Claim Missing Document
Check
Articles

Found 25 Documents
Search

Efektivitas Penambahan Pin Terhadap Kuat Cabut Tulangan Bambu Apus pada Beton Normal Struktural Yanuar Haryanto; Nanang Gunawan Wariyatno; Buntara Sthenly Gan
Jurnal Teknik Sipil Vol 23 No 3 (2016)
Publisher : Institut Teknologi Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.5614/jts.2016.23.3.3

Abstract

Abstrak. Bambu merupakan material alternatif yang memiliki potensi untuk dikembangkan sebagai pengganti baja tulangan dikarenakan bambu memiliki kekuatan tarik yang dapat disejajarkan dengan baja. Namun demikian terdapat kendala dari sifat kembang susut bambu, dimana pada pemakaiannya sebagai tulangan, bambu akan mengembang akibat penyerapan air pada beton segar dan kemudian akan menyusut bersamaan dengan penguapan air pada proses pengeringan beton. Penyusutan bambu berakibat pada hilangnya lekatan bambu dan beton yang dapat menyebabkan terjadinya keruntuhan. Makalah ini membahas efektivitas penambahan pin terhadap kuat cabut tulangan bambu apus pada beton normal struktural. Pin yang ditambahkan terbuat dari kawat baja yang ditanamkan sebagai penahan saat terjadinya penyusutan tulangan bambu. Benda uji berbentuk silinder dengan ukuran tinggi 20 cm dan diameter 12 cm, pendekatan analisis dilakukan untuk penyetaraan dimensi bambu dengan diameter tulangan baja 6 mm. Variasi jumlah pin yang digunakan adalah 0, 2, 3 dan 4. Hasil kajian menunjukkan bahwa rasio kuat cabut tulangan bambu apus dengan penambahan 3 pin terhadap kuat cabut tulangan baja adalah1,01. Penambahan pin menunjukkan efektivitas yang tinggi terhadap kuat cabut bambu apus dengan pengaruh sebesar 92,22%.Abstract. Bamboo is an alternative material that has the potential to be developed as a replacement for steel bars because bamboo has a tensile strength comparable to steel. However, there are constraints on the properties of the expansion and shrinkage of bamboo, which in its use as reinforcement, bamboo will expand due to the absorption of water in fresh concrete and then will shrink along with the evaporation of water in the process of drying concrete. Shrinkage in a bamboo cause a loss of bonding in bamboo and concrete that may cause a collapse. This paper discusses the effectiveness of the addition of a pin to the pullout strength of apus bamboo reinforcement on the structural normal concrte. The pin that was added is a steel wire that is implanted as a retaining when the shrinkage of bamboo reinforcement occur. The specimen was a concrete cylinder with a height of 20 cm and a diameter of 12 cm, analytical approach taken to equalize the dimensions of the bamboo with a diameter of 6 mm steel reinforcement. Variation of the number of pins used were 0, 2, 3 and 4. The results show that the ratio of the pullout strength of bamboo reinforcement with the addition of 3 pins, to the pullout strength of steel reinforcement is 1.01. The Addition of pin showed a high effectiveness to the pullout strength of apus bamboo reinforcement with a 92.22% infulence.
Abu Terbang (Fly Ash) Sebagai Bahan Tambah Untuk Meningkatkan Kuat Tekan Bata Beton (Paving Block) Gathot Heri Sudibyo; Yanuar Haryanto; Fatkhurrozak Fatkhurrozak
Dinamika Rekayasa Vol 4, No 2 (2008): Dinamika Rekayasa - Agustus 2008
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2008.4.2.115

Abstract

This research was aimed to know the influence of fly ash addition at paving block stress strength. Variation of fly ash was 0%, 20%, 40%, 60%, and 80% from weight of cement with water cement ratio 0,25. The speciment was hexagonal and cube with the comparison 1 cement : 6 sand. The result showed that the stress strength of hexagonal paving block at 56 days with fly ash 20%, 40%, 60% and 80% was increase to 37,166% (7,057 MPa), 18,248% (3,465 MPa), 8.110% (1,54 MPa), and 14,193% (2,695 MPa). The cubic paving block at 56 days with fly ash 20%, 40%, 60% and 80% was increase to 35,932% (5,969 MPa),15,135% (2,514 MPa), 9,534% (1,584 MPa), and 8,318% (1,382 MPa).
Kajian Ketahanan Kejut Beton Ringan Serat Alumunium Dengan Agregat Alwa Yanuar Haryanto
Dinamika Rekayasa Vol 2, No 1 (2006): Dinamika Rekayasa - Februari 2006
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2006.2.1.14

Abstract

This research was aimed to know the addition of alumunium fiber influence to the impact resistance of lightweight concrete. In this research, lightweight concrete was made from cement, water, sand, ALWA (Artificial Lightweight Aggregate) and Superplasticizer, mix design method was Dreux-Corrise Method. The speciment was plate with 20 cm diameter and 4 cm high. Variation of alumunium fiber addition was 0%, 0,35%, 0,75% and 1% cement weight. The test was done after 28 days age of speciment. The result showed that the most significant increasing of impact resistance was obtained on 0,75% alumunium fiber addition, which was 250% for first crack and 300% for failure
Evaluasi Kinerja Gedung Dinas Kependudukan Dan Catatan Sipil Purbalingga Dengan Analisis Pushover Arnie Widyaningrum; Yanuar Haryanto
Dinamika Rekayasa Vol 15, No 2 (2019): Jurnal Ilmiah Dinamika Rekayasa - Agustus 2019
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2019.15.2.240

Abstract

Dalam rangka meningkatkan pelayanan bidang kependudukan, kabupaten Purbalingga membangun gedung baru Dinas Kependudukan dan Catatan Sipil. Dengan fungsi sebagai perkantoran, gedung dua lantai ini termasuk bangunan dengan kategori resiko II yang menurut peraturan harus memiliki level kinerja minimal LS (Life Safety) untuk kala ulang gempa 500 tahun. Kajian ini bertujuan untuk menentukan kinerja gedung Dinas Kependudukan dan Catatan Sipil kabupaten Purbalingga. Kajian dilakukan menggunakan analisis pushover yang merupakan teknik yang populer oleh karena kemudahaanya, yang banyak digunakan untuk mengevaluasi baik bangunan baru maupun lama. Hasil kajian menunjukkan pada saat tercapai titik kinerja, diperoleh gaya geser dasar sebesar 609510,9 kg dan 687598,1 kg masing-masing pada sumbu X dan sumbu Y. Rasio simpangan yang terjadi masing-masing adalah 0,71% pada sumbu X dan 0,85% pada sumbu Y. Nilai keduanya kurang dari 1% yang menandakan bahwa kinerja struktur gedung Dinas Kependudukan dan Catatan Sipil kabupaten Purbalingga ini berada pada level IO (Immediate Occupancy) dimana tidak terdapat kerusakan yang berarti pada struktur, kekuatan dan kekakuannya kira-kira hampir sama dengan kondisi sebelum gempa. Komponen nonstruktur masih berada ditempatnya dan sebagian besar masih berfungsi jika utilitasnya tersedia. Gedung dapat tetap berfungsi dan tidak terganggu dengan masalah perbaikan. Dapat disimpulkan bahwa perancangan gedung Dinas Kependudukan dan Catatan Sipil kabupaten Purbalingga telah memenuhi kaidah kegempaan
Pengaruh Panjang Penyaluran Sambungan Terhadap Kekuatan Balok Beton Pracetak Tulangan Bambu Nanang Gunawan Wariyatno; Yanuar Haryanto; Gathot Heri Sudibyo
Dinamika Rekayasa Vol 11, No 1 (2015): Jurnal Ilmiah Dinamika Rekayasa - Februari 2015
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2015.11.1.94

Abstract

Kajian ini bertujuan untuk mengetahui pengaruh panjang penyaluran sambungan terhadap kekuatan balok beton pracetak tulangan bambu. Kajian dilakukan terhadap 6 tipe benda uji, masing-masing balok tulangan baja, balok tulangan bambu, balok pracetak penyaluran 5 cm, balok pracetak penyaluran 7 cm, balok pracetak penyaluran 9 cm, dan balok pracetak penyaluran 9 cm tanpa diangkur. Benda uji memiliki dimensi 120 mm x 150 mm x 600 mm dengan masing-masing tipe dibuat sejumlah 3 buah, dan pengujian dilakukan dengan pembebanan dua titik. Hasil kajian memperlihatkan bahwa kekuatan balok tulangan bambu memiliki rasio 0,53 terhadap kekuatan balok tulangan baja. Panjang penyaluran sambungan yang menghasilkan kekuatan tertinggi pada balok pracetak adalah 7 cm dengan rasio 0,21. Pengangkuran menghasilkan peningkatan kekuatan sebesar 47,20% pada balok pracetak dengan panjang penyaluran sambungan 9 cm. Keruntuhan balok pracetak terjadi pada sambungan.
Efektifitas Wire Rope Sebagai Perkuatan padaDaerah Momen Negatif Balok Beton Bertulang Tampang T Yanuar Haryanto
Dinamika Rekayasa Vol 7, No 2 (2011): Dinamika Rekayasa - Agustus 2011
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2011.7.2.47

Abstract

The loss due to collapsing structure includes not only materialsbutalso take lives. In thecase of structure function changing that may cause increasing loads, it is required to put efforts instrengtheningthe structure elements in order to increase the capacity and hence to avoid the possibility of collapsing. The objective of this research was to study thebehavior of T-sectional reinforced concrete beamstrengthenedin the negative momentregionwithwire rope and mortar composite. The test was carried out to three T-sectional beams: without wire rope reinforcement (BK), with 2 wire rope reinforcements (BP1), and with 4 wirerope (BP2) reinforcements. The type of wire rope was Independent Wire Rope Core (IWRC) with10 mm diameter. The testing method used was two points static loading with flens positions below (the flens part experienced tensile stress). Results showed that the maximum load carryingcapacity of BP1 and BP2 specimens increased by ratios of 1.59 and 2.03 to the BK specimen respectively. However, the increase was achievedafter the development and propagation of highcracking. Ductility of BP1 and BP2 specimens decreased by ratios of 0.62 and 0.36 to the BK specimen respectively. The initial stiffness of BP1 and BP2 increased byratios of 1.09 and 1.08 to the BK specimen respectively.The effective stiffness ofBP1 and BP2 specimensdecreased by ratios of 0.88 and 0.92 to the BK specimenrespectively. Stress occurred in the wire rope based on the analysis results of Response-2000 and the layer method have not reached 50% ofthe ultimate stress resulted from the preliminary test. In general, unless improvement was given to the stiffness characteristics of thewire rope, its contribution would not become optimum.
Kinerja Model Struktur Gedung Lima Lantai Pada Kondisi Tanah Keras Di Wilayah Banyumas Akibat Beban Gempa SNI 03-1726-2002 Dan SNI 03-1726-2012 Yanuar Haryanto; Gathot Heri Sudibyo; Nanang Gunawan Mariyatno
Dinamika Rekayasa Vol 11, No 2 (2015): Jurnal Ilmiah Dinamika Rekayasa - Agustus 2015
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2015.11.2.77

Abstract

Indonesia menempati posisi ketiga dunia dari 153 negara yang memiliki potensi bahaya gempa. Hal ini disebabkan Indonesia merupakan tempat bertemunya tiga lempeng besar dunia yaitu Lempeng Indo-Australia, Lempeng Eurasia, dan Lempeng Pasifik. Interaksi antara ketiga lempeng inilah yang menyebabkan Indonesia memiliki aktivitas kegunungapian dan kegempaan yang tinggi. Perubahan peraturan gempa Indonesia berpeluang menyebabkan terjadinya perubahan kinerja struktur gedung. Makalah ini bertujuan untuk mengkaji kinerja model struktur gedung lima lantai pada kondisi tanah keras di wilayah Banyumas akibat beban gempa SNI 03-1726-2002 dan SNI 03-1726-2012, yang dilakukan dengan analisis beban dorong (pushover). Hasil kajian menunjukkan bahwa terjadi peningkatan gaya geser dasar sebesar 1,48% pada model struktur gedung saat tercapai titik kinerja (performance point). Displacement yang terjadi mengalami peningkatan sebesar 19,61% sedangkan daktilitas mengalami penurunan sebesar 43,14%. Kinerja model struktur gedung tidak mengalami perubahan yaitu tetap pada level Immediate Occupancy dimana tidak terdapat kerusakan yang berarti pada struktur, kekuatan dan kekakuannya kira-kira hampir sama dengan kondisi sebelum gempa. Komponen nonstruktur masih berada ditempatnya dan sebagian besar masih berfungsi jika utilitasnya tersedia. Gedung dapat tetap berfungsi dan tidak terganggu dengan masalah perbaikan.
IDENTIFIKASI LOKASI STRATEGIS UNTUK KAWASAN INDUSTRI DI KABUPATEN PURBALINGGA Probo Hardini; Yanto Yanto; Yanuar Haryanto
Dinamika Rekayasa Vol 3, No 2 (2007): Dinamika Rekayasa - Agustus 2007
Publisher : Jenderal Soedirman University

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.20884/1.dr.2007.3.2.112

Abstract

To reach the regional development equity, it is necessary to spread central activities in sub-region. This is a land use planning need to gain. According to development paradigms, industry is a leading sector that will influence its hinterland. This research was aims to know the strategic location for industrial area in Purbalingga, that have consideration in phisichal, economic, social, and stakeholders’ interest. The result indicate that industry should not located in central region as we saw in existing. The best alternative location for industrial area are Bukateja, Kutasari, Rembang, Mrebet, Karangreja , and Karangmoncol.
PENGARUH SERAT LIMBAH KARPET TERHADAP KUAT LENTUR BALOK BETON RINGAN DARI ALWA Yanuar Haryanto
Techno (Jurnal Fakultas Teknik, Universitas Muhammadiyah Purwokerto) Vol 17, No 2 (2016): Techno Volume 17 No 2, Oktober 2016
Publisher : Universitas Muhammadiyah Purwokerto

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.30595/techno.v17i2.1170

Abstract

ABSTRAK Artificial Lightweight Aggregate atau biasa disebut ALWA dapat digunakan sebagai agregat kasar untuk mendapatkan beton ringan. Di sisi lain, salah satu cara mengingkatkan kinerja beton adalah dengan menambahkan serat pada campuran adukan beton. Makalah ini membahas pengaruh serat limbah karpet terhadap kuat lentur balok beton ringan dari ALWA. Pengujian dilakukan terhadap balok beton berukuran 15 cm x 15 cm x 60 cm dengan variasi volume fraksi serat limbah karpet 0%, 0,25%, 0,50%, 0,75%, dan 1,00%. Hasil pengujian menunjukkan bahwa serat limbah karpet mampu meningkatkan kuat lentur balok beton ringan dari ALWA sampai dengan 1,09 MPa atau meningkat sebesar 7,15%. Kadar serat limbah karpet yang optimum untuk mencapai kuat lentur yang maksimum adalah 0,47%. Dengan adanya serat limbah karpet, keruntuhan tidak terjadi secara tiba-tiba dengan nilai defleksi mengalami pengurangan sampai dengan 24,32%. Kata kunci : ALWA, Beton ringan, Defleksi, Keruntuhan, Kuat lentur ABSTRACT Artificial Lightweight Aggregate or so-called ALWA can be used as coarse aggregate to obtain lightweight concrete. On the other hand, one way to improve the performance of concrete is by adding fiber to the concrete mix. This paper discusses the effect of waste carpet fiber to the flexural strength of ALWA lightweight concrete beams. Tests carried out on concrete beams measuring 15 cm x 15 cm x 60 cm with a variety of volume fraction of waste carpet fiber 0%, 0.25%, 0.50%, 0.75% and 1.00%. The test results showed that the waste carpet fiber can improve the flexural strength of ALWA lightweight concrete up to 1.09 MPa, an increase of 7.15%. Optimum volume fraction of carpet wate fiber to achieve the maximum flexural strength is 0.47%. With the carpet waste fiber, the failure does not occur suddenly with a value of deflection experienced a reduction of up to 24.32%. Key word: ALWA, Lightweight concrete, Deflection, Failure, Flexural strength
On the Performance of a Multi Story Irregular Apartment Building Model Under Seismic Load in Indonesian Moderately High Seismicity Region Yanuar Haryanto; Hsuan-Teh Hu; Han Ay Lie; Banu Ardi Hidayat; Eva Wahyu Indriyati
Aceh International Journal of Science and Technology Vol 8, No 1 (2019): April 2019
Publisher : Graduate Program of Syiah Kuala University

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (448.984 KB) | DOI: 10.13170/aijst.8.1.5636

Abstract

Purbalingga is regency with a potential moderately high seismicity requiring compliance of planning and implementation rules of the earthquake-resistant structural system. The purpose of this research is to evaluate the performance of a ten-story irregular apartment building model in Purbalingga due to the seismic load. The study is necessarily conducted to provide information on impacts and mitigation strategies that should be implemented. This research was conducted based on the seismic capacity of 2002 and 2012 Indonesian National Standard (SNI) including linear static analysis, dynamic response analysis, and pushover analysis. Based on the direct static review, it shows that the base shear is reduced and the drift ratio level decreases respectively for X and Y direction.Meanwhile, based on the dynamic response analysis, the drift ratio level also decreases respectively for X and Y direction. Also, the pushover analysis indicates that the performance of this apartment building model is still at Immediate Occupancy (IO) level as the post-earthquake damage state that remains safe to occupy, essentially retains the pre-earthquake design strength and stiffness of the structure. The risk of life-threatening injury as a result of structural damage is very low, and although some minor structural repairs may be appropriate, these would generally not be required before occupancy