cover
Contact Name
Fitrilina
Contact Email
amplifier@unib.ac.id
Phone
+6282221811224
Journal Mail Official
amplifier@unib.ac.id
Editorial Address
Fakultas Teknik Universitas Bengkulu Jl. W.R. Supratman, Kandang Limun BENGKULU 38123
Location
Kota bengkulu,
Bengkulu
INDONESIA
Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer
Published by Universitas Bengkulu
ISSN : 20892020     EISSN : 26222000     DOI : https://doi.org/10.33369/jamplifier
Jurnal Amplifier: Jurnal Ilmiah Bidang Teknik Elektro dan Komputer is a scientific communication media which is issued by the Study Programme of Electrical Technic, Faculty of Technic, the University of Bengkulu, with the p-ISSN 2089-2020 and e-ISSN 2622-2000. It is published twice a year in the months of May and November. The authors are required to register in advance and upload the manuscript online. The process of the manuscript could be monitored through OJS. Authors, readers, editorial board, editors, and peer review could obtain the real-time status of the manuscript. A hard copy of the journal could be purchased by the system. Several other changes are informed in Journal History
Articles 100 Documents
Analisis Pengaruh Penambahan Penyulang Dan Pemisahan Beban Terhadap Susut Daya Menggunakan Metode Simple Branch Exchange (Studi Kasus PT PLN ULP Lima Puluh, Sumatera Utara) Priyadi, Irnanda; Haidi, Junas; Sihotang, Candra
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 11 No. 2 (2021): Amplifier November Vol. 11, No. 2 2021
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v11i2.18579

Abstract

AbstractDuring the distribution process there will be a loss of some of the energy that is channeled. This phenomenon is known as losses. This is caused by technical and non-technical factors. In the  State Electricity Service (PLN) system, distribution losses or energy losses is calculated by measuring the difference between kWh produced and kWh sell. This kWh difference is the electrical energy lost during the starting process from the generation or secondary side of the Substation to customers’ APP. Cumulatively, the amount of kWh at all base sources is 73,769.524 kWh while the distribution loss that occurs in JTM is 5,835.008 or 7.91%. One way to overcome and minimize distribution losses in the 20 kV Procurement Service Unit (ULP) of Lima Puluh distribution system is to analyze the distribution network system, add new feeders and break the load on the electrical system. The simple branch exchange method is used to separate the network load, which is done by adding a switch by turning the on or off channel and searching for the configuration that produces the smallest power loss and calculating the power loss based on the network load. Based on the simulation results using the ETAP 12.6 software, the results of the energy loss of Procurement Service Unit (ULP) of Lima Puluh is 5,864,112 kWh then decreased after load separation of 4,341,348 kWh. The value of power loss before load separation is 1,955 kW and a decrease in power loss after load separation is 1,484.5 kW. The investment cost incurred for the construction of a new feeder is RP. 22,000,000,000,- with a payback of 9.9 years.  Keywords: Feeder, Power Loss, Energy Loss, ETAP 12.6.
PERANCANGAN DAN PENGUKURAN PERFORMANSI JARINGAN FIBER TO THE HOME DENGAN TEKNOLOGI GIGABIT PASSIVE OPTICAL NETWORK MENGGUNAKAN APLIKASI OPTISYSTEM DI KELURAHAN SURAU GADANG aulia, siska; fitri, silvia; asril, aprinal adila
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 11 No. 2 (2021): Amplifier November Vol. 11, No. 2 2021
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v11i2.19079

Abstract

Pada tugas akhir ini dirancang suatu jaringan Fiber To The Home ( FTTH) di Kelurahan Surau Gadang yang mana daerah tersebut dilakukan perancangan dan pengukuran performasi jaringan dimana standar yang digunakan sesuai dengan PT. ICON+. Tata cara yang digunakan dalam perancangan ini ialah penen- tuan posisi, pengumpulan informasi, serta perancangan memakai aplikasi Google Earth serta OptiSystem. Hasil dari perbandingan antara pengukuran OptiSystem dan pengukuran di lapangan didapatkan hasil redaman yang berbeda, dimana hasil pengukuran pada OptiSystem pelanggan dengan jarak terjauh menghasilkan daya terima sebesar -18.277 dBm sedangkan untuk pengukuran di lapangan pelanggan dengan jarak terjauh menghasilkan daya terima sebesar -18.52 dBm. Parameter Rise Time Budget didapatkan dari perhitungan ialah 0. 029 ns yang sudah memenuhi stndar kelayakan ialah tidak lebih dari 0. 219 ns sedangkan nilai Bit Error Rate pada simulasi ialah 8.11464 x 10-33 yang sudah memenuhi standar kelayakan ialah tidak lebih dari 10-9. Nilai Signal To Noise Ratio (SNR) merupakan 50.044831 dB yang pula penuhi standar minimal SNR ialah 21.5 dB. Dari hasil perhi- tungan serta hasil simulasi didapatkan nilai-nilai yang masih memenuhi standar kelayakan jaringan Fiber To The Home sehingga rancangan layak buat diimplementasikan.
Sistem Pengatur Tegangan Otomatis : Analisa Peralihan Dengan Pengendali Tunggal Dan Kaskade Laksono, Heru Dibyo; Novizon, Novizon; Latif, Melda; Gunawan, Eko Amri; Afrianita, Reri
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 11 No. 2 (2021): Amplifier November Vol. 11, No. 2 2021
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v11i2.19133

Abstract

This journal describes the design and analysis of the response of a single controller and cascade direct current type of Automatic Voltage Regulator (AVR) system. The direct current AVR system is represented form of a transfer function. For single and cascade controllers, it is designed using a parallel architecture using MATLAB software with predetermined design criteria. The types of controllers used consist of Proportional Differential (PD), Proportional Integral (PI), Proportional Integral Differential (PID), Proportional Differential with First Order Filters in the Differential Section (PDF) and Proportional Integral Differentials with First Order Filters in the Differential Section(PIDF). For the transition analysis, the observed parameters consist of rise time, peak time, steady state time, maximum pass value and peak value. The results of the analysis show that the controllers that meet the design criteria are Proportional Differential (PD) controllers and Proportional Differential controllers with First Order Filters in Differential Sections (PDF) for single controllers and cascade controllers. For a single controller, the value of the Proportional constant (Kp) is 0.6280 and the value of the Differential constant (KD) is 0.1710 for the Proportional Differential (PD) controller. Proportional constant value (Kp) is 0.6130, Differential constant value (KD) is 0.1710 and filter constant value (Tf) is 0.0009 for Proportional Differential controller with First Order Filter in Differential Section (PDF). Cascade controllers and Proportional Differential (PD) controllers, the Proportional constant (Kp) is 1.7300 and the Differential constant (KD) is 0.0242 for the inner circle (C2). Outer ring controller (C1), the proportional constant (Kp) is 179,000 and the Differential constant (KD) is 2.4600. Cascade controllers and Proportional Differential controller types with First Order Filters in the Differential Section (PDF), the Proportional constant (Kp) value is 1.5900, the Differential constant (KD) value is 0.0246, the filter constant value (Tf) is 0.0018 for the inner circumference (C2 ). For the outer ring controller (C1), the Proportional constant (Kp) value is 134,0000, the Differential constant (KD) value is 2.2900 and the filter constant value (Tf) is 0.00008.
Sistem Kendali Suhu Mesin Tetas Telur Ayam Buras Menggunakan Kontroler PID dengan Metode Tuning Ziegler Nichols Open Loop Step Response Agustian, Indra; Prakoso, Dian S; Faurina, Ruvita; Daratha, Novalio
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.21535

Abstract

An egg incubator is a tool that helps the process of hatching eggs using an electric heater and is equipped with an egg rack that functions to evenly distribute the heat in the incubator. Good temperature control in the hatching process is something that greatly affects the hatching results. In this study, an egg incubator temperature control system was designed using the PID method with the Ziegler Nichols Open Loop Step Response tuning method. The control system is specifically for free-range chicken eggs which require a normal temperature of 37 °C-39 °C. The main control components are the microcontroller, the incandescent lamp heater, and the DHT22 temperature sensor. The open loop test shows a time delay of 20 seconds and a time constant of 385 seconds, so with the Ziegler Nichols open loop tuning method, the values of Kp = 23.1, Ki = 40, and Kd = 10. The test results show that the PID controller can control the temperature properly. In testing the hatching process within 21 days, the temperature control worked well, and the effect of changes in day and night temperature did not significantly affect the performance of the PID controller.
Perhitungan Suhu Pada Bushing Transformator Unit II GI Pekalongan dengan Metode Elemen Hingga Herawati, Afriyastuti; Rosa, Muhammad Khairul Amri; Surapati, Alex; Handayani, Yanolanda Suzantry; Anggraini, Ika Novia; Rodiah, Yuli; Nugraha, Andi
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.21310

Abstract

The reliability of the power transformer depends on the performance of the its bushing. Transformer bushings subjected to hot conditions or high temperatures for a long period of time can cause bushing failure. Bushing failure can result the damage such as bursting of the conservator tank, explosion and fire. The purpose of this study was to determine the temperature hot spot on the transformer bushing at the Unit II Pekalongan Substation (GI) in order to avoid the damage of transformer. The method that used to analyze the hot spot temperature on the transformer bushing is the finite element. The finite element method is carried out by dividing the bushing parts into small elements to be calculated so that the hot spot temperature value on the transformer bushing is obtained. The result of the highest hot spot temperature on the transformer bushing which were carried out four times using the finite element method is . Based on the IEEE standard, the hot spot temperature of transformer bushing can’t be more than . This result showed that transformer bushng of Unit II Pekalongan Substation are still in the normal category.
Identifikasi Tingkat Kesegaran Ikan Berbasis Android styorini, wiwin -; Pratiwi, Anggita -; Widiasari, Cyntia -
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.19174

Abstract

Ikan merupakan salah satu makanan yang penting bagi tubuh, sebab ikan mengandung protein tinggi yang sangat diperlukan oleh tubuh. Selain itu, harga ikan juga lebih murah dibanding dengan daging yang juga mengandung protein. Namun banyak masyarakat yang salah dalam memilih ikan, kebanyakan ikan yang beredar di pasaran sudah tidak segar lagi, sehingga apabila di konsumsi dapat membahayakan tubuh. Oleh karena itu, dirancanglah sebuah aplikasi pendeteksi kesegaran ikan yang diberi nama aplikasi AKSI GRAKAN yaitu aplikasi untuk mendeteksi tingkat kesegaran ikan menggunakan pengolahan citra digital (image processing) yang berbasis android. Pada penelitian ini obyek yang dideteksi adalah mata ikan dengan menggunakan metode ruang warna citra RGB. Sedangkan untuk klasifikasi menggunakan metode K-Nearest Neighbor (KNN) untuk dapat mengelompokkan ikan dengan 4 kondisi yaitu sangat segar, segar, kurang segar atau tidak segar. Pada penelitian ini menggunakan 2 jenis smartphone, Untuk  smartphone dengan spesifikasi smartphone dual kamera belakang 13MP+5MP menghasilkan tingkat akurasi sebesar 93,75 dan smartphone dengan spesifikasi smartphone dual kamera belakang 13MP+2MP  tingkat akurasinya adalah 90%. Waktu yang dibutuhkan untuk mengidentifikasi dari proses capture sampai klasifikasi jenis ikan adalah 3-5 detik. 
Prototipe Turbin Angin Savonius Pada Kecepatan Angin Skala Kecil Untuk Pengisian Baterai Latif, Melda; Farizi, AL; Muharam, Mumuh; Laksono, Heru Dibyo; Yunus, Syukri; Rajab, Abdul; Fitrilina, Fitrilina
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.21673

Abstract

The Vertical Axis Wind Turbines are very suitable for use in areas with very low wind speeds. This research makes a prototype of the Savonius wind turbine to produce electrical energy as an energy source to 2 x 3.7 Volt dry battery. The Savonius turbine has four blades made of PVC. The controller circuit consists of a Boost Converter circuit and an astable multivibrator. At a speed of 2.7 m/s, the wind turbine starts to rotate and produces a no-load voltage of 0.3 V. At a speed of 3.7 m/s a voltage of 2 V is generated and can charge the battery. By using an LED (Light Emitting Diode) in the controller circuit, the charged battery can be a source of voltage in the controller circuit and the LED indicator light can be lit.
Pengaruh Total Harmonic Distortion (THD) Terhadap Pembacaan kWh Meter Semi Digital Surapati, Alex; Panggabean, Martin; Rosa, Muhammad Khairul Amri
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.21460

Abstract

AbstrakEnergy measurement using a kWh meter must have good accuracy. The increasing use of non-linear electrical equipment causes harmonics in the network. This study aims to measure and analyze voltage, current, power, power factor and the percentage of Total Harmonic Distortion (THD). The research was carried out by designing and making a device in the form of an electrical circuit connected to a semi-digital kWh meter with a fixed load of 10 incandescent lamps with a power of 100 watts each and 1 single-phase induction motor. The test results show that the incandescent lamp load test produces a THD-I percentage of 3.5% and a THD-V percentage of 3.7% with a measurement error value of 0.675%. In the motor load test, the percentage of current harmonics becomes high at 16.6% and the THD-V percentage is 3.4% and the measurement error value is 3.48%. In testing the variation of the load combination of an induction motor and incandescent lamps, the percentage of THD-I is 5.8% and the percentage of THD-V is 3.2% with an error value of 3.57%. The greater the THD percentage value, the greater the reading error on the semi-digital kWh meter and the worse the resulting power factor value. Kata kunci: Non-linear load, kWh Meter, THD
Implementasi Metode AHP Pada Sistem Pendukung Keputusan Wisata Taman Kota Medanw Pebrianti, Lidia; Sirait, Gian Patar P.; Purba, Yeremia Tiopan Pandapotan
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 1 (2022): Amplifier Mei Vol. 12, No 1 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i1.21679

Abstract

Parks are the most alternative tourist attractions. With an open area, as well as a lot of various plants, it really supports the general public just to relax with the family. When traveling, tourists usually decide to visit interesting tourist destinations. The number of tourist destinations available, often makes tourists confused about choosing a destination according to their preferences. Therefore, this research is intended for tourists to be able to determine park tourism destinations in Medan based on several categories based on beauty, security, and facilities. One of the computational methods intended to assist in current decision making is a decision support system or Analytic Hierarchy Process (AHP). In a decision support system, any information can be processed into the best alternatives as an alternative decision result. From the results of the questionnaire analysis stage, 20 out of 31 respondents had difficulty in choosing a park tourism destination. After using the AHP method, the first place is The Le Hu Garden with a weight of 0.501, the second is followed by Taman Cadika Pramuka with a weight of 0.488, and in the last order Taman Sri Deli with a weight value of 0.473.
Kombinasi Metode Entropy dan Simple Additive Weighting (SAW) dalam Pemilihan Dosen Pembimbing Skripsi Nisa, Halimatun; Aulia, Fitrahuda; Rayhan, Annisa
JURNAL AMPLIFIER : JURNAL ILMIAH BIDANG TEKNIK ELEKTRO DAN KOMPUTER Vol. 12 No. 2 (2022): Amplifier November Vol. 12, No. 2 2022
Publisher : UNIB Press

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.33369/jamplifier.v12i2.21733

Abstract

In the preparation of the thesis, students need a supervisor as a place of consultation in completing the thesis. The supervisor should be a person who mastered the field in accordance with the topic of student thesis, so that the guidance process can run optimally. Thesis is one of the graduation requirements to obtain a bachelor's degree. Generally, the selection of thesis supervisors is decided by the study program through a meeting of lecturers to determine which lecturers are in accordance with the title and description of the students who took the thesis course. To solve this problem, a solution is needed that can take into account the specifications of lecturer expertise that suits the needs of students. The Entropy method is an alternative to solve this problem. This method was chosen because it is able to select the best alternatives from a number of alternatives, in this case the intended alternative is to be a supervisor and examiner based on the specified criteria. Research is carried out by looking for the weight value for each attribute, then a casting process is carried out that will determine the optimal alternative, namely the four lecturers whose specification values are highest.Keyword: Decision Support System, Entropy, Thesis

Page 5 of 10 | Total Record : 100