying this method, the researchers found that the study area is at high risk of landslides, with a potential vulnerability level of 43,61% high and 36,33% very high, which were spread over hillside areas in an area of 72,70 hectare. Keywords: Elevation, Photogrammetric, Landslide, Tarakan, UAV.ABSTRAK: Tanah longsor merupakan kejadian akibat perubahan guna lahan pada klasifikasi kelerengan yang curam. Kelerengan lahan dapat diidentifikasi dengan ekstraksi data elevasi dari permukaan bumi. Salah satu cara pengukurannya adalah dengan menerapkan metode fotogrametri. Pada penelitian ini dilakukan studi daerah rawan longsor di wilayah pemukiman kampung bugis Kota Tarakan dengan peta dasar merupakan hasil dari pengolahan foto udara UAV. Hasil studi menyatakan bahwa metode fotogrametri dari foto udara UAV mampu memberikan tingkat akurasi 98%, dan mampu memberikan gambaran peta rawan longsor dengan ketelitian 90%. Dari penerapan metode ini, dinyatakan bahwa lokasi penelitian merupakan daerah rawan longsor dengan potensi tingkat kerawanan 43,61% tinggi dan 36,33% sangat tinggi, yang tersebar pada daerah lereng perbukitan pada luas lokasi penelitian sebesar 72,70 hektar.Kata kunci: Elevasi, Fotogrametri, Longsor, Tarakan, UAV.
KAJIAN KARAKTERISTIK GELOMBANG PECAH DI PANTAI AMAL BARU KOTA TARAKAN Kahtijah, Siti; Utomo, Edy; Hermansyah, Muhammad
Civil Engineering Scientific Journal Vol 1, No 1 (2022): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1123.405 KB) | DOI: 10.35334/cesj.v1i1.2896

Abstract

ABSTRACT: Amal Baru beach is a coastline that has great potential as a tourist area. Based on direct observation, it has been undertaking a lot of physical changes (damage) in the coastal area. This damage is caused by coastal dynamics processes such as heavy abrasion which has caused a bad impact and raises concerns for a coastal residents. Consequently, it is necessary to have knowledge on the characteristics of the waves occured on the coastline in the development and security of coastal areas and the protection of the sorrounding community. In the study analysis was conducted by using Airy Theory, the data analysis approach employed the airstream data from BMKG Juwata Tarakan. The result of the analysis of wave transformation for 10 years (2010-2019) at Amal Baru Beach obtainend the dominant wind direction from east to west; the fetch length is 224,589 m; breaking wave height ranges from 0.8 m - 2.4 m and breaking wave depth range from 0.38 m - 2.1 m. Ased on the results of analysis, at maximum wind conditions, average winds, and highly occured winds; the speeds of land breeze blowing beetwen 3.5 m/s - 15 m/s, sea wind speeds blowing beetwen 5 m/s - 19 m/s, Wind waves Forecasting Significant height (H) beetwen 0.9 m - 4.8 m, Period (T) beetwen 5.5 s - 10.2 s, Duration (D) beetwen 9 hours - 11 hours. Thus, the result of Analysis for Wave Height (H) is beetwen 0.8 m - 2.8 m, the Depth of Breaking Wave (Hb) is beetwen 0.3 m - 2.1 m, and the angle of incidence of the wave is 8° - 30°. Therefore, it concluded that the wave height generated during the maximum wind speed conditions and hightly occured wind speed is a destructive wave (waves which damage the coastline).Keywords: breaking waves, hindcasting, wave characteristics, Pantai amal baru, refraction, shoaling.ABSTRAK: Kerusakan yang terjadi di Pantai Amal Kota Tarakan diakibatkan oleh proses dinamika pantai seperti abrasi sangat yang berdampak buruk serta menimbulkan kekhawatiran bagi warga pesisir pantai tersebut. Oleh sebab itu dalam pengembangan dan pengamanan daerah pesisir serta perlindungan kepada mansyarakat sekitar maka perlu pengetahuan mengenai karakteristik gelombang yang terjadi di pantai tersebut. Dalam penelitian ini analisa dilakukan menggunakan Teori Airy, pendekatan data analisa menggunakan data angin dari BKMG Juwata Tarakan. Hasil analisa transformasi gelombang selama 10 tahun (2010-2019) di Pantai Amal Baru diperoleh arah angin yang mendominasi dari timur menuju kearah barat, panjang fetch 224,589 m, tinggi gelombang pecah berkisar antara 0,8 m – 2,4 m dan kedalaman gelombang pecah berkisar antara 0,38 m - 2,1 m. Dari hasil analisa, pada kondisi angin maksimal, angin rata-rata, dan angin yang sering terjadi  Kecepatan Angin Darat yang bertiup antara 3,5-15 m/s, Kecepatan Angin Laut yang bertiup antara 5 - 19 m/s, Peramalan Gelombang Angin Tinggi signifikan (H) antara  0,9 - 4,8 m, Priode (T) antara 5,5 - 10,2 s, Durasi (D) antara 9 - 11 jam, sehingga hasil Analisa untuk Tinggi Gelombang (H) antara 0,8 - 2,4 m, Kedalaman Gelombang Pecah (Hb) antara 0,3 - 2,1 m, dan Sudut datang gelombang 8Ëš- 30Ëš. Sehingga dapat disimpulkan bahwa tinggi gelombang yang dihasilkan pada saat kondisi kecepatan angin maksimal dan kecepatan angin sering terjadi  merupakan gelombang destruktif (gelomban yan dapat merusak pantai).Kata kunci: Gelombang pecah, hindcasting, karakteristik gelombang, Pantai amal baru, refraksi, shoaling.
STUDI ANALISIS STRUKTUR RANGKA HANGGAR PESAWAT MAF KOTA TARAKAN BERDASARKAN PERATURAN TERBARU (SNI 1727 2020 DAN SNI 1726 2019) Apriliana, Anna Celia; Utomo, Edy
Civil Engineering Scientific Journal Vol 1, No 1 (2022): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (1167.758 KB) | DOI: 10.35334/cesj.v1i1.2889

Abstract

ABSTRACT: One of the hangers located in Tarakan is the one belonging to MAF Foundation; it was built in 1980. It is in Jalan Mulawarman, Juwata Airport, Tarakan. The hangar is used for maintenance, reparation, and protection for planes from the weather. Its construction uses a structure of roof frame made up of steel pipe of galvanize. New rule states that a construction is required to consider the seismic factor, as it says in SNI 1726 2019. Hence, an identification is needed to examine its strength and stability. This study was conducted by employing models of 2-Dimension and 3-Dimension, considering the existing condition of the hangar. Based on the analysis, it shows that the hangar has a structure instability due to one the rods (B130), which does not qualify the slender requirement as pull rod or pushrod. With a further analysis, the rod B130 does not affect significantly to the hangar structure, meaning it can be removed from the construction.Keywords: hangar, rigid frame of roof, galvanize steel pipe, tension chord, compression chordABSTRAK: Salah satu Hanggar Pesawat yang ada di Kota Tarakan adalah milik Yayasan MAF, yang dibangun sejak tahun 1980. Hanggar ini terletak di Jalan Mulawarman, Bandar Udara Juwata, Kota Tarakan. Infrastruktur hanggar digunakan sebagai tempat perawatan, tempat perbaikan, dan perlindungan pesawat dari cuaca luar. Konstruksi hanggar ini menggunakan struktur rangka atap dengan menerapkan material pipa baja galvanis. Saat ini telah diwajibkan perhitungan struktur menggunakan faktor gempa sesuai dengan SNI 1726 2019. Sehingga perlu untuk dilakukan identifikasi dari kekuatan struktur Hanggar Pesawat milik Yayasan MAF, dengan tujuan menilai kekuatan atau kestabilan struktur Hanggar Pesawat tersebut. Penelitian dilakukan dengan menggunakan model 2-Dimensi dan 3-Dimensi sesuai dengan kondisi eksisting Hanggar Pesawat tersebut. Berdasarkan analisis yang telah dilakukan baik pada pemodelan 2-Dimensi dan 3-Dimensi menunjukkan konstruksi Hanggar Pesawat mengalami ketidakstabilan struktur. Hal ini disebabkan oleh salah satu batang yaitu batang B130 tidak memenuhi syarat kelangsingan sebagai batang tekan atau batang tarik. Telah dilakukan analisis lebih jauh batang B130 tersebut ternyata tidak memberikan pengaruh signifikan terhadap Hanggar Pesawat, sehingga dapat dihilangkan sebagai salah satu elemen penyusun konstruksi Hanggar Pesawat tersebut.Kata Kunci: Hanggar Pesawat, Struktur Rangka Atap, Pipa Baja Galvanis, Batang Tarik, Batang Tekan 
STUDI BANGUNAN PELINDUNG PANTAI TIPE REVETMENT SEBAGAI ALTERNATIF PENANGANAN ABRASI DI PANTAI AMAL BARU KOTA TARAKAN Maharani, Arin Isyamelya; Utomo, Edy
Civil Engineering Scientific Journal Vol 3, No 3 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i3.5900

Abstract

ABSTRACT: It is known that Amal Baru beach, Tarakan City has experienced 72% abrasion phenomenon and 28% accretion phenomenon with the condition of shoreline change due to abrasion reaching 2.59 meters per year, which causes heavy damage to the coastal area. One of the triggers that causes this abrasion phenomenon is changes in wave characteristics. One solution to protect the coast from abrasion and accretion is to build a revetment type of coastal protection building. This study aims to determine the value of the generated wave height and the value of the thickness of the protection layer as a reference in designing revetment type of coastal protection buildings utilizing several methods, namely, the Wilson Method used to analyze wave generation, the Admiralty Method used in tidal analysis, the Weibull Method used to analyze long-term wave predictions. The results of calculations of wave height and tides that have been carried out at Amal Baru Beach, Tarakan City for revetment type of coastal buildings, namely, for the main protection layer showed the peak width of the building reaching 1.76 meters and the thickness of the protection layer was 1.17 meters. The second protection layer used quarrystone with a grain weight of 2.435 meters and has a protection layer thickness of 0.21 meters. The core protection layer used quarrystone with a grain weight of 0.12 kg and had a protection layer thickness of 0.08 meters. Toe protection used quarrystone with a grain weight of 48.7 kg and has a toe protection width of 0.85 meters and a protection layer thickness of 0.57 meters.Keywords: Abrasion, Accretion, Coastal Building, Protection Layer, Beach, Revetment ABSTRAK: Diketahui bahwa di pantai Amal Baru, Kota Tarakan telah mengalami 72% fenomena abrasi dan 28% fenomena akresi dengan kondisi perubahan garis pantai akibat abrasi adalah 2,59 meter per tahun, yang menyebabkan kerusakan berat pada daerah pantai. Salah satu pemicu yang menyebabkan adanya fenomena abrasi ini adalah perubahan pada karakterisitik gelombang. Salah satu solusi untuk melindungi pantai dari abrasi dan akresi adalah dengan membuat bangunan pelindung pantai tipe Revetment. Penelitian ini bertujuan untuk mengetahui nilai tinggi gelombang yang dibangkitkan dan nilai ketebalan lapis lindung sebagai acuan dalam mendesain bangunan pelindung pantai tipe Revetment dengan menggunakan beberapa  metode yaitu, Metode Wilson digunakan untuk menganalisis pembangkitan gelombang, Metode Admiralty digunakan dalam analisis pasang surut, Metode Weibull digunakan untuk menganalisis prediksi gelombang jangka panjang. Hasil perhitungan dari tinggi gelombang dan pasang surut air laut yang telah dilakukan di Pantai Amal Baru Kota Tarakan untuk bangunan pantai tipe Revetment yaitu, untuk lapis lindung utama diketahui lebar puncak bangunan 1,76 meter dan tebal lapis lindung 1,17 meter. Lapis lindung kedua digunakan quarrystone dengan berat butir 2,435 meter dan memiliki tebal lapis lindung 0,21 meter. Lapis lindung inti digunakan quarrystone dengan berat butir 0,12 kg dan memiliki tebal lapis lindung 0,08 meter. Toe protection (pelindung kaki) digunakan quarrystone dengan berat butir 48,7 kg dan memiliki lebar pelindung kaki 0,85 meter serta tebal lapis lindung 0,57 meter.Kata kunci: Abrasi, Akresi, Bangunan Pantai, Lapis Lindung, Pantai, Revetment
PENANGANAN ABRASI PANTAI AMAL BARU KOTA TARAKAN DENGAN BANGUNAN PELINDUNG PANTAI TIPE DETACHED BREAKWATER Haryanti, Giar Tri; Utomo, Edy
Civil Engineering Scientific Journal Vol 3, No 2 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i2.5897

Abstract

ABSTRACT: Amal Baru Beach has experienced damage in the form of abrasion and accretion which occurs due to the characteristics of waves that are destructive. One solution to protect Amal Baru Beach from the damage that occurs is a Detached Breakwater which is planned for the next 25 years. The result of this study indicate that the dominant wind direction comes from the East of Tarakan Island with a wave height at a 25-years return period of 2,85 meters with a period of 9,40 seconds. The planned Detached Breakwater structure is a sloping side building with a main protective layer using two recommended tetrapods, namely W = 0,5 tons and W = 0,084 tons, with a building peak width (B) of 1,76 meters, a main protective layer thickness (t) of 1,17 meters, a second protective layer thickness (t) of 0,21 meters, and a toe protection height of a 0,58 meters. The length of the building (Ls) is 250 meters, the width of the building gap (Lg) is 100 meters and the distance of the breakwater from the coastline (Y) is 100 meters. Keywords: Abrasion, Accretion, Coastal Building, Protective Layer, Beach ABSTRAK: Pantai Amal Baru telah mengalami kerusakan berupa abrasi dan akresi yang terjadi akibat dari karakteristik gelombang yang bersifat merusak atau destruktif. Salah satu solusi untuk melindungi Pantai Amal Baru dari kerusakan yang terjadi adalah bangunan pelindung pantai tipe Detached Breakwater. Data yang digunakan dalam penelitian ini merupakan data primer dan data sekunder yang akan digunakan dalam perencanaan Detached Breakwater yang direncanakan pada 25 tahun kedepan. Hasil dari penelitian ini menunjukkan bahwa dominasi arah angin bersumber dari arah Timur Pulau Tarakan dengan tinggi gelombang pada kala ulang 25 tahun sebesar 2,85 meter dengan periode 9,40 detik. Struktur Detached Breakwater yang direncanakan adalah bangunan sisi miring dengan lapis lindung utama menggunakan tetrapod yang direkomendasikan ada dua, yaitu W = 0,5 ton dan W = 0,084 ton, dengan lebar puncak bangunan (B) sebesar 1,76 meter, tebal lapis lindung utama (t) sebesar 1,17 meter, tebal lapis lindung kedua (t) sebesar 0,21 meter, dan tinggi pelindung kaki (toe protection) sebesar 0,58 meter. Panjang bangunan (Ls) sebesar 250 meter, lebar celah bangunan (Lg) sebesar 100 meter dan jarak pemecah gelombang dari garis pantai (Y) sebesar 100 meter.Kata kunci: Abrasi, Akresi, Bangunan Pantai, Lapis Lindung, Pantai
REVIEW DESAIN STRUKTUR PORTAL BAJA KONSTRUKSI PASAR KOTA TARAKAN Pongsinoran, Regina; Utomo, Edy
Civil Engineering Scientific Journal Vol 3, No 3 (2024): Civil Engineering Scientific Journal
Publisher : Jurusan Teknik Sipil, Fakultas Teknik, Universitas Borneo Tarakan

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35334/cesj.v3i3.5755

Abstract

ABSTRACT: The construction of a steel portal structure (gable frame) is one of the market buildings in Tarakan City that uses steel structure construction. Naturally, components that support the strenght of the structure include rafters, columns, beams, curtains, base plates, and welded bolt connections. Since the strength factor is the primary consideration when planning a building structure, its is necessary to review the strength of capacity of the steel portal structure in accordance with SNI 1729:2020, SNI 1727:2020, and SNI 1726:2019. The three-dimensionally modelled SAP2000 version 23 program helped with the steel portal structure study. One of the structural components, the curtains, provides dangerous recommendations for bending forces and deflections, according to the findings of the structural capacity loading design analysis. But because the real operating load is lower than the SNI 1727:2020 design load, the curtains are still safe under actual circumstances. Thus, a proposal for the same curtain profile shape with a different geometry is provided based the loading design requirements.Keywords: Construction, Market, Steel Portal Structure ABSTRAK: Salah satu bangunan pasar di Kota Tarakan yang menggunakan konstruksi struktur baja adalah Pasar Kota Tarakan. Konstruksi tersebut adalah konstruksi struktur portal baja (gable frame), yang tentunya memiliki komponen-komponen yang berperan dalam menunjang kekuatan strukturnya, seperti rafter, kolom, balok, gording, base plate dan sambungan baut las. Faktor kekuatan merupakan hal yang utama dalam perencanaan suatu struktur gedung, sehingga perlu dilakukan suatu review terhadap kekuatan atau kapasitas dari struktur portal baja tersebut sesuai SNI 1729:2020, SNI 1727:2020, SNI 1726:2019. Dalam analisis struktur portal baja ini dibantu dengan aplikasi SAP2000 versi 23, yang dimodelkan dengan 3-dimensi. Berdasarkan hasil analisis kapasitas struktur yang telah dilakukan yang mengacu pada ketentuan analisis desain pembebanan SNI 1727:2020, menunjukkan bahwa salah satu komponen struktur yaitu gording memberikan rekomendasi yang tidak aman terhadap gaya lentur dan juga lendutan. Akan tetapi, pada kondisi aktualnya, gording masih dalam kondisi yang aman dikarenakan beban aktual yang bekerja lebih kecil dibandingkan dengan beban desain SNI 1727:2020. Sehingga, berdasarkan ketentuan desain pembebanan diberikan rekomendasi bentuk profil gording yang sama dengan geometri yang berbeda.Kata kunci: Baja, Konstruksi, Pasar, Struktur Portal Baja