cover
Contact Name
Fitrilina
Contact Email
amplifier@unib.ac.id
Phone
+6282221811224
Journal Mail Official
amplifier@unib.ac.id
Editorial Address
Fakultas Teknik Universitas Bengkulu Jl. W.R. Supratman, Kandang Limun BENGKULU 38123
Location
Kota bengkulu,
Bengkulu
INDONESIA
Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer
Published by Universitas Bengkulu
ISSN : 20892020     EISSN : 26222000     DOI : https://doi.org/10.33369/jamplifier
Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer is a scientific communication media which is issued by the Study Programme of Electrical Technic, Faculty of Technic, the University of Bengkulu, with the p-ISSN 2089-2020 and e-ISSN 2622-2000. It is published twice a year in the months of May and November. The authors are required to register in advance and upload the manuscript online. The process of the manuscript could be monitored through OJS. Authors, readers, editorial board, editors, and peer review could obtain the real-time status of the manuscript. A hard copy of the journal could be purchased by the system. Several other changes are informed in Journal History
Articles 100 Documents
Analisis Aliran Daya Pada Sistem Stand Alone Pembangkit Listrik Tenaga Mikro Hidro (PLTMH) Al Hanan Dengan Metode Newton Rhapson Herawati, Afriyastuti; Putra, Ripo Utama; Handayani, Yanolanda Suzantry; Anggraini, Ika Novia
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.24504

Abstract

Analysis of power flow in the power system is used to determine the parameters of the system itself. The benefit of the power flow analysis is to determine whether the amount of power in the electric power system still meets the predetermined limits, as well as to determine the number of existing losses, and to obtain the initial conditions for planning the new system. To solve the power flow problem, a power flow simulation can be performed using ETAP software. Simulations were carried out using the Newton-Rhapson method to determine the flow of power during the rainy and dry seasons. The results of the power flow simulation in the rainy season show that the highest active and reactive power values ​​are found in bus 1, namely 156.78 kW and 101.77 kVAR, while the simulation during the rainy season shows the highest active power and reactive power in bus 1, which is 137.85 kW and 88.97 kVAR. Then the highest voltage drop in the rainy season is 3.11% and the dry season is 2.78%. The Newton-Rhapson method requires 2 iterations to reach a convergent value.
Sistem Pakar Certainty Factor Berbasis Andorid Untuk Identifikasi Kecocokan Lahan Teknologi Salibu Fitrilina, Fitrilina; Syafrizal, Rifky; Latif, Melda; Wahyuni, Ullya Mega
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.25263

Abstract

Indonesi merupakan Negara dengan konsumsi tanaman padi tertinggi di dunia. Pemerintah mentargetkan swasembada beras sehingga terus mengusahakan peningkatan produktivitas padi nasional. Salah satu solusinya adalah dengan mengembangkan teknologi Salibu. Pengembangan Teknologi Salibu selain memberi banyak keuntungan juga memiliki kendala, seperti tidak semua daerah dapat menerapkan teknik ini dan tenaga ahli yang masih kurang dan belum tersebar. Oleh karena itu, pada penelitian ini dirancang suatu aplikasi yang mampu merekomendasikan kondisi suatu daerah Cocok atau Tidak Cocok atau Cocok Bersyarat untuk diterapkan teknologi Salibu. Aplikasi yang dirancang menggunakan sistem pakar dengan metode Certainty Factor dan interface Android. Hasil yang didapat interface berkerja dengan baik. Tingkat akurasi 91,11 % dan kepuasan pengguna 90,5 %. Oleh karena itu dapat dikatakan aplikasi sistem pakar untuk mengidentifikasi kecocokan suatu daerah menerapakan tekonologi Salibu telah dapat digunakan.
Pengujian Tahanan Isolasi Pada Transformator Distribusi 160 kVA Di PT. PLN (PERSERO) UP3 Bengkulu Indra, Mandalahi Haldigian; Yanolanda Suzantry Handayani; Priyadi, Irnanda
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.25274

Abstract

The power transformer is a high voltage equipment that functions as a distributor of electric power from high voltage to low voltage or from low voltage to high voltage. If the transformer's isolation condition deteriorates, it can have an impact on operating failure and the most fatal is that the transformer is damaged which can cause electrical system disturbances. To overcome this it is necessary to test the insulation resistance. This test is carried out using the polarization index method to determine the feasibility of the insulation resistance in the transformer. The use of this method is the most accurate and effective way to determine the feasibility of insulation resistance in transformers at distribution substations in Indonesia. This study took data at the location of PT. PLN (Persero) UP3 Bengkulu. In the insulation resistance test, the polarity index measurement results are obtained. Based on the data that has been collected then proceed with calculations and analysis to obtain better results. The ground-primary polarization index value shows that it is in good condition with a primary-ground value of 1.25 and a secondary-ground polarization index value of 1.5 (good standard between 1.25 – 2.0).
Rancang Bangun Pembangkitan Generator Marx 10 Tingkat pada Uji Kapasitor 220 pF dan Lightning Protector Rodiah, Yuli; Putri, Nilda Tri; Anggraini, Ika Novia; Herawati, Afriyastuti; Rizki, M.
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.24945

Abstract

The Marx generator circuit is an impulse voltage multiplier that is used to represent lightning overvoltage and switching overvoltage. In this research, a 10-level Marx Generator impulse generator design was carried out by varying the distance between the spark gaps of 2.5mm, 5.0mm, 7.5mm, and 10.0mm and the test load was a 220pF capacitor and a lightning protector. The results of the design and simulation of the 10-level Marx Generator produce an impulse voltage according to the IEC 60060-1 lightning impulses standard, which is 20.20kV with a wavefront and tail time of 2.29 µs and 52.3 µs. The test results for the 220pF capacitor load at a distance of 2.5 mm, the resulting voltage is 23.5 kV with a wavefront and tail time of 1.7 µs and 25 µs, while the lightning protector test load produces a voltage of 24 kV, with a wavefront and tail time of 2.1 µs and 43 µs
Analisa Sistem Load Frequency Control dengan Metoda Linear Quadratic Gaussian (LQG) dan Linear Quadratic Gaussian-Loop Transfer Recovery (LQG-LTR) Laksono, Heru Dibyo; Novizon; Widi Adriana , Anisa
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.25908

Abstract

Artikel ini mendeskripsikan perancangan dan analisa sistem Load Frequency Control (LFC) tipe non reheat tanpa dan dengan metoda Linear Quadractic Gaussian (LQG) dan metoda Linear Quadratic Gaussian – Loop Transfer Recovery (LQG – LTR). Sistem Load Frequency Control (LFC) tipe non reheat dinyatakan dalam bentuk persamaan keadaan. Pengendali dirancang dengan metoda LQG dan metoda LQG – LTR dengan bantuan perangkat lunak Matlab serta berdasarkan kriteria perancangan tertentu. Analisa yang dilakukan meliputi analisa tanggapan peralihan, analisa tanggapan domain frekuensi untuk fungsi alih lingkar terbuka, analisa tanggapan domain frekuensi untuk fungsi alih lingkar tertutup dan analisa kekokohan. Untuk analisa tanggapan peralihan, parameter yang diamati waktu naik, waktu puncak, waktu keadaan mantap dan nilai lewatan maksimum. Untuk analisa tanggapan domain frekuensi untuk fungsi alih lingkar terbuka, parameter yang diamati adalah margin penguatan. Untuk analisa tanggapan domain frekuensi untuk fungsi alih lingkar tertutup, parameter yang diamati adalah lebar pita. Untuk analisa kekokohan, parameter yang diamati adalah nilai puncak sensitivitas dan nilai puncak sensitivitas komplementer. Hasil perancangan memeperlihatkan bahwa dengan pengendali LQG – LTR, sistem Load Frequency Control (LFC) memenuhi kriteria perancangan. Adapun nilai parameter yang diperoleh dari tanggapan peralihan meliputi waktu naik sebesar 0.1002 detik, waktu puncak sebesar 0.5086 detik, waktu keadaan mantap sebesar 1.6343 detik dan nilai lewatan maksimum sebesar 17.9010 %. Nilai parameter yang diperoleh dari tanggapan domain frekuensi untuk fungsi alih lingkar terbuka yaitu margin penguatan sebesar tidak terhingga dan nilai parameter yang diperoleh dari tanggapan domain frkeuensi untuk fungsi alih lingkar tertutup yaitu lebar pita sebesar 19.7040 rad/detik dan nilai parameter yang diperoleh dari analisa kekokohan yaitu nilai puncak sensitivitas sebesar 1.1591 dan nilai puncak sensitivitas komplementer sebesar 0.9160.
Sistem Pakar Diagnosa Penyakit Katarak dengan Metode Certainty Factor Mortara, Alda Amalia; Anita Desiani
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 13 No. 1 (2023): Amplifier Mei Vol. 13, No. 1 2023
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v13i1.27265

Abstract

The eye is one of the most vital parts of the human body, which of course must be maintained. Unhealthy eyes will have a bad impact on the sufferer because it can interfere with the sufferer's activity process. One of the simplest and most common eye diseases suffered by humans is cataracts. Symptoms of cataracts occur painlessly so that many sufferers do not realize that they have cataracts. In Indonesia, the main cause of visual impairment and blindness is cataracts. Cases of blindness caused by cataracts occur due to a condition where the lens of the eye becomes cloudy and cataracts do not only occur at an early age but at all ages even though cataracts are a type of blindness that can be avoided and can be cured through treatment. Therefore an expert system is needed to help diagnose cataracts so that prevention can be done as much as possible. One method that can be used by expert systems is the assurance factor method. The advantage of the assurance factor method is that it can provide settlement solutions with the value of disease symptoms given by experts. With the superiority of the assurance factor method, this study will discuss the application of the assurance factor in the diagnosis of cataracts. To diagnose cataracts, there are 18 symptoms with 3 types of disease, namely congenital, juvenile, and traumatic cataracts. This study used 5 data tests based on the symptoms felt by people with cataracts to produce accurate predictions for each type of cataract where 86.0762% congenital cataracts in the first test data, 94.0595% juvenile cataracts in the second test data, 92.5128% traumatic cataracts in the third test data, 92.2440 % juvenile cataracts in the fourth test data, and 90.2080% juvenile cataracts in the fifth test data.
Analisis Pelepasan Beban Sistem Jaringan Bengkulu dengan Penambahan PLTU Teluk Sepang 2x100 MW Herawati, Afriyastuti
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 13 No. 1 (2023): Amplifier Mei Vol. 13, No. 1 2023
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v13i1.27361

Abstract

Load shedding is one way to overcome the rapid decrease in frequency due to transient disturbances. With load shedding the rate of decrease in system frequency can be slowed down so as to avoid total blackouts in the power system. Currently, the Bengkulu network system has added a new power plant, namely PLTU 2 x 100 MW in Teluk Sepang. This paper analyzes load shedding on the Bengkulu network system after the inclusion of PLTU Teluk Sepang. The proposed method is load shedding taking into account the Rate Of Change Of Frequency (ROCOF) and critical fault clearing time (CCT) after a transient fault occurs and then analyzing the stability of the system transient before and after the load shedding occurs with three phase short circuit disturbance. The analysis found that the proposed method succeeded in returning the dropped frequency to the permitted frequency value and the system showed a stable response after a transient disturbance occurred.
Sistem Kendali Suhu Prototipe Mesin Pengering Biji Kopi Dengan Metode PID dan IOT Monitoring Kurniawan, Adhadi; Raka Thareq Azis Pohan; Indra Agustian
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 13 No. 1 (2023): Amplifier Mei Vol. 13, No. 1 2023
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v13i1.27437

Abstract

Proses pengeringan biji kopi yang dilakukan petani kopi masih banyak dilakukan secara tradisional di lapangan terbuka atau di jalanan. Dan juga proses pengeringan biji kopi secara tradisional masih dipengaruhi faktor cuaca yang tidak menentu sehingga menyebabkan lamanya proses pengeringan. Dengan prototipe mesin pengering biji kopi menggunakan sensor suhu DHT22 dan pemanas DC serta sistem kendali suhu metode PID Ziegler Nichols dapat melakukan proses pengeringan dengan suhu optimal antara 50 – 60 C secara konstan. Hasil pengujian dengan metode Ziegler Nichols didapatkan nilai konstanta PID yang optimal dengan nilai Kp sebesar 33,6, nilai Ki sebesar 0,336 , dan nilai Kd sebesar 1,34. Dimana suhu optimal didapat selama 900 detik setelah proses pengeringan dimulai. Sedangkan pengeringan tanpa kendali PID yang membutuhkan waktu 1400 detik. Hasil pengujian dengan menggunakan PID Ziegler Nichols menunjukkan bahwa pengeringan membutuhkan waktu jauh lebih cepat untuk mencapai suhu optimal dibandingkan pengeringan tanpa kendali PID. Data dari hasil pengukuran suhu yang dikendalikan dengan metode PID Ziegler Nichols dapat dimonitoring dengan website Thingspeak. Kata Kunci: Mesin Pengering Biji kopi, PID, Ziegler Nichols ABSTRACK The process of drying coffee beans by coffee farmers is still mostly done traditionally in open fields or on the streets. And also the traditional process of drying coffee beans is still influenced by erratic weather factors, which causes the drying process to take a long time. With a prototype coffee bean drying machine using a DHT22 temperature sensor and DC heating and a temperature control system PID Ziegler Nichols method can carry out the drying process with an optimal temperature between 50 – 60 C constantly. The test results with the Ziegler Nichols method obtained the optimal PID constant value with a Kp value of 33.6, a Ki value of 0.336 , and a Kd value of 1.34. Where the optimal temperature is obtained for 900 seconds after the drying process begins. Meanwhile, drying without PID control takes 1400 seconds. Test results using PID Ziegler Nichols show that drying takes much faster time to reach the optimal temperature than drying without PID control. Data from the results of temperature measurements controlled by the Ziegler Nichols PID method can be monitored on the Thingspeak website. Key Words : Coffee Bean Dryer, PID, Ziegler Nichols
Pengaruh Arus Eksitasi Terhadap Pembebanan Pada Generator Sinkron Unit 7 di ULPLTA TES LEBONG PT PLN (PERSERO) Handayani, Yanolanda Suzantry; Anggita Juliana; Irnanda Priyadi
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 13 No. 1 (2023): Amplifier Mei Vol. 13, No. 1 2023
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v13i1.27513

Abstract

Generator merupakan salah satu bagian dari sistem tenaga listrik yang digunakan untuk mengkonversi energi mekanik yang berasal dari putaran turbin menjadi energi listrik dengan memanfaatkan gaya gerak listrik. Eksitasi merupakan salah satu bagian yang paling krusial pada sistem Generator yang berperan untuk menghasilkan fluks yang berubah terhadap waktu, sehingga dihasilkan satu GGL induksi. Arus penguatan digunakan untuk mengatur besarnya tegangan keluaran sesuai pembebanan yang diterapkan. Adapun alat yang digunakan untuk mengatur arus eksitasi adalah Automatic Voltage Regulator (AVR). Pembebanan yang dibedakan pada pembangkit setiap waktunya berubah ubah. Oleh karenanya suatu pembangkit tenaga listrik harus mampu membangkitkan daya listrik sesuai dengan besarnya beban yang berubah-ubah tersebut. Pada pembangkitan tenaga listrik, fluktuasi pembebanan ini dapat diatasi dengan mengatur bukaan katup air dan arus eksitasi yang di-injeksikan pada rotor generator pada putaran rotor yang konstan oleh AVR sehingga dihasilkan daya listrik sesuai pembebanan yang diterapkan. Tujuan penelitian ini adalah untuk menganlisa pengaruh beban terhadap arus eksitasi. Adapun hasil yang didapatkan adalah beban berpengaruh ter-hadap arus eksistasi.
Simulasi dan Analisa Sistem Kendali Frekuensi Tenaga Listrik Dengan Pilot Servo dan Kombinasi Pengendali Model Standar (Model Hidraulik) Laksono, Heru Dibyo; Retno Ningsih , Fina; Fitrilina
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 13 No. 1 (2023): Amplifier Mei Vol. 13, No. 1 2023
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v13i1.27591

Abstract

Kualitas dari suatu operasi sistem tenaga listrik salah satunya ditentukan dari kestabilan nilai frekuensi pada sistem. Sistem kendali frekuensi tenaga listrik berfungsi untuk menjaga kestabilan frekuensi pada sistem tenaga listrik agar berada pada nilai normal dengan batas toleransi yang telah ditetapkan, yaitu 50Hz dengan toleransi ±2%. Tujuan dari penelitian ini adalah untuk memperoleh informasi tentang perbandingan tanggapan sistem tanpa pengendali, dengan pengendali, dengan pilot servo, dengan pengendali dan pilot servo, serta mengetahui range konstanta transient droop dan reset time yang memenuhi kriteria perancangan. Hasil analisa menunjukkan bahwa performansi terbaik ditunjukkan saat sistem ditambahkan pengendali PD dengan nilai ess masukan undak = 0.0415, waktu naik (tr) = 0.37576 detik, waktu puncak (tp) = 1.6172 detik, waktu keadaan mantap (ts) = 3.5498 detik, dan lewatan maksimum (Mp) = 14.306%, sedangkan pada sistem dengan variasi konstanta transient droop dan reset time, tidak ada nilai konstanta yang memenuhi kriteria perancangan. Setiap parameternya memiliki hubungan yang berbeda dengan variasi konstanta.

Page 6 of 10 | Total Record : 100