Journal of Electronics, Electromedical Engineering, and Medical Informatics
ISSN : -     EISSN : 26568632     DOI : https://doi.org/10.35882/jeeemi
The Journal of Electronics, Electromedical Engineering, and Medical Informatics (JEEEMI) is a peer-reviewed open-access journal. The journal invites scientists and engineers throughout the world to exchange and disseminate theoretical and practice-oriented topics which covers three (3) majors areas of research that includes 1) Electronics, 2) Biomedical Engineering, and 3)Medical Informatics (emphasize on hardware and software design). Submitted papers must be written in English for an initial review stage by editors and further review process by a minimum of two reviewers.
Articles 270 Documents
Design of a Monitoring System for Hydroganics based on Arduino Uno R3 to Realize Sustainable Development Goal`s number 2 Zero Hunger Anggara Trisna Nugraha; Dadang Priyambodo
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i1.8

Abstract

In 2019 Indonesia is able to support its nation and does not need rice imports from abroad. This situation is called rice self-sufficiency. Then in order to maintain rice self-sufficiency from year to year, it is necessary to apply technology to increase the quality of rice production. Therefore, a Hydroganic Monitoring System Design was created which is used to monitor plant watering automatically using the YL-69 soil moisture sensor controlled by Arduino Uno and instructed to the LCD to display the soil moisture value according to soil pH in real time. The watering system that has been created can automatically drain water to the plants. The water that is flowed automatically by this system comes from the fish pond that is right below it, where the water from fish excrement will produce organic nutrients for rice plants. With this research, rice production will grow more effectively to improve rice quality. With this research, it is expected that Indonesian rice production will increase effectively and in line with the improvement of rice quality. From the research that has been conducted, it is found that from the experimental data above, it can be calculated that the average water discharge in one irrigation is 2.37 m/s.
Optimization of Targeting Rocket Launchers with Wheeled Robots Anggara Trisna Nugraha; Alwy Muhammad Ravi; Dadang Priyambodo
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 1 (2021): January
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i1.7

Abstract

The quick launch weapon system is unique. This rocket launcher has a high launch rate, but the rocket launched is one stage lower than the launcher normally launched by ships of this size. For example, a (medium) cruiser would use a fast light rocket launcher to launch a light (small) rocket. Currently rocket launchers are still controlled by humans, using PCs and servo motors as control tools to determine the accuracy of the shooting angle, so complete components are needed when designing the robot so that the robot can work automatically as needed. For the input given, Automatically control the rocket launcher robot and communicate via PC, then use a USB TTL cable to forward commands to the microcontroller, then send it to the Xbee-pro transmitter circuit, then send and receive by the Xbee-pro receiver, and then send the Microcontroller for transmitter control sent to servo and rocket motors in the transmitter control system in the form of a relay. Based on the test results, the robot can guide the rocket launcher at a predetermined angle, and can launch manual rockets, multiple rockets, triple rockets and all rockets, with a success rate of up to 80%.
Design of Hybrid Portable Underwater Turbine Hydro and Solar Energy Power Plants: Innovation to Use Underwater and Solar Current as Alternative Electricity in Dusun Dongol Sidoarjo Anggara Trisna Nugraha; Dadang Priyambodo
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.5

Abstract

The need for electrical energy in Indonesia continues to increase every year. In line with the increase in the electrification ratio to 100% in 2050, the demand for electrical energy is projected to reach 7 times, namely 1,611 TWh. To meet electricity needs, the government has created a 35 GW program, but one of the largest contributors to power generation fuel is coal with a share of 58% or around 50 GW which is estimated to be exhausted within the next 68 years. For this reason, innovations are needed in terms of fulfilling electrical energy by utilizing renewable energy potential, one of which is hydro energy, which is 45,379 MW from a total resource of 75,091 MW. Therefore, from this potential, innovations related to renewable energy have been created, namely the Hybrid Portable Underwater Turbine Hydro and Solar Energy hybrid power plant. This power plant uses an undersea current as a propulsion which is hybridized with solar power to increase the production of electrical energy. This power plant has the advantage that there is an Underwater turbine design that is resistant to underwater flow and a water flow direction to increase the work efficiency of the underwater turbine. From the test results, the portable Underwater turbine hydro produces 950 W in a day. Solar panels produce 65.6 Watts a day. The total hybrid that can be produced is 1.02 kW a day. In its implementation it can supply loads of up to 900 (VA) such as lamps, fans, TV, etc. This hybrid power plant can be a solution to help meet electricity needs in the area around Dusun Dongol, Sidoarjo through alternative electrical energy innovations.
Prototype Design of Carbon Monoxide Box Separator as a Form of Ar-Rum Verse 41 and To Support Sustainable Development Goal`s Number 13 (Climate Action) Anggara Trisna Nugraha; Dadang Priyambodo
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.6

Abstract

The maritime sector is one of the paths to Golden Indonesia 2045. This is because 70% of Indonesia's territory is a sea with an area of ​​3.25 million km2 and is supported by the large potential that can be utilized for the welfare of Indonesia, one of which is as a contributor to foreign exchange with foreign exchange potential from maritime sector amounting to US $28 million to US $56 million. The problem lingers on how to possible solve the problem regarding air pollution without shutting down industrial operations. Many multinational power plants have launched different campaigns in order to minimize the problem like planting trees and the like. But these small growing industries like grilling restaurants have given way to arising problem of air pollution issues On the other hand, the ocean is a contributor to half of the world's oxygen. But in a period of 50 years, areas with minimal oxygen levels in the oceans have increased. The main cause is global warming, one of which comes from increasing levels of carbon monoxide in the air. One of these gases comes from incomplete combustion in motorized vehicles. This is also exacerbated by the growth of motorized vehicles which has increased by 11.5% per year. If left like this, marine life will be destroyed and Indonesia will not reach its peak of glory in 2045. So to overcome this problem, a prototype design of Carbon Monoxide Box Separator was created. This prototype is a combination of detector sensors consisting of MQ7 to detect carbon monoxide, MQ135 to measure air quality, and DHT11 to measure humidity and air temperature, as well as a high voltage system on the L-Box (Lightning Box) which can produce O2 because of the copper plate. on the L-Box will bind the element carbon to carbon monoxide using a voltage of 400 kV. With this prototype design, it is hoped that Indonesia can achieve its glory and also as a form of QS practice. Ar-Rum verse 41 regarding Allah's command to preserve nature and the environment.
Performance Evaluation of IoT-based SpO2 Monitoring Systems for COVID-19 Patients Trie Maya Kadarina; Rinto Priambodo
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.1

Abstract

Internet of Things (IoT) applications can be used in healthcare services to monitor patients remotely. One implementation is that it is used to monitor COVID-19 patients. During the COVID-19 pandemic, people who are infected without symptoms must self-isolate so that the virus does not spread. Measurement of blood oxygen levels or SpO2 is one of the measurements that must be carried out in routine examination procedures for self-isolating patients for early detection of silent hypoxemia in COVID-19 patients. Previous research has developed an IoT-based health monitoring system with a Wireless Body Sensor Network (WBSN) and a gateway that can be used for data acquisition and transmission. The system uses a home pulse oximeter to measure SpO2 and heart rate and an Android application that functions as an IoT gateway to collect data from sensors and add location information before sending data to the server. The WBSN has been successfully integrated with two types of open source IoT platforms, namely ThingsBoard and Elasticsearch Logstash Kibana (ELK). However, it is necessary to carry out further studies on analytical and experimental performance tests of the two systems. Therefore, the purpose of this study is to develop a performance evaluation of the IoT-based SpO2 monitoring systems using the Thingsboard and ELK as IoT platforms. To evaluate the performace we ran the monitoring system on both platforms using pulse oximeter and Android device as IoT gateway with HTTP and MQTT as transport protocol for sending the data to the server. From this study we found that average time of message delivery in ELK compared to ThingsBoard using the same protocols was higher but stable.
Oximeter and BPM on Smartwatch Device Using Mit-App Android with Abnormality Alarm Bedjo Utomo; Syaifudin Syaifudin; Endang Dian Setioningsih; Torib Hamzah; Parameswaran Parameswaran
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.4

Abstract

Monitoring is an activity that is carried out continuously. Healthy condition is a parameter that is needed in life, one of the important parameters is the measurement of oxygen saturation in the blood and heart rate. The purpose of this research is to develop a Smartwatch SpO2 device and BPM sensor that is connected to WIFI using the Android Platform instead of using an LCD for parameter reading. This module design method uses the MAX30100 sensor to display the SpO2 and BPM values ​​displayed on the OLED. Data processing is carried out using ATMEGA 328P programming and then displayed in the Android-based Mit-app application. The results show the average error for the SPO2 value is 0.868 % and the standard deviation is 0.170 %, while the BPM value has an average error of 0.56 % and a standard deviation of 0.30%. From the results of the comparison data analysis, the largest error was 1.03% and the smallest was 0.62% for Spo2 ml/hour with an accuracy of 0.05 (0.57%) with a precision value of 0.08 at the selection speed of 50 ml/hour. From the results above, it can be concluded that the data can be displayed on OLED using the Mit-app Android application with an error rate accuracy of 0.57%. From the results of this research design, it is hoped that it can facilitate the diagnosis of the condition of patients and health nurses
Apnea Monitor Using Pulse Oxymetry with Tactile Stimulation to Reduce Respiration Failure Levana Forra Wakidi; I Dewa Hari Wisana; Anita Miftahul Maghfiroh; Vijay Kumar Sharma
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.3

Abstract

Respiratory failure (apnea) often occurs in premature babies, this should be avoided because it causes low oxygen concentrations in the blood so that it can damage brain function and lead to death. Apnea is characterized by a decrease in oxygen saturation (SpO2). The purpose of this study was to design an apnea monitor that was detected with SpO2 parameters, alarms, and vibrating stimulation. This study uses infrared and red LEDs that emit light through the surface of the finger and is detected by a photodiode sensor, this light signal will be converted into an electrical signal and calculated by Arduino to determine the patient's SpO2 and BPM values. If the SpO2 value drops 5% within 5 seconds from the baseline, the device will indicate apnea has occurred and the vibrating motor is working. SpO2 signals and alarms are sent to the nurse station computer via Bluetooth HC-05. The instrument was calibrated with an SpO2 calibrator and the measurement results were compared with a BION pulse oximetry brand. The results of the instrument measurement on two subjects on the SpO2 parameter showed an error value of 2% and the BPM parameter obtained an error value of 4.54%. Testing the BPM parameter using a calibrator at the 30 and 60 BPM settings shows an error value of 0% and at the 120 BPM setting the error value is 0.01%. The vibrating motor to stimulate the baby's body when apnea occurs is functioning properly. The results showed that measurements using subjects tended to have high error values ​​due to several factors. This research can be implemented on patient monitors to improve patient safety and reduce the workload of nurses or doctors
A Coagulation Mode on Bipolar Electrosurgery Unit Using 350 KHz Frequency and Power Selection Prastawa Asalim Tetra Putra; Bambang Guruh Irianto; Tribowo Indrato; Lamidi Lamidi; Rizki Andriyanto; Nora Bouzeghaia
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.2

Abstract

Losing a lot of blood during surgery using a conventional scalpel is something that is highly avoided. The purpose of this study is to replace the conventional scalpel with a tool that utilizes a high frequency whose duty cycle is regulated and then centered at one point. Researchers take advantage of the effect of heat generated by high frequencies which are centered at one point so that it can be used for the process of surgery and coagulation in body tissues so as to minimize the occurrence of a lot of blood loss. Researchers use a high frequency of 350 KHz which is set with a duty cycle of 6% on 94% off and is equipped with 3 levels of power selection and uses forceps as a medium to concentrate high frequencies at one point. The module design consists of a 350 KHz frequency generator, a pulse control circuit to adjust the duty cycle, a power control circuit as a power setting, a driver circuit to combine the frequency with the set power so that different outputs are obtained according to the settings, and an inverter circuit to increase the voltage. In this study, after measuring using an oscilloscope in the driver circuit, the average output amplitude at each low, medium, and high setting was 27.25 Vpp, 28 Vpp, and 28.625 Vpp. The results showed that the bipolar electrosurgery unit (coagulation) module as a whole can replace conventional scalpels so that it can minimize the occurrence of a lot of blood loss during surgery. However, the frequency generator and power selection need to be improved.
Long Distance Dual SpO2 Monitoring System for Premature Babies Using Bluetooth Communication Priyambada Cahya Nugraha; Muhammad Ridha Mak'ruf; Lusiana; Sari Luthfiyah; Wahyu Caesarendra
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 2 (2021): July
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i2.7

Abstract

Monitoring the baby's health status is very important, especially for babies born prematurely. Oxygen saturation levels in newborns are very important to know because when the oxygen saturation levels in newborns are low, it is necessary to watch out for hemodynamic abnormalities in the baby. Measurement of oxygen saturation levels in newborns can help detect congenital abnormalities in infants early. This study aims to design an equipment system to continuously monitor the condition of oxygen saturation in newborns. Where in this discussion a monitoring tool is used to monitor 2 premature babies in a baby incubator simultaneously using a Neonatal Fingertip sensor. The system will display the oxygen saturation (SpO2) value and signal. Monitoring on this tool is done wirelessly using the HC-05. Based on the results of tests and measurements in 5 different patients with a pulse oximeter comparison, the difference value of 1% in each patient's results was obtained. The results of this study will greatly help facilitate the work of paramedics in monitoring the vital conditions of newborn babies.
Design of an Electromyograph Equipped with Digital Neck Angle Elevation Gauge Ahmad Kamil Solihin; Endro Yulianto; Her Gumiwang Ariswati; K. K. Mujeeb Rahman
Journal of Electronics, Electromedical Engineering, and Medical Informatics Vol 3 No 3 (2021): October
Publisher : Department of Electromedical Engineering, POLTEKKES KEMENKES SURABAYA and IKATEMI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.35882/jeeemi.v3i3.4

Abstract

The development of technology also affects human health, including body posture due to poor human position when using gadgets, both smartphones, and laptops. This study is design a tool that can measure the elevation of a person's neck angle equipped with electromyography, to help health workers, medical rehabilitation doctors to diagnose and provide treatment to patients with a bent head posture or forward head posture. In this research, an electromyography module is designed which consists of a series of instruments, a pre-amplifier circuit, a high pass filter, a low pass filter, and a dc offset regulator to be converted to digital so that it can be displayed on a laptop. In this study, the tapped muscle was the upper trapezius muscle using disposable electrodes. Meanwhile, to measure the angular elevation, the MPU 6050 sensor is used to measure the movement of the head forward. The frequency of the electromyography signal is 20-500 Hz. For software or display readings from this tool is Delphy. Meanwhile, the microcontroller used for ADC communication is Arduino Uno. From the research, it was found that the neck angle elevation gauge has a 0,597% error rate, for conditioning conducted on respondents, all respondents experienced a decrease in amplitude on the same frequency spectrum in the last ten minutes. Meanwhile, a drastic decrease occurred at the neck angle of 60°. Thus, it can be concluded that the forward position of the head affects the frequency spectrum of the neck muscles.

Page 5 of 27 | Total Record : 270