Claim Missing Document
Check
Articles

Found 3 Documents
Search
Journal : Jurnal Teknik Mekanikal Bandar Udara

Identifikasi Disfungsi Foot Step dan Comb pada Eskalator Shelter Skytrain di Stasiun Kereta Bandar Udara Internasional Soekarno-Hatta, Cengkareng Kurniawati, Zulina; Astuti, Annisa Puji; Septiawan, Dwi Cahya; Yosafat, Yosafat; Clarissa, Gita; Bakhtiar, Ramadhani indika
Jurnal Teknik Mekanikal Bandar Udara Vol 1 No 01 (2023): Jurnal Teknik Mekanikal Bandar Udara
Publisher : Program Studi Teknik Mekanikal Bandar Udara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54147/jtmb.v1i01.878

Abstract

An escalator is one of the upward and downward lifting devices consisting of separate steps that can run a long path like a rail or chain driven by a machine. The benefits of escalators are considerable, for example, it can move a lot of people and do not hold a time span, especially during congested hours. Therefore,damage to the escalator is quite disruptive to the comfort of passengers. One important part of the escalator that is quite vulnerable to damage is the footstep. Footstep that serves as a place for passengers to stand and step on. When the author made direct observations, several problems were found in the Soekarno-Hatta International Airport Train Station escalator unit. The problem is that the step runs unbalanced, the comb is broken and there is a sound of collision between steps. Based on research to determine the cause of damage to the escalator step and comb unit, it was concluded that there was a collision between the step and the comb on the escalator at the Soekarno-Hatta International Airport Train Station, which reduced the performance of the escalator because there were indications in the form of broken roller chain, broken rail/track where the roller chain runs, not straight roller connecting plate on the roller chain, then there are different settings between the left and right roller chains, finally the lack of the connecting chain between the gearbox and the drive wheel.
EFEKTIFITAS PERAWATAN TERJADWAL PADA AIR CONDITIONING JENIS STANDING FLOOR DI BANDAR UDARA SULTAN HASSANUDIN - MAKASSAR Kurniawati, Zulina; Astuti, Annisa Puji; Yuspin, Yosia; Azizi, Dimas Setia; Pradani Putri, Aulia Bilqis; Lestari, Endah Dwi
Jurnal Teknik Mekanikal Bandar Udara Vol 1 No 02 (2023): Jurnal Teknik Mekanikal Bandar Udara
Publisher : Program Studi Teknik Mekanikal Bandar Udara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54147/jtmb.v1i02.1040

Abstract

Air Conditioning (AC) Standing Floor is a type of cooler whose use is notaffixed to residential walls but placed on the floor. Air Conditioner (AC)is one type of electronic device that consumes quite a lot of time for therepair and maintenance process. Air Conditioning (AC) Standing Floorneeds to be maintained at a comfort level as a necessity for the comfort ofa room. AC component maintenance can make it last longer and the coldit produces is as needed. In order to have a long lifetime and reduce thecost of damage that occurs if there is no consistency in maintenance.Examination is carried out using an anemometer and stroboscope. Thepurpose of maintenance on the air conditioner is to smooth so that thereare no obstructions between the evaporator fins.
Identifikasi Penyebab Abnormality Jarak Antar Step pada Eskalator Boarding Lounge Gate E3 Terminal 2 di Bandar Udara Internasional Soekarno-Hatta Kurniawati, Zulina; Astuti, Annisa Puji; Nugroho, Rafid Rizky; Apriliansa, Muhamad Rafi; Andriansyah, Ricky; Putra Alief, Muhammad Tezza
Jurnal Teknik Mekanikal Bandar Udara Vol 1 No 3 (2023): JURNAL TEKNIK MEKANIKAL BANDAR UDARA
Publisher : Program Studi Teknik Mekanikal Bandar Udara

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.54147/jtmb.v1i3.1083

Abstract

This study aims to analyze the causes of the distance between steps abnormality on the Boarding Lounge Gate E3 Terminal 2 escalator at Soekarno-Hatta International Airport and to find out the steps that must be implemented in overcoming this problem. The research methodology used is a qualitative method in which the author collects data through field research (field research) of the object under study to obtain the required data. Data collection techniques using 3 methods, namely: observation method, interview method, and documentation method. The results of this study were found to be abnormal conditions in the step distance on the escalator Boarding Lounge Gate E3 Terminal 2. Based on the Elevator and Escalator Test Module of The Public Works Department the normal step distance is 4-5 mm. Meanwhile, based on case studies in the field, the results were 7.93 and 13.79 mm.