Claim Missing Document
Check
Articles

Found 8 Documents
Search

Harmonic Mitigation with Active Filter in Coal Boiler Plant PT. Salim Ivomas Pratama Widagdo, Reza Sarwo; Andriawan, Aris Heri; Tauladan, Imam Suri
Jurnal ELEMENTER (Elektro dan Mesin Terapan) Vol 9 No 2 (2023): Jurnal Elektro dan Mesin Terapan (ELEMENTER)
Publisher : Politeknik Caltex Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35143/elementer.v9i2.6047

Abstract

Coal Boiler Plant at PT. Salim Ivomas Pratama is a plant for making steam, almost all activities in the cooking oil and margarine production process utilize electrical energy, such as submersible and centrifugal electric motors with controllers, computers, AC inverters, and many others which include non-linear loads. Electrical load whose correlation between voltage and current is unbalanced, this non-linear load will result in harmonic disturbances in the electric power system which causes a reduction in the service life of electrical equipment. Harmonics are defined as voltage and current frequency distortions that are not sinusoidal from pure frequencies. This study aims to determine how effective the active filter design simulated with the PSIM Software is in reducing harmonics with a non-linear load of 3 VSD connected to a 55 kW, 0.37 kW, and 7.5 kW induction motor. The results of measurements and analysis show that there are harmonics on the panel. SDP with a current harmonic value for phase R of 26.6%, phase S of 27.5%, and phase T of 25.5%, when compared with standard harmonics, all phases exceed the standard SPLN with a standard value of 20%. Then it is necessary to reduce harmonics with an active filter, after designing andsimulating it in the PSIM software the simulation results show that the current harmonics have changed for phase R by 3.3%, phase S by 4.0%, and phase T by 3,4 %. This shows that the design of the active filter is quite effective in mitigation a harmonic, to then be applied in practice at PT. Salim Ivomas Pratama in reduction the harmonics in a coal boiler plant.
Pelatihan Electrical Transient Analysis Program Software (ETAP) Mendukung Program Teaching Factory (TEFA) pada Tingkat Sekolah Menengah Kejuruan (SMK) Tauladan, Imam Suri; Syamsir, Hendri Novia; Sahar, Muzni; Ihsan, Boy
BATOBO: Jurnal Pengabdian Kepada Masyarakat Vol 2 No 2: BATOBO: Desember 2024
Publisher : Jurusan Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/batobo.2.2.111-118

Abstract

Menghadapi permasalahan tuntutan industri yang semakin tinggi terhadap lulusan vokasi serta sulitnya mengimplementasikan metode pembelajaran teaching factory pada tingkat pendidikan kejuruan, diperlukan transfer pengetahuan dari perguruan tinggi untuk masyarakat khususnya Guru dan Siswa/i Sekolah Menengah Kejuruan Negeri (SMKN) 2 Pekanbaru. Saat ini tuntutan industri mengisyaratkan bahwa lulusan vokasi terampil dalam penggunaan software yang berhubungan dengan elektro arus kuat salah satunya software ETAP. Selain itu Guru Jurusan Teknik Tenaga Listrik dan Teknik Instalasi Listrik SMKN 2 Pekanbaru, belum mendapatkan pendampingan penerapan teknologi dalam pelatihan ETAP software. Sehingga perlunya kegiatan transfer ilmu teknologi pelatihan ETAP untuk mendukung program teaching factory (TEFA). Metode pelaksanaan pelatihan yang digunakan berbasis metode workshop. Penggunaan metode workshop bertujuan untuk kegiatan yang interaktif untuk meningkatkan pemahaman dan mengembangkan keterampilan dalam materi yang disajikan. Adapun materi yang dibahas pada pelatihan ini adalah analisa aliran daya pada sistem kelistrikan radial yang bertujuan untuk memperbaiki level tegangan pada bus dan menganalisis aliran daya pada setiap bus. Dari hasil kegiatan workshop menunjukkan Guru dan Siswa/i dapat melakukan simulasi analisa aliran daya dengan menggunakan software ETAP. Selain itu, peserta mampu melakukan mitigasi terhadap permasalahan penurunan profil level tegangan pada bus sistem kelistrikan.
Penerapan Fast Fourier Transform Method Untuk Monitoring Tegangan Fluktuasi Tauladan, Imam Suri; Hendri Novia Syamsir; Arif Gunawan
Jurnal ELEMENTER (Elektro dan Mesin Terapan) Vol 10 No 2 (2024): Jurnal Elektro dan Mesin Terapan (ELEMENTER)
Publisher : Politeknik Caltex Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35143/elementer.v10i2.6215

Abstract

Based on PLN standards regulated in Minister of Energy and Mineral Resources Regulation No. 20 of 2020, changes in voltage on the network must be maintained within the voltage variation range of ±5% (Normal Voltage). Voltage is the change in voltage variations in a short time. Where the voltage change exceeds or below the standard voltage variation range, namely ±5% of the normal voltage. Based on IEEE Standard 1159-1995, the sag voltage is in the range of 10% -90% of the nominal voltage which lasts for 0.5 cycles. The voltage wave is in the range of 120% of the nominal voltage. Changes in voltage variations are caused by many factors such as large motor starting currents, uncontrolled load changes and short circuit current disturbances in the electric power system. The importance of maintaining voltage is a necessity because it is related to the reliability of an electric power system. For this reason, this research proposes "Application of the Fast Fourier Transform Method to Monitor Voltage Fluctuations" as a solution to power quality problems. To make it easier to process voltage (sinusoidal), the Fast Fourier Transform (FFT) method is needed. The FFT method algorithm is needed to convert the time domain into the frequency domain, so that it can simplify the monitoring system process. This research was implemented the FFT method for monitoring voltage fluctuations in no-load and load conditions. From the results, it can be concluded that inductive loads can affect voltage quality. This was proven when carrying out tests under load, from the results of the analysis there was a decrease in voltage (voltage SAG) of 10% (Vrms = 209.5 V; time duration 0.1436 s) and an increase in voltage (voltage swell) of 20.6% ( Vrms = 278.75 V; time duration 0.228 – 0.428 s).
Analysis of Leakage Current Calculation Through Thermal Failure Voltage on 150/20 kV Transformers in GIS Simpang, Surabaya Widagdo, Reza Sarwo; Andriawan, Aris Heri; Suri Tauladan, Imam; Ivan Maulana, Ade
Jurnal ELEMENTER (Elektro dan Mesin Terapan) Vol 10 No 2 (2024): Jurnal Elektro dan Mesin Terapan (ELEMENTER)
Publisher : Politeknik Caltex Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35143/elementer.v10i2.6366

Abstract

In the current test, leaks really need to be carried out at GIS Simpang. This test was carried out by strengthening the 20 kV incoming cable in the GIS Simpang 150/20 kV transformer bay. The impact of measuring this leakage current is to reduce the occurrence of leakage currents so that they are not too severe because this can determine how much the leakage current increases in the incoming cable. The trend test results were measured to determine the comparison between the leakage current in January and the leakage current measurement process at GIS Simpang. Based on the results of leakage current testing on transformer 1 and transformer 2 incoming 20 kV cables from several phases, it shows that the results of the leakage current trend in the cables have not increased significantly. However, from the calculation results listed, it can be seen from the comparison table that the results have increased during the calculation and have slight differences compared to the leakage current measurement results themselves. This is because from the calculation results, the cable temperature detection experienced a slight increase in the cable temperature as measured by thermovision to determine the thermal failure voltage. However, the cable is still suitable for operation because the temperature of the cable itself has a standard that does not exceed 150C for several measured cable phases.
Voltage Regulation and Power Loss Analysis on 500 kV EHV Transmission Line Krian-Grati Reza Sarwo Widagdo; I Made Kastiawan; Imam Suri Tauladan; Indra Budi Hermawan
International Journal of Electrical, Energy and Power System Engineering Vol. 8 No. 1 (2025): The International Journal of Electrical, Energy and Power System Engineering (I
Publisher : Electrical Engineering Department, Faculty of Engineering, Universitas Riau

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/ijeepse.8.1.40-54

Abstract

The transmission system distributes electricity from power plants to substations before reaching consumers. During this process, obstacles such as power loss and voltage regulation occur, which must meet specific standards to prevent equipment damage. Power loss can result from factors like corona effects and insulator leakage. This study aims to analyze power loss and voltage regulation based on daily peak load data at 14:00 over 15 days, recording current and voltage values on the extra-high voltage Krian-Grati transmission network. This system uses ACSR Gannet conductors with a cross-sectional area of 392.84 mm² and a length of 79.41 km, having a resistance of 0.00086 Ω/km. Manual calculations for short transmission lines show a voltage difference between sending and receiving ends, with the sending voltage being slightly higher due to reactance, preventing a drastic voltage drop. Over 15 days in December 2024, voltage regulation did not exceed the standard maximum of <10%, with the highest recorded value at 4.7%. The highest power loss occurred on day 7 at 0.089 MW, while the lowest was on day 9 at 0.023 MW. The total power loss over 15 days reached 1.024 MW, with a daily average of 0.068 MW.
Penerapan Pembelajaran Berbasis Proyek Menggunakan Internet of Things (IoT) pada Pembuatan Tong Sampah Otomatis di SMK Negeri 1 Tuah Kemuning, Indragiri Hilir Tri Saputra, Haris; Suri Tauladan, Imam; Apriwandi; Sujana, Teguh; Rifqi Harimardika, Musyaffa; Gemala Jondya, Aisha; Firdaus
BATOBO: Jurnal Pengabdian Kepada Masyarakat Vol 3 No 1: BATOBO: Juni 2025
Publisher : Jurusan Teknik Elektro

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31258/batobo.3.1.120-128

Abstract

Kesenjangan antara kurikulum pembelajaran dan kebutuhan teknologi industri semakin nyata dalam Pendidikan Tingkat Menengah Kejuruan (SMK), khususnya terkait belum diterapkannya teknologi Internet of Things (IoT) dalam proses pembelajaran. Kondisi ini mendorong perlunya penguatan keterampilan berbasis teknologi terkini bagi siswa melalui kegiatan nyata yang relevan. Kegiatan Pengabdian kepada Masyarakat (PkM) ini bertujuan untuk mengimplementasikan teknologi IoT melalui pembuatan tong sampah otomatis pada SMK Negeri 1 Tuah Kemuning Indragiri Hilir. Selain peningkatan kesadaran pengelolaan sampah, kegiatan PkM ini merupakan solusi inovatif terhadap penguatan keterampilan berbasis teknologi terkini. Kegiatan PkM ini dilaksanakan dengan menggunakan metode pembelajaran berbasis proyek yang melalui tiga tahapan utama yaitu Perencanaan Kegiatan Mitra, Pelatihan Teknis dan Perakitan, Pengujian Fungsional dan Refleksi Hasil. Dalam tahapan pelatihan dan implementasi, awal kegiatan dimulai dengan memberikan penjelasan konsep dasar IoT kepada guru dan siswa. Selanjutnya,  kegiatan desain dan pembuatan rancang bangun tong sampah otomatis yang dilengkapi dengan sensor mendeteksi volume sampah. Tong sampah otomatis juga dilengkapi dengan sistem notifikasi berbasis aplikasi mobile dengan tujuan memudahkan pengelolaan sampah secara efisien. Selain itu, implementasi IoT dalam pengelolaan sampah bertujuan untuk memperkenalkan konsep smart city yang ramah lingkungan dan mengedukasi generasi muda tentang pentingnya pengelolaan sampah berbasis teknologi. Hasil dari kegiatan PkM ini menunjukkan bahwa penerapan teknologi IoT dapat memberikan konstribusi positif terhadap peningkatan kualitas lingkungan sekolah serta meningkatkan dan keterampilan siswa dalam bidang teknologi. Dari hasil pengukuran kuantitatif dapat disimpulkan bahwa, sebesar 96,67% mahasiswa berhasil memahami penerapan konsep teknologi IoT.
Technical Support for Maintaining Solar Power Plants in Plantation Areas, Sajen Village, Mojokerto Widagdo, Reza Sarwo; Ardianik, Ardianik; Imam Suri Tauladan; Slamet, Puji; Andriawan, Aris Heri; Hariadi, Balok
BERNAS: Jurnal Pengabdian Kepada Masyarakat Vol. 6 No. 3 (2025)
Publisher : Universitas Majalengka

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31949/jb.v6i3.13233

Abstract

Sajen Village is predominantly an agricultural and livestock-based community. However, the lack of sufficient electricity poses a significant challenge to the development of these sectors. Solar Power Generation Technology offers a sustainable solution due to the village’s potential for utilizing solar energy. To ensure the successful implementation of solar power plant, it is essential to provide the local community with adequate knowledge and skills in its operation, maintenance, and care. This community service program aims to introduce solar power plant to the residents of Sajen Village while equipping them with the necessary technical expertise. The program consists of several key activities: training on solar power plant operation and maintenance, an introduction to the principles of solar power plant design and installation, and evaluation sessions to assess the community's understanding. These activities are designed to empower participants to independently operate and maintain solar power plant systems. The final stage involves evaluating the program’s effectiveness by measuring the participants’ comprehension of solar power plant concepts, operations, and maintenance techniques. This initiative is expected to enhance the sustainability of Sajen Village's agricultural and livestock sectors by addressing the electricity shortage through renewable energy solutions. It also promotes community independence in managing solar power systems for long-term benefits
Assessment of Grounding System to Reduce Potential Electrical Disturbances at Haji Regional General Hospital, East Java Province Widagdo, Reza Sarwo; Budiono, Gatut; Tauladan, Imam Suri; Tasmono, Hadi; Nababan, Wendi Antonius S
Pelita: Jurnal Pengabdian kepada Masyarakat Vol. 4 No. 3 (2024): Pelita: Jurnal Pengabdian kepada Masyarakat
Publisher : Perkumpulan Kualitama Edukatika Indonesia

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.51651/pjpm.v4i3.517

Abstract

The grounding system in the Hospital is used to overcome when there is a touch voltage and step voltage on the transformer and also other equipment installed on the transformer. The process carried out in this study was carried out by measuring the grounding and processing the data used to determine the size and smallness of the touch voltage and Step voltage. The results of the calculation of the grounding resistance in the hospital obtained a value of 5,056 ? which can cause a touch voltage with a value of 1014 V. The step voltage in humans weighing 50 Kg produces a value of 962,8 V and the step voltage for humans weighing 70 Kg produces a value of 1299 Volts. With the results of the values ??obtained, that the value has been in accordance with the standard of Step voltage based on IEEE 80-2013 with a value of 3,140 V with a duration of disturbance of 0,5 seconds.